Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.6 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹24.5 L+₹1.5 L (6.46%)Rejected-AOC | L2 | Rejected-AOC ok | |
| 3 | L3₹24.9 L+₹1.9 L (8.25%)Rejected-AOC | L3 | Rejected-AOC ok | |
| 4 | L4₹25.0 L+₹2.0 L (8.52%)Rejected-AOC | L4 | Rejected-AOC ok | |
| 5 | L5₹26.3 L+₹3.3 L (14.2%)Rejected-AOC CHATAI SHEEP WARD NO 07 NEW MARKET ROAD AHIWARA DURG CHHATTISGARH 490036 | DURG | CHHATTISGARH | 490036 | L5 | Rejected-AOC ok |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
11 Jul 2020, 6:00 pmClosed
Garrison Engineer Gwalior
Garrison Engineer Morar Cantt Gwalior Tel 07512463741
8556/GWL/E8 REPAIR/MAINTENANCE OF INTERNAL ELECTRICAL FITTINGS AND FIXTURE INCL CEILNIG FANS, EXHAUST FANS, TUBE LIGHTS AND GEYSERS IN THE AREA OF AGE E/M AT MORAR CANTT UNDER GE GWALIOR
2020_MES_354028_1
8556/GWL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer Gwalior
As per tender documents
9 documents required · 9 mandatory
₹500
Garrison Engineer
₹50,000
Yes
27 Aug 2020
19 Jun 2020
13 Jul 2020
19 Jun 2020
11 Jul 2020
2 Jul 2020
Amount
Disconnecting and taking down Existing unserviceable geyser of any description any capacity ( 25/50 Ltr.) incl water and electric connections and reinstallation at same locations after repairs, cleaning and descaling complete all as specified and directed ( Note : spare parts shall be measured and paid separately under relevant item)
Supply and fixing heating element(square /triangular/fine threaded type) of cap 1.5 KW ISI mark all as specified and directed. Make:- Escort, Das pass, theeta
Supply and fixing heating element(triangular/fine threaded type) of cap 2 KW ISI mark all as specified and directed. Make:- Escort, Das pass, theeta,
Supply and fixing heating element with flange assembly of cap 1.5 KW ISI mark all as specified and directed. Make:- Escort, Das pass, theeta,
S&F new flange assembly of description made up of copper/brass for geyser of cap 25 ltr ISI mark all as specified and directed.
S&F new flange assembly of description made up of copper/brass for geyser of cap 50 ltr ISI mark all as specified and directed
Disconnecting & taking up or down exisiting US thermostat of any description from at site and S&F thermostat assembly of range 200 C to 850C of any description suitable 25/50 Ltr cap geysers ISI mark all as specifiedand directed.Make:- Recold, Usha, Girish,
S&F indicator lamp 230 Volt of red and green (circular/rectangular type) all as specified and directed. Make:-L & T, BCH, C & S electric
M&L for preparation of surfaces of geyser of 25 ltr cap of any description by applying filler compound and applying two coats of synthetic enamel white paint complete incl writing MES no with black paint height not less than 20mm in the style/pattern as approved and directed.
All as per item No 9 above but cap 50 ltrs
S&F in repairs new water tank steel inner shell of cap 25 ltr.having wall thickness notless than 1 mm all as specified and directed
S&F MS outer cover of any shape of cap 25 Ltr all as specified and directed.
S&F in repairs new water tank steel inner shell of cap 50 ltr.having wall thigness notless than 1 mm all as specified and directed
S&F MS outer cover of any shape of cap 50 Ltr all as specified and directed
Dismantling and S&F PVC connection complete with brass coupling/union rubber washers etc 450mm long suitable for 15mm dia all as specified and directed Make :-Prayag. Symet,
All as per item No 15 but 600mm long
S&F in Repair PVC insulated Flaxible unarmured cable of multi strand copper conductor 3 core of size 4 Sqmm complete all as specified and directed Make :- Finolex, Plaza, Havells
S&F sheet metal earth plug, socket, single pole and neutral with single pole MCB 20. Amps 240 volts in repairs complete all as specified and directed. Make : C&S, MDS, Schneider
S&F sheet metal earth plug, socket complete all as specified and directed. Make : Schneider, Legrand, Havells
S & F plug top three pin suitable for sheet metal earth plug, socket , SPN complete all as specified and directed.
S&F, MCB in repair SP 240 volts, 6 to 40 Amps, 'B' series 10 KA including connection with suitable size copper lugs. complete all as specified and directed.
S&F packing in position fibre grass wool between inner and outer shell of geyser of any description and in any position complete all as specified and directed
M&L for rectification of leakage in the inner shell by soldering and brazing and testing against leakage of geyser of cap 25/50 ltr all as specified and directed
Supply and fixing only fastener with washer complete all as specified and directed by Engr-in-charge
Taking out of ceiling fan from site or store yard of any make, any description 1200 / 1400 mm sweep and any position/locations for repairs, servicing, overhauling, if required, dismantling and opening the ceiling fans, removing the burnt out copper winding and insulating material such as illuminous paper, glass sleeving, cleaning the slots and rewinding the same with supper enamelled copper winding wire of existing wire gauge (Make Atlas (Minal), National, HTP, HWP, Shital etc) with insulating material, insulating varnishing and reassembling the ceiling fan after replacement of unserviceable parts such as split pin, lock nut, rubber packing, clamp of condenser, blade nut, rubber reel insulator, nut bolt, plastic fan canopy and including three core (work shop cable) stranded copper conductor of size 23/0.0076 mm insulated as per required length. All burnt ceiling fan to be check by the Engr in charge concern JE in MES store yard and maintain register then and Rewinding work to be carried out in MES store yard. All the ceiling fan checking, burnt ceiling fan rewinding and testing at E/M Store yard, complete all as specified and as directed.
Taking out of exhaust fan from site or store yard of any make, any description of 450mm sweep and any position/locations for repairs, servicing, overhauling, necessory lathe work if required, (grinding, polishing) etc. dismantling & opening the exhaust fans removing the burnt out copper winding and insulating material, illuminous paper, glass sleeving, cleaning the slots and rewinding the same with supper enamelled copper winding wire, (Make:-Atlas (Minal), National, HTP, HWP, Shital etc) with insulating material, insulating varnishing and reassembling the exhaust fans after replacement of unserviceable parts such as frame nut, rubber packing, clamp of condenser, and including PVC three core (workshop cable) stranded copper conductor cable of size 23/0.0076 mm insulated as per required length. All the exhaust fan checking and burnt exhaust fan rewinding and testing at E/M store yard, complete all as specified and as directed.
All as per item No 26 here-in-before but exhuast fan of size 230/250 mm sweep.
All as per item No 26 here-in-before but exhuast fan of size 300 mm sweep.
Taking out of Wall/Pedestal fan of any make, any description of 400 mm sweep for repairs, servicing, overhauling, necessory lath work if required (grinding, polishing) etc. dismantling & opening the Wall/Pedstal fans, removing the burnt out copper winding and insulating material illuminous paper, glass sleeving, cleaning the slots and rewinding the same with supper enamelled copper winding wire, (Make:-Atlas (Minal), National, HTP, HWP, Shital etc) with insulating material, insulating varnishing and reassembling the Wall/Pedstal fans after replacement of unserviceable parts such as frame nut, knob, regulator switch, clamp of condenser, and including PVC three core (workshop cable) stranded copper conductor cable of size 23/0.0076 mm insulated as per required length. All the wall / pedestal fan rewinding and testing at E/M store yard complete all as specified and as directed.
M & L for necessory lathe work if required for taking out old gun metal bush and refixing of bush for refixing new ball bearing by lathe work.
Taking out of ceiling fan from site or store yard of any make, any description, any sweep and any position for repairs, servicing, overhauling etc. dismantling & opening the fans checking serviceability of parts, overhauling, cleaning, oiling & greasing, fixing the serviceable parts and reassembling the fans after replacement of unserviceable parts such as split pin, lock nut, rubber packing, clamp of condenser, blade nut, rubber reel insulator, nut bolt, plastic fan canopy and including filling material, grinding, and polishing of fan motor shaft if required, and including twin core twisted flexible stranded copper conductor cable of size 23/0.0076 mm insulated as per required length of 1200/1400 mm sweep and testing complete. Ceiling fan checking and servicing at E/M store yard complete all as specified and directed.
Disconnecting, taking out of exhaust fans, wall bracket fans and Air circulater fans etc. from site of any make, any description, any sweep and any position/locations (i.e. Md Accn/OTM accn) for repairs, servicing,overhauling etc. dismantling & opening the fans checking serviceability of parts, overhauling, cleaning, oiling & greasing, fixing the serviceable parts and reassembling the fans after replacement of unserviceable parts such as split pin, lock nut, rubber packing, clamp of condenser, blade nut, and including filling material, grinding, and polishing of fan motor shaft if required, and including twin core twisted flexible stranded copper conductor cable of size 23/0.0076 mm insulated as per required length of and testing complete all as specified and as directed.
Supply only, the following new spare parts suitable for the ceiling / exhaust /wall bracket fans & pedstal fans, air circulating fans etc. of any description any sweep:- Note:- Fixing & testing charges of these items are deemed to be included in the rates quoted under Sch 'A' item No 25 to 32 above.
(a) Ball bearing campack type 6302-2Z Make SKF/HCH/NBC
(b) Ball bearing campack type 6201-2Z Make: SKF/ HCH /NBC
(c) Ball bearing campack type 6202-2Z Make: SKF/ HCH /NBC
(d) Ball bearing campack type 6203-2Z Make: SKF/ HCH /NBC
(e) Ball bearing campack type 6204-2Z Make: SKF/ HCH /NBC
(f) Capacitor ceiling fan of capacity 2.5 mfd (PVC body) + 5%, 440 volts 50 Hz IS - 1709 AAPHS T-Max 850 C. Make: NICCO, SIEMENS, EPCOS & TIBCON & R.D.
(g) Capacitor ceiling fan of capacity 3.15 mfd (PVC body) + 5%, 440 volts 50 Hz IS - 1709 AAPHS T- Max 850 C. Make: NICCO, SIEMENS, EPCOS & TIBCON & R.D
(h) Capacitor ceiling fan of capacity 4.00 mfd (PVC body) + 5%, 440 volts 50 Hz IS - 1709 AAPHS T-Max 850 C. Make: NICCO, SIEMENS, EPCOS)& R.D
S&F, 15 mm bore, 300 mm long down rod made of medium grade galvanised iron pipe including drlling of hole, cutting of slot etc.complete all as specified and as directed.
S&F, 15 mm bore, 900 mm long down rod made of medium grade galvanised iron pipe including drlling of hole, cutting of slot etc.complete all as specified and as directed.
S&F, 15 mm bore, 1200 mm long down rod made of medium grade galvanised iron pipe including drlling of hole, cutting of slot etc.complete all as specified and as directed.
S&F, 15 mm bore, 2400 mm long down rod made of medium grade galvanised iron pipe including drlling of hole, cutting of slot etc.complete all as specified and as directed.
S&F, 15 mm bore, 3600 mm long down rod made of medium grade galvanised iron pipe including drlling of hole, cutting of slot etc.complete all as specified and as directed.
Desconnecting, taking out old existing un serviceable fan regulator of any description & in any position / location and supplying and fixing connecting and testing resistance type fan regulator complete all as specified and as directed. Make : Bajaj / Havells / Orisson / USHA
Desconnecting, taking out old existing un serviceable fan regulator of any description & in any position / location and supplying and fixing connecting and testing electronic step up rotary type regulator 100 watt complete all as specified and as directed. Make : Leader, Anchor & Cona
S&F, in replacement of hanging clamp of ceiling fan with nut bolt , rubber real insulator and split pin complete all as specified and as directed.
Supplying and fixing only aluminium cast metal ceiling fan blade complete with neccessory MS nuts bolts & washers suitable for ceiling fans of any descriptions complete all as specified and as directed.
Supply and fixing aluminium cast metal Exhaust fan blade complete set with necessary M S nut, bolts & washers suitable for exhaust fans of 230 / 300 mm sweep of any descriptions complete all as specified and as directed.
Supplying and fixing only Exhaust fan blade complete set of iron leaf (four) with neccessory MS nuts, bolts & washers suitable for exhaust fans 450 mm sweep of any descriptions complete all as specified and as directed.
S&F, PVC fresh air fan blade complete with necessary MS nut, bolts and washers for fresh air fans of 230 / 300 mm sweep of any description with plastic MS frame of PVC body fresh air fan complete all as specified and as directed.
M&L, two coats of painting of ceiling fan with blade sets of any make any sweep complete on site or store with synthetic supper enamel white paint of approved make by brush painting and filling with filler including preparation of surface fan blade (set of three) including rewriting MES No of fan in capital letters of height not less than 20 mm on body with black Japan paint complete all as specified and as directed.
All as per item No 46 here-in-before but exhuast fan any make any sweep with synthetic grey paint -ditto-.
S&F 15 inch clamps for fixing for exhaust fans
S&F 18 inch clamps for fixing for exhaust fans
S & F MS clamps suitable size for 40mm dia pipe with MS nut, bolt etc complete all as directed.
M/s raj construction
SWAMI CONSTRUCTION
m/s varsha traders
M/S SANTOSH CONSTRUCTION CO
M/S Solanki Brothers
M/s Shree Ram and Sons
UNIVERSAL AGENCY
m/s anil traders
Babatia super works
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .