Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹7.9 Cr
EMD Value
₹7.9 L
Closing Date
24 Jan 2022, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Construction of 40 bedded Training Hostel at BHEP, Balimela, Malkangiri, Odisha.
NBCC/PMGSY-ZONE/ODISHA/OHPC/2021/58
NBCC/PMGSY-ZONE/ODISHA/OHPC/2021/58
Open Tender-Domestic
Civil Works General
Malkangiri, Odisha
₹11,800
₹7.9 L
24 Jan 2022
10 Jan 2022
24 Jan 2022
24 Jan 2022
8 Feb 2022
SL NO. DESCRIPTION OF WORK UNIT TOTAL AMOUNT
SL NO. DESCRIPTION OF WORK UNIT TOTAL AMOUNT
A CIVIL WORK Rs. 52623227.70
B PH WORK Rs. 7176457.18
C ELECTRICAL WORK Rs. 12728407.37
D OTHER WORKS(LANDSCAPING+FURNITURE) Rs. 6153522.87
PRIME COST (A+B+C+D) 78681615.12
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
TRAINING HOSTEL (G+2)
1 Earthwork in excavation in ordinary soil for site leveling, foundation,
pits, trenches and other civil works upto and including 1.5metre lift
and stacking the soil upto a lead of 100 metre and including
dewatering, removing slush, shoring and strutting (as required),
complete as per specification and as directed by the Engineer-In-
a. ordinary soils. Cum 538.86 155.34 83708.42
2 Single under reamed pile foundation with RCC M25 using 20 mm
size black hard granite crusher broken chips including cost of borring
but excluding cost of M.S./Tor steel and labour charges for cutting,
bending and binding of steel.
a.Single under reamed pile (7.0m depth)
500 mm dia and 6.0 meter long per 1 pile excavation of bore hole.
i) For each additional depth of 0.5m beyond initial depth of 6.0m up
to 10.0m add extra to the rate per 1 pile.
3 Filling in foundation trenches and plinth, with excavated earth
including laying the earth in layers not exceeding 23.5 cm thick
ramming & watering with all leads & lifts including cost of all
labour,T&P completed as directed by the Engineer-in-charge.
4 Supplying and filling sand in foundation and over areas including
watering, ramming, consolidating and dressing, labours, tools, taxes
etc. all complete as per the specification and direction of Engineer-In-
5 Diluting and injecting chemical emulsion (to be supplied free of cost
at site of work) for PRE CONSTRUCTIONAL Anti-termite treatment
and creating a continuous chemical barrier under and all-round the
column pits, wall trenches, basement excavation, top perimeter of
building, expansion joints, over the top surface of consolidated earth
on which apron is to be laid, surroundings of pipes and conduits etc.
complete as per specifications (plinth area of the building at ground
floor only shall be measured for payment).
6 Providing and laying plain cement concrete 1:3:6 (1 cement: 3
sand: 6 stone aggregate 12mm nominal size) as levelling course in
foundation and plinth etc. including tempering, curring, shuttering
etc.complete all depth and height.
Ground Floor Cum 77.19 4986.69 384922.45
7 First class Fly ash Brick masonry using bricks of size 25 cm. x 12
cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr.
Cm. in cement mortar of mix( 1:6) with ordinary Portland slag
cement(PSC) and screened & washed sand for mortar after
immersing the bricks for 6 (Six) hours in water before use in
Foundation & Plinth including splays cutting, circular moulding,
corbelling, chamfering and similar such type of works, watering and
curing etc. including cost, conveyance, loading, unloading, royalties
and taxes of all materials, cost of all labour, scaffolding, sundries,
T&P required for the works etc. complete in all respect as directed by
the Engineer-in-Charge.
8 First class Fly ash Brick masonry using bricks of size 25 cm. x 12
cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr.
Cm. in cement mortar of mix( 1:6) with ordinary Portland slag
cement(PSC) and screened & washed sand for mortar after
immersing the bricks for 6 (Six) hours in water before use in Super
Structure including splays cutting, circular moulding, corbelling,
chamfering and similar such type of works, watering and curing etc.
including cost, conveyance, loading, unloading, royalties and taxes
of all materials, cost of all labour, scaffolding, sundries, T&P required
for the works etc. complete in all respect as directed by the Engineer-
in-Charge. Digitally signed by RAKESH
RAKESH NARAYAN SINHA
NARAYAN SINHA Date: 2022.01.10 18:01:21
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
Ground floor Cum 166.06 4789.68 795374.26
Second floor Cum 176.76 5420.24 958081.62
Terrace floor Cum 74.83 5808.10 434619.82
9 First class Fly ash Brick masonry using bricks of size 25 cm. x 12
cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr.
Cm. in cement mortar of mix( 1:4) with ordinary Portland slag
cement(PSC) and screened & washed sand for mortar after
immersing the bricks for 4 (Six) hours in water before use in Super
Structure including splays cutting, circular moulding, corbelling,
chamfering and similar such type of works, watering and curing etc.
including cost, conveyance, loading, unloading, royalties and taxes
of all materials, cost of all labour, scaffolding, sundries, T&P required
for the works etc. complete in all respect as directed by the Engineer-
Ground floor Cum 19.11 5015.70 95849.95
First floor Cum 25.95 5309.02 137769.17
Second floor Cum 26.78 5646.26 151206.74
Terrace floor Cum 6.34 6034.11 38241.18
10 Providing, lifting, hoisting and laying Reinforced cement concrete of
M-25 grade as per approved designs and drawings having a
minimum compressive strength (in work test) 250 Kg. / Square cm.
in 15 cm. cubes at 28 days after mixing and test conducted in
accordance with I.S. 516 using 12 mm. to 20 mm. size black hard
crushed broken granite stone chips and screened and washed sharp
sand for mortar of approved quality from approved quarry, washed
and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed
in concrete mixture with Portland slag cement (PSC) including
hoisting, lowering, laying and compaction concrete by using
vibrators, watering and curing for 28 days, centering and shuttering
then after dismantling and removing debris from the work site and
finishing the exposed surface smooth providing grooves or beads
wherever necessary including cost, conveyance, loading, unloading,
royalties and taxes of all materials and cost of all labours, sundries,
T & P required of the work etc. complete in all respect as directed by
the Engineer-in-Charge. But excluding cost and conveyance of M.S.
rods or Tor steel and binding wires and labour charges for
straightening, cutting, bending etc. of M.S. rods or tor steel tying the
grills and placing in proper position.
b) Column up to plinth Cum 11.85 12214.61 144798.07
e) Plinth Beam Cum 49.16 6228.88 306188.38
f) Column above plinth Cum 49.36 12214.61 602919.16
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
11 Cutting, straightening coiled or bent up M.S. Rod or tor steel of SAIL/
TATA / RINL (VIZAG) make including bending, binding, welding and
joining if necessary and tying the grills and placing in position as
required for R.C.C. Work and for providing fan hooks as required,
hoisting, lowering, laying including cost, conveyances, taxes of M.S.
Rod or tor steel and binding wires of 18 to 20 gauge and labour
required for the work for bending, binding and tying the grills in all
floors (Linear measurement will be taken and quantity will be
calculated basing on the standard weight of B.I.S. for M.S. Rods or
tor steel only. Wastage if any, including weight of binding wire will not
be considered for measurement) etc. complete as per specification &
direction of Engineer-in-charge.
Ground floor Qntl 956.78 9478.67 9069000.95
First floor Qntl 345.99 9504.77 3288554.68
Second floor Qntl 349.66 9532.32 3333071.01
Terrace floor Qntl 91.67 9561.10 876497.78
12 12mm cement plaster to out side of brick surfaces with cement
mortar of mix 1:6 (1 cement : 6 fine sand) including necessary
scaffolding, curing etc. all complete at all floors and all heights.
Ground floor Sqm 761.16 152.10 115769.39
First floor Sqm 594.11 155.79 92557.59
Second floor Sqm 589.07 159.49 93949.60
Terrace floor Sqm 449.62 163.41 73471.50
13 16mm cement plaster to inside of brick surfaces with cement mortar
of mix 1:6 (1 cement : 6 fine sand) including necessary scaffolding,
curing etc. all complete at all floors and all heights.
Ground floor Sqm 1840.25 217.28 399849.52
Second floor Sqm 2435.99 228.26 556029.33
Terrace floor Sqm 746.42 233.97 174638.39
14 6 mm cement plaster on RCC surfaces at ceiling/slab soffit and other
locations with cement mortar of mix 1:4 (1 cement : 4 coarse sand)
including necessary scaffolding, curing etc. all complete at all floors
and all heights.
Ground floor Sqm 531.78 170.35 90589.79
First floor Sqm 615.18 174.61 107415.54
Second floor Sqm 458.40 179.09 82093.94
Terrace floor Sqm 365.85 183.57 67158.35
15 Supplying, fitting & fixing of Granite Tiles of minimum Above 0.40
sqm. (20mm thick) of approved make in floors laid on 20 mm thick
cement mortar (1:4) (1 cement : 4 course sand) and filling
joints with slurry including cost of all materials, labour T&P etc.
required for the work all complete incl. rubbing as per direction of the
Engineer-in-charge
Ground floor Sqm 58.00 2458.74 142606.69
First floor Sqm 12.00 2469.60 29635.20
Second floor Sqm 10.40 2481.02 25802.65
16 Supplying, fitting & fixing of Granite Tiles of minimum Above 0.4 sqm
(10mm. thick) of approved make in dadoes laid on 12 mm thick
cement mortar (1:3) (1 cement : 3 course sand) and filling
joints with slurry including cost of all materials, labour T&P etc.
required for the work all complete incl. rubbing as per direction of
the Engineer-in-charge
Ground floor Sqm 10.37 1803.87 18706.15
First floor Sqm 3.96 1820.22 7208.09
Second floor Sqm 3.96 1837.36 7275.95
17 Supplying, fitting & fixing of 10 mm thick & size of 600x600 mm
Glazed Vitrified floor tiles (GVT) of matt finish(WOODEN
FINISH/RUSTIC FINISH) with veilcraft (VC ) shield( Scratch
free/stain free) with water absorption limit between 0.08% to
3% and conforming to IS : 15622:2006 (Group B Ib). laid on 20
mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling
joints with white cement of approved quality including cost of all
materials, labour T&P etc. required for the work all complete as per
direction of the Engineer-in-charge (for New Work only )
Ground Floor Sqm 643.45 1071.50 689459.25
Second floor Sqm 346.91 1093.68 379408.53
Terrace floor Sqm 153.38 1105.66 169586.74
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
18 Supplying, fitting & fixing of 10 mm thick & size of 600x600 mm
Glazed Vitrified floor tiles (GVT) of matt finish(WOODEN
FINISH/RUSTIC FINISH) with veilcraft (VC ) shield( Scratch
free/stain free) with water absorption limit between 0.08% to
3% and conforming to IS : 15622:2006 (Group B Ib) laid on 12 mm
thick cement mortar (1:3) (1 cement : 3 course sand) jointed with
slurry mixed with pigment to match the shades of the tiles etc.
complete including cost of all materials, labour T&P etc. required for
the work all complete as per direction of the Engineer-in-charge
Ground floor Sqm 63.44 1184.18 75124.13
Second floor Sqm 53.70 1217.66 65388.56
Terrace floor Sqm 115.45 1240.62 143230.04
19 Supplying, fitting and fixing of Antiskid Ceramic Floor Tiles in
flooring in toilets using special plain / printed series anti-skid ceramic
floor tile of premium grade (having minimum thickness 7 mm to 8
mm & size 300 mm x 300 mm or 400 mm x 400 mm ) confirming to
I.S 13755 of approved quility and shade on 20mm thick ded of
cement morter of mix (1:4) laid in proper slope and gradient with
screened & washed sharp river sand for mortar and grouted with
neat white cement slurry, joining the anti-skid ceramic floor tiles with
neat white cement slurry, mixed with required (tiles are to be
immersed in the water for required time before use) quantities of
pigments of approved marks to match the shades of the anti-skid
ceramic floor tiles if required including cost, conveyance, loading,
unloading, stacking, royalties of all material, cost of all labour ,
sundries, T&P required for the work , watering,complete in all respect
as per specification excluding GST aas per specification as directed
by Engineer-in-charge.(Note- Sample of tiles shall be approved
before procurement and use.)
Ground floor Sqm 60.77 767.20 46622.74
First floor Sqm 95.53 778.06 74328.45
Second floor Sqm 56.20 789.49 44369.23
Terrace floor Sqm 11.28 801.47 9040.60
20 Supplying, fitting & fixing of 20cmx30cm special plain/ printed series
ceramic wall tiles of premium grade having thickness 6.5mm to
6.7mm confirming to IS 13753 in dadoes, skirting and risers of steps
laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand)
jointed with slurry mixed with pigment to match the shades of the
tiles etc. complete including cost of all materials, labour T&P etc.
required for the work all complete as per direction of the Engineer-in-
Ground floor Sqm 191.64 836.98 160395.57
First floor Sqm 320.63 853.33 273598.29
Second floor Sqm 199.50 870.46 173657.57
Terrace floor Sqm 10.00 888.38 8885.88
21 Providing "RAJSHRI" Brand factory made 100% Solid WPC (
Wood Polymer Composite ) - Door Frame 125 mm x 65 mm Single
Re bated, made from Wood Polymer Composite ( Single Extruded
Process) material comprising of virgin PVC polymer of K Value 57-
60 ( Suspension Grade), Calcium Carbonate and Natural Fibers (
Wood Powder/ Rice Husk/ Wheat Husk) and Nontoxic additives fa br
icated with meter joints after applying PVC solvent Cement&
screwed with full body treaded star headed screws having minimum
fra me density of 780 kg/ cbm& manufactured by "RAJSHRI" an ISO
9001 - 2015 Certified Company, having good screw holding
capacity ( Scr ew Withdrawal strength of ( Min. 990 N ), Minimum
Compressive Strength of 58 N / mm 2, Modulus of elas ticit y
900N/mm2 and r sistance to spread of flame of
c lass /1. category with property of being termite/ borer proof,
water/ Moisture Proof & Fire retardant& f-ixed in pos iti on with
SS Dash f-asteners / Hold f-ast of required dia and length,, all
as per specifications drawings as directed by the En ginee
r- I n-Cha rge. Material test ce r t i ficate and authe nti cation
should be compulsory provided by the manufacturing company (II
old fast or Dash f-as tene rs shall be paid separately)
Ground floor Rmt 98.80 1283.45 126804.43
Second floor Rmt 186.40 1283.45 239234.27
Terrace floor Rmt 51.60 1283.45 66225.79
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
22 Providing "RAJSHRl" Brand Factory Made 30mm thick 100% Solid
WPC ( Wood polymer Composite) Laminated Flus h Door Shutter
of required size comprising of virgin PVC resin of K Value 57-60 (
Suspension Grade), Calcium Carbonat e and natural fibers ( Wood
Powders/ rice husk/ wheat husk ) and Nonto xic additives, made
from Extrusion process WPC foam sheet Single Extruded ( Inner )
with having minimum density not less than 650 kg/cbm
manufactured by "RAJSHRI" an ISO 9 001 - 2015 Certified
Company, having good screw hol di ng capacity ( Screw With d
raw al strength of 2000 N (Face) & 1100 N (Edge), Minimum
Compissive of 50 N/ mm2, Modulus of elasticity 850N/mm2 and
resis t ance of spread of flame of Class A category with Property of
being Termite/ Borer r ree. Water/ Moisture Proof and Fire
Retardant. WPC to be Laminated with PVC foil of minimum 14
microns thick of app roved design pasted on both faces of shutter
and fixing stainless Steel butt hinges of required size with necessary
full body threaded star headed counter sunk SS Scr ews . All as
per direction of Engineer -In-Charge, Material test certificate and
authentication sho uld be compulsory
p rov i d ed by the manufacturing company: For
WC/Bathroom/Toilet/Kitchen/Balconv Doors.
Ground floor Sqm 39.90 4888.33 195044.30
First floor Sqm 59.85 4888.33 292566.45
Second floor Sqm 73.92 4888.33 361345.22
Terrace floor Sqm 20.16 4888.33 98548.70
23 Providing & fixing of Factory fabricated WINPLUS® Aluminium Door
Systems - For openable windows, made from 6063 alloy and T-6
tempered aluminium profile, in approved shade of hybrid
/purepolyster surface coating (50-60micron Powder Coat),
mechanically mitred & jointed with casted / aluminium extruded
corner cleats along with openable door Flush Lock, Bearing Rollers ,
Siliconised Weather strip and 9 mm clear glass as infill shall be fitted
into Shutter using siliconised microwave treated EPDM gaskets
excluding taxes of all materials and cost of all labours required for
the work etc. complete in all respect as desired by the Engineer in
charge. Note - conveyance, T&P and scaffolding are not included
Ground floor Sqm 3.15 8435.84 26572.90
24 Factory made FRP( Altematly called GRP) door frame of size
75mm x 100mm fabricated using E - glass chopped strand mat
(CSM) U.V stabilised inopathalic Gel coat and impregnated with
inopathalic resin The thickness of the GRP skins shall not be less
then 2.0 mm . The door frame consists of four segments which are
provided with plug in socket arrrangement in-situ-in mould. The
segments are plugged in and are joined together by means of srew.
The GRP frame shall be provided with wooden reinforcement on six
locations for high srew holding capacity for fixing metalic hold fast
and shall be consolidated by filling with medium density foam /
plaster of paris with fibre reinforcement , six number of 260mm x
25mm x 5mm size 'S' shaped M.S flat hold fast shall be provided
with the frame. The material and process for manufacturing the finish
of door frame shall conform to RV-TIFAC composites Design
centre's standards and specifications . The finish of door frame will
be plain colour white /Ivory/Beige/Light grey / Golden brown /
Mahogany/ Teak wood /sand stone Champagne/Pastel blue or any
other colour using high quality pigment complete in all respect as per
specification and direction of the Engineer in Charge. etc. complete
First floor Rmt 59.40 580.75 34496.76
Second floor Rmt 79.20 580.75 45995.69
Terrace floor Rmt 9.90 580.75 5749.46
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
25 Factory made GIRID FRP or called GRP sandwich composite door
shutter of 32mm thick laminated with two GRP skin with good grain
finish fabricated using UV stabilised isoppthalic gel coat and one
layer of 450 gsm E-glass chopped strand mat (CSM) impregnated
with ortopathilic resin The thickness of the skins shall not be less
than 1.50mm . Expanded polysryne ( EPS) structural foam panel of
29 mm tickness and a density of 20kg/cu.mts shall be used as core
material wooden reinforcements made of sesasoned sal wood block
of cross section not less than 28mm x 32mm and also necessary sal
wood reinforcements for fitting the metal fittings such as lower bolts
,aldrops, handles etc. shall be provided . A structural adhesive
compatible with (EPS)foam shall be used for bending the core
material. the sal wood reinforcements and the skin The material and
process for manufactuing te door shutter shall conform to RV -
TIFAC components design centre's standards and specification and
the door shutters tested in conformation to IS 4020-1998. The Finish
of door shutter will be plain colour as per specification and
direction of the Engineer in Charge. etc. complete
First floor Sqm 18.90 3902.06 73748.89
Second floor Sqm 25.20 3902.06 98331.85
Terrace floor Sqm 3.15 3902.06 12291.48
26 Providing & Fixing pristine white UPVC framed sliding glazed
windows make :Komerling Company must have own production
facilities(extrusion & fabrication) & control the entire cycle from
Extrusion to Installation to post sales service.Providing & Fixing of
factory made uPVC sliding window (whilte colour) complete,
comprising uPVC multi-chambered frame having in-built uPVC roller
track on top & uPVC sash with wall thickness of 2.0mm(+-0.2) duly
reinforced with G.I section 1.6mm , profile shall be manufactured
from tropicalized blend with TiO2 & required addictives.Profile must
be colorfast and conform to standard EN12608.The profile sections
should have multi hollow (min 2 to 3 chambers) chamber to include
GI reinforcement with 120 GSM zinc coated,fitted in continuous
length, in closed chamber. The thckness of GI should be selected to
meet the wind load requirement as per IS 875-Part III on
sash/mullion.Supplier should be submitting wind load calculation &
validation complying with IS -845-III before materila supply.Minimum
steel reinforcement thickness of 1.2mm to 2.5 mm.UPVC windows &
doors must be fabricated with fusion welded corners & must.
Ground floor Sqm 35.19 9484.29 333752.32
First floor Sqm 47.12 9484.29 446899.95
Second floor Sqm 43.07 9484.29 408488.56
Terrace floor Sqm 18.23 9484.29 172851.27
27 Supplying and Fixing of M.S. Grills, M.S.Doors, M.S. Gate etc
including cost,conveyance of all materials,priming,and labour for
fitting fixing etc.complete as per the instruction of Engineer-in-
Ground floor Kg 738.99 69.66 51481.00
First floor Kg 989.42 69.66 68926.95
Second floor Kg 1076.63 69.66 75002.35
Terrace floor Kg 455.63 69.66 31740.66
28 Priming one coat with wall cement primer (water bound) to make an
even finished surface in all floors and heights to wall surface of
approved make and shade including sand papering, applying putty
wherever necessary & cost of scaffolding, staging charges with cost,
conveyance, taxes of all materials, cost of all labour,labour cess T&P
etc. complete as per the direction of the Engineer-in-charge.
Ground floor Sqm 2941.55 67.20 197672.16
First floor Sqm 3055.17 68.88 210440.11
Second floor Sqm 3283.96 70.56 231716.22
Terrace floor Sqm 1561.89 72.24 112830.93
29 Painting two coats with approved anti-fungal weather seal paints (ISI)
of approved colour, shade on wall surface over a coat of wall
primer(ISI) water bound including sand papering, polishing the
surface, cost, conveyances of all materials and cost of all
labour,labour cess with T&P etc, complete as per specification &
direction of Engineer-in-charge.
Ground floor Sqm 761.16 82.88 63084.94
First floor Sqm 594.11 85.79 50969.89
Second floor Sqm 589.07 88.82 52318.84
Terrace floor Sqm 449.62 92.06 41393.82
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
30 Finishing plastered surfaces of walls with cement based wall putty
(Water based) of approved make and finishing the surface smooth
and even by sand papering to receive painting in walls, at all heights
with staging wherever necessary with cost, conveyance, taxes of all
materials, cost of all labour,labourcess, all T&P etc. required for the
work complete in all respect as per the direction of the Engineer-in-
Ground floor Sqm 2941.55 73.70 216780.47
First floor Sqm 3055.17 73.70 225153.81
Second floor Sqm 3283.96 73.70 242014.72
Terrace floor Sqm 1112.27 73.70 81969.85
31 Painting two coats with approved plastic emulsion paint over a coat
of wall primer of make Dulux / Berger / Asian to inside surface of
walls finished with Acrylic Wall putty (water based) of make (Birla /
JK) and finished smooth & even surface to receive painting using
roller to the final coat including cost of scaffolding staging charges
with cost, conveyances, taxes of all materials, cost of labour, T&P
required for the work etc. complete for all floors as per specification
& direction of the Engineer-in-charge.
Note :- Sample of Paint & Primer shall be approved before
procurement and use.
Ground floor Sqm 2180.39 90.16 196583.96
First floor Sqm 2461.06 91.95 226299.39
Second floor Sqm 2694.89 93.74 252629.77
Terrace floor Sqm 1112.27 95.54 106261.83
32 Painting two coats with approved Enamel Paint on Steel work in
Ground floor Sqm 38.71 153.10 5926.66
First floor Sqm 51.83 156.91 8132.75
Second floor Sqm 47.37 160.94 7623.92
Terrace floor Sqm 20.05 165.09 3310.01
33 Supplying, fitting and fixing of Stainless steel of 304 grade in hand
ralling using 50mm dia of 2mm thick circular pipe with Balustrade of
size 32mm X 32mm X 2mm @ 0.90mtr. C/C and stainless square
pipe bracing of size 32mm X 32mm X 2mm in 3 rows in stair case as
per approved design and specification, buffing, polishing etc with
cost, conveyance, taxes, all materials, labour, T&P etc. required for
the complete in all respect.
Ground floor Kg 286.88 323.68 92857.32
Second floor Kg 286.88 323.68 92857.32
34 2.5 cm thick grading concrete (1:2:2) on roof slab with 6.7mm &
down grades size hard granite crusher broken chips on new work in
Terrace floor Sqm 354.00 428.62 151732.90
35 Providing and fixing of self supported mechanically seamed roofing
system made of high quality having imported color coated galvalume
steel having 340mpa yield strength ,pre coated galvalume sheet as
per ASTM A 792M base metal of thickness 0.80mm to 1.60mm and
american hydraulic machine for the process of 1.6mm base metal
thickness sheet.
Ground floor Sqm 262.00 3032.96 794635.52
36 Making plinth protection 50mm thick of cement concrete 1:3:6 (1
cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal
size) over 75mm bed of dry brick ballast 40mm nominal size well
ramed, consolidated and grouted with fine sand and finishing the top
smooth including shuttering at the edges, excavation and disposing
of surplus earth with a lead of 100m.
Ground floor Sqm 105.98 589.57 62482.42
37 Providing & Fixing of Armstrong Mineral Fibre Suspended Ceiling
System with Bioguard (Bevelled Tegular) EDGE TILES WITH
ARMSTRONG 15mm Exposed GRID. The tiles should have
Humidity Resistance (RH) of 95%, Light Reflectance 90%, Thermal
Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire
Performance UK Class 0/Class 1 (BS 476 Part 6 & 7), in module size
of 600x600 x 15mm with Anti Microbial coating on the face of the tile,
suitable for Green Building application, with Recycled content of
34%. The tile shall be laid on Armstrong Silhouette profile grid
system with 15mm white flanges incorporating a 6mm central reveal
in white/black colour and with a web height of 45mm and a load
carrying capacity of minimum 15.68 Kgs/M2 & minimum pull out
strength of 100 kgs.. Silhouette, Main Runners & Cross Tees to have
mitred ends & “birdsmouth” notches to provide mitred cruciform
junctions. The T Sections have a Galvanizing of 90 grams per M2
and need to be installed with suspension system of Armstrong make.
The Tile & Grid system used together should carry a 30 year
warranty including all cost, conveyance, all labour and T&P etc.
complete in all respect as directed by Engineer-in-charge.
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
Ground floor Sqm 262.00 1742.61 456563.30
38 Providing and applying integral crystalline slurry of hydrophilic in
nature for waterproofing treatment to the RCC structures like
retaining walls of the basement, water tanks, roof slabs, podiums,
reservior, sewage & water treatment plant, tunnels / subway and
bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts
integral crystalline slurry : 2 parts water) for vertical surfaces and 3 :
1 (3 parts integral crystalline slurry : 1 part water) for horizontal
surfaces and applying the same from negative (internal) side with the
help of synthetic fiber brush. The material shall meet the 0.00 0.00
requirements as specified in ACI-212-3R-2010 i.e by reducing
permeability of concrete by more than 90% compared with control
concrete as per DIN 1048 and resistant to 16 bar hydrostatic
pressure on negative side. The crystalline slurry shall be capable of
self-healing of cracks up to a width of 0.50mm. The work shall be
carried out all complete as per specification and the direction of the
engineer-incharge. The product performance shall carry guarantee
for 10 years against
Ground floor Sqm 354.00 466.39 165102.20
Providing and laying water proofing treatment in sunken portion of
WCs, bathroom etc., by applying cement slurry mixed with water
proofing cement compound consisting of applying : (a) First layer of
slurry of cement @ 0.488 kg/sqm mixed with water proofing cement
compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for
4hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed
with water proofing cement compound @ 0.126 kg/sqm. This layer
will be allowed to air cure for 4 hours followed with water curing for
48 hours. The rate includes preparation of surface, treatment and
sealing of all joints,corners, junctions of pipes and masonry with
polymer mixed slurry.
Ground floor Sqm 233.62 297.08 69402.34
LAND DEVELOPMENT
1 Supplying and filling sand in foundation and over areas including
watering, ramming, consolidating and dressing, labours, tools, taxes
etc. all complete as per the specification and direction of Engineer-In-
2 Clearing grass and removal of rubbish up to adistance of 50 metres
outside the periphery of the area.
1 Earthwork in excavation in ordinary soil for site leveling, foundation,
pits, trenches and other civil works upto and including 1.5metre lift
and stacking the soil upto a lead of 100 metre and including
dewatering, removing slush, shoring and strutting (as required),
complete as per specification and as directed by the Engineer-In-
2 Filling at all depth with available excavated earth (excluding rock) in
trenches, plinth, sides of foundations etc. in layers not exceeding
15cm in depth: consolidating each deposited layer by ramming and Cum 75.60 86.35 6528.21
watering complete (lead upto 100m) as directed by the Engineer-In-
Loosening levelling & compacting original ground suppourting
embankment to facilitate a placement of 1st layer of embankment up
to a depth of 150mm mixed with water at OMC & then and then
compacted by rolling as per Clause 300.20 for embankment
construction as per Clause No- 305.3.4 of MoRTH specifiction.
Providing, laying, spreading and compacting graded stone aggregate
to Wet Mix Macadam specification including premixing the material
with water at OMC in mechanical mix plant, carriage of mixed
material by tipper to site, laying in uniform layers with paver in sub- Cum 75.20 2438.50 183375.02
base/base course on well prepared surface and compacting with
vibratory roller to achieve the desired density as per Clause 406 of
MoRT&H Specifications for Road & Bridge works
Providing close graded granular subbase with Grading-lll materials
6 Providing and laying 80 mm thick factory made cement concrete
interlocking paver block of M-30 grade made by block making
machine with storng vibratory compaction of approved size, design &
shape, laid in required colour and pattern over and including 75mm
thick sand filling.as per drawing, specification and direction of
Engineer-In-charge.
GICO Tile (GPT-1, 4 & 6) Red and Yellow colour Sqm 376.00 867.89 326325.89
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
Construction of cement concrete kerb with top and bottom width 115
and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10
grade foundation 150mm thick, foundation having 50mm projection
beyond kerb stone, kerb stone laid with kerb laying machine,
foundation concrete laid manually, all complete as per clause 408
8 Providing & Painting with synthetic enamel paint of approved brand
and manufacture to give an even shade as per the instruction of
Engineer-In-Charge at all floors and all heights including all material
& labour complete.
1 Earthwork in excavation in ordinary soil for site leveling, foundation,
pits, trenches and other civil works upto and including 1.5metre lift
and stacking the soil upto a lead of 100 metre and including
dewatering, removing slush, shoring and strutting (as required),
complete as per specification and as directed by the Engineer-In-
2 Single under reamed pile foundation with RCC M25 using 20 mm
size black hard granite crusher broken chips including cost of borring
but excluding cost of M.S./Tor steel and labour charges for cutting,
bending and binding of steel.
a.Single under reamed pile (3.0m depth)
375 mm dia and 6.0 meter long per 1 pile excavation of bore hole.
3 Filling at all depth with available excavated earth (excluding rock) in
trenches, plinth, sides of foundations etc. in layers not exceeding
15cm in depth: consolidating each deposited layer by ramming and
watering complete (lead upto 100m) as directed by the Engineer-In-
Ground Floor (Compound Wall) Cum 27.98 86.35 2416.06
4 Providing and laying plain cement concrete 1:4:8 (1 cement : 4 sand
: 8 stone agregate 40mm nominal size) as levelling course in floor
and plinth including tempering, curring, shuttering etc. complete all
depth and height.
Ground Floor (Compound Wall) Cum 10.44 4593.90 47960.36
Fly Ash. brick masonry of size 23 cm. x 12 cm. x 8 cm. having
crushing strength not less than 75 kg. Per Sqr. Cm. in cement mortar
of mix (1:6) with approved grade cement and screened & washed
sand for mortar after immersing the bricks for 6 (Six) hours in water
before use in foundation & plinth including splays cutting, circular
moulding, corbelling, chamfering and similar such type of works,
watering and curing etc. including cost, conveyance, loading,
unloading, royalties and taxes of all materials, cost of all labour,
scaffolding, sundries, T&P required for the works etc. complete in all
respect as directed by the Engineer-in-charge
Ground Floor (Compound Wall) Cum 13.05 4746.78 61945.53
Fly Ash. brick masonry of size 23 cm. x 12 cm. x 8 cm. having
crushing strength not less than 75 kg. Per Sqr. Cm. in cement mortar
of mix (1:6) with approved grade cement and screened & washed
sand for mortar after immersing the bricks for 6 (Six) hours in water
before use in Superstructure including splays cutting, circular
moulding, corbelling, chamfering and similar such type of works,
watering and curing etc. including cost, conveyance, loading,
unloading, royalties and taxes of all materials, cost of all labour,
scaffolding, sundries, T&P required for the works etc. complete in all
respect as directed by the Engineer-in-charge
Ground Floor (Compound Wall) Cum 82.65 4789.68 395867.05
RCC work M-25 grade as per approved designs and drawings having
a minimum compressive strength (in work test) 20 N. / Square mm.
in 15 cm. cubes at 28 days after mixing and test conducted in
accordance with I.S. 456 and I.S. 516 using 12 mm. to 20 mm. size
black hard crusher broken granite stone chips and screened and
washed sharp sand for mortar of approved quality from approved
quarry, washed and cleaned (20 mm. size chips not to exceed 25 %
) to be mixed in concrete mixture with approved grade cement
including hoisting, lowering, laying and compacting concrete by using
vibrators, watering and curing for 28 days, centring and shuttering
and finishing the exposed surface smooth providing grooves or
beads wherever necessary including cost, conveyance, loading,
unloading, royalties and taxes of all materials and cost of all labours,
sundries, T&P, required for the work etc. complete in all respect but
excluding cost and conveyance of M.S. rods or Tor steel and binding
wires and labour charges for straightening, cutting, bending etc. of
M.S. rods or Tor steel tying the grills and placing in proper position
as per direction of the Engineer in charge
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
d)Column up to 1.88m lvl :- Cum 6.35 12214.61 77501.69
e)Coping at top of compound wall Cum 7.83 12214.61 95640.38
Cutting, straightening coiled or bent up M.S. Rod or tor steel of SAIL/
TATA / RINL (VIZAG) make including bending, binding, welding and
joining if necessary and tying the grills and placing in position as
required for R.C.C. Work and for providing fan hooks as required,
hoisting, lowering, laying including cost, conveyances, taxes of M.S.
Rod or tor steel and binding wires of 18 to 20 gauge and labour
required for the work for bending, binding and tying the grills in all
floors (Linear measurement will be taken and quantity will be
calculated basing on the standard weight of B.I.S. for M.S. Rods or
tor steel only. Wastage if any, including weight of binding wire will not
be considered for measurement) etc. complete as per specification &
direction of Engineer-in-charge.
9 Providing 12mm. Thick cement plaster in cement mortar or mix(1:6)
in all floors at all height with cement & screened and washed sharp
river sand for mortar and finished smooth to the rough surface of the
brick masonary walls after racking out the joints (alongwith providing
grooves wherever necessary) including watering and curing,rounding
of corners etc. complete with cost, conveyance, loading, unloading,
royalities and taxes of all materials,cost of all labour,T&P, and
scaffolding required for the work etc. as directed by the Engineer-in-
Gr. Floor(Compound Wall) Sqm 348.00 152.10 52929.41
10 Providing 6 mm thick cement plaster with cement mortar of mix (1:4)
with screened and washed sharp sand for mortar and finished
smooth to R.C.C. work after closed deep chipping & slurry treatment
including watering and curing, rounding of corners, providing grooves
where ever necessary with cost, conveyance, royalties and taxes of
all materials with cost of all labour, T&P, and scaffolding required for
the work etc. complete in all respect as directed by the Engineer in
Gr. Floor(Compound Wall) Sqm 354.58 170.35 60403.41
Providing 16 mm thick cement plaster with cement mortar of mix
(1:6) with screened and washed sharp sand for mortar and finished
smooth to the rough surface of walls in all heights after racking out
joints including watering and curing, rounding of corners, providing
grooves where ever necessary with cost, conveyance, royalties and
taxes of all materials with cost of all labour,labour cess, T&P, and
scaffolding required for the work etc. complete in all respect as
directed by the Engineer in charge.
Gr. Floor(Compound Wall) Sqm 354.58 217.28 77043.14
Priming one coat with wall cement primer (water bound) to make an
even finished surface in all floors and heights to wall surface of
approved make and shade including sand papering, applying putty
wherever necessary & cost of scaffolding, staging charges with cost,
conveyance, taxes of all materials, cost of all labour,labour cess T&P
etc. complete as per the direction of the Engineer-in-charge.
Gr. Floor(Compound Wall) Sqm 766.96 67.20 51539.71
13 Painting two coats with approved anti-fungal weather seal paints (ISI)
of approved colour, shade on wall surface over a coat of wall
primer(ISI) water bound including sand papering, polishing the
surface, cost, conveyances of all materials and cost of all
labour,labour cess with T&P etc, complete as per specification &
direction of Engineer-in-charge.
Gr. Floor(Compound Wall) Sqm 766.96 82.88 63565.64
SECURITY ROOM & GATE COMPLEX
1 Earthwork in excavation in ordinary soil for site leveling, foundation,
pits, trenches and other civil works upto and including 1.5metre lift
and stacking the soil upto a lead of 100 metre and including
dewatering, removing slush, shoring and strutting (as required),
complete as per specification and as directed by the Engineer-In-
2 Single under reamed pile foundation with RCC M25 using 20 mm
size black hard granite crusher broken chips including cost of borring
but excluding cost of M.S./Tor steel and labour charges for cutting,
bending and binding of steel.
a.Single under reamed pile (4.0m depth)
375 mm dia and 4.0 meter long per 1 pile excavation of bore hole.
3 Filling in foundation trenches and plinth, with excavated earth
including laying the earth in layers not exceeding 23.5 cm thick
ramming & watering with all leads & lifts including cost of all
labour,T&P completed as directed by the Engineer-in-charge.
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
4 Supplying and filling sand in foundation and over areas including
watering, ramming, consolidating and dressing, labours, tools, taxes
etc. all complete as per the specification and direction of Engineer-In-
Diluting and injecting chemical emulsion (to be supplied free of cost
at site of work) for PRE CONSTRUCTIONAL Anti-termite treatment
and creating a continuous chemical barrier under and all-round the
column pits, wall trenches, basement excavation, top perimeter of Sqm 43.38 154.56 6704.81
building, expansion joints, over the top surface of consolidated earth
on which apron is to be laid, surroundings of pipes and conduits etc.
complete as per specifications (plinth area of the building at ground
floor only shall be measured for payment).
6 Providing and laying plain cement concrete 1:4:8 (1 cement : 4 sand
: 8 stone agregate 40mm nominal size) as levelling course in floor
and plinth including tempering, curring, shuttering etc. complete all
depth and height.
7 Providing and laying plain cement concrete 1:2:4 (1 cement: 2
sand: 4 stone aggregate 12mm nominal size) as levelling course in
foundation and plinth etc. including tempering, curring, shuttering
etc.complete all depth and height.Ground Floor
8 First class Fly ash Brick masonry using bricks of size 25 cm. x 12
cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr.
Cm. in cement mortar of mix( 1:6) with ordinary Portland slag
cement(PSC) and screened & washed sand for mortar after
immersing the bricks for 6 (Six) hours in water before use in
Foundation & Plinth including splays cutting, circular moulding, Cum 3.60 4746.78 17088.42
corbelling, chamfering and similar such type of works, watering and
curing etc. including cost, conveyance, loading, unloading, royalties
and taxes of all materials, cost of all labour, scaffolding, sundries,
T&P required for the works etc. complete in all respect as directed by
the Engineer-in-Charge.
9 First class Fly ash Brick masonry using bricks of size 25 cm. x 12
cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr.
Cm. in cement mortar of mix( 1:6) with ordinary Portland slag
cement(PSC) and screened & washed sand for mortar after
immersing the bricks for 6 (Six) hours in water before use in Super
Structure including splays cutting, circular moulding, corbelling,
chamfering and similar such type of works, watering and curing etc.
including cost, conveyance, loading, unloading, royalties and taxes
of all materials, cost of all labour, scaffolding, sundries, T&P required
for the works etc. complete in all respect as directed by the Engineer-
Ground floor Cum 14.40 4789.68 68971.39
Providing, lifting, hoisting and laying Reinforced cement concrete of
M-25 grade as per approved designs and drawings having a
minimum compressive strength (in work test) 250 Kg. / Square cm.
in 15 cm. cubes at 28 days after mixing and test conducted in
accordance with I.S. 516 using 12 mm. to 20 mm. size black hard
crushed broken granite stone chips and screened and washed sharp
sand for mortar of approved quality from approved quarry, washed
and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed
in concrete mixture with Portland slag cement (PSC) including
hoisting, lowering, laying and compaction concrete by using
vibrators, watering and curing for 28 days, centering and shuttering
then after dismantling and removing debris from the work site and
finishing the exposed surface smooth providing grooves or beads
wherever necessary including cost, conveyance, loading, unloading,
royalties and taxes of all materials and cost of all labours, sundries,
T & P required of the work etc. complete in all respect as directed by
the Engineer-in-Charge. But excluding cost and conveyance of M.S.
rods or Tor steel and binding wires and labour charges for
straightening, cutting, bending etc. of M.S. rods or tor steel tying the
grills and placing in proper position.
d) Column up to plinth Cum 0.86 12214.61 10553.42
e) Plinth Beam Cum 2.16 6228.88 13454.38
f) Column above plinth Cum 7.92 12214.61 96739.70
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
Cutting, straightening coiled or bent up M.S. Rod or tor steel of SAIL/
TATA / RINL (VIZAG) make including bending, binding, welding and
joining if necessary and tying the grills and placing in position as
required for R.C.C. Work and for providing fan hooks as required,
hoisting, lowering, laying including cost, conveyances, taxes of M.S.
Rod or tor steel and binding wires of 18 to 20 gauge and labour
required for the work for bending, binding and tying the grills in all
floors (Linear measurement will be taken and quantity will be
calculated basing on the standard weight of B.I.S. for M.S. Rods or
tor steel only. Wastage if any, including weight of binding wire will not
be considered for measurement) etc. complete as per specification &
direction of Engineer-in-charge.
Ground floor Qntl 42.59 9478.67 403710.38
12 12mm cement plaster to out side of brick surfaces with cement
mortar of mix 1:6 (1 cement : 6 fine sand) including necessary
scaffolding, curing etc. all complete at all floors and all heights.
Ground floor Sqm 72.00 152.10 10950.91
13 16mm cement plaster to inside of brick surfaces with cement mortar
of mix 1:6 (1 cement : 6 fine sand) including necessary scaffolding,
curing etc. all complete at all floors and all heights.
Ground floor Sqm 57.60 217.28 12515.33
14 6 mm cement plaster on RCC surfaces at ceiling/slab soffit and other
locations with cement mortar of mix 1:4 (1 cement : 4 coarse sand)
including necessary scaffolding, curing etc. all complete at all floors
and all heights.
Ground floor Sqm 11.52 170.35 1962.46
Supplying, fitting & fixing of 10 mm thick & size of 600x600 mm
Glazed Vitrified floor tiles (GVT) with veilcraft (VC ) shield( Scratch
free/stain free) with water absorption limit between 0.08% to 3%
and conforming to IS : 15622:2006 (Group B Ib). laid on 20 mm thick
cement mortar (1:4) (1 cement : 4 course sand) and filling joints with
white cement of approved quality including cost of all materials,
labour T&P etc. required for the work all complete as per direction of
the Engineer-in-charge (for New Work only )
Ground floor Sqm 11.52 1071.50 12343.73
Supplying, fitting & fixing of 10 mm thick & size of 600x600 mm
Glazed Vitrified floor tiles (GVT) with veilcraft (VC ) shield( Scratch
free/stain free) with water absorption limit between 0.08% to 3%
and conforming to IS : 15622:2006 (Group B Ib) laid on 12 mm thick
cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry
mixed with pigment to match the shades of the tiles etc. complete
including cost of all materials, labour T&P etc. required for the work
all complete as per direction of the Engineer-in-charge
Ground floor Sqm 2.88 1184.18 3410.43
Providing and fixing seasoned sal wood work in frames at any
locations including doors, windows,cupboard, clerestory and other
frames fixing in position including cost of hinges, M.S. flat (30mm x
6mm) hold fasts lugs or dash fasteners of required dia and length as
per drawing / specification, at all floors and all heights.
Ground floor Cum 0.08 55384.78 4536.01
1 Factory made 30mm/32mm flush door shutter (Laminates both side
of frame) with all labour, iron fittings, and wooden hinged cleats etc
fitted and fixed complete in all respect
First floor Sqm 4.20 4021.02 16888.30
Providing & Fixing pristine white UPVC framed sliding glazed
windows with Stainless stell mesh make :Komerling.Company must
have own production facilities(extrusion & fabrication) & control the
entire cycle from Extrusion to Installation to post sales
service.Providing & Fixing of factory made uPVC sliding window
(whilte colour) complete, comprising uPVC multi-chambered frame
having in-built uPVC roller track on top & uPVC sash with wall
thickness of 2.0mm(+-0.2) duly reinforced with G.I section 1.6mm ,
profile shall be manufactured from tropicalized blend with TiO2 &
required addictives.Profile must be colorfast and conform to
standard EN12608.The profile sections should have multi hollow
(min 2 to 3 chambers) chamber to include GI reinforcement with 120
GSM zinc coated,fitted in continuous length, in closed chamber. The
thckness of GI should be selected to meet the wind load requirement
as per IS 875-Part III on sash/mullion.Supplier should be submitting
wind load calculation & validation complying with IS -845-III before
materila supply.Minimum steel reinforcement thickness of 1.2mm to
2.5 mm.UPVC windows & doors must be fabricated with fusion
welded corners & must.
Ground floor Sqm 3.24 9484.29 30729.11
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
25 Supplying and Fixing of M.S. Grills, M.S.Doors, M.S. Gate etc
including cost,conveyance of all materials,priming,and labour for
fitting fixing etc.complete as per the instruction of Engineer-in-
Ground floor Kg 558.00 69.66 38872.51
Priming one coat with wall cement primer (water bound) to make an
even finished surface in all floors and heights to wall surface of
approved make and shade including sand papering, applying putty
wherever necessary & cost of scaffolding, staging charges with cost,
conveyance, taxes of all materials, cost of all labour,labour cess T&P
etc. complete as per the direction of the Engineer-in-charge.
Ground floor Sqm 72.00 67.20 4838.40
27 Painting two coats with approved anti-fungal weather seal paints (ISI)
of approved colour, shade on wall surface over a coat of wall
primer(ISI) water bound including sand papering, polishing the
surface, cost, conveyances of all materials and cost of all
labour,labour cess with T&P etc, complete as per specification &
direction of Engineer-in-charge.
Ground floor Sqm 72.00 82.88 5967.36
28 Finishing plastered surfaces of walls with cement based wall putty
(Water based) of approved make and finishing the surface smooth
and even by sand papering to receive painting in walls, at all heights
with staging wherever necessary with cost, conveyance, taxes of all
materials, cost of all labour,labourcess, all T&P etc. required for the
work complete in all respect as per the direction of the Engineer-in-
Ground floor Sqm 141.12 73.70 10399.98
29 Painting two coats with approved plastic emulsion paint over a coat
of wall primer of make Dulux / Berger / Asian to inside surface of
walls finished with Acrylic Wall putty (water based) of make (Birla /
JK) and finished smooth & even surface to receive painting using
roller to the final coat including cost of scaffolding staging charges
with cost, conveyances, taxes of all materials, cost of labour, T&P
required for the work etc. complete for all floors as per specification
& direction of the Engineer-in-charge.
Note :- Sample of Paint & Primer shall be approved before
procurement and use.
Ground floor Sqm 69.12 90.16 6231.86
30 Painting two coats with approved Enamel Paint on wood work over a
coat of Wood Primer
Ground floor Sqm 2.60 218.40 567.84
31 Painting two coats with approved Enamel Paint on Steel work
Ground floor Sqm 4.62 153.10 707.34
DRAINAGE WORKS.
1 Earthwork in excavation in ordinary soil for site leveling, foundation,
pits, trenches and other civil works upto and including 1.5metre lift
and stacking the soil upto a lead of 100 metre and including
dewatering, removing slush, shoring and strutting (as required),
complete as per specification and as directed by the Engineer-In-
2 Filling at all depth with available excavated earth (excluding rock) in
Drain sides in layers not exceeding 12 cm in depth: consolidating
each deposited layer by ramming and watering complete all as per
the directed of the Engineer-In-charge.
3 Supplying & filling of approved river sand in Drain and over areas
including watering,ramming, consolidating and dressing, labours,
tools, taxes etc. all complete as per the specification and direction of
Engineer-In-charge.
Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand :
8 stone agregate 40mm nominal size) as levelling course in Drain Cum 11.93 4593.90 54782.31
etc. including tempering, curring, shuttering etc. complete all depth
and height as per the direction of Engineer-In-charge.
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
Providing, lifting, hoisting and laying Reinforced cement concrete of
M-25 grade as per approved designs and drawings having a
minimum compressive strength (in work test) 250 Kg. / Square cm.
in 15 cm. cubes at 28 days after mixing and test conducted in
accordance with I.S. 516 using 12 mm. to 20 mm. size black hard
crushed broken granite stone chips and screened and washed sharp
sand for mortar of approved quality from approved quarry, washed
and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed
in concrete mixture with Portland slag cement (PSC) including
hoisting, lowering, laying and compaction concrete by using
vibrators, watering and curing for 28 days, centering and shuttering
then after dismantling and removing debris from the work site and
finishing the exposed surface smooth providing grooves or beads
wherever necessary including cost, conveyance, loading, unloading,
royalties and taxes of all materials and cost of all labours, sundries,
T & P required of the work etc. complete in all respect as directed by
the Engineer-in-Charge. But excluding cost and conveyance of M.S.
rods or Tor steel and binding wires and labour charges for
straightening, cutting, bending etc. of M.S. rods or tor steel tying the
grills and placing in proper position.
Drain Bottom slab Cum 11.90 5818.06 69234.96
Supplying, straightening, cutting, bending, placing in position and
binding reinforcement steel work in RCC/Reinforced brick works as
per drawing and specification including preparation of respective bar Qntl 54.84 9478.67 519810.37
bending schedule and binding (Binding wire to be used as per the IS
code) etc. all complete as per direction of Engineer-In-Charge. Cold
Twisted bars, Thermo-Mechanically-treated bars.
8 12mm cement plaster on internal RCC/brick surfaces in cement
mortar 1:4 (1 cement : 4 coarse sand) with a floating coat of neat
cement punning including necessary scaffolding, curing etc. all
complete at all floors and all heights.
1 Surface dressing of the ground including removing Vegetation and
making up undulations and in-equalities not exceeding 15 cms in
depth/ height including disposal of rubbish lead upto 50m (at least
5m away from the dressed area).
2 Supplying and stacking of good earth at site including royalty and
carriage upto 5 km lead complete (earth measured in stacks will be Cum 120.00 525.84 63100.80
reduced by 20% for payment), 150mm thick.
3 Supplying and stacking sludge at site including royalty and carriage
upto 5 km lead complete (sludge measured in stacks will be reduced Cum 120.00 310.13 37215.36
by 8% for payment).
4 Uprooting weeds from the trenched area after 10 to 15 days of its
flooding with water including disposal of uprooted vegetation,
breaking clods and fine dressing the ground including all materials Sqm 300.00 4.82 1444.80
and labour complete as per direction of Engineer-In-Charge.
5 Providing and laying of soft surface such as grass lawns in
between open spaces as per direction of officer-in-charge.
6 Provision of plantation all around the campus with suitable Plants
and Shurbs where required including all material and labour charge.
7 Providing and Displaying Verbena in different colour having 30 to 45
cm ht., well developed with fresh & healthy foliage in bloom condition
in 25 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-
8 Providing and stacking of Duranta Golden, having ht.15 to 20 cm
bushty shape with fresh and healthy leaves in 15 cm size of Earthen
Pot / Plastic Pot & as per direction of the officer-incharge..
9 Providing and stacking of Calliandra, emarginata of height 45-60 cm.
in earthen pot of size 20 cm as per direction of the officer-in-charge. Nos 20.00 36.96 739.20
10 Providing and stacking of Cassia biflora of height 90-105 cm., well
branched, bushy in big size HDPE bag as per direction of the officer- Nos 25.00 112.00 2800.00
11 Providing and stacking of Dombeya mastersii of height 60-75 cm.
with 4- 5 branches in bag of size 25 cm as per direction of the officer- Nos 20.00 123.20 2464.00
12 Providing and stacking of Thuja compacta of height 75-90 cm.,
conical shaped, well formed with healthy foliage in earthen pots of Nos 20.00 145.60 2912.00
size 30 cm as per direction of the officer-in-charge.
13 Providing and Displaying Foxtail palm well developed with fresh &
healthy foliage of ht. 210 to 240 cm in big 40 cm Cement Pot as per Nos 30.00 1324.96 39748.80
direction of the officer-in-charge.
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
14 Providing and stacking of Polyalthia longifolia (Ashok) of height 180-
195cm. in gunny bag of size 30 cm as per direction of the officer-in- Nos 20.00 112.00 2240.00
15 Providing and stacking of Nauclea cadamba (Kadam) of height 150-
165 cm. in big poly bag of size 25 cm as per direction of the officer-in- Nos 30.00 72.80 2184.00
16 Providing and displaying of Araucaria cookie plant, having ht. 60 cm
to 75 cm, straight, well developed, fresh and healthy with lush green
leaves from bottom to top in 20 cm size of Earthen pot/Plastic pot. &
as per direction of the officer-in-charge.
17 Providing and stacking of Lagerstroemia flosreginae of height 150-
165 cm.in big poly bag of size 25 cm as per direction of the officer-in- Nos 80.00 134.40 10752.00
18 Providing and stacking of Barleria cristata Nos 80.00 336.00 26880.00
19 Providing and stacking of royal plam Nos 76.00 1344.00 102144.00
20 Providing and stacking of cook pine Nos 95.00 672.00 63840.00
21 Providing and stacking of cycas plam Nos 60.00 1008.00 60480.00
22 Providing and stacking of coleus Nos 44.00 67.20 2956.80
23 Providing and stacking of white jasmine Nos 50.00 56.00 2800.00
24 Plantation of Trees, Shrubs, and Hedge at site i/c watering and
removal of unsaverieable material’s as per direction of officer in Nos 335.00 6.94 2326.24
charge (excluding cost of plant & water)
27 Supply and placing in position Pearl Single bed Nos 32.00 28271.04 904673.28
28 Supply and placing in position Chocolate Premium Bedside Table
29 Supply and placing in position Chocolate king Size Double Bed Nos 4.00 77118.72 308474.88
30 Supply and placing in position Mattress - ortho deluxe (78 x72x6)
31 Supply and placing in position Mattress - Ortho-OrthoM Reg Mat 78
32 Supply and placing in position Nice Pillow ,Size ( in cm) : 43 x 69
33 Supply and placing in position Chococlate Study Table Nos 36.00 22442.56 807932.16
34 Supply and placing in position Bravo Visitor Chair,Tubular Frame, PP
35 Supply and placing in position Enterprise table -1500 x 750 x 728
36 Supply and placing in position Motion high back chair for teacher
37 Supply and placing in position Alice centre table Nos 4.00 18693.92 74775.68
38 Supply and placing in position Cantina table with merit red chair Nos 10.00 39810.40 398104.00
39 Supply and placing in position 3 seater sofa PISA Nos 4.00 43972.32 175889.28
40 Supply and placing in position Reception Table Impression 2 arc
Rubber Wood TOP
41 Wardrobe and tv unit work
42 Supplying,Providing,fitting fixing of wall paneling to the wall with
19mm BWR block board .1mm larninate ,teak wood lipping in the
areas required as per details design and specifications and including Sqmt 100.80 2979.78 300361.84
cost of fixing of the soft board,fabric ,labour etc.compete as per the
detail design .(Tv unit area)
Supplying ,providing ,fitting ,fixing of wardrobe (portable &
detachable) with 19mm BWR grade block board and 12mm thick
BWR ply at the back side and finished with 1mm laminates,finished Sqmt 168.00 1131.04 190015.26
the wooden lipping with French polish & internal surface finished with
0.80mm thick laminate with all necessary hardware as per design
.(wardrobe area with dresser)
Providing all materials, labour, T&P for fitting and fixing white glazed
vitreous china water closet (European pattern) with seat cover
(solid) and Cistern of approved make in all floor including supply of
1 sutaible bracket, PVC wall plug and Brass screws etc. all complete NOS 41.00 9129.12 374293.92
including cost, taxes and conveyance as per specification all
complete as per direction of Engineer-in-charge.
Make:HINDWARE/PARRYWARE/CERA.
(As per Cat no.20065 of Hindware)
Supply all materials and labour for fitting and fixing of following size
white glazed vitreous china Under counter wash hand basin of
approved make in all floor of approved quality including cutting the
walls & floor and making good the damages with cement concrete
2 etc. including all taxes, duties, transportation etc. all complete as per NOS 4.00 7382.48 29529.92
direction of EIC.
(Make:HINDWARE) (As per Cat no.
10049 of Hindware)
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
Supply all materials and labour for fitting and fixing of following size
white glazed vitreous china wash hand basin of approved make
in all floor of approved quality including cutting the walls & floor and
making good the damages with cement concrete etc. including all
3 taxes, duties, transportation etc. all complete as per direction of EIC. NOS 39.00 6926.86 270147.70
(Make:HINDWARE/PARRYWARE/CERA)
(As per Cat no. 10051 of Hindware)
Longbody One-way Bib cock with wall Flange.
(As per Cat no.F330011 of Hindware)
Two-way Bibcock with wall Flange.
(As per Cat no.F730004 of Hindware)
15mm dia Mixer Pillar Cock
(As per Hindware Cat No-F740002 )
Health Faucet ABS SS braided hose 1.00m with CP hook.
(As per Cat no.F160068 of Hindware)
15mm dia Angle Stop cock with Wall Flange.
(As per Cat no.F200005 of Hindware)
Providing and fixing Parryware Cat no-C862499 (60 x 45 cm)
beveled edge mirror of superior glass 4mm thick(of approved quality)
complete with 6 mm thick hard board ground fixed to wooden cleats
with C.P. brass screws and washers complete.
Providing and fixing 600x120x5 mm glass shelf with edges round off,
supported on anodised aluminium angle frame with C.P. brass
(h) brackets and guard rail complete fixed with 40 mm long screws, rawl NOS 41.00 1379.39 56555.07
plugs etc., complete. Hindware(cat no-F870011)
C.P. Soap Dish holder.
(As per Cat no.F890002 of Hindware)
Waste Coupling 32mm (Half Threaded)
(As per Cat no.ALD-CHR-709L130 of Jaquar)
32mm dia C.P. Waste 130 mm ht. (Full Threaded)
( As per Cat no.ALD-CHR-705L130 of Jaquar)
Towel Rail 600 mm long .
(As per Cat no.F450024 of Hindware)
Towel Ring with round Flange.
(As per Cat no.Hindware of Cat no:F880007)
Supplying all materials, labour, T&P and fixing Paper Holder having
(o) Cat No- F84008 Hindware make. complete as per specification and NOS 11.00 1501.58 16517.42
direction of the Engineer in charge
Overhead shower 120 mm Round shape Multi Flow (ABS Body)
chrome plated with Gray Face Plate)with Rubit Cleaning System &
Shower Arm casted 190 mm long Flat shape for wall mounted
Showers with Flange. .
Wall mixture with provision for Overhead shower with 115mm Long
bend pipe Shower Arrangement.
Providing and fixing Jaquar 20 L Storage Water Geyser(White,
Black, Jaquar Alexa).
Providing and fixing Stainless Steel kitchen sink (Parryware, Cat no.-
C852399 with C.I. brackets and stainless steel plug 40 mm, including
painting of fittings and brackets, cutting and making good the walls
wherever required :
Providing 15 mm dia Sink cock of Hindware having cat no -
9 F120021 , including painting of fittings and brackets, cutting and NOS 2.00 2161.04 4322.08
making good the walls wherever required :
100x100 mm dia stainless steel grating (As
per Cat no. FT-77 square of Prayag)
Providing all materials, labour, T&P for laying/fixing of following dia
CPVC pipes SDR-11 as per IS-15778/2007 with ISI mark including
fixing of required size CPVC fittings like bend, Tee, elbow, offsets
etc. and the same fixed on wall or floor with holder bat clamps screw
11 in all floor or laying in trenches including excavation of earth work in
all kinds of soil & backfilling the trenches as per specification &
testing the joints with required water presure.The cost inclusive of all
taxes,duties,transportation scaffolding etc. as per specification and
direction of Engineer-in-charge.
Make:Supreme/ASHRIVAD/AJAY.
Providing, laying and jointing PVC SWR soil, waste and vent pipes
under floor /suspended under ceiling / fixed on the wall face
12 conforming to IS:15905-2011 , ISO-6594. Includes making
connection with sanitary fittings, and testing of pipelines, etc. all
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
Providing and fixing gun metal ball valve with C.I. wheel of approved
quality (screwed end) :
a) 25mm dia ball valve No. 45.00 580.05 26102.16
b) 32mm dia ball valve No. 10.00 1172.86 11728.64
c) 40mm dia ball valve No. 4.00 1541.79 6167.17
d) 50mm dia ball valve No. 6.00 2519.33 15115.97
Providing all materials labour, T&P for making grooves in
bricks/stone masonary walls vertically or horizontally up to required
depth and width in all floor for laying of pipes and fittings up to
50mm dia, testing the joints with required water pressure and
14 making good the damages with cement concrete 1:2:4 with 12mm Mtr. 400.00 175.17 70067.20
size h.g.c.b.chips and finished smooth with cement morter (1:4) to
original shape including cost of materials, curing, conveyance, taxes
of all materials etc. all complete as per specification & direction of
Providing all labour,T&P for cutting holes in bricks or stone masonry
wall for taking pipes in all floors and making good the damages with
cement concrete 1:2:4 finished smooth with CP 1:4 to original
shape including cost of all materials, curing, conveyance, taxes,
duties etc. all complete as per specification & direction of Engineer-
Providing all labour,T&P and cutting holes in RCC chajja/roof/floor
for taking pipes through and making good the damages with supply
of all required materials etc. complete as per the direction of the
Engineer-in-charge.
Providing, laying and jointing Cpvc SWR soil, waste and vent pipes
under floor /suspended under ceiling / fixed on the wall face
conforming to IS:15778-2007 , ISO-6594 Includes necessary fittings
like (plain or door)tees, bends, collars, crosses reducers, Y, etc, of
approved make, drip seal joint, suspended under ceiling / embedded
in floor. Includes making connection with sanitary fittings,of
approved make etc all complete . (As per Supreme etc)
e) 110mm dia 'T' juncion Nos. 20.00 291.20 5824.00
g) 100mm Single Branch Door Tee Nos. 12.00 689.92 8279.04
h) 100 mm Single Branch Plain "Y" 45 D Nos. 25.00 674.24 16856.00
i) 75 mm Single Branch Plain "Y" 45 D Nos. 16.00 617.12 9873.92
j) 100mm Double Branch Plain 'Y' 45D Nos. 25.00 679.84 16996.00
k) 100mm Single Branch Door 'Y' 45D Nos. 30.00 702.24 21067.20
l) 100 mm Shielded (SS - 304) Coupling Nos. 8.00 542.08 4336.64
m) 75 mm Shielded (SS - 304) Coupling Nos. 18.00 500.64 9011.52
n) 100 mm WC Connector 350 mm long with EPDM Rubber. Nos. 5.00 453.60 2268.00
s) 100 mm Pipe Wall Clamp Nos. 200.00 580.16 116032.00
Providing, laying trench pipe and jointing PVC SWR TYPE-B pipes
and fittings etc complet.
Providing, laying, jointing, testing, & commissioning of non-pressure
NP3 Class RCC Pipes with collars jointed with stiff mixture of
cement mortar in the proportion of 1:2 (1 cement : 2 find sand)
including testing of joints etc. complete
EXTERNAL WATER SUPPLY
A) Earth work in ordinary soil with initial lead and lift including rough
dressing in layers not exceeding 0.3m in depth and the Earth
transported by transport vehicles as directed by the Engineer-in-
Filling available excavated earth (excluding rock) in trenches, plinth,
sides of foundations etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead
up to 50 m and lift upto 1.5 m.
Supplying all labour, T&P for the Carriage of excavated earth by
mechanical means of transport within 5.00 K.M. lead including hire
3 and running charges of vehicles, labour charges for loading and CUM 5.45 224.22 1222.78
unloading as required for the work etc. complete as per the direction
of the Engineer-in-charge.
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
Providing and fixing to wall or celling and floor rigid UPVC pipes
class IV (8 kgf/cm2) class II (6kgf/cm2) conforming to IS: 4985/2000
AND Pipe fittings of the following nominal bore with clamp including
making good the wall,ceilling and floor all complete as per
specification and direction of Engineer-in-charge.
Make:Supreme/ASHRIVAD/AJAY.
i) 50mm dia (UGR to OHT tank) RM 80.00 1018.19 81455.36
ii) 50mm dia (Borewell Pipe) RM 45.00 1018.19 45818.64
Providing & fixing of Cast iron,Double flanged swing type non return
5 valve IS-5312, of approved make with high tensile bress rising stem
suitable for the system pressure as per IS 780
Supplying all materials, labour, T&P, fitting & fixing of different size
bourden type pressure gauge of reputed make (0-10 kg/sqcm) with
valves, piping, fitting of approved make including supply of all
6 necessary jointing materials such as red lead paint, yarns etc.
including cost, conveyance & taxes of all materials, T&P etc. all
complete as per P.H. specification and as per the direction of the
Engineer-in-charge. (MR)
Providing and fixing C.I. double acting air valve of approved quality
with bolts, nuts, rubber insertions etc. complete (The tail pieces,
tapers etc if required will be paid separately) :
Pump for OHT Tank Filling (Hostel Building)
Supply installation, Testing & Commissioning of Horizontal Multi
Stage Monoblock Centrifugal pumps with CI with CED Coated
Suction & Discharge Casing, SS 304- Impellers, SS 304-Shaft, SS
304-Intermediate Casing. Pump shoule come with 380-415V, 50Hz,
2 Pole, IP 55 Enclosure Class, Class F insulated 1.5 KW (2 HP)
Pump controller suitable for 2 Pumps (1W+1S) with LCD screen
displays, phase loss protection (incoiming as well as for outgoing),
Individual pump overload protection, individual pump under voltage
protection, dryrunning protection without installing any float switch,
memory function when power off and during recovery, visual and
audio alarm for fault prompt, auto manual switch and pump should
operate based on the sump water level and both pump should run
together for high level. Panel should come with 3 Nos Float switch to
work as per the OHT water level. (Make-grundfos,kirloskar,luby or
Per Pump Flow Rate-8 M3/hr (1W+1S)
Ball Float (Mechanical)
Supply, Installation & commissioning of reputed make mechanically
operated ball float with Brass Arm for each tank for closing &
opening the inlet of each tank as per the water level in each tank
suitable for handling 10 Bar pressure
10 2000ltr (Drinking Water) Nos. 2.00 24099.26 48198.53
Construction of 1 nos production well including scientific source
finding through consolidated and unconsolidated rock with down the
ODEX drilling rig with PVC, GI, MS pipe and installation of
submersible pump set with all accessories.
Labour for drilling a perfectly vertical bore hole of specified dia for a
specified depth below ground level through consolidated and
unconsolidated rock with combination drilling rig as required to suit
the site condition as per the direction of Engineer-in-charge including
supply of own rig with its accessories, tools and plant and
consumables etc. for lowering of 200mm /150mm dia M.S. Pipe /
PVC casing fitted with socket and with or without well screen as per
1 the necessity for sub-medium hard and boulder formation (M.S./PVC
casing pipe if required to prevent collapse of over burden is to be
provided by contractor including lowering and withdrawing after
completion of the tube well) 200mm dia x 400mm dia in over burden
position inlcluding packing of gravel supplied by Contractor for
400mm bore only etc as per direction of Engineer incharge.
Drilling for 200mm dia bore
Drilling for 150mm dia bore
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
Lowering the following size of G.I. / PVC / M.S. housing pipe with or
without slotted pipe as per the necessity for ground level upto 45 mtr
depth and fitted and fixed up perfectly vertical position including
cutting and threading of pipes and slotted pipes and supplying and
fixing all jointing materials, tools and plants etc all complete and
keeping the top of the casing pipe threaded including plugging tube
wells to prevent entry of foreign materials.
Lowering 200mm dia M.S.ERW pipe casing pipe
cleaning and developing the tube well with supply of compressor
worked till clear and adequate discharge in obtained from the tube
well including supply and use of all necessary equipment and labour
as per direction of Engineer-in-charge.
Supplying all labour, materials and T&P for providing sanitary sealing
by cement concrete grouting of annular space around M.S. casing
4 pipe uptp 5 mtr below groun dlevel to plug the bore hole excluding No. 1.00 1805.40 1805.40
cost of cement etc all complete as per direction of EIC.
Borewell Submersible Pump (Hostel Building)
Supply, installation & commissioning of submersible borewell pump
(4 Inch Dia). Pump should be with all SS 304 ( (Pump casing,
Impellers, Shaft all other parts)) material of construction (Caste Iron
Pumps are not acceptable) with 380-415V, 50 Hz 2 Pole. 1.5 KW (2
HP) high efficiency class motor. Pump hydraulic efficiency should not
be less than 65%.
Pump controller suitable for 1 Pump with LCD screen displays,
phase loss protection (incoiming as well as for outgoing), Individual
pump overload protection, individual pump under voltage protection,
dryrunning protection without installing any float switch, memory
function when power off and during recovery, visual and audio alarm
for fault prompt, auto manual switch and pump should operate based
on the UGT water level . Panel should come with 1 Nos Float switch.
Flow Rate- 9 m3/hr
DOL control panel Each 2.00 4262.16 8524.32
40mm steel short piece Each 2.00 170.58 341.15
well cap Each 2.00 170.58 341.15
50mm size CI bracket Each 2.00 102.26 204.51
2.50 sqmm flat cable Mtr 200.00 143.47 28694.40
steel rope with cover Mtr 200.00 29.90 5980.80
labour charges for lowering including transportation No. 2.00 2240.00 4480.00
Supplying all materials, labour, T&P and providing and fixing to wall
or ceiling and floor IS marked galvanised mild steel tubes (medium
grade) confirming to IS: 1239/1990, part-1 of the following nominal
bore, tube fittings and clamps including making good the wall ,
ceiling and floor, testing, cost & conveyance of all materials to
worksite, payment of all taxes etc all complete as per P.H
specification and direction of the Engineer-in-charge.
32mm dia G.I. pipe Mtrs. 90.00 432.32 38908.80
Providing, laying and jointing Rainwater PVC pipes and fittings along
with fixing to wall etc complet as per IS no-15905 .
a) (i) 110 mm diameter in Mtr 80.00 560.45 44835.84
DETAIL ESTIMATE OF SEWERAGE PIPE LINE TRENCH
Earth work in excavation by mechanical means (Hydraulic excavator)
/ manual means in foundation trenches or drains (not exceeding 1.5
m in width or 10 sqm on plan), including dressing of sides and
ramming of bottoms, lift upto 1.5 m, including getting out the
excavated soil and disposal of surplus excavated soil as directed,
within a lead of 50 m.
Providing and laying in position cement concrete of specified grade
2 excluding the cost of centering and shuttering - All work up to plinth
1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm
Supplying and filling sand in foundation and over areas including
watering, ramming, consolidating and dressing, labours, tools, taxes
etc. all complete as per the specification and direction of Engineer-In-
Supplying and filling in for CC lining 75 mm all arround on PVC pipes
4 and base along with Jamuna sand under floors, including watering, cum 8.52 839.22 7148.48
ramming, consolidating and dressing complete.
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
Supplying all materials, labour, T&P and construction man hole
chamber of the following size with cement concrete(1:3:6) using
40mm size hard granite metal on bed, 1st class Fly ash brickwork in
cement mortar(1:6), moulding and shaping the channel inside and
benching with cement concrete (1:2:4) using 12mm size h.g
chips,12mmthick cement plaster (1:3) with punning to inside, cement
5 flush pointing (1:3) to outside, R.C.C cover slab in (1:1½:3) using
12mm size h.g chips with RCPC man hole cover, earthwork in
excavation in all kinds of soil and refilling the cavity around the
chamber including watering, curing, conveyance of all materials to
worksite, payment of royalty, taxes etc all complete as per approved
specification and direction of the Engineer in charge
Inside size 910mm x 910mm x 910mm NOS 20.00 16533.44 330668.80
Earth work in excavation by mechanical means (Hydraulic excavator)
/ manual means in foundation trenches or drains (not exceeding 1.5
m in width or 10 sqm on plan), including dressing of sides and
ramming of bottoms, lift upto 1.5 m, including getting out the
excavated soil and disposal of surplus excavated soil as directed,
within a lead of 50 m.
Supplying and filling in plinth with sand under floors, including
watering, ramming, consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade
3 excluding the cost of centering and shuttering - All work up to plinth
1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm
Brick work with common burnt clay F.P.S. (non modular) bricks of
class designation 7.5 in foundation and plinth in
Cement mortar 1:6 (1 cement : 6 coarse sand) cum 0.80 5238.52 4164.62
Providing and laying in position ready mixed M-25 grade concrete for
reinforced cement concrete work, using cement content as per
approved design mix, manufactured in fully automatic batching plant
and transported to site of work in transit mixer for all leads, having
continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work, including
pumping of R.M.C. from transit mixer to site of laying , excluding the
5 cost of centering, shuttering finishing and reinforcement, including 1897.93
cost of admixtures in recommended proportions as per IS : 9103 to
accelerate/ retard setting of concrete, improve workability without
impairing strength and durability as per direction of the Engineer - in -
(Note :- Cement content considered in this item is @ 330 kg/cum.
Excess/less cement used as per design mix is payable/recoverable
Steel reinforcement for R.C.C. work including straightening, cutting,
6 bending, placing in position and binding all complete upto plinth qtl 0.12 8553.56 1052.09
well sink with top and bottom cover of min 50 mm thk with
cementing Khoa filling etc
Earth work in excavation by mechanical means (Hydraulic excavator)
/ manual means in foundation trenches or drains (not exceeding 1.5
m in width or 10 sqm on plan), including dressing of sides and
ramming of bottoms, lift upto 1.5 m, including getting out the
excavated soil and disposal of surplus excavated soil as directed,
within a lead of 50 m.
B) From 1.5M to 3.0M Depth CUM 9.80 309.75 3035.14
Filling at all depth with available excavated earth (excluding rock) in
trenches, plinth, sides of foundations etc. in layers not exceeding
2 15cm in depth: consolidating each deposited layer by ramming and CUM 28.78 116.03 3339.38
watering complete (lead upto 100m) as directed by the Engineer-In-
Supplying and filling sand in foundation and over areas including
watering, ramming, consolidating and dressing, labours, tools, taxes
etc. all complete as per the specification and direction of Engineer-In-
Providing and laying plain cement concrete 1:4:8 (1 cement : 4 sand
: 8 stone agregate 40mm nominal size) as levelling course in floor
and plinth including tempering, curring, shuttering etc. complete all
depth and height.
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
Providing and laying in position ready mixed M-25 grade concrete for
reinforced cement concrete work, using cement content as per
approved design mix, manufactured in fully automatic batching plant
and transported to site of work in transit mixer for all leads, having
continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work, including
pumping of R.M.C. from transit mixer to site of laying , excluding the
5 cost of centering, shuttering finishing and reinforcement, including
cost of admixtures in recommended proportions as per IS : 9103 to
accelerate/ retard setting of concrete, improve workability without
impairing strength and durability as per direction of the Engineer - in -
(Note :- Cement content considered in this item is @ 330 kg/cum.
Excess/less cement used as per design mix is payable/recoverable
Cutting, straightening coiled or bent up M.S. Rod or tor steel of SAIL/
TATA / RINL (VIZAG) make including bending, binding, welding and
joining if necessary and tying the grills and placing in position as
required for R.C.C. Work and for providing fan hooks as required,
hoisting, lowering, laying including cost, conveyances, taxes of M.S.
Rod or tor steel and binding wires of 18 to 20 gauge and labour
6 required for the work for bending, binding and tying the grills in all QTL 10.66 9478.67 101066.86
floors (Linear measurement will be taken and quantity will be
calculated basing on the standard weight of B.I.S. for M.S. Rods or
tor steel only. Wastage if any, including weight of binding wire will not
be considered for measurement) etc. complete as per specification &
direction of Engineer-in-charge.
12mm cement plaster to out side of brick surfaces with cement
7 mortar of mix 1:4 (1 cement : 4 fine sand) including necessary
scaffolding, curing etc. all complete at all floors and all heights.
1:4 (1 cement: 4 fine sand) SQM 43.49 176.29 7666.32
8 Neat cement punning. SQM 43.49 25.98 1129.98
2.5 cm thick A.S Flooring in C.C (1:2:4) including punning using 12
9 mm size C.B hard granite chips with cost of all labour & other CUM 20.00 321.44 6427.19
materials etc complete.
ABSTRACT DETAIL ESTIMATE OF CIVIL WORKS OF UGR TANK
Earth work in excavation by mechanical means (Hydraulic excavator)
/ manual means in foundation trenches or drains (not exceeding 1.5
m in width or 10 sqm on plan), including dressing of sides and
ramming of bottoms, lift upto 1.5 m, including getting out the
excavated soil and disposal of surplus excavated soil as directed,
within a lead of 50 m.
B) From 1.5M to 3.0M Depth CUM 14.88 309.75 4608.11
Filling at all depth with available excavated earth (excluding rock) in
trenches, plinth, sides of foundations etc. in layers not exceeding
2 15cm in depth: consolidating each deposited layer by ramming and CUM 22.43 116.03 2602.26
watering complete (lead upto 100m) as directed by the Engineer-In-
Supplying and filling sand in foundation and over areas including
watering, ramming, consolidating and dressing, labours, tools, taxes
etc. all complete as per the specification and direction of Engineer-In-
Providing and laying plain cement concrete 1:4:8 (1 cement : 4 sand
: 8 stone agregate 40mm nominal size) as levelling course in floor
and plinth including tempering, curring, shuttering etc. complete all
depth and height.
Providing and laying in position ready mixed M-25 grade concrete for
reinforced cement concrete work, using cement content as per
approved design mix, manufactured in fully automatic batching plant
and transported to site of work in transit mixer for all leads, having
continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work, including
pumping of R.M.C. from transit mixer to site of laying , excluding the
5 cost of centering, shuttering finishing and reinforcement, including
cost of admixtures in recommended proportions as per IS : 9103 to
accelerate/ retard setting of concrete, improve workability without
impairing strength and durability as per direction of the Engineer - in -
(Note :- Cement content considered in this item is @ 330 kg/cum.
Excess/less cement used as per design mix is payable/recoverable
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
Cutting, straightening coiled or bent up M.S. Rod or tor steel of SAIL/
TATA / RINL (VIZAG) make including bending, binding, welding and
joining if necessary and tying the grills and placing in position as
required for R.C.C. Work and for providing fan hooks as required,
hoisting, lowering, laying including cost, conveyances, taxes of M.S.
Rod or tor steel and binding wires of 18 to 20 gauge and labour
6 required for the work for bending, binding and tying the grills in all QTL 6.90 9478.67 65402.84
floors (Linear measurement will be taken and quantity will be
calculated basing on the standard weight of B.I.S. for M.S. Rods or
tor steel only. Wastage if any, including weight of binding wire will not
be considered for measurement) etc. complete as per specification &
direction of Engineer-in-charge.
12mm cement plaster to out side of brick surfaces with cement
7 mortar of mix 1:4 (1 cement : 4 fine sand) including necessary SQM 26.70 176.29 4706.89
scaffolding, curing etc. all complete at all floors and all heights.
8 Neat cement punning. SQM 26.70 25.98 693.77
Supplying and fixing 900mm dia SFRC cover without frame for
9 manhole including cost of all materials, T&P, labour etc complete as NOS 2.00 3225.60 6451.20
per direction of Engineer-in-charge.
2.5 cm thick A.S Flooring in C.C (1:2:4) including punning using 12
10 mm size C.B hard granite chips with cost of all labour & other CUM 4.50 321.44 1446.48
materials etc complete.
DETAILED ESTIMATE FOR CIVIL WORKS OF FIRE PUMP
Brick work with non modular fly ash lime bricks (FALG Bricks)
conforming to IS:12894, class designation 10 average compressive
strength in super structure above plinth level up to floor V level in
:Cement mortar 1:6 (1 cement : 6 Coarse sand)
Providing and laying in position ready mixed M-25 grade concrete for
reinforced cement concrete work, using cement content as per
approved design mix, manufactured in fully automatic batching plant
and transported to site of work in transit mixer for all leads, having
continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work, including
pumping of R.M.C. from transit mixer to site of laying , excluding the
2 cost of centering, shuttering finishing and reinforcement, including
cost of admixtures in recommended proportions as per IS : 9103 to
accelerate/ retard setting of concrete, improve workability without
impairing strength and durability as per direction of the Engineer - in -
(Note :- Cement content considered in this item is @ 330 kg/cum.
Excess/less cement used as per design mix is payable/recoverable
Supplying, fitting and placing uncoated HYSD bar reinforcement
3 complete as per drawing and technical specifications in Ground Floor QTL 0.50 9478.67 4779.15
4 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) SQM 29.58 152.10 4499.00
5 6 mm cement plaster of mix :1:4 (1 cement : 4 fine sand) SQM 2.94 170.35 500.83
Providing and fixing 1mm thick M.S. sheet door with frame of
40x40x6 mm angle iron and 3 mm M.S. gusset plates at the
junctions and corners, all necessary fittings complete, including
applying a priming coat of approved steel primer.
Using flats 30x6mm for diagonal braces and central cross
Providing and fixing M.S. grills of required pattern in frames of
7 windows etc. with M.S. flats, square or round bars etc. including
priming coat with approved steel primer all complete.
Fixed to steel windows by welding KG 43.20 69.66 3009.48
Painting two coats with approved Enamel Paint on Iron work over a
Applying one coat of water thinnable cement primer of approved
brand and manufacture on wall surface :
Finishing walls with water proofing cement paint of required shade :
New work (Two or more coats applied @ 3.84 kg/10 sqm) sqm 112.74 36.40 4103.74
ABSTRACT ESTIMATE FOR CONSTRUCTION OF DRAINAGE
Earthwork in excavation in all types of soil for site leveling, Drain
and other civil works upto 1.5 metre and stacking the soil including
1 dewatering, removing slush,shoring and strutting (as required), Cum 114.00 208.77 23799.55
complete as per specification and as per the directed of the
Engineer-In-Charge.
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
Filling at all depth with available excavated earth (excluding rock) in
Drain sides in layers not exceeding 12 cm in depth: consolidating
each deposited layer by ramming and watering complete all as per
the directed of the Engineer-In-charge.
Supplying & filling of approved river sand in Drain and over areas
including watering,ramming, consolidating and dressing, labours,
tools, taxes etc. all complete as per the specification and direction of
Engineer-In-charge.
Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand :
8 stone agregate 40mm nominal size) as levelling course in Drain
4 etc. including tempering, curring, shuttering etc. complete all depth Cum 22.80 4593.90 104741.01
and height as per the direction of Engineer-In-charge.
Providing, lifting, hoisting and laying Reinforced cement concrete of
M-250 grade as per approved designs and drawings having a
minimum compressive strength (in work test) 250 Kg. / Square cm.
in 15 cm. cubes at 28 days after mixing and test conducted in
accordance with I.S. 516 using 12 mm. to 20 mm. size black hard
crushed broken granite stone chips and screened and washed sharp
sand for mortar of approved quality from approved quarry, washed
and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed
in concrete mixture with Portland slag cement (PSC) including
hoisting, lowering, laying and compaction concrete by using
5 vibrators, watering and curing for 28 days, centering and shuttering
then after dismantling and removing debris from the work site and
finishing the exposed surface smooth providing grooves or beads
wherever necessary including cost, conveyance, loading, unloading,
royalties and taxes of all materials and cost of all labours, sundries,
T & P required of the work etc. complete in all respect as directed by
the Engineer-in-Charge. But excluding cost and conveyance of M.S.
rods or Tor steel and binding wires and labour charges for
straightening, cutting, bending etc. of M.S. rods or tor steel tying the
grills and placing in proper position.
Drain Bottom slab Cum 18.00 5818.06 104725.15
Supplying, straightening, cutting, bending, placing in position and
binding reinforcement steel work in RCC/Reinforced brick works as
per drawing and specification including preparation of respective bar
6 bending schedule and binding (Binding wire to be used as per the IS Qntl 43.68 9478.67 414028.39
code) etc. all complete as per direction of Engineer-In-Charge. Cold
Twisted bars, Thermo-Mechanically-treated bars.
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
ELECTRICAL WORK
A Sub-Head I (modular Wiring Items)
1 Recessed wirring to light point/ fan point/ exhaust fan point/ call bell
point with 1.5 sq.mm FRLSH/LSZH PVC insulated copper conductor
of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR
KABLE/KEI or equievalant reputed make A catagory ISI marked
as approved with 20 mm dia PVC flexible non metallic conduit FRLS
type ISI marked Make-AKG/Anchor/Havells or equievalant
reputed make A catagory ISI marked as approved 6A modular
type ( falme retradant type) switch ISI marked Make-
Schneider(Zencelo)/legrand( Arteor) /Panasonic (vision) or
equievalant reputed make & model A catagory ISI marked as
approved, and ceiling rose ISI marked Make- Anchor/Havells of
modular type G.I box with metallic cover plate (both side) ( falme
retradant type) Make-Schneider(Zencelo)/legrand( Arteor)
/Panasonic (vision)or equievalant reputed make & model A
catagory ISI marked as approved of suitable size, modular box
with 1.5 sq. Mm FRLSH PVC insulated single core multistandard
copper conductor as earth wire including all accessories and
connection as per direction of Engineer -in -Charge. CATAGORY AS
FOLLOWS ,complete suitable for OFFICE. All the switches &
sockets should be warrantied for a replacement period of 10
years against defects with ncessary test report & Warrnaty
certificate to be submitted to the department for genuinity of
product & to avail free after sales service within warranty period
for acceptance of materials.
b) Group control of point in Recessed wirring to light point/ fan point/
exhaust fan point/ call bell point with 1.5 sq.mm FRLSH/LSZH PVC
insulated copper conductor of ISI marked
Make- Make- Finolex/Anchor/Polycab/HAVELLS or equievalant
reputed make A catagory ISI marked as approved as approved
20 mm dia PVC flexible non metallic conduit FRLS type ISI marked
Make-AKG/Anchor/Kinjal or equievalant reputed make A
catagory ISI marked as approved with 6A modular type(( falme
retradant type)) switch ISI marked Make-
Schneider(Zencelo)/legrand( Arteor) /Panasonic (vision) or
equievalant reputed make & model A catagory ISI marked as
approved, and ceiling rose ISI marked Make-
Schneider(Zencelo)/legrand( myrius) /Panasonic (Equievalant
model) or equievalant reputed make & model A catagory ISI Nos 30.00 1112.16 33364.80
marked as approved of modular type G.I box with metallic cover
plate (both side) falme retradant type) Make-
Schneider(Zencelo)/legrand( Arteor) /Panasonic (vision)or
equievalant reputed make & model A catagory ISI marked as
approved, of suitable size, modular box with 1.5 sq. Mm FRLS
PVC insulated single core multistandard copper conductor as earth
wire including all accessories and connection as per direction of
Engineer -in -Charge. CATAGORY AS FOLLOWS ,complete
suitable for OFFICE.(Maximum 02 nos point in one circuit).All
the switches & sockets should be warrantied for a replacement
period of 10 years against defects with ncessary test report &
Warrnaty certificate to be submitted to the department for
genuinity of product & to avail free after sales service within
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
c) Group control of point in existing false ceiling wirring to light point/
fan point/ exhaust fan point/ call bell point with 1.5 sq.mm
FRLSH/LSZH PVC insulated copper conductor of ISI marked
Make- Make- Finolex/Anchor/Polycab/HAVELLS or equievalant
reputed make A catagory ISI marked as approved as approved
with 20 mm dia steel conduit ISI mark metallic conduit ISI
marked Make-AKG/Anchor/Kinjal or equievalant reputed make A
catagory ISI marked as approved with 6A modular type( falme
retradant type)) switch ISI marked Make-
Schneider(Zencelo)/legrand( Arteor) /Panasonic (vision) or
equievalant reputed make & model A catagory ISI marked as
approved, and ceiling rose ISI marked Make-
Schneider(Zencelo)/legrand( myrius) /Panasonic (Equievalant
model) or equievalant reputed make & model A catagory ISI Nos 40.00 636.16 25446.40
marked as approved of modular type G.I box with metallic cover
plate (both side)( falme retradant type) Make-
Schneider(Zencelo)/legrand( Arteor) /Panasonic (vision) or
equievalant reputed make & model A catagory ISI marked as
approved, of suitable size, modular box with 1.5 sq. Mm FRLS
PVC insulated single core multistandard copper conductor as earth
wire including all accessories and connection as per direction of
Engineer -in -Charge. CATAGORY AS FOLLOWS ,complete
suitable for STADIUM.(Maximum 02 nos point in one circuit).All
the switches & sockets should be warrantied for a replacement
period of 10 years against defects with ncessary test report &
Warrnaty certificate to be submitted to the department for
genuinity of product & to avail free aftersales service within
d) Supplying ,fixing of 6A Plug on the same board in existing switch
board with complete fitting by 01 no of 6A switch & socket (modular
type)( ( falme retradant type)) & other required accessories of ISI
marked as approved as per direction of Engg. -in -Charge. Make-
Schneider(Zencelo)/legrand( Arteor) /Panasonic (vision) or
equievalant reputed make & model A catagory ISI marked as
approved, complete suitable for for HOSTEL.(Maximum 02 nos
point in one circuit).All the switches & sockets should be
warrantied for a replacement period of 10 years against defects
with ncessary test report & Warrnaty certificate to be submitted
to the department for genuinity of product & to avail free
aftersales service within warranty period for acceptance of
e) Supplying,fixing of 6A Plug on the separate board with complete
fitting by 01 no of 6A switch & socket(modular type)( ( falme
retradant type)) with suitable size modular box & cover( falme
retradant type) including supplying of all required accessories of ISI
marked as approved as per direction of engg-in-charge..Make-
Schneider(Zencelo)/legrand( Arteor) /Panasonic (vision) or
equievalant make & model ISI marked as approved , complete
suitable for OFFICE.(Maximum 02 nos point in one circuit).All Nos 110.00 561.12 61723.20
the switches & sockets should be warrantied for a period of 10
years against manufacturing defects against which ncessary
test report & Warrnaty certificate to be submitted to the
department for genuinity of product & to avail free aftersales
service within warranty period for acceptance of materials.
f) Supplying,fixing of 1x16A Plug on the separate board with complete
fitting by 01 no of 16A switch & socket(modular type)( falme
retradant type)) with suitable size modular box & cover( falme
retradant type) including supplying of all required accessories of ISI
marked as approved as per direction of engg-in-charge.. Make-
Schneider(Zencelo)/legrand( Arteor) /Panasonic (vision)or
equievalant reputed make A catagory ISI marked as approved,
(For equipement power)All the switches & sockets should be
warrantied for a replacement period of 10 years against defects
with ncessary test report & Warrnaty certificate to be submitted
to the department for genuinity of product & to avail free
aftersales service within warranty period for acceptance of
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
g) Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with
complete fitting by 01 no of 16A+1 no 6A switch & socket(modular
type) ( ( falme retradant type) with suitable size modular box &
metallic cover plate (both side)( falme retradant type)including
supplying of all required accessories of ISI marked as approved as
per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand(
Arteor) /Panasonic (vision)or equievalant reputed make & model
A catagory ISI marked as approved, (For equipement
power)complete suitable for for OFFICE.(Maximum 02 nos point
in one circuit).All the switches & sockets should be warrantied
for a replacement period of 10 years against defects with
ncessary test report & Warrnaty certificate to be submitted to
the department for genuinity of product & to avail free aftersales
service within warranty period for acceptance of materials.
2 Receass wiring for circuit/submain wiring with the following
mentioned size PVC FRLSH/LSZH insulated, copper conductor,
single core cable (Finolex/Anchor/Polycab/ HAVELLS/RR
KEBLE) or equievalant reputed make A catagory ISI marked as
approved, in recessed PVC conduit Heavy duty FRLS of
mentioned size (AKG/Anchor/Kinjal or equievalant ISI marked as 0.00 0.00
approved) as required as per direction of Engg.-in-Charge. Ncessary
test report & Warrnaty certificate to be submitted to the department
for genuinity of product & to avail free after sales service within
warranty period for acceptance of materials
a) 2 nos single core 1.5 sq. mm copper wire for phase and neutral
and 01 no of single core 1.5 sq. mm copper wire for earth continuty
conductor. In 20 mm dia non metallic heavy duty flexible conduit
(LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)
b) 2 nos single core 2.5 sq. mm copper wire for phase and neutral
and 01 no of single core 1.5 sq. mm copper wire for earth continuty
conductor in 20 mm dia non metallic heavy duty flexible Mtr 588.00 157.92 92856.96
conduit.(BDB to LSB/LIGHT CKT/5A PLUG/INVERTER POINT TO
EACH QTR) (2X2.5+1X1.5)
c) 4 nos single core 2.5 sq. mm copper wire for phase and neutral
and 02 nos of single core 2.5 sq. mm copper wire for earth continuty
conductor .in 25 mm dia non metallic heavy duty flexible
conduit(LDB to LSB/5A SOCKET) (4X2.5+2X2.5)
d) 2 nos single core 4 sq. mm copper wire for phase and neutral
and 01 no of single core 1.5 sq. mm copper wire for earth continuty
conductor in 20 mm dia non metallic heavy duty flexible conduit
.(PDB to PSB/ GAYSER POINT/AC POINT/ROOM LIGHT
CONTROL TO CORRIDOOR POINT/DG PANEL ESSENTIAL
LOAD) (2X4+1X1.5)
e) 4 nos single core 4 sq. mm copper wire for phase and neutral
and 02 nos of single core 2.5 sq. mm copper wire for earth continuty
conductor in 32 mm dia non metallic heavy duty flexible
conduit.(PDB to PSB/GAYSER. POINT/AC POINT/DG PANEL ACCL
TO EACH QTR ESSENTIAL LOAD) (4X4+2X2.5)
f) 2 nos single core 6 sq. mm copper wire for phase and neutral and
01 no of single core 2.5 sq. mm copper wire for earth continuty
conductor in 25 mm dia non metallic heavy duty flexible conduit
.(LFDB TO LBDB) (2X6+1X2.5)
g) 4 nos single core 6 sq. mm copper wire for phase and neutral and
02 nos of single core 2.5 sq. mm copper wire for earth continuty
conductor in 32 mm dia non metallic heavy duty flexible
conduit.(LFDB TO LBDB/power unit/point) (4X6+2X2.5)
h) 4 nos single core 10 sq. mm copper wire for phase and neutral
and 02 nos of single core 4 sq. mm copper wire for earth continuty
conductorin 32 mm dia non metallic heavy duty flexible conduit Mtr 188.00 463.68 87171.84
.(LFDB TO FLOOR PANEL TO TPN BDB light ) (4X10+2X4)
i) 4 nos single core 16 sq. mm copper wire for phase and neutral
and 02 nos of single core 10 sq. mm copper wire for earth continuty
conductor in 40 mm dia non metallic heavy duty flexible Mtr 42.00 696.64 29258.88
conduit.(FLOOR PANEL TO TPN BDB power) (4X16+2X10)
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
3 Supplying and fixing 20 amps, 240 volts, SPN, industrial type socket
outlet, with 2 pole and earth metal enclosed plug top along with 32
amps. C-series, SP MCB, in sheet steel enclosure, on surface or in
recess, with chained metal cover for the socket outlet, and complete
with connections, testing and commissioning etc. as required as per
direction of Engg.-in-Charge.. . Make-
Legrand/Schneider/Siemens/panasonic or equievalant reputed
make & model A catagory ISI marked as approved,All the
Components should be warrantied for a replacement period of 5
years against defects with ncessary test report & Warrnaty
certificate to be submitted to the department for genuinity of
product & to avail free aftersales service within warranty period
for acceptance of materials.
4 Supplying and fixing 32 amps, 415 volts, TPN, industrial type socket
outlet, with 4 pole and earth metal enclosed plug top along with 32
amps. C-series, TP MCB, in sheet steel enclosure, on surface or in
recess, with chained metal cover for the socket outlet, and complete
with connections, testing and commissioning etc. as required as per
direction of Engg.-in-Charge.. . Equievalant higher model of Make-
Legrand/Schneider/Siemens/panasonic equievalant reputed
make & model A catagory ISI marked as approved.All the
Components should be warrantied for a replacement period of 5
years against defects with ncessary test report & Warrnaty
certificate to be submitted to the department for genuinity of product
& to avail free aftersales service within warranty period for
acceptance of materials.
5 Supplying and fixing following size/ modules, GI box along with
modular base & metallic cover plate (both side) plate for modular
switches in recess etc as required as per direction of Engg.-in-
Charge. MAKE-Legrand/Siemens/Anchor/Panasonic/ Schneider
or equievalant reputed make & model A catagory ISI marked as
approved .All the Components should be warrantied for a
replacement period of 5 years against defects with ncessary
test report & Warrnaty certificate to be submitted to the
department for genuinity of product & to avail free aftersales
service within warranty period for acceptance of materials.
6 Supplying and fixing of following sizes of medium class PVC FRLS
conduit ISI marked along with accessories in surface/recess
including cutting the wall and making good the same in case of
recessed conduit as required as per direction of Engg.-in-Charge
.MAKE KINJAL/ AKG/Anchor or equievalant reputed make A
catagory ISI marked as approved
7 Supply and fixing modular type indicator on the existing switch
box/cover . Equievalant higher model of
Schneider/Hager/Siemens/Anchor/Panasonic make or
equievalant reputed make & model A catagory ISI marked as
approved as required as per direction of Engg.-in-Charge.All the
Components should be warrantied for a replacement period of 5
years against defects with ncessary test report & Warrnaty
certificate to be submitted to the department for genuinity of product
& to avail free aftersales service within warranty period for
acceptance of materials.
8 Supplying and installation of AC starter Modular type, Equievalant
higher model of Schneider/Hager/Siemens/Anchor/Panasonic
make or equievalant reputed make & model A catagory ISI marked
as approved coil voltage-415 Volt A.C. & O/L range of 9-14A range
on mod Box of suitable size including modular coveras required as
per direction of Engg.-in-Charge .All the Components should be Nos 41.00 691.04 28332.64
warrantied for a replacement period of 5 years against defects with
ncessary test report & Warrnaty certificate to be submitted to the
department for genuinity of product & to avail free aftersales service
within warranty period for acceptance of materials.
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
9 Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing
switch box/cover. Equievalant higher model of
Schneider/Hager/Siemens/Anchor/Panasonic make or
equievalant reputed make & model A catagory ISI marked as
approved .as required as per direction of Engg.-in-Charge.All the
Components should be warrantied for a replacement period of 5
years against defects with ncessary test report & Warrnaty
certificate to be submitted to the department for genuinity of product
& to avail free aftersales service within warranty period for
acceptance of materials.
15 S/F of Bakelite angle holder/batten holder (make-
Anchor/Havells/Panasonic or equievalant reputed make A catagory
ISI marked as approved )of ISI marked conforming to IS-1258/1987
in place of ceiling rose as per direction of Engg.-in-Charge .All the
Components should be warrantied for a replacement period of 5 EACH 40.00 64.96 2598.40
years against defects with ncessary test report & Warrnaty
certificate to be submitted to the department for genuinity of product
& to avail free aftersales service within warranty period for
acceptance of materials.
16 Supplying,fixing of Blanking plate(modular type)( falme retradant
type)) in existing switch box(anti bactorial & falme retradant type)
including supplying of all required accessories of ISI marked as
approved as per direction of engg-in-charge..Make-
Schneider(Zencelo)/legrand( Arteor) /Panasonic (vision),
complete suitable for IPH standard hospital.It should be
warrantied for a period of 10 years against manufacturing
defects against which ncessary test report & Warrnaty
certificate to be submitted to the department for genuinity of
product & to avail free aftersales service within warranty period
for acceptance of materials.
B Sub-Head II (Light fitting Fixture & Fan)
1 Supplying, installation, of exhaust fan of heavy duty 300 mm sweep
(Make-Equievalant higher model with 5 star rated of
Havells/almonard/Anchor/Panasonic/Usha/Halonix or
equievalant reputed make & model A catagory ISI marked as Nos 33.00 3422.72 112949.76
approved ) of exhaust fan in the existing wall, including fixing &
conntection as required as per direction of Engg.-in-Charge.
Replacement Warranty will be 5 years.
2 Supplying, installation, of exhaust fan of heavy duty 380 mm sweep
1400 rpm with louvers Make-Equievalant higher model with 5 star
rated of Havells/almonard/Anchor/Panasonic/Usha/Halonix or
equievalant reputed make & model A catagory ISI marked as
approved ) of exhaust fan in the existing wall, including fixing &
conntection .as required as per direction of Engg.-in-Charge.
Replacement Warranty will be 5 years.
3 Supplying, installation, testing and commssioning of 1400 mm sweep
white/milky colour ceiling fan Make-Equievalant higher model with
5 star rated of
Havells/almonard/Anchor/Panasonic/Usha/Halonix or
equievalant reputed make & model A catagory ISI marked as
approved ) including wiring the down rod of standard length (upto
30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core
cable etc. as required.(With fan Regulator) as required as per
direction of Engg.-in-Charge.Replacement Warranty will be 5 years.
4 Supplying, installation, testing and commssioning of 1200 mm sweep
white/milky colour ceiling fan Make-Equievalant higher model with
5 star rated of Havells/almonard/Anchor/Panasonic/Usha
/Halonix or equievalant reputed make & model A catagory ISI
marked as approved ) including wiring the down rod of standard
length (upto 30 cm) with 1.5 sq mm PVC insulated, copper
conductor, single core cable etc. as required as per direction of
Engg.-in-Charge,Replacement Warranty will be 5 years.. .(With fan
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
5 Supplying and fixing of Energy efficient Recess mounted LED
luminaire(IP-20) inverter made up of CRCA powder coated sheet
steel housing of 595 X 595 mm x 70 mm size with of not more than
36W and system lumens output not less than 3250 lumens (120 lm/
wt) with diffusers for better light transmission and pure effect with
High luminous flux LEDs for better light output, CRI not less than 80,
CCT of 5700-6500 degree K, THD less than 10%,internal surge
protection of 3 KV, complete with Non integrated isolated electronic
driver (protects the output /secondary side from any disturbance on No 2.00 4786.88 9573.76
the input / primary side ensuring safe operation)and all other
accessories suitable for operation on140- 270 V, 50 Hz ,L70
@50,000 burning hrs (5 years warranty)supply .as required as per
direction of Engg.-in-Charge (Make: HALONIX HLFPR22-05-36-CW-
R-INV or similar model of LT/Trilux /Philips/Panasonic /or
equievalant reputed make & model A catagory ISI marked as
approved.) . The luminaire must be Replacement Warranty will be 5
6 Supplying and fixing of Energy efficient surface mounted
square shape 18 W LED luminaire of dimension of 225x 225 x 35
mm consists of white powder coated , die-cast Alluminium housing
with high quality frosted diffuser for glare-free uniform lighting
distribution with wattage not more than 20 watt and lumen output of
1500 lumens, , CRI not less than 80,CCT of 6000 degree K,THD
less than 10%, with electronic driver, internal surge protection of 2.5
KV , L70 B50: 30000 hrs (2 yrs warranty) and all other accessories
suitable for operation on 220 V to 240 V supply as required as per
direction of Engg.-in-Charge. ( Make : (Make: wipro LD80-171-60-XX-
SM or similar model of LT/Trilux /Philips/Panasonic/HALONIX or
equievalant reputed make & model A catagory ISI marked as
approved).The luminaire should be Replacement Warranty will be 5
7 Supplying and fixing of Energy efficient recess mounted LED
luminaire with white powder coated ,pressure die-cast Al housing
,with high transmititivity,non-yellowing PMMA diffuser, with wattage
not more than 18 watt and lumen output not less than 2600 Lumen (
120 lumens/watt ) of size 595 x595 x 70 mm , ,CRI not less than
80,CCT of 5700-6500 degree K,THD less than 10%, with Non
integrated isolated driver (protects the output /secondary side from
any disturbance on the input / primary side ensuring safe operation), 2032.80 101640.00
all other accessories , life : 50,000 burning hours (5 years warranty) ,
Internal surge protection of 3 KV suitable for operation on 230 V, 50
Hz supply as required as per direction of Engg.-in-Charge. (Make:
wipro LDB1-171-XXX-60-SM or similar model of LT/Trilux
/Philips/Panasonic/HALONIX or equievalant reputed make & model
A catagory ISI marked as approved.) The luminaire should be
Replacement Warranty will be 5 years.
8 SITC of energy efficient LED tube light fittings with decorative
alluminium batten and LED tube light having power rating not more
than 20 watt and lumen output not less than 2200 lumen complete
with electronic driver and all other accessories with diffuser having 5
years warranty i/c connection etc as required as per direction of
Engg.-in-Charge. ( (Make: wipro LL20-221 --or similar model of
LT/Trilux /Philips/Panasonic/HALONIX or equievalantreputed make
& model A catagory ISI marked as approved.). The luminaire
should be Replacement Warranty will be 5 years .
9 SITC of Sleek LED 10 watt mirror light fitting with extruded
polycarbonate housing,High optically efficient diffuser,above wash
basin complete with all accessoriesetc. directly on wall, including
connection with 1.5 sq. mm FRLS PVC insulated, copper conductor,
single core cable and earthing etc. as required as per direction of
Engg.-in-Charge. Nos 20.00 813.12 16262.40
( Make : WIPRO Model No:LL20-111-XXX-60-NE or similar model
of PHILIPS/Panasonic/HALONIX or equievalant reputed make &
model A catagory ISI marked as approved. )The luminaire should
be Replacement Warranty will be 5 years
10 SITC of IP 20 Non-integral flexible LED strip light,High optically
efficient diffuser,, 3000K with 12 w/mtr @ 5Mtr pool with Driver extra
as required as per direction of Engg.-in-Charge ( Make : (Make:
wipro LS06-005-120---or similar model of LT/Trilux
/Philips/Panasonic or equievalant or similar model of
/PHILIPS/Wipro/HALONIX or equievalant reputed make & model
A catagory ISI marked as approved. )The luminaire should be
Replacement Warranty will be 5 years
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
11 Supplying and fixing of small focus light for small monuments as 6W
, 4000 K required as per direction of Engg.-in-Charge (Make:
wiproLD98-900----or similar model of LT/Trilux
/Philips/Panasonic/HALONIX or equievalant reputed make & model
A catagory ISI marked as approved.)The luminaire should be
Replacement Warranty will be 5 years
12 Supplying and fixing of step light for gallery STEP as 3W , 2000 K
required as per direction of Engg.-in-Charge (Make: wipro LT51 -
370-XXX-30-XX or similar model of LT/Trilux /Philips/Panasonic or
equievalant reputed make & model A catagory ISI marked as
approved.)The luminaire should be Replacement Warranty will be 5
13 Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe
15 mm dia, heavy gauge including painting etc. as requiredas
required as per direction of Engg.-in-Charge . Nos 150.00 34.72 5208.00
(Note : More than 5 cm length shall be rounded to the nearest 10 cm
and 5 cm or less shall be ignored)of ISI mark as approved.
14 SITC of energy efficient occupancy sensor having power rating not
more than 10 watt and all other accessories connection etc as
required as per direction of Engg.-in-Charge. ( similar model of
WIPRO CRP MODEL or similar model of / /PHILIPS/Panasonic Nos 4.00 3904.32 15617.28
or equievalant reputed make & model A catagory ISI marked as
approved. The luminaire should be Replacement Warranty will
c) BDBS,DB,AC DB,FLOOR PANELS,MCBS
1 Supplying and fixing of following mentioned way, three pole/single
pole and neutral, sheet steel,double door MCB distribution board,
415 volts/240 volts shall be as per IEC 61439-3,integrated door
earthing system offering additional safety to the user,High quality
polyurethane Gasket,the box and cover shall be fabricated to
withstand IK09,the DB should be properly pre-treated with 7 tank
process and duly powder coated, phosphatized with powder coated
finish, on surface/recess, complete with terminal blocks,with suitable
size FR PVC insulated copper conducter up to terminal blocks,
tinned copper busbar, neutral busbar, earth bar, din bar. Make-
LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti
9/Panasonic(Equivalant model) /ABB(Equivalant model) or
equievalant reputed make & model A catagory ISI marked as
approved. as per direction of Engg.-in-Charge. The Distribution
boards should be Replacement Warranty will be 5 years
a) 4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC
61439-3 suitable for Flush mounting and Surface mounting with
100A Copper Bus Bar for each phase, with neutral Bus bar, Earth
Bar & Cable ties for cable management, prefitted masking sheet, Nos 13.00 2415.84 31405.92
IP43-IK09 with metal door(FOR LIGHT,POWER INDOOR,3-
PH,POWER LOAD) Warranty on DB is 2 years.
b) Supply and fixing of 12 way DD single pole and neutral sheet steel
MCB distribution board 250V on surface/recess complete with tinned
copper bus bar, neutral bus bar, earth bar, din bar, detachable gland
plate, interconnections, phosphatized and powder painted including
earthing etc. as required (but with out MCB/ RCCB/ Isolator) (ALL
LIGHT WITH CORRIDOOR/COMMON AREA,EM LIGHT,UPS
LOAD, EM LOAD LIGHT LOAD,POWER LOAD )
c) 2+4 way MCB Enclosure DB (GLAZED door)(only each EM.
CONNECTION UPS LOAD)
2 Supplying and fixing 20 amps rating, 240 volts, C series, Double
poles MCB of Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/
Schneider- Acti 9/L&T (Equievalant
model)/Panasonic(Equivalant model) /ABB(Equivalant model) or
equievalant reputed make & model A catagory ISI marked as
approved in the existing MCB DB complete with connections as per Nos 6.00 370.72 2224.32
direction of Engg.-in-Charge. The MCB should be Replacement
Warranty will be 5 years .MCB should have the fault indication
system in different colour for ON, OFF & TRIP condition or Mid trip
position for Trip conditions for easier identification of fault.Warranty
on MCB is 5 years.
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
3 Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,
single poles MCB of Make-LEGRAND-Ekinox3 DB/ Siemens-
Betaguard/ Schneider- Acti 9/L&T (Equievalant
model)/Panasonic(Equivalant model) /ABB(Equivalant model) or
equievalant reputed make & model A catagory ISI marked as
approved. the existing MCB DB complete with connections as per Nos 270.00 145.60 39312.00
direction of Engg.-in-Charge. The MCB should be Replacement
Warranty will be 5 years.MCB should have the fault indication
system in different colour for ON, OFF & TRIP condition or Mid trip
position for Trip conditions for easier identification of fault.Warranty
on MCB is 5 years.
4 Supplying and fixing 25Amps DP 240 volts, RCCB,300mA Make-
Equievalant higher model of Legrand/Snheider/Siemens /
L&T/Panasonic /ABBor equievalant reputed make & model A
catagory ISI marked as approved in the existing MCB DB in the
existing MCB DB complete with connections as per direction of
Engg.-in-Charge. The RCCB should be Replacement Warranty will
5 Supplying and fixing 40Amps DP 240 volts, RCCB,300mA Make-
Equievalant higher model of Legrand/Snheider/Siemens /
L&T/Panasonic /ABB or equievalant reputed make & model A
catagory ISI marked as approved in the existing MCB DB in the
existing MCB DB complete with connections as per direction of
Engg.-in-Charge. The RCCB should be Replacement Warranty will
6 Supplying and fixing 63Amps TPN 415 volts, RCCB,300mA Make-
Equievalant higher model of Legrand/Snheider/Siemens /
L&T/Panasonic /ABB or equievalant reputed make & model A
catagory ISI marked as approved in the existing MCB DB in the
existing MCB DB complete with connections as per direction of
Engg.-in-Charge.(for power BDB & AC ODU, 8 way TPN BDB
IC).The RCCB should be Replacement Warranty will be 5 years
D (Earthing) INSTALLATION
1 S/IT/C Of Earthing with copper earth plate 600 mm x 600mm x 6 mm
thick ISI marked including accessories and providing masonary with
cover plate having loccking arrangement and watering pipe etc
(WITH charcoal and salt) as required as per direction of Engg.-in-
Charge. The entire earthing system should be Replacement
Warranty will be 5 years
2 S/IT/C of materials and installation of pipe earth electrode made out
of 50mm dia class B G.I. pipe of 3.0 metre long with arrangements
for fitting/ termination of G.I. flat / wire with G. I. nut bolts &
washers including cost of burnt wood charcoal, salt, foreign soil,
water pouring arrangements, brick masonary enclosure on top with Nos 4.00 2747.36 10989.44
removable RCC cover complete with labour for excavation of pit in
all kinds of soil & rock as required and as per direction of Engineer-in-
charge.The entire earthing system should be Replacement
Warranty will be 5 years
3 Providing and fixing 4 mm dia copper wire on surface or in recess for
loop earthing as required.as per direction of Engg.-in-Charge. Mtr 255.00 104.16 26560.80
4 Providing and fixing 25mm x 5 mm copper strip on surface or in
recess for connections etc. as required as per direction of Engg.-in- Mtr 111.00 576.80 64024.80
5 Providing and fixing 50mm x 5 mm copper strip on surface or in
recess for connections etc. as required as per direction of Engg.-in- Mtr 12.00 1072.96 12875.52
6 Supplying and making brick massonary pedastal with extra super
structure including cement plastering etc as required as per direction Mtr 2.00 2800.00 5600.00
of Engg.-in-Charge.
E CABLING AND END TERMINATION MAIN AREA
1 Supplying of one number PVC insulated armoured and PVC
sheathed XLPE property AL. conductor power cable of 1.1 KV
grade POLYCAB/HAVELLS/Finolex or equievalant reputed make
ISI marked as approved of following size cables as per direction of
Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be
submitted to the department for genuinity of product & to avail free
after sales service within warranty period for acceptance of materials
b) 3.5core x 185 sq mm (MAIN PANEL,3 runs) Mtr 488.00 984.10 480240.41
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
1.1 Supplying of one number PVC insulated armoured and PVC
sheathed XLPE property AL. conductor power cable of 1.1 KV
grade POLYCAB/HAVELLS/Finolex or equievalant reputed make
ISI marked as approved of following size cables as per direction of
Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be
submitted to the department for genuinity of product & to avail free
after sales service within warranty period for acceptance of materials
a) 3.5core x 70 sq mm ( FOR DG POWER ) Mtr 266.00 427.38 113683.29
b) 4core x 16 sq mm (MDB TO FDBL/FDBU SUB,BDB) Mtr 45.00 163.08 7338.74
c) 4 core x 4 sq mm (for small power/LIGHT TO POLE) Mtr 45.00 98.41 4428.65
d) 3.5core x 35 sq mm (To power BDB/UPS PANEL) Mtr 45.00 244.62 11007.86
2 LAYING OF CABLE
2.1 Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv
grade size not exceeding 25 SQ. MM direct in ground in the trench
in one horizental formation including excavation ,sand coushing Mtr 35.00 140.00 4900.00
protection covering and refilling the trench etc as required as per
direction of Engg.-in -charge.
2.2 Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv
grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM
direct in ground in the trench in one horizental formation including
excavation ,sand coushing protection covering and refilling the
trench etc as required as per direction of Engg.-in -charge.
2.3 Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv
grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM
direct in ground in the trench in one horizental formation including
excavation ,sand coushing protection covering and refilling the
trench etc as required as per direction of Engg.-in -charge.
2.4 Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv
grade size not exceeding 25 SQ. MM direct in ground in the
EXISTING PIPE etc as required as per direction of Engg.-in -charge.
2.5 Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv
grade size exceeding 25 SQ. MM but not exceeding 400 SQ. MM
direct in ground in the EXISTING PIPE etc as required as per
direction of Engg.-in -charge.
2.6 Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv
grade size not exceeding 25 SQ. MM in open duct etc as required Mtr 44.00 35.84 1576.96
as per direction of Engg.-in -charge.
2.7 Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv
grade size exceeding 25 SQ. MM in open duct 400 SQ. MM direct
in ground in the EXISTING PIPE etc as required as per direction of
Engg.-in -charge.
2.8 Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv
grade size not exceeding 25 SQ. MM in surface with shaddle and
screw etc as required as per direction of Engg.-in -charge.
2.9 Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv
grade size not exceeding 120 SQ. MM From 25 SQ. MM in surface
with shaddle and screw etc as required as per direction of Engg.-in -
2.10 Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv
grade size not exceeding 400 SQ. MM From 120 SQ. MM in
surface with shaddle and screw etc as required as per direction of
Engg.-in -charge.
3 Supplying and making end termination with brass compression gland
and aluminium lugs for following mentioned size cable.as per
direction of Engg.-in-Charge.
4 Providing,fixing and laying of fallowing dia G.I. pipe (medium class)
in ground complete with G.I fitting incl. trenching(75 mm depth)and
refilling as per direction of Engg.-in-Charge.
5 Providing,fixing and laying of fallowing dia HDPE pipe (medium
class) in ground complete with fitting incl. trenching(75 mm
depth)and refilling as per direction of Engg.-in-Charge.
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
1 S/I/T&Commissioning of LT indoor floor mounted cubical type
electrical main panel (for both light and power circuit) made out by
2mm CRCA steel sheet duly derusted & pented by simens gray
powder cote paint is designed as G.A drawing as per direction of
Engg.-in-Charge. Warrentee period of replacement of panel &
accessories must be 5 years & compelete test certificate must be
submitted along with panel board including component list.
In commer- 01 number of 400(250-400) Amps 4P MCCB with Rom
& sprader link,36 kA. . (make-
ABB/Siemens/SCHNEIDER/L&T/Legrand, ISI
marked)(Icu=100%Ics)with shunt trip.with axulary for BMS
In commer DG- 01 number of 200(160-200) Amps 4P MCCB with
Rom & sprader link,25 Ka &7 01 no of 200A 4P O/L changeover
switch. . (make-ABB/Siemens/SCHNEIDER/L&T/Legrand, ISI
marked)(Icu=100%Ics)with shunt trip.with axulary for BMS
Busbar- 04 numbers of 400Amps Electrolytic copper busbar duly
sleeved by color coaded PVC sleeve & supported by suitable size
Busbar DG - 04 numbers of 200Amps Electrolytic copper busbar
duly sleeved by color coaded PVC sleeve & supported by suitable
size DMC insulator.
Out going- (i) 63A 4P MCB 10 NOS FOR POWER BDB GF,FDB L
1F,2F & 3F (Legrand/Schneider make)
Out going- (ii) 04 nos 32A 4P MCB LIGHT BDB AC IDU
BDB/LIGHT BDB,LIFT,WATER(Legrand/Schneider make)
Out going- (iii) 03 nos 100A 4P MCCB,with ROM & s,link,25kA.FDB
P & SPARE(Legrand/Schneider make)
Out going- (iv) 01 no 160A 4P MCCB,with ROM & s,link,25kA.FIRE
& SPARE(Legrand/Schneider make)
Instrument- (i) 06 numbers phase indicating lamp with toggle switch
(ii) 01 set of digital type multifunction meter with CT for
voltage,current,frequency,PF,THD indication
(iii) 04 nos of 70kA SP VSD WITH 32A SP MCB
FDB POWER 1F,2F & 3F
2 S/I/T&Commissioning of LT indoor floor mounted cubical type
electrical main panel (for both light and power circuit) made out by
2mm CRCA steel sheet duly derusted & pented by simens gray
powder cote paint is designed as G.A drawing as per direction of
Engg.-in-Charge. Warrentee period of replacement of panel &
accessories must be 5 years & compelete test certificate must be
submitted along with panel board including component list.
In commer- 01 number of 100(80-100) Amps 4P MCCB with Rom &
sprader link,25 kA. . (make-
ABB/Siemens/SCHNEIDER/L&T/Legrand, ISI
marked)(Icu=50%Ics)with shunt trip.with axulary for BMS
Busbar - 04 numbers of 125Amps Electrolytic copper busbar duly
sleeved by color coaded PVC sleeve & supported by suitable size
Out going- (i) 63A 4P MCB 4 NOS FOR POWER BDB
(Legrand/Schneider make)
Out going- (ii) 02 nos 32A 4P MCBAC IDU
BDB/SPARE(Legrand/Schneider make)
Instrument- (i) 03 numbers phase indicating lamp with toggle switch
(ii) 01 set of digital type multifunction meter with CT for
voltage,current,frequency,PF,THD indication
FDB LIGHT 1F,2F
3 S/I/T&Commissioning of LT indoor floor mounted cubical type
electrical main panel (for both light and power circuit) made out by
2mm CRCA steel sheet duly derusted & pented by simens gray
powder cote paint is designed as G.A drawing as per direction of
Engg.-in-Charge. Warrentee period of replacement of panel &
accessories must be 5 years & compelete test certificate must be
submitted along with panel board including component list.
In commer- 01 number of 32Amps 4P MCB 10 kA. . (make-
ABB/Siemens/SCHNEIDER/L&T/Legrand, ISI marked)
Busbar DG - 04 numbers of 63Amps Electrolytic copper busbar duly
sleeved by color coaded PVC sleeve & supported by suitable size
Out going- (i) 32A 2P MCB 6 NOS FOR LIGHT BDB
(Legrand/Schneider make)
Out going- (ii) 01 no 20A 4P MCB AC IDU
BDB/SPARE(Legrand/Schneider make)
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
Instrument- (i) 03 numbers phase indicating lamp with toggle switch
(ii) 01 set of digital type multifunction meter with CT for
voltage,current,frequency,PF,THD indication
EMERGENCY UPS FDB,COMPUTER ROOM
4 S/I/T&Commissioning of LT indoor floor mounted cubical type
electrical main panel (for both light and power circuit) made out by
2mm CRCA steel sheet duly derusted & painted by simens grey
powder cote paint is designed as G.A drawing. (FOR ALL MAIN
CONNECTED LOAD) BUILDING EMERGENCY LIGHT)as per Set 2.00 27252.96 54505.92
direction of Engg.-in-Charge. Warrentee period of replacement of
panel & accessories must be 5 years & compelete test
certificate must be submitted along with panel board including
component list.
In commer- 01 no 32A 4P MCB 10kA,C series with on/off trip
indication UPS Light load for each floor. ( Make-LEGRAND-
Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T
(Equievalant model)/Panasonic(Equivalant model)
/ABB(Equivalant model)or equievalant make with proper model
Busbar- 04 numbers of 63Amps,50kA Electrolytic copper busbar
duly sleeved by color coded PVC sleeve & supported by suitable
size DMC insulator.
Out going- 06 nos 25A 2P MCB 10kA,C series UPS Light load for
each area UBDB. ( Make-LEGRAND-Ekinox3 DB/ Siemens-
Betaguard/ Schneider- Acti 9/L&T (Equievalant
model)/Panasonic(Equivalant model) /ABB(Equivalant model)or
equievalant make with proper model ISI marked)
Instrument- (i) 03 numbers phase indicating lamp with toggle switch
(ii) 01 set of 0-60Amps Ammeter with
CTS.(DIGITAL)(Sicure/L&T,CT-KAPPA or equievalant make &
(iii) 01 set of 0-500 voltmeter .(DIGITAL)(Sicure/L&T or equievalant
1 Supply ,installation ,testing & commissioning of 10KVA ON LINE
UPS SYSTEM WITH suitable size battery bank, rated of battery &
isolation transformer, IGBT based inverter system with inbuilt
isolation transformer & automatic phase sicuency corrector of 3ph in
put to 3 ph output,415V,protection for fault by OL,UV,EF,GF,OC,Ph.
Sicuency release of equievalant model of APC/ Schneider/
RELLIO/ Emersion or equievalant reputed make A catogory, ISI
marked as approved ) including supply of rack inverter stand with Set 1.00 304075.52 304075.52
sufficient backup upto 1 hour with all required accessories to
complete the job including all connection.LOAD OF CONF.) as per
direction of Engg.-in-Charge. Warrentee period of all accessories
& component & system must be 5 years & compelete test
certificate must be submitted along with ups including
component list & SLD.
CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWER
HOT DIPP GALVANIZED(GC) AS PER EN-ISO-1461 , CARBON
STEEL WIRE MESH CABLE TRAYS with internal dimensions of
size 54mm(H) x 200mm(W), of Legrand - Cablofil make or
equievalant reputed make & model A catogory, ISI marked as
approved .The Load bearing capacity of the Cable Trays should be
1 minimum of 104.8Kg/meter at the span of 1.5Meter as per UL mtrs 15.00 666.40 9996.00
specifications.(With all accessories,bend,cover,supporter)WITH
REQUIRED SIZED JUNCTION BOX ,COVER CONNECTOR as
required as per direction of Engg.-in-Charge. Warrentee period oftray
must be 5 years & compelete test certificate must be submitted .
HOT DIPP GALVANIZED(GC) AS PER EN-ISO-1461 , CARBON
STEEL WIRE MESH CABLE TRAYS with internal dimensions of
size 54mm(H) x 300mm(W), of Legrand - Cablofil make or
equievalant reputed make & model A catogory, ISI marked as
approved .The Load bearing capacity of the Cable Trays should be
2 minimum of 104.8Kg/meter at the span of 1.5Meter as per UL mtrs 15.00 772.80 11592.00
specifications.(With all accessories,bend,cover,supporter)WITH
REQUIRED SIZED JUNCTION BOX ,COVER CONNECTOR as
required as per direction of Engg.-in-Charge. Warrentee period oftray
must be 5 years & compelete test certificate must be submitted .
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
HOT DIPP GALVANIZED(GC) AS PER EN-ISO-1461 , CARBON
STEEL WIRE MESH CABLE TRAYS with internal dimensions of
size 54mm(H) x 400mm(W), of Legrand - Cablofil make or
equievalant reputed make & model A catogory, ISI marked as
approved .The Load bearing capacity of the Cable Trays should be
3 minimum of 104.8Kg/meter at the span of 1.5Meter as per UL mtrs 10.00 1022.56 10225.60
specifications.(With all accessories,bend,cover,supporter)WITH
REQUIRED SIZED JUNCTION BOX ,COVER CONNECTOR as
required as per direction of Engg.-in-Charge. Warrentee period oftray
must be 5 years & compelete test certificate must be submitted .
I INSTALLATION OF 1X100KVA DG ONLY FOR EMERGENCY
1.0 Supply, Transportation, erection, testing and commissioning of 3
Phase, 415V, 50Hz, water cooled multi cylinder diesel generator set
with alternator of 100KVA ( Make -Kirloskar / Jakson / sterling) out
put contineous rating directly coupled Engine and Alternator with
guard and mounted on a common base plate of Robust construction
and complete with AMF panel having IP-52 protection, Acoustic
Enclosure as per CPCB norms , sound absorbing material, to restrict
sound level up to 75 dB up to 1 mtr distance and as per CPCB
norms etc as per following specifications mentioned below.
A. Alternator make : Kirloskar / Stamford / Crompton Greaves /
Leroy Somer /Caterpillar or equievalant reputed make & model ISI
marked as approved as per direction of Engg.-in-Charge. Warrentee
period of panel must be 5 years & compelete test certificate
must be submitted along with DG set including component list
& smoke exhaust system drawing,certified ISO 8528
a) ALTERNATOR:The alternator of the output rating shall be 3 Phase,
415V, 50Hz, Ac , 0.8 P.F. lagging at 1500 RPM. The alternator is self
excited, self regulated, and shall confirm to IS: 13364 of 1992 with
regulation of +5% from no load to full load. degree of protections
b) ENGINE: Diesel Engine make : Kirloskar / Cummins / Caterpillar /
Perkins /Volvo penta /Ashok Leyland / Mahindra & Mahindra /
Greaves Cotton /Tata or equievalant make & model ISI marked as
approved . Diesel Engine start, developing suitable BHP output at
1500 RPM with mechanical / electronic governing so as to enable
the alternator to give 100KVA continuous output at 0.8 P.F. lagging
at NTP conditions. The diesel engine shall be capable of providing
10% O/L for 1 Hr for every 11 Hrs of continuous running at full load.
The engine with 1st filling of oil and Diesel etc.
01. Exhaust pipe of required size and length with insulation or
02. Diesel tank suitable for 8 to 10 Hours running capacity.
03. Residential Silencer.
04. SMF Batteries with leads as per the Manufacturer standards
c) AMF PANEL: Cubical, Compartmentalized, AMF Panel Baord with
all Power & Control Contractors, Switches, Meters and other
accessories, Internal Wiring, connection, inter-connection etc. for
Trouble Free smooth function for 100KVA DG Set complete with
Battery Charger & leads as required.
d) BASE PLATE: Common Base Plate of required size for mounting of
Engine Alternator Set fabricated from MS Channerl and vibration
damping arrangement with cushy foor mounting including paintng
etc. as required.
e) FOUNDATION: Suitable size Cement Concrete (1:2:4) foundation
duly plastered and finished with neat coat Cement as required along
with smoke exhaust system piping including base frame of structure
& lightening protection system. *It also includes 2 nos GI pipe
earthing for body and 2 nos copper plate earthing for neutral, control set 1.00 1451092.16 1451092.16
cable of 15mtr 2.5sqmm 6core , civil foundation work.
(The Manufacturing of DG set shall not in any case be more than six
months old from the date of award of work)
J 6 PASSENGER LIFT WITH WIRRING(1.1)
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
1 Design Supply, Installation, Testing & Commissioning and
putting into operation with compelete inspection by concerned
electrical inspector, Director Factory and Boilers, Odisha with
proper testing certificate and final testing of Automatic Lift
complete with all standard equipments accessories and control
equipments as per Manufacturer's Design with lift control panel
including BMS facility and as per BIS and fulfilling following
requirements.It includes supply,laying of power cable and fixing
of glands,lugs etc.( Machine room less, Gearless Type).Design
and as per CPWD /OPWD specification (Part - III Lifts) 1981 with
valid lisence for installation and fulfilling following requirements
on turnkey basis as per direction of Engg.-in-Charge. LIFT OF
machineroom less type(Make-
Kone/Junction/OTIS/Schindler/Thysenkrup or equievalant
reputed make & model A catogory, ISI marked as approved
)Warrentee period of accessories & system must be 5 years &
compelete test certificate must be submitted along with Lift
including component list .
Type: PASSENGER LIFT
Load: 6 PASSENGER(408KG)
Speed: 1.0 Meter Per Second.
Control: Variable voltage with variable frequency
Operation: Microsprocessor based simplex collective selective with /
without Lift Attendant.
Total Rise: About 12 Meters.
Landings: For All on same side.
Floors Served: GF,1F,2F,3F
Signals: Digital Car Position Indicator, Car Travel direction Indicator
in Car & at all Landings.
Lift Shaft Size: About as 6 passenger lift standard, finished with
Lift Car Size: About lift standard.
Car Entrance: Clear Opening lift standard high Protected with Car
Landing Entrance: Clear Opening lift standard high Protected with
Car Door: Stainless with front glass to transparent Two Panel Center
opening flush type.outer visible.
Landing Door: Mild Steel Two Panel Center opening flush type P.
Door Operation: Automatic Electric Power operated Door with in
infrared protection.
Car Interior: Stainless Steel Panel with Hair line finish on all sides.
Car Floor: Hard Wood covered with PVC / Marblex Tiles.
Car Ceiling & Lighting: Fluorescent Lighting Concealed by
suspended false ceiling with plain acrylic diffiuser. The frame of
suspended false ceiling shall be of powder coated Aluminum.
Car Ventilation: Pressure Fan with anodized Aluminum Grill.
Emergencing Lighting in Car: Battery operated Emergencing Lighting
in the Lift Car.
Intercom System: Battery operated intercom system in Lift Car and
Emergencing Alarm: Battery operated Alarm Bell System in Lift Car
and Control Room.
Position of Machine Room: Directly above the Lift Shaft.
Electric Power Supply: AC 415 Volt 3 Phase 50 Hz terminated in
control room along with control panel with facility of BMS connectivity
system .The scope of lift control panel is inclussive with lift vender
OTHER SPECIAL PROVISIONS
• VVVF CONTROLLER
• AUTOMATICE RESCUE DEVICE (ARD)
• EMERGENCY LIGHT AND BATARY OPERATED ALARAM BELL
• DOT MATRICKX SEVEN SIGMENT DIGITAL POSITION
• FIRE RATED DOOR FOR 1 HOUR
• 3 WAY INTER COM/PRESS AND SPEAK BUTTON WITH HAND
• FLOOR ANNUNCIATOR WITH MUSIC
• INFRA RED SCREEN
• OVER LOAD WARNING INDICATOR
• BRAILLE BUTTONS
• FREE SERVICE FOR 5 YEARS
• FULL CAR HEIGH CAR FIXTURE ARRIVAL CHIME
• PROVISION FOR CC CEMARA WITH INSTRUEMENT
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
Fire Man Switch: Fire Man Switch at Main Landing Terminal. JOB 2.00 1160164.32 2320328.64
1.0 Supply,installation, testing and commissioning of 4 P&T & 14
Extensions Hybrid EPABX System
2.0 Supply,installation, testing and commissioning of RJ11 Modular
Complete in concealed manner including termination of cable
3.0 Supply & Laying of 2 Core 0.5mm telephone cable using Rigid PVC
Pipe in concealed manner per running metre of cable laid.
4.0 Supply,installation, testing and commissioning of Electronic Push
Button Telephone with Caller ID
5.0 Supply,installation, testing and commissioning of GSM FCT Terminal
6.0 Supply,installation, testing and commissioning of Lightening
Protector for P&T Lines
7.0 Supply,installation, testing and commissioning of 12v 7 Ah Battery
including termination
1.0 Supply,installation, testing and commissioning of 16 Port Gigabit
Ethernet Switch.
2.0 Supply,installation, testing and commissioning of RJ45 Modular
Complete in concealed manner including termination of cable
3.0 Supply & Laying of Cat 6 cable using Rigid PVC Pipe in concealed
manner per running metre of cable laid.
4.0 Supply,installation, testing and commissioning of Patch Panel, 9U
Rack, Cable Manager, Cooling Fan x 2 Nos., Earthing Kit, Power Set 1.00 16800.00 16800.00
5.0 Supply,installation, testing and commissionining of 1 Mtr Patch Cord
6.0 Supply,installation, testing and commissionining of 3 Mtr Patch Cord
1.0 Supply,installation, testing and commissioning of 8 Channel DVR
with 2 Sata Ports
2.0 Supply,installation, testing and commissioning of 4 MP Dome / Bullet
Camera with 25 Mtrs IR Range
3.0 Supply & Laying of RG59+ 3 Core cable using Rigid PVC Pipe in
concealed manner per running metre of cable laid.
4.0 Supply,installation, testing and commissioning of BNC & DC
5.0 Supply,installation, testing and commissionining of 4 TB CCTV
Surveillance Hard Disk
6.0 Supply,installation, testing and commissionining of 10 Amps Power
7.0 Supply,installation, testing and commissioning of 32" LED Monitor
8.0 Supply,installation, testing and commissioning of 10 Mtrs HDMI
9.0 Supply,installation, testing and commissioning of Bird Canopy Nos 37.00 840.00 31080.00
10.0 Supply,installation, testing and commissioning of Wireless Mouse
SINE WAVE INVERTOR & SERVO
Supply,installation, testing and commissioning of 960 VA INVERTOR
2.0 Supply,installation, testing and commissioning of Battery Rack Nos 1.00 2800.00 2800.00
3.0 Supply,installation, testing and commissioning of Tall Tubular 150Ah
4.0 Supply,installation, testing and commissioning of 2 KVA Servo with
90V to 270 Volts Input Voltage, High Voltage Cuttoff & 30 Seconds Nos 1.00 22400.00 22400.00
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
1 Supply ,Installation testing commissioning of 45W, High efficient
LED with aluminium housing in Pure Polyster UV resistant powder
coated black finish and Top maintainable product with top opening
die cast cover with acrylic clear glass reflector.CRI>70, IP66,
Ambient temp-0 to 45DegC, Driver efficiency>85%, CCT-
4000/5700K,THD<10%,Powerfactor>0.95, Surge protection-4 kV,
Multistage Isolated Constant Current-Constant Voltage operated
driver with range 150-300V AC and Safety Extra Low Voltage Safe
level<60V DC as per IEC standard. Luminaire lumen ≥ 4275 lumens
(95 lm/W). Similar to Wipro Make LP07-501-XXX-57-CL or
equivalent Philips/ LT/Trilux make. & model A catogory, ISI marked
as approved, with proper model make having warrantied for a period
of 5 years . The luminaire to be installed in 6 mtr long GI hot dip Sets 15.00 25299.68 379495.20
galvanized smart pole with anti corroson,,uv rays stabilized,metal
post with covered by resin of
Fumatech/Valmount/Transrail/RR/UTKASH /Utkal Galvanizer make
equievalant make with proper model complete with SA bracket
internal JB with 4 way connector and MCB as per the pole drawing
and direction of EIC against which inspection mat take place. It
should be installed after making proper size RCC foundation by
considering RCC foundation by using M20 grade RCC & Fe 415
grade reinforcement and fixing the 4 nos. En 8 grade J type fdn bolts
in the foundation. The luminaire needs to be wired with 3 c 1 sq mm
wire from JB as per the direction of Engg-in -charge.
3 Supplying, Erection, Fixing, connection & testing of 45 LED GATE
Light of WIPRO make or equvalant of Philips/LT/PANASONIC or
equievalant reputed make A catagory ISI marked as approved
maintenance free having 2 years warranty G.I P ipe with braket Sets 2.00 14253.12 28506.24
including MCB box & including with foundation as per the Drawing
for inspection as required & as per direction of Engg.-in-Charge.
4 Supplying, Erection, Fixing, connection & testing of 8W, High
efficient LED with Aluminium housing with clear toughened glass
diffuser.CRI>70, IP65, CCT - 2700K, Ambient temp-0 to 45 DegC,
Driver efficiency>85%,THD<25%, Powerfactor>0.95, Surge
protection-2 kV, Multistage Isolated Constant Current-Constant
Voltage driver and Safety Extra Low Voltage Safe level<60V DC as
per IEC standard. Luminaire lumen ≥ 600 lumens (75 lm/W). Similar
to Wipro Make LF05 or equivalent Philips/ LT/Trilux make. as per the
Drawing for inspection as required & as per direction of Engg.-in-
5 Supplying ,installation & fixing of 11W, High efficient LED with
extruded Aluminium housing with PC diffuser.CRI>70, IP65, CCT -
6500K, Ambient temp-0 to 45DegC, Driver
efficiency>80%,THD<25%, Powerfactor>0.9, Surge protection-2 kV,
Multistage Isolated Constant Current-Constant Voltage driver and
Safety Extra Low Voltage Safe level<60V DC as per IEC standard.
Luminaire lumen ≥ 565 lumens (51 lm/W). Similar to Wipro Make
LB12-131-XXX-65-05 or equivalent Philips/ LT/Trilux make. including
with foundation as per the Drawing for inspection as required & as
per direction of Engg.-in-Charge.
6 Supply of materials and installation of pipe earth electrode made out
of 50mm dia class B G.I. pipe of 3.0 metre long with arrangements
for fitting/ termination of G.I. flat / wire with G. I. nut bolts &
washers including cost of burnt wood charcoal, salt, foreign soil,
water pouring arrangements, brick masonary enclosure on top with Nos 4.00 2747.36 10989.44
removable RCC cover complete with labour for excavation of pit in
all kinds of soil & rock as required and as per direction of Engineer-in-
charge.The entire earthing system should be Replacement
Warranty will be 5 years
7 Providing and fixing 4 mm dia copper wire on surface or in recess for
loop earthing as required as per direction of Engg.-in-Charge. Mtr 333.00 104.16 34685.28
8 Providing and fixing 25mm x 5 mm copper strip on surface or in
recess for connections etc. as required as per direction of Engg.-in- Mtr 26.00 576.80 14996.80
CABLING 0.00 0.00
10 Supplying and laying of one number PVC insulated armoured and
PVC sheathed XLPE AL. conductor power cable of 1.1 KV grade
POLYCAB/FINOLEX/HAVELLS or equievalant reputed ISI
MARKED MAKE of following size cables as per direction of Engg.- 0.00 0.00
in-Charge.Ncessary test report & Warrnaty certificate to be
submitted to the department for genuinity of product & to avail free
after sales service within warranty period for acceptance of materials
a) 4core x 10 sq mm (OFP TO IND. TIMER PANEL) Mtr 133.00 149.96 19944.25
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
11.1 Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv
grade size not exceeding 25 SQ. MM direct in ground in the trench
in one horizental formation including excavation ,sand coushing Mtr 133.00 140.00 18620.00
protection covering and refilling the trench etc as required as per
direction of Engg.-in -charge.
11.2 Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv
grade size not exceeding 120 SQ. MM From 25 SQ. MM in surface
with shaddle and screw etc as required as per direction of Engg.-in -
12 S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical
type MCB ENCLOSURE made out by 2mm CRCA steel sheet duly
derusted & pented by simens gray powder cote paint is designed as
G.A drawing. (FOR USE) with 20A TPN MCB 01
NOLegrand/Schneider/L&T/ABB or equievalant make & model as Set 2.00 2289.28 4578.56
per direction of Engg.-in-Charge. Ncessary test report & Warrnaty
certificate to be submitted to the department for genuinity of product
& to avail free after sales service within warranty period 2 years of
acceptance of materials
13 Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated
cover of reputed make,ISI marked with all other concerned materials
as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty
certificate to be submitted to the department for genuinity of product
& to avail free after sales service within warranty period for
acceptance of materials
14 Providing,fixing and laying of fallowing dia HDPE pipe (medium
class) in ground complete with fitting incl. trenching(75 mm
depth)and refilling as per direction of Engg.-in-Charge. Ncessary test
report & Warrnaty certificate to be submitted to the department for
genuinity of product & to avail free after sales service within warranty
period for acceptance of materials
15 S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical
type timer panel with 32A 4P MCB ,40A TP CONTACTOR ,TIMER
with 15 nos 10A SP MCB C as per direction of Engg.-in-Charge.
.(Equievalant model each item of Legrand/Schneider/L&T/ABB or
equievalant make & model)Ncessary test report & Warrnaty Set 2.00 24832.64 49665.28
certificate to be submitted to the department for genuinity of product
& to avail free after sales service within warranty period for 2 years
after acceptance of materials.
R (LIGHTENING CONDUCTOR)
1 AIR TERMINAL & ACCESSORRIES LIGHTNING ARRESTER+
Providing and fixing of lightning conductor finial made of 25 mm dia
300 mm long, G.I tube,having single prong at top, with 85 mm dia 3
mm thick G.I base plate including holes etc complete as required
with as per direction of Engg.-in-Charge.(RATE REFERING OSR
2018 SOR NO-4.2) .The entire LA system should be
Replacement Warranty will be 5 years
2 Reveting, sweating and soldering of copper / G.I. tape ( with another
copper / G.I. tape, base of the finial or any other metallic object) as
required .as per direction of Engg.-in-Charge. (RATE REFERING mtrs 100.00 152.32 15232.00
OSR 2018 SOR NO-4.4) The entire LA system should be
Replacement Warranty will be 5 years
3 Providing and fixing of G.I. tape 20 mm x 3 mm thick on parapet or
surface of wall for lightning conductor complete as required. (For
horizontal run) as per direction of Engg.-in-Charge.(RATE mtrs 100.00 63.84 6384.00
REFERING OSR 2018 SOR NO-4.7) The entire LA system
should be Replacement Warranty will be 5 years
4 Providing and fixing of G.I. tape 20 mm x 3 mm thick on parapet or
surface of wall for lightning conductor complete as required. (For
virtical run) as per direction of Engg.-in-Charge. (RATE REFERING mtrs 80.00 105.28 8422.40
OSR 2018 SOR NO-4.8) The entire LA system should be
Replacement Warranty will be 5 years
5 Providing and fixing of testing joint, made of 20 mm x 3 mm thick
G.I. strip, 125 long with 4 nos of G.I. bolts, check nuts and spring
washer etc complete as required as per direction of Engg.-in-Charge.
(RATE REFERING OSR 2018 SOR NO-4.12) The entire LA system
should be Replacement Warranty will be 5 years
6 Providing and laying of G.I. tape 32 mm x 6 mm from earth electrode
directly in ground as required as per direction of Engg.-in-Charge.
.(RATE REFERING OSR 2018 SOR NO-4.14) The entire LA mtrs 16.00 101.92 1630.72
system should be Replacement Warranty will be 5 years
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
7 Maintenance free Safe Earthing
Electrodes with ISI G.I. pipe dia 75mm as Secondary electrode with
wall thickness of 2.6 mm and the Primary Earthing Electrode will be
50mm X 6mm X 1no M.S. hot dipped galvanized strip filled with a
highly conductive & non-corrosive compound in between the Primary
Earthing and the secondary Earthing, the Surface Area in will be
7,06,500sqmm for 3mtrs length and Cross Sectional Primary
conducting area is 300 sq.mm. An Solid G.I. Base plat seals the unit
at the bottom. as per direction of Engg.-in-Charge. SET 2.00 15631.84 31263.68
(MES-GFC ground Filling compound will be provided in 25 kgs
Bags.)(MES-GFC ground Filling compound will be provided in 25 kgs
Bags.)(2 bags required for each earthing electrode.)(FOR lightening
protection & Building Electrification).The entire earthing syste
with SA bracket internal JB with 4 way connector and MCB as
per the pole drawing and direction of EIC against which
AIR CONDITIONER
Supply of A,C with indoor and outdoor unit(make-Hitachi/Daikin)
1.1 1.5 TR high wall split A.C Each 10.00 52626.56 526265.60
1.2 2 TR high wall split A.C Each 4.00 57792.00 231168.00
1.4 1 TR high wall split A.C Each 4.00 37236.64 148946.56
REFRIGRANT PIPING
Supply,installation of hard/soft copper refregrant
piping,complete with fitting of bends and other nesessary
material to complete the job.
2.1 1 TR to 3 TR high wall split A.C mtr 199.00 938.56 186773.44
Supply,installation & fabrication of MS base frame for both
3.1 indoor and outdoor unit and other nesessary material to
complete the job.
3.1 1 TR to 3 TR high wall split A.C no 61.00 1883.84 114914.24
Supply,installation & fabrication of Insulated drain water piping
from indoor to nearestdrain point separate to all and other
nesessary material to complete the job.
SHEET METAL WORKS
Supply,laying of control cable and other nesessary material to
complete the job.
6.1 For 1 TR to3 TR high wall split A.C mtr 60.00 137.76 8265.60
TESTING AND COMMISSIONING OF AIR CONDITION
7.1 1-1.5 TR high wall split A.C Each 24.00 3625.44 87010.56
7.2 2-3 TR high wall split A.C Each 24.00 3625.44 87010.56
Supply,installation & fabrication of BASE FRAME for AC ODU
other nesessary material to complete the job.
A PUMPS AND APPURTENANCES
1 Supplying, installation, testing and commissioning of electric driven
pressurisation pump suitable for automatic operation and consisting
of following, complete in all respects, as required : (Jockey Pump)
Horizontal type, multistage, centrifugal pump of cast iron body and
bronze impeller with stainless steel shaft, mechanical seal
conforming to IS : 1520.
Suitable HP squirell cage induction motor TEFC type suitable for
operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of
protection for enclosure, horizontal foot mounted type with Class-'F'
insulation, conforming to IS : 325. M.S.fabricated Common base
plate, coupling, coupling guard, foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered and with anti
vibration pads.
B PIPE & VALVES ETC.
2 Supply,Installation,Testing & Commissioning of 'C' Class heavy duty
MS pipe (as per IS 1239 upto 150 mm NB and IS 3589 for above
150 mm 6mm thick) with flanges and fitting such as bends, tees,
reducers, rubber insertions and galvanized nuts and bolts of
following size on surface along wall / shaft with MS bracket,
suspended from ceiling/ beam with suspenders duly painted with two
coats of primer and finished with enamel paint of approved colour
laid through pipe or in trench after wrapping with hassen cloth after
applying coal tar primer as required as per direction of Engineer-in-
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
3 Providing laying, testing & commissioning of 'C' class heavy duty MS
Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees,
flanges, tapers, nuts bolts, gaskets etc. in ground including welding,
excavation & providing cement concrete blocks as supports,
anticorrosive treatment with coaltar/asphalt tape as per IS 10221,
refilling the trench etc. of following sizes complete as required.
4 Providing, fixing, testing and commissioning of following size
manually operated hand lever type cast iron double flanged slim seal
wafer type Butterfly valves with EPDM iron disc as per IS-13095
having pressure ratting PN -1.60 including fixing the same with
supply of required jointing materials like rubber insertion, MS nuts &
bolts, paint etc. and testing the joints with required water pressure
etc. all complete as per specification & direction of E.I.C.
5 Providing, fitting & fixing of following size cast iron double flanged
type dual plate Non return Valve as per IS- 5312 (Part 1): 2004 with
ISI mark of pressure ratting PN-1.60 including fixing the same with
supply of required jointing materials like flanges, rubber insertion,
MS nuts & bolts, paint etc. and testing the joints with required water
pressure etc. all complete as per specification & direction of
Engineer-in-charge.
Supply,Installation,Testing & Commissioning of Pressure gauge of 0-
16 Kgf/sq.cm. range with cut-off bronze ball valves of suitable size Nos 2.00 2332.96 4665.92
with all accessories as per direction of Engineer-in-charge.
7 Supply,Installation,Testing & Commissioning of Pressure Switch with
cut-off bronze ball valves with integral strainer & flare nut (mixed
ends) of suitable size with all accessories as per direction of
Engineer-in-charge.
8 Providing, installation, testing and commissioning of stainless steel Y-
strainer fabricated out
of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia
holes with stainless steel flange
C WET RISER CUM DOWN COMER SYSTEM
9 Supplying and fixing single headed internal hydrant valve with
Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel
ISI marked conforming
to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and
chain as required :
10 Supply,Installation,Testing & Commissioning of SS short branch pipe
with 63 mm male inlet and 19 mm outlet nozzle, as per IS:903 and Nos 2.00 2866.08 5732.16
as per direction of Engineer-in-charge.
11 Supply,Installation,Testing & Commissioning of 63 mm NB and
15meter long RRL Fire Hose fitted 63mm intstantaneous stainless
steel male & female SS coupling, complete by GI wire binding for Nos 6.00 5953.92 35723.52
Internal Hydrant as per direction of Engineer-in-charge.
12 Providing supply & fixing of MS Hose Box for of suitable
size(750X600X250mm) to accomodate 2 nos. of 15/ 1 no of 30 mtr
long fire hose and a branch pipe, wall mounted type as per direction
of Engineer-in-charge.
13 Supply,Installation,Testing & Commissioning of Swinging pattern wall
fixing first aid hose reel made from MS sheet and waterways and
moving parts with rubber hose of 20 mm dia. and 30 mtrs. long with
ABS(Plastic) shut-off nozzle as per IS: 444/IS: 12585 Type-I.,
complete with all accessories as per direction of Engineer-in-charge.
14 Providing, fitting and fixing of C.I. 25 MM single air relief valve with
stop cock confirming to IS:14845/2000 with ISI mark for water works
purpose including fixing the same with hydrant riser including testing
& commissioning the system etc. all complete as per approved
specification & direction of Engineer-in-charge.
15 Providing, fitting & fixing of 2-Way GM fire brigade connection
consisting of 63 mm dia instantaneous type male couplings with built-
in check valves, 150mm dia flanged outlet complete with bolts, nuts
and rubber insertions confirming to IS:903 with ISI mark including
testing & commissioning the system etc. all complete as per
apporoved specification & direction of EIC.
D EXTINGUISHER SYSTEM
Sl No. DESCRIPTION UNIT QNTY RATE AMOUNT
16 Portable Fire Extinguisher System Supplying, installation, testing and
commissioning of CO2 type Fire Extinguisher 4.5 kg capacity
confirming to IS: 2878 made from ISI marked seamless cylinder
confirming to IS: 7285, fitted with ISI marked controlled valve Nos 1.00 11677.12 11677.12
confirming to IS: 3224, high pressure 1mtr discharge hose & horn
complete with initial gas charged with carrying handle & wall
mounting bracket as per direction of Engineer-in-charge.
17 Supplying, installation, testing and commissioning of ABC type fire
extinguishers of 6 kg capacity including cost of all material & labour Nos 12.00 4979.52 59754.24
E FIRE SIGNAGES SYSTEM
Providing and installing in position the following type of sign boards
made out of 3mm thick "Opaque" PVC foam board with computer
cut, PVC non-reflective self adhesive vinyle painted foam board,
complete with mirror fasteners.
Floor indentification signage ( ie, GROUND FLOOR …etc.) at each
stair enclosure on every floor, indicating the floor number in words,
lettering size shall be 7.5 cm with contrasting colour from back
ground.Size shall be 15cm x 60cm.
Providing and fixing the signages "Fire Exit, Fire Exit Arrow
Down,Fire Exit Arrow Left,Fire Exit Arrow Right" of 1.5in height letters
in white with green back ground.The size of the board shall be 25cm
x 15 cm and shall be fixed at the height of 2 mts
Providing and fixing the signages "In case of fire pull down - with
Manual call point symbol ". Size 6" x 8"
Providing and fixing the signages "Main fire alarm panel." Size 6" x
Providing and fixing the signages "In case of fire, Do not use Lift,
Use Stair - with symbol." Size 8" x 8"
g Illumination Glow light for Exit Indication with Battery Back-up. Nos 1.00 10289.44 10289.44
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
REV NIT_58.pdf
Tender Document
FINAL BOQ.pdf
Tender Document
GCC with 12 Amendments.pdf
Tender Document
SCC.pdf
Tender Document
Signed IP.pdf
Tender Document
Drawings.pdf
Tender Document
Mile stone.pdf
Tender Document
APPROVED MAKES REV UPDATED.pdf
Tender Document
GCC Amendments 13 and 14.pdf
Tender Document
addendum-ae90e08f1856-ADDENDUM01.pdf
pdf • 0.15 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .