Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹61.1 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹64.8 L+₹2.3 L (3.68%)Rejected-Finance 1202 SAI PROVISO DHNISHT PLOT NO 72 73 SECTOR 20 KOPARKHAIRANE NAVI MUMBAI | THANE | MAHARASHTRA | 400601 | L2 | Rejected-Finance Other than being lowest | |
| 3 | L3₹71.5 L+₹9.0 L (14.3%)Rejected-Finance | L3 | Rejected-Finance Other than being lowest | |
| 4 | L4₹82.7 L+₹20.2 L (32.3%)Rejected-Finance | L4 | Rejected-Finance Other than being lowest | |
| 5 | L5₹83.5 L+₹20.9 L (33.5%)Rejected-Finance 1 14 SUJAL MANSION B BLOCK BHANGWADI KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L5 | Rejected-Finance Other than being lowest |
Tender Value
₹89.5 L
EMD Value
₹1.6 L
Closing Date
5 Oct 2024, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
REPAIR/REPLACEMENT OF FIRE ALARM SYSTEM OF VARIOUS CENTERS OF NAVAL DOCKYARD MUMBAI UNDER GE (NW) KUNJALI
2024_MES_669762_1
8369/CWE (NW) Mumbai/E8
Open Tender
Civil Works
Item Rate
330 days
GE (NW) Kunjali
Class C
Category c (vi)
7 documents required · 7 mandatory
₹1,000
GE (NW) Kunjali
₹1.6 L
Yes
17 Dec 2024
2 Sept 2024
7 Oct 2024
2 Sept 2024
5 Oct 2024
23 Sept 2024
2 Sept 2024 - 21 Sept 2024
Amount
Comprehensive maintenance of auto fire alarm systems/ fire supression system installed at Naval Dockyard including attending day to day complaints. The detail scope of work consists of the following:- (i) Cleaning, inspecting, checking all the equipments of fire detection / supresssion system and repairing if required as directed by Engineer-in- Charge in writing . (ii) Operational test of all the equipment of fire detection system in presence of rep of users and Engr-in-charge and submission of reports every month. (iii) Emergency visit will be carried out when called in addition to the routine monthly maintenance in case of any failure in the system due to any cause without additional cost. (iv ) Material required for replacement will be measured and paid separately under respective items of this schedule as SUPPLY ONLY.
Supply, Installation, testing & commissioning in repairs photo electric smoke cum thermal detectors with mounting base complying with and type certified to EN - 45 Addressable type with self built intelligence as per IS: 11360 complete suitable for existing system and directed by Engineer-in-Charge.
Supply, Installation, testing & commissioning of analogue addressable Multi Criteria (Optical +thermal) detector with mounting based LED for AFC (Above Celling & below celing) complete all as specified and directed by Engineer-in-Charge.
Supply, Installation, testing and commissioning addressable Manual call point (Pull down/ Break Glass Type). The device shall have an LED which shall blink in normal state and get steady on activation to monitor the health status of the device and shall be underwritters of laboratories listed, semi flush type complete all as specified and directed by Engineer-in-Charge.
Supply, Installation, testing and commissioning conventional Manual call point (Pull down/ Break Glass Type) comprising an LED which shall blink in normal state and get steady on activation to monitor the health status of the device and shall be underwritters of laboratories listed, semi flush type complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs intelligent addressable monitor module as per existing.
Supply and fixing in repair fault isolator module with automatic resetting arrangement complete all as specified and directed by Engineer-in-Charge.
Supply, installation, Testing & Commissioning in repairs Response indicator for above ceiling detectors & Cabin Detectors complete all as specified and directed by Engineer-in-Charge.
Supply, installation, Testing & Commissioning in repair Addressable control modules for AHU, Access control Integration & stairs Pressurization Fan Hooters / Sounders / Strobes etc. complete all as specified and directed by Engineer-in-Charge.
Supply, installation, Testing & Commissioning in repair addressable electronic hooter with built in amplifier unit with two tone generator of 100 meter range complete all as specified and directed by Engineer-in-Charge.
Supply, installation, Testing & Commissioning in repair addressable/ conventional type heat detector with base, rate of temperature rise as per IS-2175 complete all as specified..
Supply , installation, Testing & Commissioning in repair Conventional Beam detector suitable for hall & indoor open area complete all as specified and directed by Engineer-in-Charge.
Supply, installation, Testing & Commissioning in repair addressable Fire alarm control panel complying with BSEN54/UL single loop panel of capacity from 126 detectors & 126 modules complete all as specified.
Supply, installation, Testing & Commissioning in repair addressable Fire alarm control panel complying with BSEN54/UL double loop panel of capacity from 126 detectors & 126 modules complete all as specified.
Supply, installation, Testing & Commissioning in repair addressable Fire alarm control panel complying with BSEN54/UL four loop panel of capacity from 126 detectors & 126 modules complete all as specified.
Supply, installation, Testing & Commissioning in repair addressable fire alarm Repeater panel as per existing complete all as specified.
Material & labour for taking out unserviceable repeater control panel from the existing site and repairing the repeater panel including replacement of unserviceable parts complete and refixing the same in its original position including testing commissioning complete all as specified and directed.
Supply and fixing in replacement of PCB loop cord suitable for self addressable fire finder system.
Supply & laying PVC FRLS armoured cable 1.5 sq mm solid copper conductor 2 core, XLPE Insulated, Extruded PVC sheathed, galvanized steel strip, electric power cables (heavy duty) 1100 Volts grade, laid in duct / along pole/wall etc including making connection complete and making good the distrubed surface matching with existing surface complete all as specified and directed by Engineer-in-Charge. Note : The cost of All thimbles/lugs and cable gland shall deemed to be included in quoted rate and no extra payment will be made for it.
Supply & laying PVC FRLS armoured cable 1.5 sq mm solid copper conductor 4 core, XLPE Insulated, Extruded PVC sheathed, galvanized steel strip, electric power cables (heavy duty) 1100 Volts grade, laid in duct / along pole/wall etc including making connection complete and making good the distrubed surface matching with existing surface complete all as specified and directed by Engineer-in-Charge. Note : The cost of All thimbles/lugs and cable gland shall deemed to be included in quoted rate and no extra payment will be made for it.
Supply and fixing 20 mm bore MS Conduit including all fixing accessories like saddles, couplers, bends, tees etc complete all as specified and directed.
Supply and fixing in replacement UPS 1.0 KVA suitable for working on 230 Volts, 50 Hz AC supply complete all as specified and directed.
Supply only 12 V 7 AH Battery complete all as specified.
Disconnecting and taking out old unserviceable Mother Board of fire finder system and supply and fixing new mother board for two Nos loops cards suitable for self addressable fire finder.
Material & labour for refilling NOVEC 1230 or FM 200 gas in cylinder, incluing taking out cylinder from site to factory and taking back the same including replacing unserviceable pressure gauges/ connector pipes and other connected items as per existing complete all as specifed
Supply & fixing in repaairs nozzle / sensor of fire supression system at various buildings as per existing type and make complete all as specifed
Supply, installation, Testing & Commissioning in repair conventional Gas release Fire alarm control panel complying with BSEN54/UL single loop panel of capacity from 126 detectors & 126 modules complete all as specified.
ASHOK ENTERPRISES (BID ID -3113598)
Shetty Construction Co (BID ID -3119081)
Hardik Engineers (BID ID -3116545)
Chakshu Enterprise (BID ID -3119687)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .