| 1 | L1₹5.7 LAccepted-AOC 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L1 | Accepted-AOC Being the lowest | |
| 2 | L2₹8.0 L+₹2.3 L (39.6%)Rejected-AOC | L2 | Rejected-AOC Not being the lowest |
Tender Value
₹9.1 L
EMD Value
₹18,200
Closing Date
9 Dec 2023, 6:00 pmClosed
AGE (I) AF Sonegaon, Nagpur
Bldg P-51, 44 Wings AF Station Sonegaon, Nagpur-440005
PROVN OF FLAME PROOF EXHAUST FAN, WIRING AND LIGHTING AND INSTALLATION OF AIRCONDITIONER AND FLOOD LIGHT AT AF STN SONEGAON, NAGPUR
2023_MES_627071_1
8487/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Sonegaon
As per NIT
8 documents required · 8 mandatory
₹500
AGE (I) AF Sonegaon
₹18,200
Yes
5 Jan 2024
6 Nov 2023
16 Dec 2023
6 Nov 2023
9 Dec 2023
20 Nov 2023
6 Nov 2023 - 13 Nov 2023
Amount
Supply and fix LED flood light luminaires of capacity 500W 230V Ac Outdoor type with thermal management in multiple optics and equipped with IP 66 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply and lay in trenches/drawn through pipes or in road crossings / paths/ drains / ducts / floors / along poles / equipments etc., of LT cable under ground, XLPE insulated, screened, PVC bedded, galvanised strip or wire armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade of cross sectional area 16 Sqmm 4 core including connecting up using suitable size aluminium lugs testing and commissioning complete all as specified and as directed. Note : Excavation earth work, sand cushioning and brick protection shall be measured and paid separately.
Excavation in trenches in soft/ loose soil n. exc. 1.50m wide and n. exc. 1.50m deep for foundation, or for shafts, wells, cesspits, manholes, etc., n. exc. 10 sqm on plan getting out complete all as specified and directed.
Removal of excavated materials to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
M & L for providing dry river sand as in sand cushioning for underground cable protection including punning down sand in layers complete all as specified & directed Note: Only punned thickness of sand shall be considered for measurement purposes
Supplying and laying common burnt clay sub class ‘B’ bricks of size 230 mm x 115 mm x 75 mm, laid perpendicular to axis of cable for protection of LT cables complete all as specified and directed.
M&L for ERW Steel conduit black stove enamelled of size 20 mm dia complete with flame proof conduit accessories like tee, bend, elbow or bell mouth reducer and making good the disturbed surfaces to match with the existing surfaces all as specified and directed.
M&L for submain wiring with two runs of 2.5 sqmm PVC insulated , FRLS, 1100 volts grade multistranded copper conductor drawn in steel conduit with one run of 2.5 Sqmm as earth continuity conductor drawn in ERW steel conduit all as specified. Note : (i) Conduit and conduit accessories shall be measured and paid separately under respective items. (ii) Two run of 2.5 sqmm and one run of 2.5 sqmm cable shall be measured as one unit.
M&L surface type point wiring for explosive storage acommodation with PVC insulated 1.5 sq mm multistranded copper conductor cable ,FRLS,1100 volt grade drawn in and incl surface mounted ERW stove enamelled , black steel conduit not less than less 20 mm dia with and including flame proof bends and elbows, couplers, bell mouth reducer except junction box all as per relevent IS fixed with solid baked distance saddles ,and elevated MS spacer plate fixed with nettle fold GI screws along with 1.0 sq mm PVC insulated solid strand copper conductor FRLS 1100 Volt grade as ECC connected to common earth dolly complete all as specified and directed.
(a) One light point controlled by one rotory switch.
(b) One ceiling/exhaust fan point controlled by one rotory switch.
(c) One three pin 5 Amps switch socket outlet on independent board
All as per item No.10 here in before but point wiring with 2.5.0 sqmm multistrandard copper cable for 5 Pin 15 Amp switch socket combination on Independent board with one run of 1.5 sq mm multistranded copper cable green colour for earth continuity conductor complete all as specified and as directed.
S&F flame proof ON/Off rotory switch of cast Aluminium alloy SP 10/16 A 240V in LM -6 all as specified and as directed.
S&F Flame proof DB 6way with MCB DP 32A Capacity Construction with cable entries at bottom/Top for Incoming & 4 no MCB 6 amp as outing circuit all as specified.
S&F flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+ earth complete all as specified and as directed.
S&F LED flame proof /weather proof light fitting suitable for 1X18/20watt LED tubelight fittings with built in control gear box as per relevant IS complete with accessories &1Nos of 18/20watt LED tuberod Complete all as specified and as directed. Make -: Shyaam switchgear Cat part no. SSPL/FF/1271/Sudhir/flexpro.
S&F Flame proof DB 6way with MCB DP 32A Capacity Construction with cable entries at bottom/Top for Incoming &2 no MCB 6 amp & 2 no MCB 16 amp as outing circuit all as specified.
S&F Flame proof DB 4way with MCB DP 16/25A Capacity Construction with cable entries at bottom/Top for Incoming &2 no MCB 6 /10amp & 2 no MCB 16 amp as outing circuit all as specified.
S&F flame proof /weather proof ceiling fan with regulator LM6 size 48'' as per relevant IS complete suitable for single phase 240VComplete all as specified. Make Shyaam Switchgear Cat part no. SSPL/CF/193-Ceiling Fan & SSPL/2C/1010 - Regulator/Sudhir/flexpro.
S&F flame proof /weather proof exhaust fan 12'' as per relevant IS complete suitable for single phase 0.25 HP, 1440 RPM, 1120 CFM, 240VComplete all as specified. Make Shyaam Switchgear Cat part no. SSPL/CF/193-Ceiling Fan & SSPL/2C/1010 - Regulator/Sudhir/flexpro.
M&L for point wiring complete with 1.5sqmm (nominal area) PVC insulated unsheathed multistranded, (two run for Phase and Neutral) copper conductor FR & LS grade cable of 1100V grade conforming to IS -694 drawn through and including new non metallic rigid PVC conduit medium grade, ISI marked, 20mm bore with conduit accessories concealed in wall/ floor and fixed on ceiling/ roof etc. including new pressed steel terminal boxes 1.6mm thick, concealed in walls with plastic laminated sheet cover 3mm thick as top cover fixed with cadmium plated screws for housing the switch sockets, outlets, fan regulator etc including provn of 1.5sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly etc., complete all as specified and directed for:-
One light/ fan/ exhaust fan point controlled by one switch.
Supply and fix LED tube light fitting capacity 20 watt fixed on wall/surface / ceiling with all accessories tube,driver,with surge protector complete wired with multistranded copper cable & connecting to ceiling rose with 3 core ,multistranded flexible copper cable complete all as specified and directed. Make CGCta No-CCS-100-20-65-HL2-DP-NWH/Havells/philips/Bajaj.
Supply, fix, connecting and testing factory made, MCB distribution board (MCB DB), IP 38, SPN, 4 way, 240 Volts, single door, flush type made out of 1.2mm thick CRCA sheet metal, Phosphatised, duly powder coated and conforming to IS 13032 with 200 Amps rated bus bar, neutral link, earth bar and din rail etc. complete fixed in switch board/ wall complete all as specified and directed. Note: MCBs shall be measured and paid separately.
Supply, fix, connecting and testing MCB single pole and neutral (MCB SPN), 32Amps, 240 volts of rupturing capacity 10kA, C curve type complete all as specified and directed.
Supply, fix, connecting and testing MCB single pole (MCB SP), 6 to 32Amps, 240 volts of rupturing capacity 10kA, C curve type complete all as specified and directed.
M & L concealed sub main wiring with two single core cable of 4 sqmm PVC insulated , 1100 volt grade as per IS 694, with multistranded copper conductor in and including rigid PVC conduit (ISI Marked) including earthing wire of pvc insulated stranded 4 sq mm cable ,chess cutting including S/F of 20 mm dia PVC conduit with elbow,bends,couplers,tee, sunken boxes pressed steel box mounting fitting/junction boxes etc covered the conduit with cement mortar after drawing of electric cables and making good of disturbed surfaces and match with existing shade of wall/roof complete all as specified and directed.
Earthing with galvanised iron earth plate electrode 600 x 600 mm & 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal GL) with top of earth plate not less than 1.5 metre below GL connected to GI earth lead wire 4 mm dia connected to earth plate electrode by means of GI nuts, bolts & washers earth wire protected with & including 15 mm dia medium grade ISI marked GI pipe not less than 7.5 metre long all as shown in electrical plate No. 3 MES Schedule Part 1, with & including ; PCC 1:3:6 type B1 reinforced with welded steel wire fabric not less than 4 Kg per Sq M, watering arrangements with 20 mm GI medium grade pipe ISI marked , GI funnel with GI mesh, filling with mixture of common salt & charcoal, necessary excavation and earth work in any type of soil, including test point, testing & commissioning, complete all as specified and as directed. Note : On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost to the Government. GI earth wire with GI pipe protection beyond 7.5 metre measured & paid separately
S &F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chase or burried in ground or drawn in conduit/pipe or in existing drain after taking out RCC/PCC cover block or fixed to poles or any other indicated situation for loop earthing etc.as required GI earth lead wire 4 mm dia connected to Earthing test point all as specified and directed on testing on completion. Note-:The strips are to be bent to shape, drilled with holes, connected with bolts, nuts, washers.
S&F semi grouting industrial socket & plug powder coated made of CRCA sheet complete box comprised with MCB, SP 32 Amps 12 KAMP returning cap. complete all as specified.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4.0 KVA complete all as specified.
Supply, installation,testing & commissioning of 1.5 ton inverter split AC units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quantity with minimum 5 star rating complete all as specified.
PURVA ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .