Loading…
Loading…
Tender Value
₹6.8 L
EMD Value
₹13,680
Closing Date
3 Oct 2026, 4:00 pm5d left
Er Pawan Tickoo
Executive Engineer PWD RandB Division Jammu
Please Refer BOQ
2026_PWDJK_326275_1
e-NIT No. EDJ/ 110 of 2026-2027 Dated 28-09-2026
Open Tender
Electrical Works
Percentage
45 days
Reasi
Please to NIT
2 documents required · 2 mandatory
₹600
Executive Engineer PWD RandB Electric Div Jammu
₹13,680
Yes
28 Sept 2026
28 Sept 2026
5 Oct 2026
28 Sept 2026
3 Oct 2026
28 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | SITC of Spike Earthing through GI Rod Electrode of 1.5 mtr length (Complete Job) | 10 | Nos. | 950 | ₹9,500 |
| 2 | Supply, installation, testing & commissioning of GI Electrode Earthing with 50mm dia and 3 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendly GI Electrode Earthing should be maintinance free and does not require regular manual addition of water . The earthing pit should be covered with PVC cover. | 1 | Set | 13,200 | ₹13,200 |
| 3 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. | 12 | Mtr. | 287 | ₹3,444 |
| 4 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. | 10 | Mtr | 84 | ₹840 |
| 5Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required. | |||||
| 5.01 | 3 x 2.5 sq. mm | 160 | Mtr. | 148 | ₹23,680 |
| 6 | Providing installation, testing and commissioning of Double Door type main panel made of CRCA Sheet outdoor type, cubical feeder panel with 1.6 mm thick sheet painted from inside and outside to provide complete protection from water moisture, dust and vermin proof, duly wired up with the following accessories/equipment.
MCCB DP 100 amp 25 KA = 1 No.
Metering and Indication
Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set, MCB strips for required Nos. of MCB etc. = 1 set
Aluminum Busbar
High conductive electrolytic grade aluminium busbar of 240 Amp, TPN, with heat shrinkable sleeve, duly colour coded. =1 Set
Timer Switch
a) Timer Switch = 1 No.
b) MCB 6 amp to 32 amp = 8 Nos.
c) 1 x 1.5 sq. mm = 10 Mtrs. | 1 | Nos. | 28,000 | ₹28,000 |
| 7 | Supplying, Installation, Testing & Commissioning of 200 watt Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year
OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% | 62 | Nos. | 7,300 | ₹4,52,600 |
| 8Supplying & laying of PVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/pole alongwith clamps/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) including Al. Thimble, Nuts Bolts etc. of required sizes | |||||
| 8.01 | 35 sq. mm 2 core | 60 | Mtr. | 329 | ₹19,740 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.39 MB
BOQ_1103338.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .