Loading…
Loading…
Tender ID
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹7.1 LAdmitted-Finance | L1 | Admitted-Finance | ||
| 2 | L2₹7.2 L+₹9,062.18 (1.28%)Admitted-Finance | L2 | Admitted-Finance | ||
| 3 | L3₹7.4 L+₹28,270.06 (3.98%)Admitted-Finance | L3 | Admitted-Finance | ||
| 4 | L4₹7.5 L+₹37,036.73 (5.21%)Admitted-Finance | L4 | Admitted-Finance |
Tender Value
₹9.8 L
EMD Value
₹19,700
Closing Date
2 Feb 2026, 4:00 pmClosed
Executive Engineer PWD Division Poonch
Executive Engineer PWD Division Poonch
Construction of Sub Centre Bagyaldara,Pyt Bagyaldara,Block Poonch
2026_PWDJK_301264_3
e-NIT No.108/2025-26 dated 24-1-2026
Open Tender
Civil Works
Percentage
45 days
Poonch
Please refer Tender documents.
3 documents required · 3 mandatory
₹600
Yes
Executive Engineer PWD Division Poonch
₹19,700
Yes
6 Feb 2026
24 Jan 2026
3 Feb 2026
24 Jan 2026
2 Feb 2026
24 Jan 2026
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed:All kinds of soil :
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation/plinth & superstructure above plinth level upto floor five level including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand)
Dumping stone including cost of stones. On Horizontal on level.
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering .All work up to plinth level with :1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc.complete.50 mm thick with 20mm nominal size stone aggregate.
Chequerred precast cement concrete tiles 22mm thick in footpath and courtyard, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing, cleaning and curing complete, on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand) .Light shade using white cement
Reinforced cement concrete work in walls (any thickness) including attached pilasters,buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering,finishing and reinforcement.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D or more.
12mm Cement plaster of mix:1 : 6 ( 1 cement : 6 fine sand)
15 mm Cement plaster on the rough side of single or half brick wall of mix :1 : 6 ( 1 cement : 6 fine sand)
6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand)
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately):Sal wood
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS: 3818 marked with necessary screws.
With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work
Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc.complete as per the architectural drawings and the directions of engineerin-charge. (Cost of aluminum snap beading shall be paid in basic item.) With floating glass panes of 4.0 mm thickness (weight not less than 10.00 kg / sqm)
Providing and fixing ISI marked oxidized M.S. tower bolt black finish, (Barrel type) with necessary screws etc complete.
Providing and fixing ISI marked oxidized M.S. handles conforming to IS : 4992 with necessary screws etc. complete :
Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931
Providing and fixing ISI marked oxidized M.S. sliding door bolts with nuts and screws etc. complete :
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge.Male Thread Tee.For 22.22 mm outer dia x20 mm nominal dia threaded
Providing and fixing installing testing & commissioning of ISI marked electric storage water heater (Geyser) of 35 Ltr capacity 2000 W complete with all fitting electrical & plumbing connection as per specification and directions of Engineer-in-Charge
Centering and shuttering including strutting, propping etc. and removal of form for:
Foundations, footings, bases of columns etc. for mass concrete.
Lintel, beams, plinth beams, girders, bressumers and cantilevers.
Suspended floors, roofs, landings, balconies and access platforms.
Edges of slabs and breaks in floors and walls Under 20 cm wide
Carriage of material by M.T incl loading/unloading & stacking complete
Sand /Stone agg. below 40 mm nominal size avg. lead 15 km by MT and 50 Mtr by H.L
Bricks for an avg. lead 225 km by MT and 50 Mtr by H.L
Wiring for light point\fan point\call bell point with 1.5 sq. mm. FRLS PVC insulated copper conductor singel core casbel in furface \recessed medum class pvc conduit with modular switch , modular plate, suitable G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper comnductor singel cabel etc as req.
Wiring for light\power plug with 2x4 sq. mm FRLS PVC insulated copper conductor singel core cabel in surface\recessed medum class PVC conduit aslong with 1 no. 4 sq. mm. PVC FRLS insulated copper conductor singel core cabel in for loop earthing as req.
Wiring for cicuit/ submain wirring alongwith earth wire with the following size of FRLS PVC insulated copper conductor 'singel core cabel in surfacr/ recessed medum class PVC conduit as req
2x1.5 sq. mm +1x1. sq.mm earth wire
2x2.5 sq.mm+1x2.5sq.mm earth wire
2x4.0sq.mm +1x 4.0 sq. mm rarth wire
4X16 sq mm+2x 6.0 sq.mm earth wire
Supply and drawing following size of FRLS PVC insulated copper conductor 'singel core cabel in surfacr/ recessed medum class PVC conduit as req.1x1.5 sq. Mm
Supply and fixing of follo following size medum class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed comduit as req.25 mm
Supply and fixing following modular switch/socket on the exisitying modular plate & switch box including connections but excluding modular plste etc. as req
5/6 amp switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Supply and fixing two module steped type electronic Fan regulator on exisiting modular plate switch box including connection bu excluding modular plate etc as req.
Supply and fixing modular blanking plate on existing modular plate &switch box excluding switch box etc. as,req.
Supply and fixing suitable G.I.box with modular plate and cover in front of surface or in recess, includijng providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch,connection etc as req.
Supply and fixing suitable G.I.box with modular plate and cover in front of surface or in recess, includijng providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and15/16 A modular switch,connection ,painting,etc as req
Supply and fixing suiutable size of GI box with modular plate and cover in forent of surface or in recess,including providing and fixing 2 nos. 5/6 A modular socket outlet and 2 nos. 5/6 A modular swuitch, ,connection etc as rwq. (for light plug to be used in non residential buldings)
Supply and fixing following size/module GI. box alongwith modular base & cover plate for modular switches in recessed etc.as req.
1 or 2 module (75 mmx75mm)
3 module (100mmx75mm)
8 module(125mmx125mm)
Supply and fixing following way,horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V. on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, intreconnection, powder painted including earting etc. as req. ( but without MCB/RCCB/isolator)
4 way(4+12) Double Door
6 way(4+18) Double Door
Supply and fixing of following electrical items as req
Single pole
Single pole and neutral
Supply and fixing rating, four pole 415 V isolator exisiting MCB DB complete with connection, teasting and commessoning etc. as req.
Supply and fixing of following electrical items as req
A/B holder
LED lamp 9 watt
Celling fan 1200 mm swip alongwith rod upto 2'long as req.
Exhust fan 300 mm swip
Providing and fixing of IP-20 SMD mid powerLED batten type integrted light fixture made from power coated Extruded alum. housing with in built driver, complience 2.5 KV surg protected isolated driver, with short and open circuit protection .having efficiency .85% system lumin efficacy of ≥110 lm/ Watt,THD< 10%, PF ≥ 0.95, Cri.80, life time of minimum 50000 Burning Hours with 70% of intial Lumen maintained till life ends, CCT 3000°K/4000°K/5700°k/6000°/6500°K(A per ANSI Bin) , maximum power consumption should not more then the specified rating and fixture shell be of BIS standard and teade mark certificate (T.C) Manufacture word Mark / Name Engraved/Embossing/Screen Printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 &Lm80) certificate /report from OEM shall be submitted. all as per approved by EIC. 20/22 Watt LED 4 feet with min. lumen output (2000-2200) lm
Earthing with GI Earth pipe 4.5 mtr long 40mm dia including acessories andproviding mesonery enclouser with cover plate hasving locking arrangment and watering pipe (but wthout charcool/salt) etc as req.
providing and fixing of IP-20 Recessde/ surface mounted round / sqaure SMD mid power (18 watt)LED Downlight with power coated die-cast alum. housing with UV stabilized non yellowish Diffuser withBIS complience 2.5 KV surg protected isolated driver, with short and open circuit protection .having efficiency .85% system lumin efficacy of ≥110 lm/ Watt,THD< 10%, PF ≥ 0.95, Cri.80, life time of minimum 50000 Burning Hours with 70% of intial Lumen maintained till life ends, CCT 3000°K/4000°K/5700°k/6000°/6500°K(A per ANSI Bin) , maximum power consumption should not more then the specified rating and fixture shell be of BIS standard and teade mark certificate (T.C) Manufacture word Mark / Name Engraved/Embossing/Screen Printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 &Lm80) certificate /report from OEM shall be submitted. all as per approved by EIC.
Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI- EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
Earthing with GI Earth pipe 4.5 mtr long 40mm dia including acessories andproviding mesonery enclouser with cover plate hasving locking arrangment and watering pipe (but wthout charcool/salt) etc as req.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.86 MB
Tendernotice_2.pdf
PDF • 0.92 MB
BOQ_977512.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .