| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.9 LAccepted-AOC 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.4 L+₹1.2 L (5.20%)Rejected-Finance 111 GB MARG YADAV ELECTRIC MARKET LUCKNOW UP 226018 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226018 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹24.6 L+₹1.4 L (6.07%)Rejected-Finance 00 BAJRANG CHOK MAHOBA MAHOBA UTTAR PRADESH 210427 | MAHOBA | UTTAR PRADESH | 210427 | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹27.4 L+₹4.2 L (18.0%)Rejected-Finance | L4 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
6 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) BKT
GE (AF) BKT, LUCKNOW
COMPREHENSIVE REPAIRS AND RENEWALS OF SECURITY LIGHTS, FANS AND INTERNAL WIRING AND OTHER CONNECTED WORKS AT AF STN BKT
2023_MES_598971_1
8713/BKT/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) BKT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) BKT
₹60,000
Yes
9 Sept 2023
27 May 2023
8 Jul 2023
27 May 2023
6 Jul 2023
24 Jun 2023
Amount
Material, labour & T&P for carring out comprehensive repair/ maintenance of road/perimeter lights/ flood lights in technical and domestic area including TRU & Indourabagh appx 1290 Nos light for maintaining 95 to 100% serviceability of lights on poles / pillars tec max 9 mtr in height by checking, rectifying defects/ replacement if required (parts & new lights shall be paid seperately) including insulation tap, minor copper wires cable for internal connection, lugs etc tightening of junction fox in pole from daily 0800 to 2000 hrs by trained electrician and helper including sunday and holiday it may be more to maintenance required percentage of serviceability of security lights. Daily maintenance of security light 95 to 100% is measured as one job. Notes :- (i) All safety tools shal be provided to electrician by the contractor at own enperse and having insurance to covered, injury and helth hazard including death form valid compony. (ii) Ladder/ conveyance shall be provided to employed person. (iii) No adnroid phone shall be permitted inside Technical area. (iv) Excavation, taking out cable, relaying of cable up to 5 mtr from pole either side shall be deemed to be included in the rate quoted. (v) If tradsemen found absent recovery will be made @ double the quoted rate for this items
Taking out unserviceable LT cable of any size from trenches/duct etc carefully including bricks and keeping in safe custody either for relaying or disposal complete all as specified & directed
Supply, laying jointing and testing 16 Sqmm 4 core XLPE insulated LT under ground cable, 1100 volts grade heavy duty, armoured with multi stranded aluminium conductor laid in trenches/ ducts pipes or on poles etc complete all as specified and as directed Make - Havells/Polycab/Finolex
Supply, laying jointing and testing 25 Sqmm 4 core XLPE insulated LT under ground cable, 1100 volts grade heavy duty, armoured with multi stranded aluminium conductor laid in trenches/ ducts pipes or on poles etc complete all as specified and as directed Make - Havells/Polycab/Finolex
Excavation in trenches in soft/loose soil , not.exc 1.5 mtr wide and not.exc 1.5 mtr deep and getting out in soft/loose soil for laying of cable/foundation of pole and stay etc complete all as sepecified and directed.
Returning filling in, soil including spreading, levelling, watering and well ramming in layers n.exc 25 cm.
Removing surplus excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above ground level from starting point.
M&L for sand cushioning in trenches for protection of LT under ground cable including watering and consolidation complete all as specified and directed. (Note:- punned thickness shall be measured only)
Supply and laying well burnt sub class ‘B’ bricks, locally best available laid in trenches for protection of underground cable complete all as specified and directed.
M & L for boring of holes under road, pavement, hard standing by trenchless boring manually or by machine for insertion of GI pipe of size upto 40 mm dia suitable complete all as specified and directed.
S&F GI pipe 40 mm light grade with all fitting fixed to electric pole and laid in road crossing for cable protection with suitable size clamp, nut bolt and washers all as directed. Make : Tata/Jindal/swastik
Supply only street light bracket, clamps, nuts and bolt with new street light bracket made out of 25 mm dia light grade GI pipe (length of pipe should not be less than 1.2 mtrs) , two set of clamp made out of 25 mm x 3 mm flat iron, nuts & bolts as required , bend to shape and fixing arrangement duly welded complete all as directed.
Supply only Street light fitting with new generation energy saving environemental friendly long life LED street light made up of pressure die cast aluminium housing with lens, energy efficient high quality consistency, glare control with toughned glass and individual high power LEDs with secondary optics ,IP66 protection and impact of capacity 60 Watt complete all as specified and directed by Engineer-in-charge. Make:- Havells/Philips/Syska/Surya Roshani
Supply only flood light fitting with new generation energy saving environement friendly long life exclusive innovative die cast aluminium IP66 LED flood light with high power LEDs as light source of capacity 120 Watt complete all as specified and directed by Engineer-in-charge.Make:- Havells/Philips/Syska/Roshani
Supply only flood light fitting with new generation energy saving environement friendly long life exclusive innovative die cast aluminium IP66 LED flood light with high power LEDs as light source of capacity 50 Watt complete all as specified and directed by Engineer-in-charge.Make:- Havells/Philips/Syska/Roshani
Supply only 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tap and over all PVC sheathed of size 6 Sqmm 2 core complete all as specified and directed. Make :-Palza/Polycab/Havells
Supply only cable junction box with new pole mounted thermoplastic cable junction box for steet light 4.5 module with IP-65 protection, halogen free and weather proof with metric knockouts for cable entry for outdoor installation of approx size 126 mm x 288mm x 111 mm with front door opening system including terminals for one incoming and two outgoing cables of size 16/25 sqmm 4 core, one MCB SP 3 to 6 Amp 240V AC with mounting clamp of flat iron, nut, bolt and washers complete all as specified and directed . Make of junction box - Hensel / Syntex / Havells
M&L for painting of existing LT/HT pole upto 9 / 11 meter height with two coat of aluminium paint complete including preparation of old painted surfaces and including making blue / black colour paint strip of 15 cm width including writing the Pole Nos. complete all as specified and directed.
Supply and fixing in repair MCB 4 pole 100 Amps, 240 Volts 50 HZ, 10 KA breaking capacity, 'C' curve complete all as directed.Make:- Havells/L&T/Legrand/ABB
Supply and fixing in repair Power contactor with new power contactor 3 pole AC, with 415 volt coil, 40 Amp rating complete all as specified and directed. Make- L&T/Havells/Legrand
Supply and fixing in repair astronomical time switch with new astronomical time switch 110-240V 1 C/O - 2 Mod in street light circuit to control the ON/OFF timing of street/parameter complete all as specified and directed by the Engineer-in-Charge. Make- L&T / LEGRAND/Havells
Supply only aviation light fitting with integral LED aviation light comprising of aluminium housing with polycarbonate enclosure capacity 20 Watt complete all as specified and directed by Engineer-in-charge. Make: Philips/Havells/Syska
M&L in XLPE insulated sheathed(heavy duty) armoured aluminium conductor cable of size 6.0 Sqmm, 3 core for connection drawing through pole or GI brackets of street light fittings with junction box complete all as directed. Make : Plaza/Finolex/Havells/Polycab
M&L for heat shrinkable jointing kit of 1.1 KV grade 16 Sqmm to 25 Sqmm x 4 core XLPE cable including suitable size of connector complete all as per directed by Engr-in-charge. including necessary excavation and earth work , labour, Jointing kit complete, fixing charges & T&P including removing of grass/shrubs nearby the fault location all as specified and directed. MAKE:- M-seal, Raychem, CAB Seal, Denson.
Detection of pin point fault in LT cable (burried in ground/under road/path up to depth of 1.5 m) by cable fault locating machine comprising impulse generator,acoustic fault locator and reflectometer (laptop based) complete all as specified and as directed by Engr-in-Charge. Notes-(1) Cable fault locating machine to be arranged at site with in 12 hrs after intimation (2) Earth work will be measured seperatly.(3) Cost of transpotation in unit rate is deemed to be included. Location:-AF stn BKT.
Cutting and trimming of tree branches 2 mtr all around of single pole any size obstructing lumination of street light pole removing trimmed tree branches and bushes.
Petty repair works to internal electrification comprise of checking of nonfunctional existing electric circuits /wiring of light points/fan points/power points/energy meter etc and checking of fan/exhaust fan,switch/sockets ,DBS/MCCBs //MCB/ and other faults by deploying trained electrician with helper from 0900 hrs to 1700 hrs and tools and saftey equipments on daily basis for continuous electric supply and carrying out minor repairs as required to make the items functional or to restore electric supply with and incl tightening of lose and broken connections ,insulating naked wires ,opening of DBs etc and refixing the same after necessary repair.Replacing defective items provided under relevents items here-in-after with and including petty repairs of items/materials i.e. fuses thimbles upto 01 m copper wire of any size screw washer nut bolt etc and cutting of backelite sheet for fixing accessories making all electric connections in Md/OTM Accn and in any location within tech area of GE(AF) BKT every day except sunday and holiday during ofiice time all as specified and diected by Engr-In-Charge. Note :- (a) Spares shall be measured and paid seperately as 'Supply only' and fixing rate included in quoted rate. (b) In case of functional requirement ,contractor is required to extend th service on sunday and public holidays as notified by Engr-In-Charge. (c) If tradesmen found absent recovery will be made @ double the quote rate for this items
Supply only in repair switch piano flush type 6 Amp. AC, 240 Volts one way all as directed. Make :- Anchor / Havells/ Legrand
Supply only in repair socket 6 Amp. AC, 240 Volts one way all as directed. Make :- Anchor / Havells/ Legrand
Supply only bell push flush type single pole one way, 5 Amp, AC,230 V all as directed with frame cover Make :- Anchor / Havells/ Legrand
Supply only switch socket combination. Multi purpose 6 Pin 6 Amp flush type AC, 230V complete all as directed.Make :- Anchor / Havells/ Legrand
Supply only switch socket combination. Multi purpose 6 Pin 16 Amp flush type , AC, 230V complete all as directed.Make :- Anchor / Havells/ Legrand
Supply only angle holder backelite with insulated body AC, 230V complete all as directed.Make :- Anchor / Havells/ Legrand
Supply only call bell electric AC, 230V, Single phase, Dingdong type complete all as directed.Make :- Anchor / Havells/ Legrand
Supply only Modular switch 1 way 6A 1 module type all as directed.Make :- Anchor / Havells/ Legrand
Supply only Modular switch 1 way 16A 1 module type all as directed.Make :- Anchor / Havells/ Legrand
Supply only Modular Socket 6A/16A - 2/3 pin combined 2 module all as directed.Make :- Anchor / Havells/ Legrand
Supply only Sleek LED mirror light 10 watt rating with diffuser 2ft long twisted flexible copper wire (approx 0.5 mtr long) complete all as specified & approved by EIC. Make :- Havells/Philips/ GE
Supply only decorative surface mounting LED dwonlighting with white diffuser 07 watt luminaire for 230 volt AC complete all as specified & approved by EIC.Make :- Havells/Philips/ GE/crompton
Supply only decorative surface mounting LED dwonlighting with white diffuser 12 watt luminaire for 230 volt AC complete all as specified & approved by EIC.Make :- Havells/Philips/ GE/crompton
Supply only LED Driver of capacity 12 VDC/1000mA suitable for 36 watt LED light fittings, complete all as specified & approved by EIC. Make :- Havells/Philips/ GE
Supply only square recessed / surface/suspended mounting LED slim ceiling light with extruded aluminium housing and milky diffuser of 36 W 2'X 2' slim panel LED driver 240 V ,50 Hz complete all as specified & approved by EIC. Make :- Havells/Philips/ GE
Supply only LED tube RETRO LED 16 to 22 watt of size 4 ft long complete all as specified & approved by EIC.Make :- Havells/Philips/ GE
Supply only MCB Four Pole 40 to 63 Amps 415 Volts, 50 Hz, 10 KA breaking capacity complete all as directed. Make :- Havells / Legrand / GE / Seimens
Supply only temper proof energy meter (Kwh meter) with LCD display , single phase 240 volts AC 50Hz 10-60 amps capacity with optical communication port base mounted with 3Nos NIC Seal push type and including temper proof polycarbonate transfarent box hinge type with 02Nos NIC Seal push type complete all as specifiedits connection with PVC insulated unsheathed stranded copper conductor 6 sqmm single core cable with lugs including suitable size of PVC flexible pipe complete all as specified and directed.Make L&T/Secure,
Supply only temper proof energy meter (Kwh meter) with LCD display , three phase 415 volts AC 50Hz 10-60 amps capacity with optical communication port base mounted with 3Nos NIC Seal push type and including temper proof polycarbonate transfarent box hinge type with 02Nos NIC Seal push type complete all as specifiedits connection with PVC insulated unsheathed stranded copper conductor 10 sqmm single core cable with lugs including suitable size of PVC flexible pipe complete all as specified and directed.Make L&T/Secure,
Supply only capacitor 2.5 mfd complete all as specified and approved by EIC. Make- EPCOS/Havells/M-CAP .
Supply only Fan down rod made out of GI pipe (light grade) 15mm bore and 1.20 meter long including rubber real and suitable nuts and bolts,safty pin complete all as specified and directed.
Supply only exhaust fan louvers made out of mild steel suitable for exhaust fan of size 300mm sweep including taking down old complete all as specified and approved by EIC.
Supply only plug top 3, pin 15 Amp complete all as specified & directed.
Supply only stepped fan regulator flush type two module, 100 watt, AC, 230V, Single phase, complete all as directed.
Supply only stepped fan regulator (single module) flush type , 100 watt, AC, 230V, Single phase, complete all as directed.
Suplly only modular type electronics fan regulator (single module), 100 watt, AC, 230V, Single phase, complete all as directed.
Supply only plug top 3, pin 5 Amp complete all as specified & directed.
Supply only fan blade set suitable for 1200 mm sweep fan with accessories complete all as specified & directed.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated copper conductor, served with inner sheathing of PVC tape and overall PVC sheathed flexible two core cable flat or circular of size 1.5 Sqmm multi stranded copper conductor all as specifiied and directed.Make :- Havells/ Plaza/Finolex/Polycab.
Taking down caefully switch board complete with MS rectangular type box heavy duty from the existing position and supply & fix with suitable size of 1 to 12 module metal flush boxes and including modular front cover plate & back plate for mounting modular type switches /socket/fan/ regulator etc with making good the disturbed surface of wall with colour washing /distempering the surface to match the existing one all as specfied and directed
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including fitting and fixture and such as as switches, sockets ceiling rose,pendent holders,regulators,light fittings any type removing materials to store in safe custody or for credite etc, and making good the disturbed surface of walls and floors etc as directed.
M&L for point wiring with two single core PVC insulated unsheathed stranded FRLS copper conductor cable of size 1.5 Sqmm 1100 volts grade in existing conduit with all accessories and one single core PVC insulated unsheathed stranded copper cable of size 1.5 Sqmm 1100 Volts grade as earth continuity conductor connected to common earth dolly, switch board complete with PVC rectangular type box heavy duty for mounting the switch socket etc complete as specified for the following :-(a) One light/Fan / Exhaust point controlled by one 5 Amps switch one way complete
All as per item no 59 but one bell point controlled by one 5 Amp bell push complete
All as per item no 59 but One 5 Amp socket point controlled by one 5 Amp switch independent board with cable 1.5 sqmm.
All as per item no 61 but on the same board.
All as per item No 59 herein before but using 2.5 sqmm, PVC insulated, stranded copper conductor single core cable for one 3 pin 15 Amp socket out let point on an independent board Make of Cable :- Havells/ Plaza/Finolex/Polycab.
M & L for point wiring with two single core PVC insulated & PVC unsheathed FRLS multistranded copper conductor cable of size 1.5 sqmm 1100 volt grade in and including making good the disturbed surface of wall with colour washing /distempering the surface to match the existing one in non metallic rigid PVC conduit medium grade 2 mm thick medium 20/25 mm dia with all accessories mounting all the surface of wall/ceiling/roof/etc with suitable size of 1 to 12 module metal flush boxes and including modular front cover plate & back plate for mounting modular type switches /socket/fan/ regulator etc including provision of one single core PVC insulated and unsheathed multi stranded copper cable of size 1.5 sqmm 1100 volt grade as earth continuty conductor connected to common earth dolly switch board complete all as specified and directed. Note:- surface Conduit shall be laid in celing portion only. Make: Plaza/havells/polycab
All as per item no 64 but one bell point controlled by one 5 Amp bell push complete
All as per item no 64 but point wiring for One 5 Amp socket point controlled by one 5 Amp switch on same board with cable 1.5 sqmm.
All as per item No 64 but point wiring for One 5 Amp socket point controlled by one 5 Amp switch independent board with cable 1.5 sqmm.
All as per item No.64 here-in-before but with two single core PVC insulated & PVC unsheathed multi stranded FRLS-H copper conductor cable of size 2.5 Sqmm 1100 volts grade and one single core PVC insulated &PVC sheathed multi stranded copper conductor cable of size 2.5 Sqmm 1100 Volts grade as earth continuity conductor including PVC surface / concealed conduict of size 20 to 25 mm with all accessories for 3 pin 15 Amps socket point on independent board complete all as specified and as directed. Make of Cable :- Havells/ Plaza/Finolex/Polycab. Make of PVC conduit :- AKG/ Plaza/ Jindal / Finolex
S&F switch piano flush type 6 Amp. AC, 240 Volts one way all as directed. Make :- Anchor / Havells/ Legrand
S&F switch piano flush type 15 Amp. AC, 240 Volts one way all as directed. Make :- Anchor / Havells/ Legrand
S&F socket outlet flush type 2 in one 3 pin 5 Amp, AC, 230 volts , complete all as directed.Make :- Anchor / Havells/ Legrand
S&F socket outlet flush type 2 in one 3 pin 15 Amp, AC, 230 volts, complete all as directed.Make :- Anchor / Havells/ Legrand
S&F bell push flush type single pole one way, 5 Amp, AC,230 V all as directed with frame cover Make :- Anchor / Havells/ Legrand
Supply & Fix switch socket combination. Multi purpose gang box type 6 Pin 6 Amp flush type , AC, 230V complete all as directed.Make :- Anchor / Havells/ Legrand
Supply & Fix switch socket combination. Multi purpose gang box type 6 Pin 16 Amp flush type , AC, 230V complete all as directed.Make :- Anchor / Havells/ Legrand
S&F modular switch single pole, one way 5 Amps.Make:Plaza/Anchor/Legrand/Havells
S&F modular switch bell push single pole one way 5 amp 230 volrt 6 amp 1 module comlete
S&F modular socket 6/16 amp 2/3 pin combined 2 module complete Make:Plaza/Fine/Anchor
S&F modular switch socket combination 6/16 amp 2/3 pin combined 3 module type complete Make:Plaza/Fine/Anchor
S&F ceiling Rose, surface, bakelite 65 x50 mm three terminals, AC, 230 Volts complete all as directed.Make :- Anchor / Havells/ Legrand
S&F angle holder backelite with insulated body AC, 230V complete all as directed.Make :- Anchor / Havells/ Legrand
S&F bell electric AC, 230V, Single phase, Dingdong type complete all as directed.Make :- Anchor / Havells/ Legrand
S&F in repair decorative box type fitting for LED tube 16 to 22 watt luminaire for 230 volt AC,for LED tube 16 watt to 22 watt complete all as specified & approved by EIC.Make :- Havells/Philips/ GE/crompton
M&L in repair for submain wiring with two run of single core PVC insulated unsheathed multi stranded FRLS-H copper conductor cable of size 4 Sqmm 1100 volts grade and one run of PVC insulated unsheathed multi stranded copper conductor cable of size 4 Sqmm 1100 volts grade as earth continuity conductor drawn through in and including rigid non metallic PVC concealed / surface conduit of suitable size on roof/wall/ceiling including making good the disturbed surfaces of wall etc including taking out old unserviceable burnt/damaged sub main wiring from its existing position complete all as directed by Engr-in-Charge (Note : Two run of single core cable and one run of earth wire will be measured as one length and conduit and its accessories is deemed to be included in the unit rate). Make of Cable :- Havells/ Plaza/Finolex/Polycab. Make of PVC conduit :- AKG/ Plaza/ Jindal / Finolex
M&L in repair for submain wiring with two run of single core PVC insulated unsheathed multi stranded FRLS-H copper conductor cable of size 6 Sqmm 1100 volts grade and one run of PVC insulated unsheathed multi standed copper conductor cable of size 6 Sqmm 1100 volts grade as earth continuity conductor drawn through in and including rigid non metallic PVC concealed / surface conduit of suitable size on roof/wall/ceiling including making good the disturbed surfaces of wall etc including taking out old unserviceable burnt/damaged sub main wiring from its existing position complete all as directed by Engr-in-Charge (Note : Two run of single core cable and one run of earth wire will be measured as one length and conduit and its accessories is deemed to be included in the unit rate). Make of Cable :- Havells/ Plaza/Finolex/Polycab. Make of PVC conduit :- AKG/ Plaza/ Jindal / Finolex
M&L in repair for Submain wiring with 4 run of single core PVC insulated FRLS multistrand copper conductor cable of size 10 Sq mm drawn into and including non metallic heavy duty rigid PVC conduit not less than 25 mm size ISI marked ivory colour (Pressfit or similar brand ) with all conduit fittings / accessories and 2 run single core 10 Sq mm FRLS multistrand copper conductor cable as continuous earth wire complete. (Note for submain wiring: 4 run of single core cable and run of earth wire will be measured as one length). Make of Cable :- Havells/ Plaza/Finolex/Polycab. Make of PVC conduit :- AKG/ Plaza/ Jindal / Finolex
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed flexible two core cable flat or circular of size 2.5 Sqmm solid aluminium conductor all as specifiied and directed.Make :- Havells/ Plaza/Finolex/Polycab.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed flexible two core cable flat or circular of size 4 Sqmm solid aluminium conductor all as specifiied and directed.Make of Cable :- Havells/ Plaza/Finolex/Polycab.
Taking down old unserviceable main switches/DB’s up to 100 Amps capacity fixed in wall and making good of all disturbed surfaces as per existing .
S&F sheet metal enclosure for DB’s when MCB to be used single pole and neutral double door, 4 way, AC,240 volt with 200 Amp bus bar rating complete all as directed. Make :- Havells / Legrand / GE / Seimens
S&F sheet metal enclosure for DB’s when MCB to be used single pole and neutral double door, 8 way, AC,240 volt with 200 amp bus bar rating complete all as directed.Make :- Havells / Legrand / GE / Seimens
S&F sheet metal enclosure for DB’s when MCB to be used single pole and neutral double door, 12 way, AC,240 volt with 200 Amp bus bar rating complete all as directed.Make :- Havells / Legrand / GE / Seimens
S&F sheet metal enclosure double door (MCB DB) three phase and neutral with 200 Amps rated bus bar TPN, 4 way verticall type, with provision of MCB incommer, AC, 415 Volt complete all as specified & directed.Make :- Havells / Legrand / GE / Seimens
S&F sheet metal enclosure double door (MCCB DB) three phase and neutral with 200 Amps rated bus bar VTPN, 4 way vertical type, with provision of MCCB incommer, AC, 415 Volt complete all as specified & directed.Make :- Havells / Legrand / GE / Seimens
M & L industrial socket 5 pin, 3P+E 240V, AC of rating 32 Amps with industrial plug top complete with triple pole MCB and all fixing accessories all as specified & directed. Make :- Havells/L&T/ Legrand
M & L industrial socket 3 pin, 2P+E 240V, AC of rating 20 Amps with industrial plug top complete with double pole MCB and all fixing accessories all as specified & directed. Make :- Havells/L&T/ Legrand
S&F MCB single pole, 6 to 32 Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as directed.Make :- Havells / Legrand / GE / Seimens
S&F MCB single pole, 32 to 40 Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as directed.Make :- Havells / Legrand / GE / Seimens
S&F MCB DP 40 to 63 Amps 240 Volts, 50 Hz, 10 KA breaking capacity complete all as directed.Make :- Havells / Legrand / GE / Seimens
S&F MCB Four Pole 40 to 63 Amps 415 Volts, 50 Hz, 10 KA breaking capacity complete all as directed.Make :- Havells / Legrand / GE / Seimens
S&F MCB Four Pole 100 Amps 415 Volts, 50 Hz, 10 KA breaking capacity complete all as directed.Make :- Havells / Legrand / GE / Seimens
S&F MCCB 4 pole 100 / 125 Amp 415 volts 50 HZ 25 KA breaking capacity complete all as directed.Make :- Havells / Legrand / GE / Seimens
M&L for painting of ceiling fan, exhaust fan,with synthetic enamelled paint by spray painting machine including filling cavities with filler one coat after cleaning all dust etc including writing of MES No including taking down and refixing complete all as specified and directed.
M&L for rewinding of ceiling fan of size 1200 mm sweep with super enamelled copper winding wire of existing gauge, reassembling the same complete including taking down cleaning and replacement of split pin rubber reel, clamp, check nuts, flexible cord of size 3 core of suitable size including leathe work of shaft complete and refixing the same after repair all as directed
M&L for rewinding of wall mounted fan of size upto 400/450 mm sweep with super enamelled copper winding wire of appropriate guage for any make or model including replacement of minor parts such as shaft bush condenser of wall mounted fan and reassembling, taking down cleaning testing and refixing the same after repair complete all as specified and approved by EIC.
M&L for rewinding of wall mounted fan of size upto 600 mm sweep with super enamelled copper winding wire of appropriate guage for any make or model including replacement of minor parts such as shaft busg condenser of wall mounted fan and reassembling, taking down cleaning testing and refixing the same after repair complete all as specified and approved by EIC.
M&L for rewinding of exhaust fan of size upto 300/350 mm sweep with super enamelled copper winding wire of appropriate gauge for any make or model,reassembling and testing including taking down cleaning and replacement of split pin rubber reel, clamp, check nuts, flexible cord of size 3 core of suitable size complete and refixing the same after repair all as directed
M&L for rewinding of exhaust fan of size upto 450 mm sweep with super enamelled copper winding wire of appropriate gauge for any make or model,reassembling and testing including taking down cleaning and replacement of split pin rubber reel, clamp, check nuts, flexible cord of size 3 core of suitable size complete and refixing the same after repair all as directed
M&L for rewinding of pedstal fan of size upto 600mm sweep with super enamelled copper winding wire of appropriate gauge for any make or model,reassembling and testing complete all as specified and approved by EIC.
Supply & replacement ball bearing No 6201/6202 for ceiling fan/exhaust fan including taking out old & UNSV complete all as specified and approved by EIC. Make- SKF/NBC/Tata.
Supply & replacement of Gun metal bush for ceiling fan/Pedestal an/Air circulator/wall fan etc including dismantling complete all as specified and approved by EIC.
Supply and fixing ceiling fan complete with blade down rod and accessories 230 V,1200 mm sweep air delivery 210 cfm complete five star rated with brusheless direct current motors all s specified and directed
Supply and fixing ceiling fan complete with blade down rod and accessories 230 V,1400 mm sweep air delivery 245 cfm complete five star rated with brusheless direct current motors all s specified and directed
Supplying, Installation and testing of isolation transformer 2 KVA ,240 Volts AC ,50 Hz 1:1 ratio of input and output voltage copper wound air cooled with MS sheet metal enclosure duly painted with 3 core copper conductor PVC insulated cable with plug top to maintain E_N voltage less than 2 volts Makr blue bird/Sai electricals/Volino
M& L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cmx6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 5 of MES Schedule Part-I including and connecting to earthing test point block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw and testing on completion with and including 15 mm bore light grade G.I. protection pipe (upto 7.5 M beyond outer edge of earth pit) PCC pit in mix 1:3:6 type C1 with RCC 1:2:4 type B-1 40 mm thick cover reinforced with 6 mm dia M.S bars 3 Nos both ways with lifting hook made out of 6 mm dia bar, watering arrangement with funnel and wire mesh and 40 mm bore light grade G.I. watering pipe, common salt and charcoal filling, necessary excavation and earth work including Earthing pit marker/ identifier of Iron plate of size 300mm X 200mm X 3mm and alongwith 1 meter long medium grade GI pipe of size 15 mm dia weilded with steel plate including painting with applying one coat of red oxide and two coat of painting with synthetic enameled paint of approved quality including writing letters as specified ny EIC complete including testing on completion complete all as specified and directed.Colour coding on indicator plate will be done as per VCAS directive of Air force.
Industrial Traders
HINDUSTAN TRADING COMPANY
H C CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .