Similar tender results from the same govt authority in the past 3 years.
S&T related cable shifting/utility shifting for facilitated engineering earth work for construction of fencing /ROB/RUB/LHS /Drain /Bridges repairing etc. in Gondia- Ballarshah section in NAG division of SECR.
ST-Cable-shifting-2R
ST-Cable-shifting-2R
Open
6 Months
Gondia, Maharashtra
₹0
₹1.4 L
22 Jun 2026
22 Jun 2026
1 Jul 2026
Description:- Laying of second class bricks including supply of required quantity at site on
cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost for item no.1 to 2 as mentioned above till commissioned.
consignee depot and meggering before loading and after laying, and recording the values in cable insulation register along with representative of Railways.
insertion, termination, wiring, testing & commissioning, two coat painting, lettering to suit the circuits as per approved wiring diagrams. This includes filling with sand and plastering the same.
Description:- Alteration of existing Q-series/Composite Relay Racks and cable termination racks.
Foundation- 30%,(ii) Errection - 15% ,(iii) Wiring, testing, painting, sand filling, plastering, earthing & writings etc - 45% ,(iv) Commissioning - 10% of the rate.
Description:- Collecting, stacking with deployment of Man power, Hydra etc for Loading/ Unloading
site to the stotre of SSE(SIG)/CON,(iii) any store depot to any other store depot over Indian railways as decided by Railway Administation by suitable Trucks and stacking properly.
NAGPUR-SECR-DIVISION-S AND T/SOUTH EAST CENTRAL RLY Description:- Track crossing, Road Crossing by pushing method (HDD method) at culverts/ track /
including supply of HDPE pipe/DWC pipe(4 inch dia) .NOTE : (1) This includes guarding of cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost for item no. as mentioned above till commissioned.
Description:- Installation, testing and commissioning of sliding boom LC gates complete which includes casting of concrete foundation including surrounding earthwork along the foundation (Dia-
cutting of rail post, fixing of lock post with two numbers excavation of Pit casting of concrete foundation for "B" type foundation per gate, laying of cable for road crossing and fixing of MS plate/channel also as requirement of the site condition.
Description:- Supply of Unskilled labour for immediate restoration of normal traffic by jointing
department or for shifting, stacking of stores materials. Unskilled staff will remain available in working hours.
digging for diversion of cables in connection with cable clearance for engineering earth work without interfering the circuits as per the advice of Railway site engineer
relocation the Location Box/ Signal Post with foundation as per the advice of Railway site engineer. S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Above/ Schedule () B-Supply of Signal Items 194803.00 Below/P ar
conductor16/0.2 mm dia. (80% grey & 20% yellow) as per the colour coding scheme of Railways. Spec. no: IRS-S-76/89 with latest ammendment. Inspection by Rep. of Sr. DSTE/CO/ NAG
accessories along with engineering and operating manual. Inspection by Rep. of Sr. DSTE/CO/NAG
manufacturer calibration test certificate, Nippen make or similar, Range : 500 Volt , 200 M Ohms. Inspection by Rep. of Sr. DSTE/CO/NAG
Inspection by Rep. of Sr. DSTE/CO/NAG
Description:- Supply of Wago / phoneix terminal blocks (Part no.280-874). 4 conductor disconnect terminal block.(i) 4 conductor disconnect terminal block for test and measurement; 0.08 mm.sq.- 2.5mm.sq., Center marking with slot test for test plug dia 2mm/0.079 In and dia 2.3mm/0.091 in; Carrier rail din 35: front-entry; with knife disconnect large cage clamp connection, grey. (ii) End and
end stop for carrier rail (iv) steel carrier rail;35 X 7.5 mm, 1 mm /0.039 in thick; unslotted (Part no. 210-229/ PW11-0000). (v) WSB quick marking system; horizontal; 1 ... 10 (10x); for width 5-17.5 Mm; 10 strips of 10 marker per strip (100) per card; consecutive numbers white (Part no. 209 - 502S). (vi) Adjacent jumper nominal current 24A; Insulated Grey. Inspection by Rep. of Sr. DSTE/Co/NGP S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Above/ Schedule () C-Execution of Telecom Items 3568775.00 Below/P ar
NAGPUR-SECR-DIVISION-S AND T/SOUTH EAST CENTRAL RLY
including clearing of roots bushes etc. for all types of soils including morrum, hard soil mixed with boulders etc. This work include back filling the trench, ramming, consolidation of soil as well as disposal of extra soil after cable is placed in the trench. After mansoon the route is to be attended for back filling the rain cuts, wash out of soils where ever found.Depth 1.0 Mtr. & Width 0.3Mtr. The work is to be executed as per Railway site Engineer.
Description:- Laying of Quad Cable, PIJF cable of different sizes, power cable of different size in the excavated trench, inside GI,RCC and HDPE pipes. This includes loading/unloading & transportation of
categories have to be laid in the same trench/path, the provision of seperation of various cable should be as advised by the site incharge of the Railway. Empty cable drums to be returned by the contractor.The cable drums with unused cable at site to be returned by the contractor from site to Stores depot . The work is to be executed as per Railway site Engineer.
Description:- Transportation & Execution of following kinds of joints on Quad Cable using
in all types of soil for jointing of copper cables, back filling and ramming after jointing.straight through joint on Quad cable/10-20-50 pairs PIJF Cable. The work is to be executed as per Railway site Engineer.
Description:- The excavation of pit, casting of concrete foundation including surrounding earthwork along the foundation, erection, installation and wiring of steel appartus case, fixing of terninals, fuse blocks, signal transformer, current transformer, filament switching unit, track battery chargers, adjustable /fixed resistances, choke coils, Fuses, Relays, E type locks , termination of cables, cable insertion, wiring to draw 110V AC therefore in the new apparatus case as required, testing,
armours etc. Painting of the apparatus case inside and outside after clearing the surface thoroughly and first coating of anti -corrosive paint and subsequent two coatings of Alluminium paint outside and Red Oxide inside and lettering. 18 mm Hylum sheet for location box shelf and 12 mm forcable termination in location box.Steel appartus case (Large) to Drg.No. CON/SK/T/8 with 4 Nos. of foundation bolts 20mm x 460mm to Drg.No. SA-112 A/M or latest. The work is to be executed as per Railway site Engineer.
Description:- Transportation including loading/unloading of HDPE pipe from the stores of railway to
excavated trench/already laid GI/RCC pipes/tubes, jointing, levelling and end ealing e pipes. The work is to be executed as per Railway site Engineer.
Description:- Transportation, loading/unloading of OFC from the stores of railway to the work site with care, pushing/pulling OFC through the HDPE pipes, sealing of the duct by sealling /caps plugs. The cable is to be laid by mechanised means. At inaccessible places where mechanised laying is not
testing of cable drums in the store premises before transportation and submissions of results thereof. Empty cable drums to be returned by the contractor. The cable drums with unused cable at site to be returned by the contractor the stores depot . The work is to be executed as per Railway site Engineer.
Description:- Transportation, installation of optical fibre joint closure and splicing of Optical fibre cable (2 x 24 fibres) and testing, Optical fibre cable splicing shall be done in the presence of Railway's representative. Only joint closure shall issued by the Railway. All other tools/test
construction of masonary pit of bricks (inside complete plastered), the inner size of pit 1.2m x 1.2m (depth 0.75m) in all types of soils for keeping cable coils at the location of OFC joints, filling the pit with sand after jointing of cables, ramming nd covering with RCC slab as per Drg. and instructions of site incharge of Railway.
Description:- Laying and Fixing of galvanised iron pipe (GI Pipe) with threaded collars (for jointing pipe) of 80 mm nominal dia Spec.No.IS-1239 medium grade, on bridges, culverts, drains including
Drg.No.Con/SK/T/2 and drawing of Signal/ Power/Quad cables inside the pipe with masonary works over the entire length of the bridge and at entry and exit of the culvert and curing for 72 hrs, drilling of holes on the pipe at 10 cm apart to be clamped 2 Mtrs apart on culvert, for the Signalling, quad, power cable. The work is to be executed as per Railway site Engineer.
9 NAGPUR-SECR-DIVISION-S AND T/SOUTH EAST CENTRAL RLY 9 Description:- Track crossing, Road Crossing by pushing method (HDD method) at culverts/ track / pucca road crossing at a depth not less than 1 meter with reference to bottom of rail/road surface including supply of GI/HDPE pipe .(b) GI pipe with 76 mm dia, Spec. No. -1239 medium grade (for the length of pushing more than 05 meters). The work is to be executed as per Railway site Engineer.
below. The work is to be executed as per Railway site Engineer.
Description:- Excavation of earth pit, transportation, placing and fixing of earth electrode with
wrapped on MS strip (35 x 6 mm) from earth electrode to all signalling equipments, including fixing and soldering of lugs at both end of the wire. The work is to be executed as per Railway site Engineer.
Description:- Laying of RCC pipe including supply of required quantity at site with collars (for
Power cable/PIJF cable/ Quad cables/HDPE pipe through RCC pipe. Power cable shall be laid in the same trench along with signalling/Quad cables but in a separate pipe RCC pipe at track/ pucca road/ Platform crossing/ level crossing gate etc. The work is to be executed as per Railway site Engineer.
Description:- Fixing of concrete cable route marker at 30-40 meter and at diversion point including
should be followed as per drawing no. SDO/Cable laying/020. The work is to be executed as per Railway site Engineer.
Description:- Excavation of trenches including clearing of roots of trees etc. in hard/rocky soil by
RCC hume pipe section as per drawing on sieved soil of 30mm over cable / HDPE pipe and concreting through - out the length upto a layer of 75mm. Then back filling the trench and then ramming of soil .The work is to be executed as per Railway site Engineer. S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Above/ Schedule () D-Supply of Telecom Items 2810763.76 Below/P ar
lock on both side having ward No.32. Material Inspection: consignee
Description:- Supply of permenantly lubricated HDPE pipe with outer dia 50mm, inner dia- 42mm
08/01 Dec. 1999. Supply to be made in length of 500 mtrs with + /-10% tolerance. Material Inspection: Consignee.
Description:- Supply of Optical fibre joint closure for straight through joint with modification for 24
accessories (sealing with mechanical clamp facility) make Raychem or similar. Material Inspection: CONSIGNEE
Power Meter With VFL & RJ45 Network Tester, FC, SC, ST Connectors . Make: Syrolink, STAR or Similar.Material Inspection: CONSIGNEE.
manufacturer calibration test certificate, Nippen make or similar,Range : 100 Volt , 100 M Ohms. Inspection by Rep. of Railway Engineer.
Inspection: CONSIGNEE
NAGPUR-SECR-DIVISION-S AND T/SOUTH EAST CENTRAL RLY Description:- Supply of Handheld DigitalEarth Clamp Tester for clampon earth/ground
current leakage up to20A. No spines required formeasurement Model - DECT-2or equivalent / higher version make Motwane/Stanlay /Fluke/Megger..Material Inspection: CONSIGNEE
Inspection: CONSIGNEE
size0.6mm. Dia annealedcopper conforming to IRS-TC-24/91 or ITD 1138.Inspectionby Rep. of Railway Engineer.
Description:- Supply of Cable Route locator, make- 3M Dynatel, Model no- 2250- U3P3 / RD-7200
fibre optics having specification:- Coupler Size 3.00 Inch; Direct Connect Cable- Large Clips; Number of Frequencies- 4; Operating Temperature Range -20 to 50 Degree Celsius; Storage Temperature -40 to 70 Degree Celsius;Transmitter Output- 3 Watt. Inspection by Rep. of Railway Engineer.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC April 2022
ATTACHMENT
REVISED_FORMAT_Annexure-VVA.pdf
ATTACHMENT
Annexure-VIB.pdf
ATTACHMENT
AnnexureM-BlacklistingM.pdf
ATTACHMENT
AnnexureNBidsecuritydeclarationN.PDF AnnexureN
ATTACHMENT
AnnexureL
ATTACHMENT
CorrectedFinal_GCC_April-22140722_compressed.pdf
ATTACHMENT
AnnexureNBidsecuritydeclarationN.PDF
ATTACHMENT
Annexure-JforCertificateofRtd.EmployeeJ.PDF
ATTACHMENT
Download all tender documents and submit your bid