Loading…
Loading…
Tender Value
₹4.3 Cr
EMD Value
₹8.6 L
Closing Date
9 Jul 2026, 3:30 pm
Similar tender results from the same govt authority in the past 3 years.
Provision of CCTV surveillance system at Relay Huts, Relay Room & SM Room for EI and IBS station over Lucknow Division, Northern Railway
106-Tele_Tender_08_26-27
106-Tele_Tender_08_26-27
Open
270 Days
Lucknow, Uttar Pradesh
₹0
₹8.6 L
18 Jun 2026
18 Jun 2026
25 Jun 2026
"Supply, Installation, Testing and Commissioning of Full HD Fixed Bullet type IP Color 01 Camera along with128 GB or Higher SD Card, housing and mount and all accessories required for installation purposes per RDSO Spec No. RDSO/SPN/TC/65/2021,Rev6.0 or latest. INSPECTION: RDSO FOR SUPPLY PORTION"
Supply, installation, testing, wiring &commissioning of Video Management & 02 Recording software with license as perRDSO Specification NoRDSO/SPN/TC/65/2021 Version 6.0 orlatest amendment. (Per camera licensemeans video management (Viewing) atmultiple locations such as station, RPFpost & server room by same license).INSPECTION: RDSO FOR SUPPLY PORTION
"Supply, installation, testing, wiring &commissioning of Video Analytic software with 03 license as per RDSOSpecification No RDSO/SPN/TC/65/2021 Version 6.0 or latest amendment. (Per camera licensemeans video management (Viewing) atmultiple locations such as station, RPFpost & server room by same license). INSPECTION: RDSO FOR SUPPLY PORTION"
Supply of 32- channel NVR as per specs No. 10.2 of RDSO Specs No. RDSO/SPN/TC/65/2021 Version:6 or latest including 1 TB Surveillance HDD. INSPECTION: RITES FOR SUPPLY PORTION
"Supply and installation of 8TB Hard Disk Drive Internal for CCTV for NVR (WD) (WD Surveillance purple) with 3 year Warranty INSPECTION: CONSIGNEE FOR SUPPLY PORTION"
"Supply, Installation, Testing & Commissioning of Professional Large Format LED Video Display Unit, 55"" (inches) or larger, Full HD 1920 x 1080, Brightness: 350cd/m, contrast ratio 06 1100:1, HDMI & DVI port, Including wall mount kit. as per clause no. 9.0 of RDSO/SPN/TC/65/2021 Rev. 6.0 or latest. Material should be procured from RDSO approved vender or OEM Supporting certificate shall be provided that the material has been manufactured as per RDSO specification. INSPECTION: RDSO FOR SUPPLY PORTION"
"Supply of layer-2 switch ( minimum 8 +2 manageable ) with 08 Nos. 10/100/1000 07 Mbps ethernet port POE and 02 nos.1000 baseX SM SFT port with optical modules complete with all accessories etc. as per RDSO specification no. RDSO/SPN/TC/65/2021 version-6 or latest INSPECTION: RDSO"
Installation, Testing & Commissioning of Layer-2 PoE Switch (minimum 8+2 port 08 manageable) with 8 nos. 10/100 /1000 Mbps Ethernet port and 2 nos. 1000 Base X SM SFP port with optical modules complete. All the accessories and fixing materials required for this installation are to be supplied by contractor within the same cost.
"Supply of 12 Fiber Armored Single mode Optical Fiber ITU - G 652 D. All Dielectric Self Supporting Optical Fiber Cable as per GEM Specification Enclosed. Make: FINOLEX, KEC or Better INSPECTION: RITES FOR SUPPLY PORTION"
"Supply of STP CAT-6 Cable (Shielded Twisted Pair) STP compliant with latestEIA/TIA- 568-B2-1. INSPECTION: RITES"
"Supply and installation of 9U, 19 inch rack for pole mount/ wall mount with Fan 230VAC 90CFM-02 Nos., AC distribution box (5 socket of 5A, Power On LED indicator, MCB)- 01 No., Shelf Cantilever 1U: 01 No. Cable Manager 1U:01 No. INSPECTION: RITES FOR SUPPLY PORTION"
"Supply of 12 port loaded LIU rack mountable, LIU shouldbe provided for terminating the optical fiber cables. It shall provide minimum bending radius and splice trays shall function as a 12 splice cover for Pigtail Splicing. Cable glands shall be provided for secure anchoring of incoming cables. Rubber grommets shall be provided at the cable entry point for tight sealing. The splice tray should be made of ABS materials. LIU should be of reputed make. Make: D-Link/3M/ Digilink/Molex/ DAX or similar. INSPECTION: RITES"
Installation, Testing & Commissioning of rack mountable 12 port Loaded LIU. All the accessories and fixing materials required for this installation are to be supplied by contractor within the same cost.
"Supplying and fixing 8way, sheet steel, Double Door MCB distribution board ,240V, on surface/recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, 14 interconnections, powder painted including earthing etc. a) DP MCB 32 A,10KA ""C"" curve(incoming)-1 No, b) 25A DP RCCB = 01 No. having a sensitivity current 30 ma c) 06A,10 KA MCB SP ""C""curve = 03 Nos. & 10A,10 KA MCB SP ""C""curve = 01 Nos.(Outgoing) Or as per instruction of Railway, Make of MCB/MCCB: SchneiderElectric, ABB, GE,Siemens, L&T, Legrand,Hager or similar. INSPECTION: CONSIGNEE FOR SUPPLY PORTION"
"Supply of 2 KVA ONLINE UPS WITH TWO HOUR BACKUP ,HAVING SMF BATTERY 4680 TO BE OPERATED IN INPUT VOLTAGE OF 160-260V 50 Hz AC,INPUT OVER VOLTAGE PROTECTION 280 15 VAC ,INPUT UNDER VOLTAGE PROTECTION 155 V AC,WITH MANUAL BY PASS PROVISION,OVER LOAD CAPACITY OF 125 % OF RATED LOAD UNDER TEST FOR 60 SEC. WARRANY OF 2 YEARS FOR UPS AND BATTERY, INDIACTIONS SHALL BE MAINS ON ,BATTERY CHARGER ON ,BATTERY ON LOAD ,BATTERY LOW, INVERTER ON ,INVERTER TRIP,OVER LOAD ,DC -ON MINIMUM VAH 4680 PREFFERRABLE MAKE :HYKON HITACHI,NUMERIC,TECHSER,AMARAJS,V GUARD INSPECTION: RITES FOR SUPPLY PORTION"
"Supply of Online UPS of Rating 1.0 KVA With Battery Of Backup Time 60 Minutes Brand: Uniline/APC/NUMAX or better INSPECTION: RITES FOR SUPPLY PORTION"
"Supply of power cable 3 core, 2.5 sq mm, multi strand (36/0.3 mm dia) cable as per IS 694:1990 reaffirmed 1995 or latest suitable for Railway electrification area, shall be of reputed make like Havells, Delton, LAPP, Finolex, or superior. INSPECTION: RITES"
"Supply of PVC conduit pipe (minimum 25 mm dia./1.55 mm thick, 3 metre long and ISI brand) with flexible pipes fixing /laying materials and all other accessories as per requirement. INSPECTION: CONSIGNEE"
"Chase cutting in floor / wall and restoring of floor / wall with plaster for concealing of 50 mm./25mm conduit pipe in floor/wall (pipe shall be supply by railway). As per instructions by Consignee."
Pulling and Blowing/drawing of OFC cables inthe HDPE duct along with all theprotective work as per instructionsof engineer incharge at site.
"Supply of Pre-lubricated HDPE duct, 40 mm OD, 33 ID as per RDSO specification No. RDSO/SPN/TC/45/2013 Rev. 2.0 or latest. The item also includes supply of all the accessories of HDPE duct like end caps, collars, bends, couplers etc. INSPECTION: RITES"
Laying of PLB HDPE pipe in trench/open space, fixing and clamping of HDPE pipe on 22 wall or structure and sealing of the duct after laying with proper fixing material. All the accessories like couplers, end caps/plugs to be provided by the contractor within the same cost and its protective work as per direction of site engineer.
Laying of OFC/Power cable/CAT-6 cable PA Cable/Data cable and all the other types of telecom cable and all the other types of telecom cable through HDPE pipe/casing capping/fall ceiling 23 with laying/fixing of HDPE pipe/casing capping/uPVC pipe for connecting/interfacing variouys cpmponents and system integration. All materials for jointing and termnaition of power cable/CAT-6 cable as per site requirement are to be supplied by contractor. This item also includes supply of RJ- 45 connector with cap for terminating CAT-6 cable and supply and installation of power board with 4 points (3 nos 5 amp sockets and 1 nos 15 Amps socket) as per site requirement.
"Supply, Installation & commissioning of Maintenance free earth using basic earthing kit as per RDSO specification RDSO/SPN/197/2008 or latest and Drg No. SDO/RDSO/E&B /001 & 002 dated 19.9.2008 or latest. Earthing kit consist of 1. Earthing electrode of 17mm dia and 3 meter long-01 no. 2. MEEB (300mm X 25mm X 6MM) -01 no. 3. SEEB (150mm X 25mm X 6 mm) - 01 no. 4. Earth enhancing compound - 30 Kg (minimum). This include provision of earth connection from MEEB to S&T equipment i.e. cable sheath, apparatus case, IPS, data logger, signal etc. with PVC earth wire of size 16/25 Sq.mm through copper lugs of suitable size. PVC wire shall be supplied by Railways. 24 Note: At certain locations it may not be possible to achieve earth resistance of less than 1.0 ohm with one earth electrode/pit due to soil resistivity. In such case provision of loop earth consisting of more than one earth pit shall be done. For interconnection of two earth pits copper tape of size 25X2 sq. mm shall be provided by contractor. The number of pits required shall be decided based upon the resistance achieved for the earth pit already installed. The procedure mentioned above for one earth pit shall be repeated for other earth pits. The other earth so installed for the purpose of loop earthing arrangement shall be counted as separate earth. Material to be procured through RDSO approved firm. Contractor have to submit check list duly signed by OEM after installation. INSPECTION: RDSO FOR SUPPLY PORTION"
"Supply of STP/UTP RJ 45 Connectors Make D-Link, AMP, DAX, Legrand, Molex or Digilink. INSPECTION: CONSIGNEE"
Horizontal direction drilling(HDD)/Trenchlessdigging/machine drilling withoutdamage to surface road /trackfor laying/insertion ofHDPE/GI/DWC pipe. The boreshall be done at the depth ofminimum 1400 mm from theground level. The ground levelshall be considered ignoring thebank 26 height of the bank of the road. Note:- DWC/HDPE/GI PipeSupply is not covered under thisitem. Contactor shall provide allmaterial required for work andadequate nos. of labours forproper laying of cables into thebore. Cable shall be laidcautiously so that it should notget damage due to roughhandling & pressure on cable.Payment of boring shall bemade only aft er DWC/HDPE/GIpipe is laid in the bore."
"Supply of HDMI cable of 15 mt of reputed brand. INSPECTION: CONSIGNEE"
Excavating and refilling of trench in Normal Soil to the level of ground with rammed 28 earth as per drg. No. NR/S&T/Con./1.1/97A or latest so as not to form a drain 0.3 mtrs. Wide & 1 mtr. Deep on both side of the station alongside the track. It shall conform to the safe distance as per signalling and cable plan in all type of soil. It also includes clearance of roots of trees & bushes. (15cm wide 30cm depth)
"Supply & Installation of 19"" Rack 17U withpower strip and all fitting accesssories forhousing of network equipment. Both side door INSPECTION: RITES FOR SUPPLY PORTION"
"Supply of workstation suitable for fault analysis or other application. Note:- 30 Workstation configuration are as follows: Intel Core i5 10500 or higher, 16 GB RAM, HDD 1000 GB, SSD 512 GB Windows 10/11, 2K display 21.5 Inch or better. It also includes supply of Laser duplex Printer (Make HP/Brother or better). INSPECTION: RITES FOR SUPPLY PORTION"
"Supply of Server Hardware for VideoManagement and recording along withall accessories as per RDSOSpecification No RDSO/SPN/TC/65/2021Version 6.0 or latest. INSPECTION:RDSO"
Installation, Testing & Commissioning ofServer for Video Management andrecording along with all accessoriesasper RDSO Specification NoRDSO/SPN/TC/65/2021 Version 6.0 orlatest.
"Supply of ServerHardware for VideoAnalytics and all otherrequired accessories tomake the systemoperational, as perRDSO SpecificationRDSO/SPN/TC/65/2021Ver. 6.0. or latest. INSPECTION: RDSO"
"Supply of rack mountable (4+24) port manageable layer-3 core switch with 4 nos. 10G SFP+ ports and 24 Nos GE ports with all accessories as per RDSO specification no. RDSO/SPN/TC/65/2021 version-6 or latest INSPECTION: CONSIGNEE"
"Installation, Testing & Commissioning of rack mountable ( 4+24) port manageable Layer -3 Core switch with 4 nos. 10G SFP port+ and 24 nos GE port. All the accessories and fixing materials required for this installation are to be supplied by contractor within the same cost."
"Supply, Installation, Testing &Commissioning of Aggregate Switch (24x GE SFP ports and 4x10G SFP+) asper RDSO Specification NoRDSO/SPN/TC/65/2021 Version 6.0 orlatest. INSPECTION: CONSIGNEE FOR SUPPLY PORTION"
"Supply, installation, testing, wiring & commissioning of Layer-2 managed Switch (24 38 ports 10/100/1000 BASE-Tports, 4x 1G SFP+ ports) as per RDSO Specification No RDSO/SPN/TC/65/2021 Version 6.0 orlatest make HP/Cisco/Juniper or other reputed make with similar or better specs. INSPECTION: CONSIGNEE FOR SUPPLY PORTION"
"Supply of SFP-s with specification as follows - Data Rate 10 GBPS, TX/Rx wave length - 1310/1550 nm, Supports upto 20 Km distance, Media Type - Single Mode fiber [SMF], Compatibility - Multi-vendor MSA Compatible. INSPECTION: CONSIGNEE"
"Supply of SFP Optical/Electrical 1 Gbps or100/1000 Mbps Electrical as required. Make:Cisco, Eoptical or similar suitable for Neon. INSPECTION: CONSIGNEE"
Installation, testing & commissioning of Single mode1G SFP module compatible to Layer 2 switch.
"Supply of OFC patch cord cable (10m long with APC/FC/LC-LC/FC/APC connector Patchcord) or as per site requirement. INSPECTION: CONSIGNEE"
"Supply of LC/PC-LC/PC patch cord (5 meter) (3M, TE connectivity, R&M make or superior) or as per site requirement. INSPECTION: CONSIGNEE"
"Supply of Single Mode Patch Cord length 3 meters (LC-SC/SC-SC/LC-LC/FC-LC) as per site requirement. INSPECTION: CONSIGNEE"
"Power Board (3 No's 5 amp & 1 no 15 Amp socket total-4 points). Make: Anchor, Havells or similar. INSPECTION: CONSIGNEE"
"Supply of Self supported aluminium step ladder (conforming of ISI) 10 ft. Height (Telescopic) INSPECTION: CONSIGNEE"
"Tools Kit for maintenance with small sizecanvas bag with following items :- 1)Combination Plier 8"", 2) Long Nose Plier(Round Nose ) 6"" , 3) Wire Striper Plier6"" , 4) Screw Driver set ( 5 Piece) , 5) Hexa with frame 12"" 6)Adjustable Spanner set 8"" 7) Ball pinHammer (200 gm) , 8) Side Cutting Plier6"" 10) Soldring iron (Soldron make orsimilar) 11) Torch with cell (3 cell) (Eveready/ Geep or similar ), 12) KroneTool (Krone make or similar) 13) Crimping Tool, 14) LAN Tester, 15) Wrapping and DeWrapping tool, 16) Visual Fault Locator, All ToolItem 1 to 9 of Taparia/Gedor/ Jhalanimake or similar. INSPECTION: CONSIGNEE"
"Supply ofIndiana/phoenix/Jiwei makeperforated cable trays with ourstandard 48 perforation fabricatedfrom 1.6 mm thick pre-galvanized sheet in thestandard length of 2.5 mtrs,with coupler. Plate +electrogalvanized hardware.Size: 300mm width X 50 mmheight. INSPECTION: CONSIGNEE"
Fixing of tray for housing of alltype of telecom cable.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCACS11.pdf
ATTACHMENT
T-0826-27.pdf
ATTACHMENT
ACSGCC22-231to6.pdf
ATTACHMENT
GCC Correction slip 7 to 10
ATTACHMENT
GCC_April-2022_1.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipno7-10.pdf
ATTACHMENT
Download all tender documents and submit your bid