Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.3 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹27.9 L+₹13,987.80 (0.50%)Rejected-AOC | L2 | Rejected-AOC Other than Lowest Bidder | |
| 3 | L3₹28.4 L+₹73,052.30 (2.64%)Rejected-AOC | L3 | Rejected-AOC Other than Lowest Bidder | |
| 4 | L4₹30.8 L+₹3.1 L (11.1%)Rejected-AOC | L4 | Rejected-AOC Other than Lowest Bidder | |
| 5 | L5₹31.2 L+₹3.5 L (12.5%)Rejected-AOC | L5 | Rejected-AOC Other than Lowest Bidder |
Tender Value
₹28.5 L
EMD Value
₹57,000
Closing Date
12 Jan 2022, 6:00 pmClosed
Garrison Engineer (South) Jaipur
Garrison Engineer (South) Jaipur Military Engineer Services Kalyan Marg, Jaipur302006
PROVN OF STREET LIGHTS FROM VIJAY DWAR TO GATE NO 2 AND PROVN OF FLOOD LIGHT AT 61 CAV AND SPL REPAIR TO LT OH TO UG CIRCUIT AT PCDA COLONY IN ZONE-III AREA UNDER GE(S) JAIPUR AT MIL STN JAIPUR
2021_MES_495580_1
GE(S)/J-56P OF 2021-22 8697/E8
Open Tender
Civil Works
Item Rate
180 days
Jaipur
Class D category
b(i)
9 documents required · 9 mandatory
₹500
GE (S) Jaipur
₹57,000
Yes
24 Feb 2022
17 Dec 2021
17 Jan 2022
17 Dec 2021
12 Jan 2022
7 Jan 2022
Amount
Excavation in trenches n.exc 1.5metre wide and n.exc 1.5 metre in depth for foundation etc or for laying of cable etc and getting out in soft/loose soil 01/SR - 309 08/REV - 97 01/LBW - 248.4
All as per the description of serial item 1 here in before but depth exceeding 1.5 meter and n.exceeding 3.00 meter. 01/SR - 0.2 08/REV - 0.4 01/LBW - 1.2
M & L Sand cushioning to PVC under ground cable with tibba sand, screened and washed sand and punning to provide a required cover. 01/SR - 93 08/REV - 29 01/LBW - 75
M & L Bricks for protection cover to under ground cable (with old size sub class ‘B’ bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10 mm as directed by Engineer-in-Charge. 01/SR - 9.9 08/REV - 3.1 01/LBW - 8.0
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm in depth. 01/SR - 178 08/REV - 62 01/LBW - 143.3
Removing of excavated material (soil) to a distance n.exc 50 metre and depositing where directed at a level n.exc 1.50 metre above the starting point 01/SR - 131 08/REV - 35.4 01/LBW - 106.3
M & L for Supplying, laying, connecting and testing in trenches, under floors/ roads or on walls Cable XLPE insulated screened PVC bedded galvanized steel strips or wire armored, electric power cables (heavy duty) ISI marked with stranded aluminium conductor, 1100 volts grade of following sizes:
16 Sqmm, 4 core 01/SR - 500 08/REV - 500 01/LBW - 1050
25 Sqmm, 4 core 01/SR - 180 08/REV - 100 01/LBW - 100
35 Sqmm, 3 1/2 core 01/SR - 200 08/REV - 0 01/LBW - 0
50 sqmm, 3 1/2 core 01/SR - 250 08/REV - 0 01/LBW - 0
70 sqmm, 3 1/2 core 01/SR - 150 08/REV - 0 01/LBW - 0
95 Sqmm, 3 1/2 core 01/SR - 100 08/REV - 0 01/LBW - 0
120 sqmm, 3 1/2 core 01/SR - 50 08/REV - 0 01/LBW - 0
S&F for 1100 Volts grade heavy duty cable PVC insulated aluminium conductor cable with inner sheathing of PVC tape and overall PVC sheathed in service connection three core stranded aluminium conductor of size 4 sqmm ISI marked drawn through steel pole from junction box to street light fitting or for OH connections complete all as specified and directed. 01/SR - 150 08/REV - 0 01/LBW - 0
S&F rigid non metallic PVC conduit 20 mm dia exclusive of boxes (junction/terminal) but inclusive of all tees,bends,elbows,reducers,bell mouth ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. 01/SR - 100 08/REV - 0 01/LBW - 0
M&L earthing complete as per electrical plate No. 3 of MES SSR Part-I with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less then 1.5 metre below normal ground level connected to and including galvanised iron or steel earth strip 32 mm x 6 mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 40 mm bore light grade and connected to continuous earth wire on pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cover complete all as specified & tested complete. 01/SR - 12 08/REV - 0 01/LBW - 0
Supply and fixing LED street light 100 W fitting comprising of pressure die cast aluminum housing with toughened glass of system, lumen efficiency> 90 lumen/watt complete with electronic driver for vibration proof performance having P.F.>0.95, operating voltage range 120 to 270 volts, THD< 10%, internal surge protection of 5 KV(in driver) and additional external surge arrestor of 10 KV for surge protection, driver protection-short circuit, open circuit, No-load, over load,EMI,CCT 5700 K and CRI> 70,IP 66, incl clamps, fastners complete all as specified and as directed. 01/SR - 30 08/REV - 0 01/LBW - 56
Supply & install steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410-SP-31 (9.00 meter long) including painting outside complete all as specified and as directed. 01/SR - 6 08/REV - 12 01/LBW - 28
M&L for GI pipe bracket 40 mm bore double swan neck shape on a single pole suitable to fix on top of tubular pole complete with nuts, bolts and washers complete all as specified and directed. 01/SR - 6 08/REV - 0 01/LBW - 28
Supply, install, testing & commissioning LT feeder pillar box (KIOSK) outdoor type, plateform mounted, compartmentalised and confirming to IP-54 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system all as specified and directed having busbar chamber with insulated copper busbars 100 Amps rating installed on porcelein insulators. The panel shall be dust and vermin proof, made of 3.15 mm CRCA MS sheet and with base frame of 40x40x5 mm angle iron, powder coated finish over two coat of red oxide primer, front and rear opening type with aprons for cable entry with double door shutter and locking arrangement including a lock with two keys, internal wiring with PVC insulated multi stranded copper conductor cable,FRLS cables ISI marked of adequate size but not less than 4 Sqmm. The scope of work include following:- (a)Astronomical time switch - 01 Nos (b) 4 pole 40 Amp contactor- 02 Nos (c) Toggle Switch - 01 No (d) TPN MCB 40 Amp- 02 No. (e) 4 Pole 63 Amp MCCB-01 No. (f) Glass Fuses (g) Neutral link (h) Push Buttons (i) LED indicating lamps (R, Y & B) -01 Set. 01/SR - 1 08/REV - 0 01/LBW - 0
S&F for thermoplastic, polystyrene unbreakable junction box size 260x210x116 mm suitable for pole mounted outdoor type IP 65 insulated complete with FI clamps & nuts, bolts, washers and including terminal block heavy duty with phase seperators between R,Y,B terminals, one MCB SP 6 amp 10 kA,all duly fixed on din channel, cable glands for cable entry complete all as specified and directed. 01/SR - 30 08/REV - 16 01/LBW - 28
M&L for drilling hole under road for laying of U/G cable through pipe of suitable size complete all as specified and directed at site. Note : GI pipe shall be measured and paid separately. 01/SR - 90 08/REV - 0 01/LBW - 0
M&L for galvanised steel tubing light grade for protection of under ground cable on poles/walls/floor, under road crossing etc IS-1239 marked complete all as specified and directed and of following sizes:-
(a) 50mm bore 01/SR - 50 08/REV - 0 01/LBW - 0
(b) 80 mm bore 01/SR - 40 08/REV - 0 01/LBW - 0
Supply & fixing LT cable route indicator cast iron of suitable size along LT cable trench including painting and grouted in ground in PCC complete all as specified and directed by Engineer-in-Charge 01/SR - 25 08/REV - 0 01/LBW - 0
M&L for cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation to poles complete all as specified and as directed. 01/SR - 2 08/REV - 4.3 01/LBW - 12
M&L for cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in coping to poles including necessary form work as required complete all as specified and directed. 01/SR - 0.2 08/REV - 0.75 01/LBW - 2
Taking out old U/S LT cables from existing LT panel to feeder pillar /busbar chamber/DBs of different size. 01/SR - 800 08/REV - 0 01/LBW - 0
Taking out old U/S LT Panel of different type /size. 01/SR - 5 08/REV - 0 01/LBW - 0
S&F heavy duty PVC insulated aluminium conductor 1100 Volts grade cable with inner sheathing of PVC tape and overall PVC sheathed in service connection three core stranded aluminium conductor of size 2.5 Sqmm ISI marked drawn through steel pole from junction box to street light fitting complete all as specified and as directed. 01/SR - 0 08/REV - 110 01/LBW - 300
Taking down street/ flood light (of any rating) , bracket, angle clmaps nuts and bolts of from the existing pole safely without damaging and deposited to MES storeyard. Note :- Necessary credit RV to be prepared & recorded in MB. 01/SR - 0 08/REV - 13 01/LBW - 0
M&L for GI pipe bracket 40 mm bore single swan neck shape suitable to fix on top of tubular pole complete with nuts, bolts and washers complete all as specified and as directed.Note:- The lower part of the bracket should be on the top of the pole tightly clamped with nuts and and bolts and angle with its height extending minimum of .8 mtr from the top of the pole and neck of the bracket should be at an angle of around 25 degre to 30 degree from the vertical height. 01/SR - 0 08/REV - 21 01/LBW - 0
Supply and fixing LED street light 250 W fitting comprising of pressure die cast aluminum housing with toughened glass of system, lumen efficiency> 110 lumen/watt complete with electronic driver for vibration proof performance having P.F.>0.95, operating voltage range 120 to 270 volts, THD< 10%, internal surge protection of 5 KV(in driver) and additional external surge arrestor of 10 KV for surge protection, driver protection-short circuit, open circuit, No-load, over load,EMI,CCT 5700 K and CRI> 70,IP 66, incl clamps, fastners complete all as specified and as directed. 01/SR - 0 08/REV - 27 01/LBW - 0
Supply, install, testing & commissioning LT feeder pillar box (KIOSK) outdoor type, plateform mounted, compartmentalised and confirming to IP-54 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system all as specified and directed having busbar chamber with insulated copper busbars 63 Amps rating installed on porcelein insulators. The panel shall be dust and vermin proof, made of 3.15 mm CRCA MS sheet and with base frame of 40x40x5 mm angle iron, powder coated finish over two coat of red oxide primer, front and rear opening type with aprons for cable entry with double door shutter and locking arrangement including a lock with two keys, internal wiring with PVC insulated multi stranded copper conductor cable,FRLS cables ISI marked of adequate size but not less than 2.5 Sqmm. The scope of work also includes following alongwith PCC foundation complete all as specified and directed:- (a)Astronomical time switch - 01 Nos (b) 4 pole 40 Amp contactor- 01 Nos (c) 4 Pole 40 Amp MCCB-01 No. (d) Toggle Switch - 01 No (e) Glass Fuses (f) Neutral link (g) Push Buttons (h) LED indicating lamps (R, Y & B) -01 Set. 01/SR - 0 08/REV - 0 01/LBW - 1
M&L earthing complete as per electrical plate No. 3 of MES SSR Part-I with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less then 1.5 metre below normal ground level connected to and including galvanised iron or steel earth strip 25 mm x 4 mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 40 mm bore light grade and connected to continuous earth wire on pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cover complete all as specified & tested complete. 01/SR - 0 08/REV - 0 01/LBW - 2
Taking down old ACSR conductor of any type from LT poles.
Taking down cross arm, nuts & bolts .
LAKSHMI ASSOCIATES
JAGDAMBA CONSTRUCTION COMPANY
M/S TRADE LINKERS
M/S JALANDRA CONSTRUCTIONS
M/S Anil Enterprises
RAAPS CONSTRUCTION
GLOBAL ENGINEERS AND INNOVATORS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .