| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.9 LAccepted-AOC 5 L LEHAL COLONY PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹25.9 L+₹1.0 L (4.15%)Rejected-Finance 602 TECHNOLOGY APARTMENTS 24 1 P EXTENSION DELHI 110092 | DELHI | DELHI | DELHI | 110092 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹27.8 L+₹3.0 L (12.0%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹31.9 L+₹7.0 L (28.3%)Rejected-Finance 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹33.9 L+₹9.0 L (36.2%)Rejected-Finance 4 KHEME KA KUA PAL ROAD JODHPUR RAJASTHAN 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹33.5 L
EMD Value
₹67,000
Closing Date
11 Sept 2021, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Jaisalmer
GE (AF) Jaisalmer
Provn of Miscellaneous E/M and allied works at Chandan at AF Stn Jaisalmer
2021_MES_468214_1
8760/GE/E8
Open Tender
Miscellaneous Works
Item Rate
120 days
GE (AF) Jaisalmer
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Jaisalmer
₹67,000
Yes
17 Sept 2021
14 Aug 2021
13 Sept 2021
14 Aug 2021
11 Sept 2021
26 Aug 2021
16 Aug 2021 - 21 Aug 2021
60 days
Amount
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc. or for laying of cables, pipes, erection of poles, structs/stays etc. or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 sqm on plan and getting out soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified.
Removal of excavated soil/ material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified.
Stone patti 40 to 50mm thick rough dressed Jodhpur stone slab cover in trenches for protection of cable 25 to 35cm wide and not less than 80cm in length laid dry abutting each other with gap between adjacent slab not exceeding 10mm over sand cushioning complete all as specified and directed.
Dry tibba sand cushioning to underground cable provided with a layer of 8cm deep before laying cable and 15cm after laying of cable and punned to 18cm after laying of cable and cover for protection of underground cable complete all as specified and directed. Notes :- (i) Approved dry sand free from vegetation, grass and other deleterious substances shall be used. (ii) For the purpose of payment only punned thickness shall be measured for payment.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volt grade cross sectional area 35 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/along poles complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volt grade cross sectional area 16 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/along poles complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volt grade cross sectional area 10 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/along poles complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volt grade cross sectional area 10 sqmm 2 core laid in trenches/ducts, through pipe, under floors or roads/along poles complete all as specified and directed.
Galvanized steel water tubing light grade of 40mm bore with & including all fittings complete with clamp of 25x3mm flat iron welded to pipe fixed to wall/ploe/ceiling or laid in floors or under road, complete all as specified and directed.
Cable Junction box made out of polycarbonate with IP 55/IP 65 protection of size 200mm x 160mm x 98mm, 5 way having terminals for termination of cable with necessary nuts and bolts including 02 Nos polycarbonate cable gland, 01 Nos DIN rail for mounting of MCB and including MCB, 6 Amps, Single Pole, rupturing capacity 10 kA, and including fixing clamp of FI 50 x 6mm with necessary nuts and bolts complete all as specified and directed.
LED flood lights not less than 120 watts, nominal voltage 240 volts, 50 Hz, high efficiency long life LED module with SMD LED package mounted on MCPCB, lumen efficacy of LED shall not be less than 95 lumen/W, Colour temp (CCT) -5700K and viewing angle of 120 degree to ensure better uniformity, epoxy powder coated pressure die cast aluminium housing elegantly designed heat sink for efficient thermal management, high quality toughened glass IK 07 fixed to housing, having electronic driver, integral, isolated electronic driver with lower THD, output open/short circuit protection, over voltage protection, surge voltage protection with external SPD not less than 10 KV and other safety test as per IS 15885 Part-2/Sec 13, having adjustable MS cradle of thickness 5mm provided with the fixture by 2 elliptical slots complete all as specified and directed.
Supply, fixing, connecting and testing LED bollard light decorative type with reflector not less than 10 watt, IP65 rated Inverted Pyramid Tripod type LED Bollard with soft 360 degree light distribution having fixing arrangements at bottom with necessary nuts, bolts, washers complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No. 3 of SSR Part-I and connection to main switch board/Test point/ panel/ equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exceeding 50 metre, charcoal and salt in alternate layer 15cm thick all around the earth plate electrode, Mild Steel Funnel with wire mesh, 20mm bore, GI pipe medium grade, 1.50 metre long for watering and 15mm bore, GI pipe light grade, 7.50 metre long for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:2:4) type B-1, using 20mm graded stone aggregate with angle iron 40x40x5mm frame 60mm thick RCC cover with 6mm steel bars 100mm centre to centre both ways etc complete all as specified & as directed. Note : (i) PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) If earth resistance of earthing is not found satisfactory it will be redone by the contractor on his risk and cost.
PVC insulated and fire retardant PVC sheathed, copper conductor of round cable size 1.5 sqmm, 3 core for electric connection from feeder /looping box /street light over head line to street light fittings complete all as specified and directed.
Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one coat primer, one under coat and one finishing coat of synthetic enamel paint complete all as specified and directed.
Polypropylene random copolymer concealed (PPR) Pipes, 3 Layer, UV stabilised having thermal stability upto 93 degree centrigrade complete and fixed with the pole by providing Flat Iron clamps, nuts and bolts of size 25x25x3mm with nuts & bolts for protection of connecting wires, connection from Junction box to light fittings complete for outer dia 20mm (PN-16) complete all as specified and directed.
Plain cement concrete (1:2:4) Type B-1 (using 20 mm graded granite stone aggregate) as in copping of poles including necessary form work and finished the surfaces complete all as specified and directed.
Supply, fixing, connecting and testing of Automatic street light switch using infrared sensor based nature switch for automatic switching of street lights, nature switch operation should be based on natural light lux level. Required illumination level for switching on is <30 lux and for switching off >10 lux. The sensor should also have part night operation facility for 4-12 hours. The sensor alongwith suitable power contactor, incoming-outgoing MCBs should be enclosed in a pole/wall moutaed enclosure made out of rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP-54. The circuit should be suitable enough to take 8 KW 3 Phase load with contactor 25 Amps conforming to IEC-60947-4-1/IS-13947-4-1 and incoming and outgoing MCBs of rating 32 Amps conforming to IEC-60898/IS-8828 and circuit wiring of minimum 10 sqmm copper conductor wire and including providing of 50x6mm flat iron clamp, necessary nuts and bolts, complete all as specified and directed. Make of nature switch - Model No Swadeep-02EC8kw3P of Kakatiya Energy System or equivalent make of Bajaj/Healer, Make for Contactor- BCH/L&T/Schneider, Make of MCBs- Hager/Schneider/L&T/C&S, Enclouser - Sintax or equivalent
On Load Changeover switch 250 Amp, 4 Pole, 415 volt, 50 Hz, sheet steel enclosure with front handle to be fixed on wall with flat iron 32x6mm including thimbles, nuts, bolts, washer etc complete all as specified and directed.
Sub main wiring with 4.00 sqmm, Single Core, PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 volts grade conforming to IS 694 including 4.00 Sqmm Single Core PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade as continuous earth wire in green colour drawn through in existing surface/recessed steel/PVC/steel rigid conduit complete all as specified. Note : Two run of 4.00 sqmm cable and one run of 4.00 sqmm cable as earth wire continuity conductor shall be measured & paid as one unit.
Sub main wiring with 6.00 sqmm, Single Core, PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 volts grade conforming to IS 694 including 6.00 Sqmm Single Core PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade as continuous earth wire in green colour drawn through in existing surface/recessed steel/PVC/steel rigid conduit complete all as specified. Note : Two run of 6.00 sqmm cable and one run of 6.00 sqmm cable as earth wire continuity conductor shall be measured & paid as one unit.
Sheet metal enclosures with socket plug top Single Pole and neutral encolsure with a two pin and earth plug with socket complete with one double pole MCB, 32 Amps rating with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 415 volt grade, AC supply, 50 Hz, complete all as specified and directed.
Galvanized steel water tubing medium grade of 15mm bore with & including all fittings complete to walls and ceilings or laid in floors, and including cutting of chases making good to concealed GI pipe etc,cutting not exceeding 10cm girth and making good to match the existing surface complete all as specified and as directed.
Angular stop cock fancy type with 15mm bore long shank and cup (concealed type) of cast copper alloy chromium plated screwed down, high pressure with capstan heads, screwed both ends for iron pipe or for union fixed complete all as specified and directed.
CP brass flexible connecting piece of size 15 mm for hot water and cold water complete connectin pipe complete all as specified and as directed.
Supply, installation and testing electric water heater, storage type, steel body with copper inner tank and heating element upto 2 KW, capacity 25 litre BEE 5 star rated complete with all assessories such as safety valve, thermostate, NRV, PVC connection pieces etc complete all as specified and directed.
LED foot lights/down lights not less than 2 watt with shutter 4 module complete all as specified and directed
Supply, fixing, connecting and testing, single phase, pressure pump of capacity 0.50 HP, 220 volts, 50 Hz suitable for boosting of water supply in bathrooms with automatic operation complete all as specified and directed.
20mm bore Gun-metal globe or gate valves (ISI marked), with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
25mm bore Gun-metal globe or gate valves (ISI marked), with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Supply, laying, jointing and testing 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor cable 10 sqmm, twin core, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire complete all as specified and directed.
Supply, laying, jointing and testing 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor cable 6 sqmm, twin core, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire complete all as specified and directed.
Sheet metal enclosure powder coated single phase DB SPN 12 ( ways and neutral 240 Volts, AC supply, 50 Hz, with 200 Amps rated bus bar Single Door (IP-43 IK 09 with metal door) suitable for fixing of MCBs including fixing of lugs in main incomming and outgoing line and fixing of cable glands of suitable size including grouting flush in the wall by means of nuts, bolts, angle iron and making good disturbed surfaces complete all as specified and directed.
Sheet metal enclosure powder coated single phase DB TPN 4 ways and neutral 415 Volts, AC supply, 50 Hz, with 200 Amps rated bus bar Double Door (IP-43 IK 09 with metal door) suitable for fixing of MCBs including fixing of lugs in main incomming and outgoing line and fixing of cable glands of suitable size including grouting flush in the wall by means of nuts, bolts, angle iron and making good disturbed surfaces complete all as specified and directed.
Sheet metal enclosure powder coated single phase DB VTPN 4 ways and neutral 415 Volts, AC, 50 Hz, with 200 Amps rated bus bar Double Door (IP-43) suitable for fixing of MCBs including fixing of lugs in main incomming and outgoing line and fixing of cable glands of suitable size including grouting flush in the wall by means of nuts, bolts, angle iron and making good disturbed surfaces complete all as specified and directed.
MCB, Single Pole, 6 to 32 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 240 Volt grade, AC supply, 50 Hz and making connections using suitable size copper lugs/thimbles complete all as specified & directed.
MCB, SPN, 40 to 63 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 240 Volt grade, AC supply, 50 Hz and making connections using suitable size copper lugs/thimbles, complete, all as specified & directed.
MCB, TPN, 40 to 100 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 415 Volt grade, AC supply, 50 Hz and making connections using suitable size copper lugs/thimbles, complete, all as specified & directed.
MCCB, 4 Pole, 63 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC supply, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, complete all as specified & directed.
Galvanized steel water tubing medium grade of 20mm bore with & including all fittings and complete, laid in trenches, on wall/roof and ceiling or laid in floors, complete all as specified and directed.
Galvanized steel water tubing medium grade of 25mm bore with & including all fittings and complete, laid in trenches, on wall/roof and ceiling or laid in floors, complete all as specified and directed.
Boring Hole/Drilling (Horizontally) under the road / pavement / hard standing with the help of trenchless and necessary machine for inserting Galvanised steel pipe of size 100/80mm not less than one metre below ground level complete all as specified and directed. Note : GI pipe shall be measured and paid for seperately in respective items.
Supply, Design, erection, testing and commissioning of outdoor type LT Bus Bar Chamber box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type Aluminium bus bars (32mm x 5mm) for looping & branch connection system .The chamber shall be painted with powder coated paint (Shade : RAL-7032) after 7 tank pre-treatment of surfaces. The bus bar chamber shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947 in and including providing of one No MCCB of 160 Amps, 4 Pole, 25 KA, 50 Hz 415 Volts complete all as specified and directed. Note: (i) The bus bar chamber shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate, front door (01 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom. The bus bar chamber shall be provided with ventilation facility in the form of louvers for better heat dissipation. (ii) The bus bar chamber Box shall be designed in such a way that adequate workable space is made available inside the compartments and the size of the chamber shall not be less than 500mm height (without base frame & canopy), 500mm width and 450mm depth)
Supply and fixing LED flood lights not less than 250 watts, nominal voltage 240 volts, 50 Hz, high efficiency long life LED module with SMD LED package mounted on MCPCB, lumen efficacy of LED shall not be less than 100 lumen/W, Colour temp (CCT) -5700K and viewing angle of 120 degree to ensure better uniformity, epoxy powder coated pressure die cast aluminium housing elegantly designed heat sink for efficient thermal management, high quality toughened glass IK 07 fixed to housing, having electronic driver, integral, isolated electronic driver with lower THD, output open/short circuit protection, over voltage protection, surge voltage protection with SPD not less than 10 KV and other safety test as per IS 15885 Part-2/Sec 13, having adjustable MS cradle of thickness 5mm provided with the fixture by 2 elliptical slots complete all as specified and directed.
Earthing complete with galvanished earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5 deep below normal ground level and connected to galvanished iron earth lead strip 32mmx6mm upto 7.50 metre, by means of GI nuts, bolt, check nuts, washers, thimbles, etc as shown in electrical plate No. 5 SSR Part-I and connection to main switch board or panel and testing on completion including excavation and earth work in any type to soil, returning fitting in and removal of surface spoil to a distance not exceeding 50 metre, PCC chamber (1:3:6) type C-2, charcoal and salt mixed layer 15cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe light grade 20mm bore for watering and 50mm bore GI pipe light grade for earth wire protection fixed with poles with two clamps, made from earth lead strip 32mm x 6mm, bolts, nuts and washers, 80mm thick pre cast RCC cover 1:2:4, type B-1, reinforced with hard drawn steel wire fabric wieghing not less than 4 Kg/Sqm in lieu of CI cover etc complete all as specified and directed. Note : (i) The unit rate shall be deemed to included for Test point, 32mmx6mm GI strip from top of the earth plate upto 7.50m above ground level. In case, GI protection pipe required is less than 7.50m, no price adjustment shall be made. (ii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junctions, elbow etc shall be deemed to be included in the unit rate quoted by the tenderer.
Supply, installation, commissioning and testing of latching High mast made up of galvanised special steel conforming to IS, ASTM- A- 572/BN -EN -10025 continuously tapered 12 sided polygonal cross section suitable for lighting system. it shall be suitable for wind speed as per IS-875, Part- 3, 1987 double section (section length 8300mm, thickness 4.3mm) of length approximately 16 meters to sustain as arising wind speed as per is 875 . An opening door shall be provided at the base that shall access to quipment installed in it in and including providing of double drum winch & cable Plug and socket, double lock paddle, raising & lowering mechanism, lantern carriage ring suitable to carry 09 Nos LED light of wattage above 250 watts, winch head frame, torque motor, limitor switch, cable trailing winch, aluminium Pulley, having three point suspension system with stainless steel wire rope AISI 316 grade, 6mm dia 97/19 construction in and including suitable terminal box shall be provided at base compartment of high mast for terminating incoming cables made up of special rubber trailing with EPR insulation and PVC sheathed & suitable power electrically driven tool shall couple with winch using sprocket motor mounted at base of mast with compartment one number heavy duty hot dip galvanised lighting finial shall be of 2 mtr in length shall provide centre of head frame, suitable earthing terminal at base minimum 12mm diameter GI nuts and bolts, base plate shall be not less than 570mm, 30mm thick & PCD 490mm, bottom of the high mast shall not be less than 410mm and top shall not be less than 150mm dia in and including providing foundation bolt manufactured from special steel and hot dip galvanised alongwith nuts and bolt fixing the same in PCC foundation and base plate of high mast complete all as specified and directed. Make of high mast :- Bajaj/CG/Wipro including the following :-
(a) Excavation, returning and filling in excavated soil, removal of surplus soil from site and depositing upto metre in low laying area as directed by Engr-in-charge at site (b) Material and labour for construction of foundation for 16 meter high mast considering the soil load bearing capacity not less than 10 ton/sqm at 2 meter depth, ( the contractor shall submit the foundation drawing with complete details for approval by the Engineer-in-charge before progressing the work at site as per manufacturer proposal) (c) Providing of suitable size and length of cable from terminal block in base of High mast upto LED light with the provision of rolling winch which can be operable at the time of taking down of light carriage from top to bottom. (d) LT Panel having incoming MCCB, outgoing MCCB/MCBs, time switch, contactor, indicator, voltmer suitable for controlling of electric supply of high Mast as per manufacturers design. (e) Aviation obstruction light, yellow painted die-cast aluminium alloy housing LED lights , heat resistent clear thick glass and accessories all as specified and directed connected electrically from LT feeder Pillar box to aviation lights of suitable length of size 2.5sqmm, 3 core industrial, copper flexible cable, lighting protection spike. Note : (i) The contractor will make the High Mast functional in all respect, if anything missed out, the contractor shall provide the same without any extra cost or claim to the department. (ii) The contractor shall submit warranty of material for two year from the date of certified date of completion
M/s Ramesh & Company
SS SODHA ENTERPRISES
SANJOLI CONSTRUCTION COMPANY
M.D. CONSTRUCTION CO.
S R ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .