| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-01₹9.8 LAccepted-AOC | L-01 | Accepted-AOC Being lowest bidder | |
| 2 | L-02₹10.1 L+₹17,630 (1.78%)Rejected-Finance | L-02 | Rejected-Finance Being second lowest bidder | |
| 3 | L-03₹10.1 L+₹20,800 (2.10%)Rejected-Finance OPPOSITE GHOOM DRC PO GHOOM DISTT DARJEELING WB PIN 734 102 | DARJEELING | WEST BENGAL | 734102 | L-03 | Rejected-Finance Being third lowest bidder | |
| 4 | L-04₹10.2 L+₹30,180 (3.04%)Rejected-Finance | L-04 | Rejected-Finance Being fourth lowest bidder |
Tender Value
₹9.6 L
EMD Value
₹19,200
Closing Date
23 Jul 2020, 6:00 pmClosed
AGE (I) Darjeeling
AGE (I) Darjeeling Post-Jalapahar Distt-Darjeeling (WB)
REPAIR REPLACEMENT OF EXISTING FLUORECENT LIGHT FITTINGS WITH ENERGY SAVING LED LIGHT FITTINGS AT JALAPAHAR UNDER AGE I DARJEELING
2020_MES_343009_2
8741/E8
Open Tender
Civil Works
Item Rate
182 days
Darjeeling
Please refer tender documents
6 documents required · 6 mandatory
₹500
Yes
AGE (I) Darjeeling
₹19,200
Yes
7 Aug 2020
29 Jun 2020
25 Jul 2020
29 Jun 2020
23 Jul 2020
10 Jul 2020
29 Jun 2020 - 6 Jul 2020
Amount
Taking down carefully existing old unserviceable Copper/Aluminium Point Wiring (Light, Fan, Socket or Power) of any description on batten/conduit (Serviceable Fittings such as Switches, Ceiling Roses, Pendants, Fan Regulators, Sockets, Light Fitting, etc. to be kept in safe custody for reuse) and making good disturbed surfaces of Ceiling, Walls, etc. with Cement Morter 1:3 and treating the surfaces so as to match the existing Finishes complete all as specified and as directed.
Taking out/down burnt/unserviceable Main Switches, Cut out, DB's, Bus-bars Chambers including all Fittings & Fixtures, etc. from existing Main Board and making good disturbed surfaces of Walls, Ceiling, etc. so as to match the existing Finishes, complete all as specified and as directed. NOTE : Quoted Unit Rate against DB's will deemed to be included for taking out/ down of MCB SP/SPN/ TPN.
Taking down old unserviceable/burnt Submain Wiring with copper /aluminum conductor PVC insulated cable of any size drawn through PVC Casing Caping/Conduit including GI Wire Accessories etc. and making good disturbed surfaces of Walls, Ceiling, etc. so as to match the existing Finishes, complete all as specified and as directed.
M&L for Point Wiring with 1.5 Sqmm Copper Conductor single core PVC insulated FRLSH unsheathed 1100 Volt grade multi-stranded Cable drawn through and including PVC Casing & Caping of suitable size and its Accessories such as Elbow, bends, junction boxes, saddles incl PVC board (ISI Mark) and screws and rawalplug etc on Wall, Ceiling, mounted including PVC insulated FRLSH unsheathed single core multi-stranded Copper Conductor Cable of size 1.5 Sqmm Green in Colour as Earth Continuity Conductor connected to Common Earth and Earth dolly for One Light/ Fan/ Bell Point controlled by One 1-Way Switch 5 Amp, complete all as specified and as directed.
All as per Item no 04 here-in-above, but for One Socket outlet of 3/5 Pin, 5/6 Amp on Same Board, complete all as specified and as directed.
All as per Item no 04 here-in-above, but for One Socket outlet of 3/5 Pin, 5/6 Amp on Independent Board, complete all as specified and as directed.
All as per Item no 04 here-in-above, but wiring with 2.5 Sqmm Copper Conductor for One Socket outlet of 3/5 Pin, 15/16 Amp on Independent Board, complete all as specified and as directed.
M&L Sub-main Wiring with 2-Runs of Single Core 6.0 Sq mm PVC insulated FRLSH multi-stranded 1100 Volts grade with Copper Conductor drawn through and including Non-metalic Rigid PVC Casing capping ISI marked and its Accessories including 1-Run of Single Core 4.00 Sq mm PVC insulated FRLSH unsheated multi-stranded 1100 Volts grade with Copper Conductor Cable as Earth Continuty Conductor along with the Wiring and connected from DB to DB/Main Board, complete all as specified and as directed. NOTE :- (a) Cost of PVC Casing capping with all Fittings/Accessories will deem to be included in the quoted UNIT RATE. (b) Cables as mentioned in SCHEDULE ‘A’ Items and 1-Run of PVC Casing capping with all Fittings/Accessories will be measured and paid as ONE UNIT. (c) Sub-main Wiring will be measured PVC Casing capping only. Wire required for looping, etc as ordered will deem to be included in the quoted UNIT RATE.
M&L Sub-main Wiring with 2-Runs of Single Core 4.0 Sq mm PVC insulated FRLSH multi-stranded 1100 Volts grade with Copper Conductor drawn through and including Non-metalic Rigid PVC Casing capping ISI marked and its Accessories including 1-Run of Single Core 2.50 Sq mm PVC insulated FRLSH unsheated multi-stranded 1100 Volts grade with Copper Conductor Cable as Earth Continuty Conductor along with the Wiring and connected from DB to DB/Main Board, complete all as specified and as directed. NOTE :- (a) Cost of PVC Casing capping with all Fittings/Accessories will deem to be included in the quoted UNIT RATE. (b) Cables as mentioned in SCHEDULE ‘A’ Items and 1-Run of PVC Casing capping with all Fittings/Accessories will be measured and paid as ONE UNIT. (c) Sub-main Wiring will be measured PVC Casing capping only. Wire required for looping, etc as ordered will deem to be included in the quoted UNIT RATE.
M&L Sub-main Wiring with 2-Runs of Single Core 1.5 Sq mm PVC insulated FRLSH multi-stranded 1100 Volts grade with Copper Conductor drawn through and including Non-metalic Rigid PVC Casing capping ISI marked and its Accessories including 1-Run of Single Core 1.00 Sq mm PVC insulated FRLSH unsheated multi-stranded 1100 Volts grade with Copper Conductor Cable as Earth Continuty Conductor along with the Wiring and connected from DB to DB/Main Board, complete all as specified and as directed. NOTE :- (a) Cost of PVC Casing capping with all Fittings/Accessories will deem to be included in the quoted UNIT RATE. (b) Cables as mentioned in SCHEDULE ‘A’ Items and 1-Run of PVC Casing capping with all Fittings/Accessories will be measured and paid as ONE UNIT. (c) Sub-main Wiring will be measured PVC Casing capping only. Wire required for looping, etc as ordered will deem to be included in the quoted UNIT RATE.
S&F Bell push, flush type, 5 Amp, 240 volt complete all as specified and as directed.
S & F Bell Ding-Dong AC 240 V Single Pole complete all as specified and as dircted.
S&F Switch Piano, Flush type, Single Pole, 1-Way, 5 Amps, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F Socket Outlet 2-in-1, Flush type, multi-purpose, 2/3 Pin, 5/6 Amp, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F Switch Socket Combination 2-in-1, Flush type, multi-purpose, 5 Pin, 5/6 Amp, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F Switch Socket Combination 2-in-1, Flush type, multi-purpose, 5/6 Pin, 15/16 Amp, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F Ceiling Rose, Surface Bakelite of size 65x50mm, 3 Terminals, AC, 50 Hz, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F in-repair motor starter for geyser of capacity 16A, 240 Volt,AC, with 3/5 pin, 15/16 Amps socket outlet 2 in 1 complete all as specified and as directed. Cat part no 6730 30 of Make Legrand or equivalent of Make- Havells/Anchor/Bajaj
S&F in-repair PVC surface box, 2-Module with cover plate and frame, complete all as specified and as directed. Cat part no 6733 02 & 6732 42 of Make Legrand or equivalent of Make- Havells/Anchor/Bajaj
S&F of Sheet Metal Enclosure for MCB DP, with MCB Double Pole (DP), 'C' Curve,40 Amps, 240 Volt, 10 kA, 50 Hz, conforming to IS/IEC 60898 and connecting up, complete all as specified and as directed. Make of MCB DP Enclouser & MCB DP Legrand cat part No 5077 91 & 4086 37 or Equivalent in L&T/ Schneider/ Havells
S&F of Sheet Metal Enclosure MCB DB SPN, 8 way 240 volt, with rated Bus-bar, Single door type MCB DB suitable for mounting incoming and outgoing MCBs double pole/ single pole complete all as specified and as directed. Make of DB- Legrand of cat part No 5076 01 or Equivalent in L&T/ Schneider/ Havells
S&F MCB Single Pole & Neutral (SPN), 'C' Curve,40 Amps, 240 Volt for fixing on MCB DB’s, 10 kA, 50 Hz, conforming to IS/IEC 60898 and connecting up, complete all as specified and as directed. Make of MCB SPN 40 Amps Legrand cat part No 4086 18 or Equivalent in L&T/ Schneider/ Havells
S&F MCB Single Pole (SP), 'C' Curve, 6 to 32 Amps, 240 Volt for fixing on MCB DB’s, 10 kA, 50 Hz, conforming to IS/IEC 60898 and connecting up, complete all as specified and as directed. Make of MCB 6 to 32 Amps Legrand cat part No 408587 to 408595 or Equivalent in L&T/ Schneider/ Havells
S&F in-repair GI bracket pipe 0.8m long bend to 45 degree and of 25mm in diameter, including necesary clamps for fixing of building security light complete all as specified and as directed by Engr-in- Charge.
S&F Energy saving new generation environmental friendly long life versatile presure die cast aluminium housing IP 66 security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 30 watts with pre wired and lens embedded PC cover having Top opening seperate driver compartment and necessary mounting arrangements, including taking down old unserviceable light fitting, complete all as specified and as directed. CAT No.- ENDURAPEARLSL30WLED757SASYTOPCMP of Make HAVELLS or equivalent of make BAJAJ/PHILLIPS/CROMPTON GREAVES
S&F in-repair Wall mounted LED 25 Watts, Box type (Decorative) Light Fitting with extruded Aluminium Heat Sink provided for Efficient Heat Dissipation, 240 Volts, complete with all Accessories internally pre-wired and necessary mounting arrangements, with and including of new 2 Core multi-stranded Copper Conductor of size 0.5 Sqmm from Ceiling Rose to Fitting including LED Tube 4'x25 Watts, complete all as specified and as directed. Make- PHILLIPS, Cat Part No.- BN 021 LED25S 6500PSU GR S1 or Equivalent of Make BAJAJ/HAVELLS/CROMPTON GREAVES.
S&F in-repair Wall mounted LED 10 Watts, Box type (Decorative) Light Fitting with extruded Aluminium Heat Sink provided for Efficient Heat Dissipation, 240 Volts, complete with all Accessories internally pre-wired and necessary mounting arrangements, with and including of new 2 Core multi-stranded Copper Conductor of size 0.5 Sqmm from Ceiling Rose to Fitting including LED Tube 2'x10 Watts, complete all as specified and as directed. Make- PHILLIPS, Cat Part No.- BN 021 LED10S 6500PSU GR S1 or Equivalent of Make BAJAJ/HAVELLS/CROMPTON GREAVES.
S&F in repair sleek LED mirror light fitting 09 watt complete all as specified and as directed by Engr -in- charge. Make : Havells, Cat Pt No-LHEXBLP7IN1W009 or equivalent model of Philips/Bajaj/Crompton Greaves etc.
S&F in repair sleek LED Bulk head fitting 6.5 watt complete all as specified and as directed by Engr -in- charge. Make : Havells, Cat Pt No-LHEXCGP7PN5W006 or equivalent model of Philips/Bajaj/Crompton Greaves etc.
RAI CONSTRUCTION
Damdoo Bhutia
Darjeeling Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .