| Sl No | Description | Qty | Unit | RATHER BROTHERS L1 | patriotic builders L4 | M/S S. D. BUILDERS L3 | M/S GHULAM AHMAD BABA L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of brick work or stone masonry built in cement mortar including all quoins, pillars, arches etc. but excluding ashlar facings, dressed stone work and precast concrete articles, complete all as specified and as directed. | 10 | Cum | 250 ₹2,500 | 200 ₹2,000 | 450 ₹4,500 | 150 ₹1,500 |
| 2.00 | M&L brick work with sub class 'B' bricks of old size, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 complete all as specified and as directed. | 8 | Cum | 6,000 ₹48,000 | 9,500 ₹76,000 | 9,500 ₹76,000 | 8,500 ₹68,000 |
| 3.00 | All as per srl Item No 2 above but except brick. | 2 | Cum | 2,000 ₹4,000 | 2,000 ₹4,000 | 3,900 ₹7,800 | 2,000 ₹4,000 |
| 4.00 | Taking down cement plaster on brick or stone wall etc. including racking out joints, hacking for key and scrubbing down with water etc. complete all as specified and as directed. | 250 | Sqm | 40 ₹10,000 | 10 ₹2,500 | 49 ₹12,250 | 20 ₹5,000 |
| 5.00 | M & L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished over and smooth w/o using extra cement complete all as specified and as directed. | 100 | Sqm | 300 ₹30,000 | 300 ₹30,000 | 215 ₹21,500 | 300 ₹30,000 |
| 6.00 | M & L for rendering 15mm thick on stone masonry concrete surfaces or other than fair faces of brick work or on one side of lathing in CM 1:6 finished over and smooth w/o using extra cement complete all as specified and as directed. | 150 | Sqm | 250 ₹37,500 | 300 ₹45,000 | 210 ₹31,500 | 350 ₹52,500 |
| 7.00 | M&L PCC 1:2:4 type B-1 in kerb or mud stops rounded or chamfered on edges all as specified (20mm graded aggregate) for copping, including weathering slightly rounded or chamfered using form work straight or curved complete all as specified and as directed. | 1 | Cum | 6,500 ₹6,500 | 7,500 ₹7,500 | 8,900 ₹8,900 | 5,500 ₹5,500 |
| 8.00 | M & L applying two coats of cement base paint including preparation of newly plastered surface of wall complete all as specified and as directed. | 100 | Sqm | 55 ₹5,500 | 40 ₹4,000 | 39 ₹3,900 | 55 ₹5,500 |
| 9.00 | M & L applying one coats of cement base paint including preparation of old plastered surface of wall complete all as specified and as directed. | 400 | Sqm | 35 ₹14,000 | 30 ₹12,000 | 28 ₹11,200 | 65 ₹26,000 |
| 10.00 | M & L applying two coats of Oil bound distemper including preparation of newly plastered surface of wall over 3mm call care putty complete all as specified and as directed. | 150 | Sqm | 65 ₹9,750 | 40 ₹6,000 | 65 ₹9,750 | 45 ₹6,750 |
Updated dates
Tender Value
Refer Docs
EMD Value
₹95,210
Closing Date
18 Feb 2026, 6:00 pmClosed
GE 874 EWS
GE 874 EWS C/O 56 APO
SPL REP TO BLDG NO P-92 AND UNDER GROUND ELECTRIC CABLE AT NIYARI AND TANGDHAR UNDER THE AOR OF GE 874 EWS
2026_MES_748939_1
GE 874/EWS-75/2025-26
Open Tender
Civil Works
180 days
KUPWARA
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
SBI BARAMULLA
₹95,210
15 Apr 2026
17 Jan 2026
20 Feb 2026
17 Jan 2026
18 Feb 2026
5 Feb 2026
Demolition of brick work or stone masonry built in cement mortar including all quoins, pillars, arches etc. but excluding ashlar facings, dressed stone work and precast concrete articles, complete all as specified and as directed.
M&L brick work with sub class 'B' bricks of old size, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 complete all as specified and as directed.
All as per srl Item No 2 above but except brick.
Taking down cement plaster on brick or stone wall etc. including racking out joints, hacking for key and scrubbing down with water etc. complete all as specified and as directed.
M & L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished over and smooth w/o using extra cement complete all as specified and as directed.
M & L for rendering 15mm thick on stone masonry concrete surfaces or other than fair faces of brick work or on one side of lathing in CM 1:6 finished over and smooth w/o using extra cement complete all as specified and as directed.
M&L PCC 1:2:4 type B-1 in kerb or mud stops rounded or chamfered on edges all as specified (20mm graded aggregate) for copping, including weathering slightly rounded or chamfered using form work straight or curved complete all as specified and as directed.
M & L applying two coats of cement base paint including preparation of newly plastered surface of wall complete all as specified and as directed.
M & L applying one coats of cement base paint including preparation of old plastered surface of wall complete all as specified and as directed.
M & L applying two coats of Oil bound distemper including preparation of newly plastered surface of wall over 3mm call care putty complete all as specified and as directed.
M & L applying one coats of oil bound distemper including preparation of old plastered surface of wall complete all as specified and as directed.
Dismantling plain or corrugated steel sheeting any gauge thickness in roof covering.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
All as per srl item No 13 above but plain sheet as in roof covering /cladding to wall fixed with tapping screws
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for Non - skid coloured Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:4 complete all as specified and as directed.
S & F Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match in skirtings/dados etc including 15mm thick rendering in CM 1:4 complete all as specified and as directed
S & F Double charged dark shade Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:4 complete all as specified and as directed.
All as per srl item no 18 above but as in skirting/dado.
Dismantling of boarding, any description, fixed in any position with nails complete all as specified and as directed.
M & L for 2nd class Clean sawn battens at 30 cm centre to centre of sectional area of 5 but not exc 15 sqcm complete all as specified and as directed.
S&F Eaves Boarding of 20mm thick of Softwood 2nd class with nails in any situation (except flooring and skirting) , planed one side with butt joints complete all as specified and as directed.
S& F 12mm Plywood, grade BWR, type BB of 7 ply fixed with screws to timber frame work complete all as specified and as directed.
S & F 12mm thick Veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face; fixed with nails to timber frame work on ceiling complete all as specified and as directed.
M & L for 2nd class soft wood moulding as in cornices, picture rails and like, not exc 6 Sqcm in section, wrought fixed with nails complete all as specified and as directed.
M & L for 5mm PVC panelling for wall/ceiling of any shade including PVC framework as approved complete all as specified and as directed.
M&L for 6mm thick E board (classic) of size 610x610mm as in false ceiling fixed with aluminium snap grid frame work of same size as aluminium Tee of size 25x25x1.50mm as main runner, 25x25x1.25mm thick aluminium Tee as cross runner and aluminium angle of size 25x25x1.25mm at the perimeter including Gl 6mm adjustable suspender of required length of any description complete all as specified and as directed. Note: The design and specification of the ceiling board to be approved by GE.
Taking down chowkhats or frame exc 1.5 Sqm and n exc 4 sqm sqm each with shutter (W/o taking off shutter from frame) complete all as specified and directed.
Taking down chowkhats or frame not exc 1.5 sqm each (without taking off shutter from frame) complete all as specified and as directed.
Taking down Shutters of any description exc 1 sq. m but n exc 2 qm each complete all as specified and as specified and as directed.
S&F for 2nd class soft wood, plain, solid, straight chowkats or frames, wrought framed rebated on the solid, rounded or chamfered, put together with flue pinned at joints complete all as specified and directed.
S&F for 35mm thick, plain framed panelled shutter (any number of panel) with panel of timber flat on both sides (feather edged) or of veneered particle board medium density, wood particle board with commercial face veneers supplied and fitted to chowkhats 35mm thick second class soft wood (Kail) complete all as specified and directed.
S&F 35mm thick, 2nd class soft wood, Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
S & F solid PVC door frame of size 50mm x 47mm made out of 5mm prelaminated PVC sheet, reinforced with M.S. square tube and fixing in opening as per specification & drawing complete all as specified and as directed.
S&F factory made solid PVC moulded door shutters with particle board core 28 to 30 mm thick 9styles) with 2, 4, or 6 raised panel design with 2 mm thick prelaminated moulded PVC sheet on the front face and 2mm thick plain colour PVC sheet on back face fixing in frame with wood free EPS at site as per specification and drawing complete all as specified and directed.
S&F Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc, over Powder Coating to (minimum thickness of powder coating 50 micron) complete all as specified and directed.
S & F powder coated anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed.
S& F double action floor spring, hydraulically regulated, made up of 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and as directed.
M&L for 12 mm thick prelaminated particle board interior grade prelaminated both side with decorative choice lamination fixed with screw to timber frame work/aluminium frame work complete all as specified and directed.
S& F 100mm long mortice latch with two levers (vertical type), brass body complete all as specified and as directed.
M&L for 5.5 mm thick tinted glass fixed to aluminium frame including rubber bead complete all as specified and directed.
Supply and fixing steel window box type using ERW hollow 'P' section comprising double frame for and including gauged and glazed Skelton shutter 30mm thick, jointed internally with flat iron 25x3mm complete including hinges, handle, tower bolts, stops, lugs, guard bars and painting etc. all as shown on drawing No. CESZ /TD-1018 sheet 1/3 to 3/3 and CESZ /TD-1019 sheet 1/3 to 3/3 (latest revised) as applicable complete all as specified and as directed. Note: (i) For the purpose of measurement and payment double shutter both glazed and gauzed with frames shall be considered as one unit. (ii) Unit rate quoted against this item shall also include the iron mongry and grill as shown on drgs. (iii) Glazing, wire mesh shall be measured and paid separately.
S & F 12mm thick fibre insulation boards, flame retardant type, treated on one face only including all fixing framework complete all specified and as directed.
S & F 250 mm long aluminium alloy anodized sliding door (boil type) and fixing clips of sheets cast of extruded sections and fixing bolts and sliding bolts of extruded section of cast-aluminium alloy complete all as specified and directed.
S&F pre-coated sheet type door spring, heavy type, 300 mm long including roller and roller plate complete all as specified and directed.
S&F 2nd class hard wood small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary labours, articles n exc 200 cu. cm each complete all as specified and directed.
S & F Mild Steel butt hinges 100mm long medium weight complete all as specified and directed.
S & F 200mm long aluminium alloy, anodized barrel tower boll of extruded section complete all as specified and directed
S & F aluminium handles, cast type, anodized 150mm long complete all as specified and directed.
S&F for 75mm long mild stee butt hinges medium weight cold rolled complete all as specified and directed
S&F for 150mm length aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F Aluminium handle, cast type, anodised 100 mm long complete all as specified and directed.
M & L for sheet glass ordinary quality and glazing with oil putty in square n. exc 0.5 in each pane, 3mm thick complete all as specified and directed.
S&F galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm including fixed complete all as specified and directed.
M & L two coats of synthetic enamel paint over a priming coat with red oxide over steel surface over 10 cm width or girth complete all as specified and directed.
M & L one coats of synthetic enamel paint over steel surface over 10 cm width or girth complete all as specified and directed.
M & L for applying two coats of synthetic enamel paint over a coat of pink primer including preparation of new wooden surface exc 10 cm width or girths complete all as specified and directed.
M & L for applying one coats of synthetic enamel paint over a coat of pink primer including preparation of new wooden surface exc 11 cm width or girths complete all as specified and directed.
S& F in repair stainless steel curtain road of 25mm dia of 0.80 mm to 1mm thickness including brackets, stops, roller etc complete all as specified and as directed.
Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M &L for providing reinforced cement concrete 1:2:4 type B-1 (20mm graded aggregate) (nominal mix) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) as in flat complete all as specified and directed.
S & F for mild steel TMT bars 10mm dia and over cut to length, bent to shape required including cutting, cranking, hooking ends and binding with mild steel wire (annealed not less than 0.90mm dia) complete all as specified and directed.
M & L for cutting chases, pinning in making good to facing where required and pointing in CM 1:3 to edges of landing, steps, cills, sunshades, shelves, lintel etc. and cutting chases for concealed water tubing etc and making good cutting n. exc 10 cm girth complete all as specified and directed.
M & L for 15mm bore `Medium grade` GI tubing with all fitting and fixed complete to walls and ceilings or laid in floors including taking down existing tubing complete all as specified and directed.
M & L for 20mm bore `Medium grade` GI tubing with all fitting and fixed complete to walls and ceilings or laid in floors including taking down existing tubing complete all as specified and directed.
M & L for 15mm Lagging to pipes used in internal water supply or plumbing all round with, 25min thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842 complete all as specified and as directed.
M & L for 20mm Lagging to pipes used in internal water supply or plumbing all round with, 25min thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842 complete all as specified and as directed.
S&F in repair bib taps long body 15mm dia Chromium Plated, fancy type screwed down for iron pipe and fixed complete all as specified and as directed by the Engr-in-charge.
S & F in repair ISI marked fancy type Pillar Tap of 15mm bore dia, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S & F in repair of ISI marked 15mm bore stop valve, fancy type chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, complete all as specified and directed.
S & F in repair brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed.
S&F in repair 32 mm dia PVC waste pipe for wash hand basin / Kitchen sink etc complete all as specified and directed.
S & F in repair 15mm thick PVC connection with PTMT nuts of length 600mm complete all as specified and directed.
S&F in repair Central Hole Basin Mixer without Popup Waste System with 450mm Long Braided Hoses complete all as specified and directed.
S&F in repair Towel Rack 600mm Long with Lower Hangers, Stainless Steel including brackets complete all as specified and directed.
S&F in repair CP SOAP DISH HOLDER including fixing with brass screws to wall complete all as specified and directed.
S & F in repair Long Body Bib Cock with Wall Flange complete all as specified and directed.
S & F in repair Angular Stop Cock with Wall Flange complete all as specified and directed.
S&F in repair Glass Shelf 600mm Long (with bracket) including fixing with brass screws to wall complete all as specified and directed.
S&F in repair Single Piece WC with PP soft close seat cover, Hinges, Fixing Accessories and Accessories Set, Cistern fittings, Size: 370x690x680 mm including S trap-300mm complete all as specified and directed. Note: The contractor shall produce warranty from manufacturer before claiming payments.
S&F in repair Wall Hung Basin with full pedestal with Fixing Accessories, Size: 620x480x185 mm with chromium plated waste coupling, waste pipe, PVC connection and all connected fittings complete all as specified and directed.
S & F in repair for 15mm bore stop valves, fancy type chromium plated with long shank and cup (concealed) type complete all as specified and directed.
S&F in repair chromium plated shower rose 125 mm size with or without swivel joints any size including to fixing to steel pipe or union complete all as specified and directed.
S&F in repair Vitreous China urinal, half stall type white (excluding flushing cistern, flush pipe) including PVC waste pipe , providing and fixing plugs bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe,(exclusive of fixing supply pipe to flushing cistern trap and waste pipe) complete all as specified and directed.
S&F in repair Hand Shower (Health Faucet) with 1 Meter Long Easy Flex Tube in Chrome Finish & Wall Hook with all connected fittings complete all as specified and directed.
S&F in repair toilet paper holder with flat recessed type stainless steel Complete all as specified and directed.
S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors including dismantling of existing pipes complete all as specified and directed.
S & F 110mm bore PVC (SWR) bends of any radius, complete all as specified and directed.
S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls including dismantling of existing pipes complete all as specified and directed.
S & F 75mm bore PVC (SWR) bends of any radius, complete all as specified and directed.
M & L for 1000 Litres rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including dismantling water tanks exc 250 but not exc 500 litres complete all as specified and directed.
S & F of for ISI Marked 20mm dia Ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and directed.
S& F in repair 15mm Gun-metal, globe or gate valves, with iron wheel head, crewed both ends for iron pipe and fixed complete all as specified and directed.
S& F in repair 20mm Gun-metal, globe or gate valves, with iron wheel head, crewed both ends for iron pipe and fixed complete all as specified and directed.
S&F for in repair stainless steel sink without drainage board made of stainless steel 1 mm thick sheet for kitchen with waste coupling waste pipe, washer and including all necessary item including fixing to brackets and connected union to pipe complete of overall size 495 x 420 mm with bowl size 410mm x 330mm x 160mm complete all as specified and directed.
Demolition of Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M&L for cement concrete 1:3:6 type C1 (using 20mm stone aggregate as in plinth protection), 75mm thick complete all as specified and directed.
Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings, removing material from site for taking credit etc and making good disturbed surfaces of wall, floors, complete all as specified and directed.
Taking down MCB DB's complete with MCB's/Isolator etc removing materials from site and making good disturbed surface of walls, floors etc complete all as specified and directed.
Disconnecting unserviceable sub main wiring/service connection of any size and including steel conduit and accessories and removing from site and making good the disturbed surfaces complete all as specified and directed.
M & L for point wiring One light /one fan/one bell point controlled by one switch, with PVC insulated unsheathed single core multistranded copper conductor 1.5 sqmm, 1100 volts grade cable, FRLSH, drawn through PVC casing caping including accessories and provisioning of PVC boxes suitable for mounting modular switch, socket, fan regulator, No of modules as required on site or as directed by Engineer-in-Charge including one run of PVC insulated unsheathed multistranded copper conductor cable 1.5 sqmm (green colour) as earth wire and connected to earth dolly including colour coding for phase, earth & neutral complete all as specified and directed.
All as per item No 103 here in before but wiring with 1.5 sqmm copper wire (FRLSH) and 1.5 sqmm earth wire for socket outlet 3 pin 5 amps on independent board.
All as per item No 103 herein before but wiring with 2.5 sqmm copper wire (FRLSH) and 2.5 sqmm earth wire for socket outlet 6 pin 15 amps on independent board.
All as per item No 103 herein before but wiring with 4 sqmm copper wire (FRLSH) and 2.5 sqmm earth wire for socket outlet 6 pin 15 amps on independent board.
All as per item No 103 herein before but wiring with 1.5 sqmm copper wire (FRLSH) and 1.5 sqmm earth wire for socket outlet 3 pin 5 amps on same board.
S&F Switch socket combination 5 in 1, 5 and 15 Amp modular type universal controlled by one switch (ISI Marked) complete all as specified and directed.
S&F socket outlet 2-in-1, 3 pin, 6 Amps modular type (ISI Marked) complete all as specified and directed.
S&F Switch socket combination 2-in-1 5 pin 6 Amps modular type (ISI Marked) complete all as specified and directed.
S&F modular type Switch piano 6 Amps single pole one way, complete all as specified and directed.
S&F ceiling rose surface Bakelite 65x50mm two to three terminals (ISI Marked) complete all as specified and directed.
S&F LED, 20 Watts, 4 ft, fittings complete with all accessories for mounting light fittings complete with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body complete all as specified and directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
M & L for lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Supply and fix LED Bulb 9 Watt complete all as specified and directed.
S&F in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 4 core complete all as specified including removing unserviceable UG cable complete all as specified and directed.
M & L for sub main wiring with two single core 6 sqmm PVC insulated and unsheathed 1100 volts grade, stranded copper conductor FRLSH ISI marked drawn into & including medium grade PVC conduit 25 mm dia with all fittings and accessories and one continuous run of 6 sqmm copper conductor PVC insulated (green colour) as earth wire fixed into PVC conduit (not less than 25mm outer dia) with all fittings and accessories fixed concealed/ surface including taking down old unserviceable submain wiring and making good to disturbed surface of wall matching with existing complete all as specified and directed.
S&F building security light fitting in repair LED 35 Watt for Energy saving and environmental friendly long life made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP66 protection and Impact resistance of IK07 including driver unit and bracket made up of GI tube of suitable size (1.2 Mtr Length) etc complete all as specified and directed.
S & F in repair DB with sheet metal enclosure 415 volts, 4 way with rated bus bar Three pole & neutral (TPN) double door including fixing on suitable rectangular block complete all as specified and directed.
Supply and Fix in repairs MCCB Metal enclosures, MCCB Four Pole 100 Amps 415 Volts 16KA fixing in Metal enclosure, in wall mounted type complete with all accessories, including taking down of old Unserviceable main switch and reconnecting the cables with proper complete all as specified and directed.
S&F of distribution board single pole & neutral with 200 Amps rated bus bar, for double door IP-42 DB's, made out of sheet steel enclosure, recessed type, factory made powder coated 12 way -240 volts suitable for housing MCB's and isolator's complete in all fixing material/accessories/flush to the wall etc complete all as specified and directed.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single poles Neutral (SPN) 32-63 Amp and current carrying capacity in the MCB DB complete with connection testing and commissioning.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single poles (SP) 10-32 Amp and current carrying capacity in the MCB DB complete with connection testing and commissioning.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0 mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 03 of 2009 SSR Pt-I and testing on complete including earth work in any type of soil, PCC 1:2:4 type B-0 as in earth pit and cover 40mm thick reinforced with XPM (weight not less than 4.0Kg/Sqm) and frame of angle iron of size 25x25x3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, common salt, charcoal and testing on completion all as specified and directed.
Excavation in trenches not exc.1.5 mtr wide and not exc.1.5 m in depth for foundation of poles, stay assembly and laying of LT/HT cable as in any type of soil and getting out, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed by Engineer –in- Charge at a level not exceeding 1.5mtr above the starting point complete all as specified and directed.
M&L for sand cushioning for protection of PVC cable with approved sand of uniform thickness, laid dry, by filling in trenches and punning to proper required cover complete all as specified and directed.
Supply and laying of fly ash bricks of best quality laid flat equal to width of bricks, perpendicular to UG cable over the dry sand cushioning, for cable protection complete all as specified and directed.
S&F for drilling suitable dia horizontal bore holes for insertion / laying of up to 50 mm bore GI tubing of any description below/under road surface/floors etc with using mechanical or manual devices as required at site including making good disturbed surface to match with the existing strata after laying pipes complete all as specified and directed.
Dismantling of old unserviceable ACSR conductors from existing PCC/RCC/Steel poles complete all as specified and directed.
Dismantling of old unserviceable insulators any type & any size from pole (PCC/RCC/Steel) complete all as specified and directed.
Dismantling of Cross arms of MS channel or angle section etc complete all as specified and directed.
Dismantling GI earth wire/ old unserviceable guarding complete all as specified and directed.
Supply and Laying, jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor ,1100 volts grade, cross section area 10 Sqmm 2 core complete laid in trenches, ducts or fix to pipe, on walls, poles complete all as specified and directed.
Supply and Laying, jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor ,1100 volts grade, cross section area 16 Sqmm 2 core complete laid in trenches, ducts or fix to pipe, on walls, poles complete all as specified and directed.
Supply and Laying, jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor ,1100 volts grade, cross section area 25 Sqmm 3.5 core complete laid in trenches, ducts or fix to pipe, on walls, poles complete all as specified and directed.
Supply and Laying ,jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor ,1100 volts grade ,cross section area 50 Sqmm 3.5 core complete laid in trenches, ducts or fix to pipe, on walls, poles complete all as specified and directed. Note for srl item No 136 to 139 :- Excavation and earth work shall be measured and paid separately.
Excavation in trenches n. exc.1.5m wide and n. exc. 1.5m in depth for foundation laying of pole, stay assembly and laying of LT cable as in any type of soil and getting out complete all as specified and directed.
All as item No 3 Above but depth beyond 1.5m deep, for poles.
Returning filling in including spreading, levelling, watering and wall ramming in layers not exc 25cm in any type of soil complete all as specified and directed.
Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and directed.
Sand cushioning to underground cables 8 cm below the cable before laying and 15cm above the cable after laying complete all as specified in clause 19.75 of SSR Part-I.
M&L for Brick for burnt sub class 'B' bricks laid dry, flat, width wise along the length of cable in trenches after sand cushioning for protection of under ground cable complete all as specified and directed.
M&L for GI pipe light grade 50 mm for cable protection as a guard pipe including required accessories etc. complete all as specified and directed.
M&L for mild stel cross arms bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint after preparation of surface, including taking down unserviceable/old cross arms complete all as specified and directed.
Supply and fixing for pin type, porcelain, vitreous, white or brown insulator including one galvanised mild steel spindle, one galvanised iron washers and one galvanised iron nut, 100 mm height, 65mm dia for 1100 (LT) volts grade. Including taking down old unserviceable pin insulator complete all as specified.
Supply and erect steel tubular swaged poles ISI marked complete with cast iron base plate, final taper plug, bolts, nuts and screw drilling of holes for continuous GI earth wire as specified type 410-SP-31 (09 mtr long) including applying two coats of aluminium paint over one coat of red oxide zinc chrome primer after preparation of surfaces. complete, with one earthing after every three poles (on the third poles), complete all as specified and directed. (Note - Excavation earthwork and PCC shall be measured and paid separately).
Supply, installation connecting electrically and testing of street light junction box size 155x 210 x 92 mm, made out of thermoplastic and arrangement of incoming 3 Phase 4 wire system and outgoing 3 phase 4 wire system with R,Y,B & N studs and control for incoming & outgoing cables with MCB SP 6 Amp 23 Volts with Neutral link including Flat iron 25x3mm "D" Clamps (2 Nos) Suitable for pole of any size with bolts, nuts & washers complete all as specified and directed. Note : The Unit rate quoted shall be deemed to includes for incoming & outgoing cables glands & lugs of size up to 10 sqmm to 16 sqmm 2 core
S & F of two runs of single core of size 2.5 sqmm phase and neutral and one run of 1.5 sqmm for earth continuously drawn through steel tubular pole and connecting with proper copper terminals, including PVC Conduit for giving connection between looping box and light fitting complete all as specified and directed.
S & F for Rigid non-metallic PVC conduit 20mm dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. heavy duty wall thickness 2.00mm for street light fittings complete all as specified and directed.
S & F of Thimble of size 16 sqmm, 25 sqmm & 50 Sqmm Aluminum complete all as specified and directed.
Supply installation, connect, testing and commissioning of 3 phase 4 wire 50 Hz 440 volts out door type bus bar enclosure 0.9 x 0.9 x 0.4mtr size compartmentalised cubical type with canopy, dust and vermin proof free standing floor mounting type mounted on and including 1:3:6 PCC platform with required mounting channel feeder pillar box fabricated out of 3.15 mm thick CRCA steel sheet duly pre treated and powder coated factory fabricated including cable glands of suitable sizes and consisting of the following ;-
(a) Aluminium bas bar 200 amps - 04 Nos,
(b) Incoming TPN 100 Amp -01 Nos,
(c) Outgoing MCB SPN 32Amp - 03 Nos and supported with suitable size of heavy duty porcelain stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral.
Supply installation, connect, testing and commissioning of 3 phase 4 wire 50 Hz 440 volts out door type bus bar enclosure 0.9 x 0.9 x 0.4mtr size compartmentalised cubical type with canopy, dust and vermin proof free standing floor mounting type mounted on and including 1:3:6 PCC platform with required mounting channel feeder pillar box fabricated out of 3.15 mm thick CRCA steel sheet duly pre treated and powder coated factory fabricated including cable glands of suitable sizes and consisting of the following ;-
(a) Aluminium bas bar 100 amps - 04 Nos,
(b) Incoming TPN 63 Amp -01 Nos,
(c) Outgoing MCB SPN 32Amp - 03 Nos and supported with suitable size of heavy duty porcelain stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral.
Supply, installing, testing and commissioning, factory made and tested (prototype having been CPRI type test certified), LT Panel, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bars of Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, externally powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry, with double door shutter and locking arrangement (including provision of 65mm Godrej (Freedom) lock with 2 keys, internal wiring 2.5 Sqmm with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size including the provision of space to accommodate the under mentioned items. The scope of work includes the following:
(a) Aluminium bus bar of size 15x3mm and capacity 300 Amp- 04 Nos
(b) MCCB four pole with Adjustable thermal & Adjustable Magnetic type with breaking capacity 30KA, 250 Amp (incoming) -01 Nos
(e) LED Indicating Lamps - 01 Set of Three
(f) Secure 3 phase, 1 Element 4 wire 440V Digital Power factor meter - 01 Nos
(g) Current & Potential Transformer - 01 Set of Three
(h) MCCB 4 pole, 415 volts AC grade,100 Amps rating and 20 KA rupturing capacity complete with Adjustable Thermal & Adjustable Magnetic - 04 Nos
(j) Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class `B', old size bricks, rendering 15mm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level.
M & L for Cement concrete 1:2:4 type B-2 using 40 mm graded crushed stone aggregate as in coping of pole and stay assembly complete all as specified and directed.
M & L for cement concrete (1:4:8), D-2, using 40mm graded stone aggregate as in pole foundation and filling complete all as specified and directed.
M & L for cement concrete (1:3:6), type C-1 using 20mm graded stone aggregate as in bedding complete all as specified and directed.
M & L for earthing complete with galvanised steel earth plate electrode 60x60cmx 6.0mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel
including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4,funnel with wire gauge of (0.68) 8 mesh per liner inch,80mm thick RCC pit cover 320 mmx320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM,JALLI and charcoal dust and common salt all as shown in electrical plate No.3 of MES SSR Part-1 and specified including provision of earth wire protected by 40 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore medium graded GI pipe, and including all excavation and earth work & connecting the earthing to an earthing test point /transformer neutral/body/LT panel etc. and testing on completion complete all as specified and directed.
M & L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of
galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 03 of 2009 SSR Pt-I and testing on complete including earth work in any type of soil, PCC 1:2:4 type B-0 as in earth pit and cover 40mm thick reinforced with XPM (weight not less than 4.0Kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, common salt, charcoal and testing on completion, all as specified and directed.
M & L for painting to LT poles, 9 mtr with cross arms, bracing and clamps with one coat of synthetic enamelled paint over one coat of red oxide primer including scrapping the old paint carefully to make smoothen complete and painting strips of yellow and black from foot of pole upto 5 feet each strip of 30 cm height all as specified and directed.
Supply and fix air cooled split air conditioner unit indoor and out door electric driven, single phase of capacity of 2 TR, BEE 5 star rated (cooling and heating type split A/Cs) complete all as specified and directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA. complete all as specified and directed.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
technical_838732.pdf
techsummary_838732.pdf
finance_838732.pdf
BOQ Comparative Chart
xlsx
finsummary_838732.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.48 MB
Drawingsteelwindow.pdf
Additional Documents • 4.60 MB
BOQ_838732.xls
BOQ • 0.34 MB
75TENDER.pdf
Tender Documents • 1.89 MB
Download all tender documents and submit your bid