SH A P SINGH, IDSE,SE
HQ CWE CHANDIMANDIR
CA NO CWE/CHM(U)-44/2021-22 REPAIR AND MAINT OF EXTERNAL ELECTRIC HT 11 KV DISTRIBUTION NETWORK AND CONNECTED ITEMS OF WORK AT MD AREAS AT CHANDIMANDIR
2021_MES_463664_1
CWE/CHM(U)-44/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
HQ CWE CHANDIMANDIR
class C cat b(ii)
8 documents required · 8 mandatory
₹1,000
Yes
GE (U) CHANDIMANDIR
₹1.0 L
Yes
5 Oct 2021
29 Jul 2021
8 Sept 2021
29 Jul 2021
4 Sept 2021
20 Aug 2021
60 days
Amount
Excavation in trenches in hard/dense soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth; for laying of cable, poles etc. and getting out complete all as specified and directed.
All as per item No 1 here-in-before but depth exc 1.5 mtr and not exc 3.0 mtr in depth complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
Supplying and laying un-reinforced precast cement concrete cable cover, class HV, type 1 flat , size 300mm x 180mm x 40mm, ISI marked, complete all as specified and directed.
M & L for old size bricks laid flat for protection to UG LT cables complete all as specified and directed.
M & L for dry sand filling under and around UG cable to provide cushioning complete all as specified and directed. Note. Punned thickness shall be measured.
M & L for GI tubes 100 mm bore light grade for cable protection on poles/walls/under road/culvert etc complete all as specified and directed.
M & L for GI tubes 80 mm bore light grade for cable protection on poles/walls/under road/culvert etc complete all as specified and directed.
M & L for PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in pole foundations etc complete all as specified and directed.
M & L for PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in foundation filling & mass concrete for poles/struts etc including provision of necessary form work complete all as specified and directed.
M & L for PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate in pole / strut coping including necessary form work complete all as specified and directed.
Disconnecting and taking out existing defective HT cable of any size complete including joints/protection pipes etc from trenches/ducts/poles etc complete all as specified and directed.
Taking out old damaged PCC pole of any size incl clearing the site complete all as specified and directed.
Taking down old rusted cross arms/anti climbing devices incl clamps, nuts/bolts etc complete all as specified and directed.
Disconnecting and taking out feeder pillar box of any type and size complete all as specified and directed.
Taking down old unserviceable HT GOD of any size/type complete all as specified and directed.
Taking out the existing sign board of any size/type and supply and install Retro reflective sign boards for electrical installation of size 4 feet x 5 feet (print area) as per the following specifications:- [a] Post (pillar pipe) 50 mm dia 2mm thickness SS 304 grade 9.5 feet long - 02 Nos fitted with MS base plate 150mm x 150 mm & 5 mm thickness at the bottom and 50mm dia SS balls on the top. [b] Pipe for print area frame using 32 mm dia 1.2 mm thickness SS 304 grade pipe and 06 Nos connecting pipes of 50 mm length. [c] SS rivetted strip 2 mm thickness and size 30 mm length & 25 mm width - 16 Nos [d] 3 mm thick ACP sheet (aluminium composite sheet) of size 4 feet x 5 feet along with 1 mm thickness retro reflective material of approved colour and writing work in capital letters and numbers on both sides of ACP sheet all as specified and directed. [e] PCC 1:2:4 type B-1 block of size 300mm x 300mm x 450 mm - 02 Nos for grouting of sign board incl earth work complete all as specified and directed.
M & L in repairs 32 mm x 6mm GI strip connecting from earth test point to lightening arrestor installed on top of 11 mtr long poles four pole/ two pole structures complete all as specified and directed.
M & L in replacement route indicator for HT cable disc type of size 150 mm dia CI, 8 mm thickness embossed with "MES HT CABLE" and fixed on angle iron 35 x 35 x 5 mm, 600mm long as directed and painted in anti corrosive brown colour paint incl PCC 1:2:4 type B-1 foundation block of size 300 x 300 x 300 mm, duly fixed in ground complete all as specified and directed.
S & F gang operated air break switches with vertical isolation complete with drop out fuse unit triple pole, 12 insulator type, manually operated, mounted on insulators and steel frame, with operating mechanism worked from ground level for rating 400 Amps, 11000 volts complete with GI operating pipe of heavy duty grade of suitable size and length complete all as specified and directed.
All as per item No 21 here in before but of rating 200 Amps complete all as specified and directed.
M & L for servicing of the outdoor type HT 11000 volts 200 amps/400 amps capacity gang operated air break switch mounted on HT two pole/four pole structure by properly adjusting the mountings for ON/OFF operation by working from ground level, adjusting the length of operation rod ,lubricating the moving parts, tightening of all nuts/bolts, checking of all jumper connections for proper contact of male/female contacts, with and including taking down & replacing worn out spares and testing for proper working complete all as specified and as directed. Note :- New spare parts will be measured and paid separately.
Supply only moving contact blade (male contact) suitable for 200 amps 11 KV outdoor GOAB switch complete all as specified and directed.
Supply only spring loaded fixed contacts (female contact jaw) suitable for 200 amps 11 KV outdoor GOAB switch complete all as specified and directed.
Supply only moving contact blade (male contact) suitable for 400 amps 11 KV outdoor GOAB switch complete all as specified and directed.
Supply only spring loaded fixed contacts (female contact jaw) suitable for 400 amps 11 KV outdoor GOAB switch complete all as specified and directed.
Supply only 11 KV porcelain post insulators suitable for outdoor GOAB switch complete all as specified and directed.
Supply only tinned copper flexible wires woven connecting jumper suitable for 11 KV outdoor GOAB switch complete all as specified and as directed.
Supply only MS jumper carrier for 11 KV outdoor GOAB switch complete all as specified and as directed.
M & L for disconnecting from the panel board, cutting off worn out aluminium cable end, supply and fixing of new heavy duty aluminium cable lugs , connecting the cable with panel board including insulation tapes etc complete all as specified & directed for 95 sqmm to 150 sqmm sizes of LT cables.
All as per item No 31 here-in-before but size 185 sqmm to 240 sqmm complete all as specified and directed.
All as per item No 31 here-in-before but size 300 sqmm to 400 sqmm complete all as specified and directed.
All as per item No 31 here-in-before but size 500 sqmm to 630 sqmm 3.5 complete all as specified and directed.
M & L anti climbing devices, spikes type fabricated out of M.S. bars ( round,square and flat ) including nuts,bolts,Washers and clamps in two halves made to shape to suit the cross section of the pole complete all as specified and directed.
S & F in trenches, ducts or fixing along the poles or passing through pipes or laid under floors etc and testing XLPE insulated , screened PVC bedded, galvanised steel strip armoured, heavy duty HT power cables ISI marked with aluminium conductor, 11000 volts grade cross sectional area 95 sqmm 3 core, 11 KV earthed, complete all as specified and directed.
All as per item No 36 here-in-before but 150 Sqmm 3 core complete all as specified and directed.
All as per item No 36 here-in-before but 185 Sqmm 3 core complete all as specified and directed.
All as per item No 36 here-in-before but 240 Sqmm 3 core complete all as specified and directed.
S & F HT heat shrinkable type outdoor end termination cable jointing kit with jointing material and accessories suitable for 11 KV (Earthed) grade XLPE cable of size 95 Sqmm, 3 core complete all as specified.
All as per item No 40 here in before but of size 120 to 185 Sqmm, 3 core complete all as specified and directed.
All as per item No 40 here in before but of size 240 sqmm, 3 core complete all as specified and directed.
S & F HT heat shrinkable type indoor end termination cable jointing kit with jointing material and accessories suitable for 11 KV (Earthed) grade XLPE cable of size 95 Sqmm, 3 core complete all as specified.
All as per item No 43 here in before but of size 120 to 185 Sqmm, 3 core complete all as specified and directed.
All as per item No 43 here in before but of size 240 sqmm, 3 core complete all as specified and directed.
S & F HT straight through heat shrinkable type cable jointing kit with jointing material and accessories suitable for 11 KV (Earthed) grade, XLPE cable of size 95 sqmm 3 core complete all as specified and directed.
All as per item No 46 here in before but of size 120 to 185 Sqmm, 3 core complete all as specified and directed.
All as per item No 46 here in before but of size 240 sqmm, 3 core complete all as specified and directed.
Supply, laying, jointing and testing LT underground cable XLPE insulated , PVC sheathed, armoured heavy duty and 1100 volts grade with multistranded aluminium conductor of size 300 sqmm 3.5 core in trenches/ducts/through pipes/under culverts etc complete all as specified and as directed.
All as per item No 49 here in before but size 400 sqmm 3.5 core complete all as specified and directed.
All as per item No 49 here in before but size 500 sqmm 3.5 core complete all as specified and directed.
M & L for disconnecting HT cable of size 150/185/240 sq mm 3 core from line , taking down carefully from poles/ structure, extending the length and reconnecting by taking up and testing for working complete all as specified and directed.
M & L cross arms bracings, supports, clamps, back plates, etc fabricated from structural steel section including nuts, bolts , washers, welding, bending ( cold or hot ) drilling holes for bolts bent to any shape or size as indicated or directed inclusive of one primer coat of red oxide zinc chromate one under coat and one finishing coat of aluminium paint complete all as specified and directed.
M & L PCC 1:2:4 type B-2 using 40 mm graded crushed stone aggregate as in transformer foundation including form work as required at site with and incl breaking/ demolition of the existing damaged foundation of any type and clearing the site complete all as specified and directed.
Supply, installation,commissioning and testing outdoor type CPRI approved make floor mounting double door feeder pillar box of size not less than 1200 x 1500 x 450 mm , fabricated from 3.15 mm thick CRCA sheet and MC 75 for base channel, 04 nos legs 750 mm long made from 50 x 50 x 6 mm angle iron , dully powder coated, dust/water and water proof , grouted in PCC 1:2:4 type B-1 foundation, suitable for 415 volts, 3 phase, 4 wire , 50 Hz complete with and including the following:- [a] Aluminium strip bus bar TPN sleeve insulated mounted on epoxy insulators of capacity 1000 amps - 01 set. [b] INCOMING- MCCB FP 630 amps , 415 volts, 50 Hz, 50 KA with adjustable thermal and magnetic release and Ics=100% of Icu - 01 No [c] OUTGOING - MCCB TP 315 amps , 415 volts, 50 Hz, 35 KA with adjustable thermal and magnetic release and Ics=100% of Icu - 01 No , MCCB TP 250 amps , 415 volts, 50 Hz, 35 KA with adjustable thermal and magnetic release and Ics=100% of Icu - 02 No and MCCB TP 63 amps , 415 volts, 50 Hz, 35 KA with adjustable thermal and magnetic release and Ics=100% of Icu - 02 No [d] Earthing terminals - 02 Nos and danger notice plate - 01 No. [e] Digital voltmeter flush mounting type three phase 0-500 volt range size 96x96 mm - 01 No, Digital ammeter flush mounting type three phase 0-750 amps range size 96x96 mm - 01 No, LT CTs ratio 630/5 amps - 03 Nos, control wiring with single core copper cable FRLS of suitable size incl protection device for each circuit complete.
Disconnecting the electrical supply, disconnecting incoming/outgoing cable connections, taking down the existing transformer of capacity 200 KVA to 500 KVA from the foundation/four pole structure etc and shifting to a location within cantt area using crane of suitable capacity and keeping on the foundation/four pole structure safely, making all incoming/outgoing cable connectios and testing for satisfactory working complete all as specified and directed.
M & L in replacement pin type insulator porcelain, vitreous white/brown including one galvanised MS spindle nut and two GI washers of size 150 mm height, 150 mm dia for 11000 volts complete all as specified and directed.
M & L in replacement single disc porcelain, vitreous white/brown insulator 255 mm dia and 145 mm height assembly for tension with tension clamps for conductor working pressure 11000 volts complete all as specified and directed.
S & F steel tubular swaged poles complete with mild steel base plate, closed at top as specified, type 410 SP-55 (11 metre long) including painting with two coats of black bitumonous paint externally up to the planted depth and internally through out and remaining external portion with two coats of aluminium paint , over a coat of red oxide primer complete all as specified. Note. Excavation & earthwork, foundation concrete will be meaured & paid for separately under respective item(s).
M & L in replacement danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and onventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT,25x 20 cm size complete all as specified and directed.
M & L in replacement danger notice board made from 3 mm thick mild steel sheet, painted with two coats of signal red colour over a coat of red oxide primer and writing work with white enamelled paint with and incl fixing with M.S. clamps, bolts and nuts of size 45x45 cm size complete all as specified and directed.
M & L for complete removal of existing treatment of old steel tubular poles 11 Mtr long alonwith cross arms / clamps etc and applying two coats of aluminium paint over a coat of red oxide primer with and incl providing red & black paint with 30 cm alternate strip up to 1.2 mtr height from GL complete all as specified and directed.
S & F in replacement jumpers in red/yellow/blue colour for HT lines/connections made from aluminium conductor single core PVC insulated cable of suitable size complete including winding wires, aluminium tapes etc all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick burried directly in ground ( earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised earth lead strip 32 x 6mm by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 3 of SSR Part-I 2009 connected to earthing test point all as specified or indicated and testing on completion as directed by the Engineer-in-Charge including necessary excavation & earth work in any type of soil, funnel, PCC chamber (1 : 3 : 6) type C1, CI pit cover and frame , charcol, salt including earth lead protected by 40 mm dia medium grade GI pipe and 20mm dia medium grade GI Pipe for watering complete. Note. Earth lead strip 32 x 6 mm and GI 40 mm dia medium grade protecion pipe upto 7.5 mtr length will be deemed to include in the quoted unit rate.
All as per item No 64 here in before but galvanised earth lead GI wire 4 mm dia and earth lead protected by 15 mm dia medium grade GI pipe. Note :- Earth lead wire 4 mm and GI 15 mm dia protecion pipe upto 7.5 mtr length will be deemed to include in the unit rate quoted.
Finding of fault to 11 KV UG cable with suitable fault locator equipment & pin point the fault in the faulty cable including necessary excavation and earth work for exposing the faulty portion of the UG cable complete all as specified and directed.
M&L for cutting wild grass,bushes shrubs etc and cleaning of area/yard of sub station buildings complete all as specified and directed by Engr-in-Charge
Supply and filling for topping up insulating oil with dielectric strength not less tha 50 KV complete all as specified and directed.
M & L for boring/driiling hole under and across the road surface/hard standings etc at a depth as directed for passing of 100/80 mm dia GI pipe using a suitable drilling machine and other T&P without damaging the road / hard surface complete all as specified and directed.
M & L in replacement chequred rubber mat for electrical purpose ISI marked of size 1 mtr x 2 mtr and 19 mm thickness complete all as specified and as directed.
M & L for maintenance free chemical earthing using 40 mm dia 3.0 mtr long GI earthing electrode capsule complete as following: - (a) Making a hole of 150 mm dia to a depth of 3.50 mtr from GL and placing the earthing electrode inside the hole (b) Filling the back fill earth enhancing compound of superior quality qty appx 50 kgs properly mixed the water all around the earthing electrode (c) Continuously compaction of backfill compound to form a uniform mixture all around the earthing electrode (d) Construction of brick masonary earth pit of internal size 300 x 300mm and 300 mm deep with and incl finishing work and fixing of CI cover with frame complete all as specified and as directed. (e) Testing for proper working after completion, complete all as specified and directed.
S & F in replacement aluminium strip of size 40 x 5 mm thickness and connecting as directed incl drilling holes and nuts bolts of suitable size complete all as specified and directed.
S & F in replacement GI strip of size 32x6 mm thickness and connecting as directed incl drilling holes and nuts bolts of suitable size all as specified.
Supply, installation,commissioning and testing of CPRI approved make outdoor type floor mounting double door feeder pillar box of size not less than 1200 x 1200 x 450 mm , fabricated from 3.15 mm thick CRCA sheet and MC 75 for base channel, 04 nos legs 750 mm long made from 50 x 50 x 6 mm angle iron , dully powder coated, dust/water and water proof , grouted in PCC 1:2:4 type B-1 foundation, suitable for 415 volts, 3 phase, 4 wire , 50 Hz complete all as specified and directed with and including the following:- [a] Aluminium strip bus bar TPN sleeve insulated mounted on epoxy insulators of capacity 600 amps - 01 set. [b] INCOMING - MCCB FP 400 amps , 415 volts, 50 Hz, 35 KA with adjustable thermal and magnetic release and Ics=100% of Icu - 01 No. [c] OUTGOING - MCCB TP 200 amps , 415 volts, 50 Hz, 35 KA with adjustable thermal and magnetic release and Ics=100% of Icu - 02 No and MCCB TP 100 amps , 415 volts, 50 Hz, 35 KA with adjustable thermal and magnetic release and Ics=100% of Icu - 02 No. [d] Earthing terminals - 02 Nos and danger notice plate dully rivetted or pasted on front door - 01 No. [e] Digital voltmeter flush mounting type three phase 0-500 volt range size 96x96 mm - 01 No, Digital ammeter flush mounting type three phase 0-400 amps range size 96x96 mm - 01 No, LT CTs ratio 400/5 amps - 03 Nos, control wiring with single core copper cable FRLS of suitable size incl protection device for each circuit complete all as specified and directed.
Supply and fixing of AC power backup system for opeartion of power house equipements, comprising of 2 KVA capacity single phase power invertor with digital LCD display screen, having protection against overload and short circuit , with input voltage 100 to 285 volts and output voltage 220 Volts AC complete with 02 Nos tubular type batteries of capacity 12 Volts 150 AH, all connections with suitable size of copper conductor leads and cables, lugs etc all as specified and directed. Make- Luminous/Microtek/V-gaurd/Exide or equivalent makes specified in Appx 'B'.
S & F in replacement lightening arrestors HT 11 KV expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp complete all as specified and directed.
Disconnecting and taking out power back up system of any type and size complete all as specified and directed.
Disconnecting and taking out existing defective LT cable of any size complete including joints/protection pipes etc from trenches/ducts/poles etc complete all as specified and directed.
KATWAL TECHNOCRATS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .