Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹2.9 L
Closing Date
26 Aug 2024, 10:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Karnataka Power Transmission Corporation Limited
S A Karpali
Tender for the work of Modification in the existing 220 kV Terminal Bay of 220kV Doni 1 & 2 lines at 220kV Station Gadag due to strengthening of 220 kV Gadag -Doni DC line by replacing Drake Conductor by HTLS Conductor in Gadag Taluka Gadag Dist on Total Turnkey Basis.
KPTCL/2024-25/EL/WORK_INDENT990
KPTCL/2024-25/EL/WORK_INDENT990
Open
Electrical
Two Tender Document System(Two Cover)
KPTCL SEE Transmission Works and Mantainance Circle Hubballi
17 documents required · 17 mandatory
01. If the bidder participates individually, then the Bidder should possess valid Super Grade Electrical Contractors License issued by the Government of Karnataka as on the date of opening of techno-commercial bid and shall upload the same along with other bidding documents failing which the offer will be rejected.(b) In case the bidder participates in consortium, the lead Bidder should possess valid Super Grade Electrical Contractors License issued by the Government of Karnataka as on the date of opening of techno-commercial bid and shall upload the same along with other bidding documents failing which the offer will be rejected. In addition, the bidder should have the following qualifying requirements (Technical).
02. a) Should have constructed at least one number of 220kV Terminal bay or above class along with all connected equipments in last five years on Total Turnkey or Partial Turnkey basis which shall be in satisfactory service for a period of One year prior to date of submission of the Bid. OR (b) Should have constructed 220 kV Transmission Line or above class to an extent of 10 Kms in last five years on Total Turnkey or Partial Turnkey basis which shall be in satisfactory service for a period of One year prior to date of submission of the Bid. OR (c) Should have carried out the work of providing additional/replacement of 220kV and above class Breakers/CT/PT or 220kV Bay Strengthening Work in KPTCL /any Govt., or Public sector under takings in last five years on Total Turnkey or Partial Turnkey basis which shall be in satisfactory service for a period of One year prior to date of submission of the Bid
03.Minimum Average Annual Turnover (MAAT) of the bidder for best three years out of last preceding five financial years ending on March or December as the case may be, shall not be less than Rs. 291.47 Lakhs
04.The Consortium having combined Technical Qualification as at 3.1 and 3.2 along with Financial capability as at4.0 are also eligible to participate in the Bid subject to the following (I) (a) Any one of the Consortium Partner shall meet the Technical Capability prescribed at 3.1 and 3.2.OR(b) The consortium partners shall individually meet the technical capability prescribed at 3.1 or 3.2.(II) Financial requirement prescribed at 4.0 shall be met by any of the consortium partners or jointly by both the partners of the consortium
05.The Bidder shall stand disqualified if the total value of Works on hand including contract against subject tender if awarded, exceeds 2 times the MAAT (minimum average annual turnover (Refer 11.6.2.4 of IFB).
06.The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years with KPTCL. A history of awards involving litigations against the bidder or any party or JV may result in rejection of bid Bidders are requested to furnish the self-declaration stating the above and upload the same along with the other documents in the relevant field in the eprocurement portal failing which the offer is liable to be rejected
07.The bidder should not have been blacklisted by any Government Department/Power Utilities/Local Bodies of any state. A self declaration in this regard is to be uploaded
08.No Deviation declaration
09.Non performance: The bidder should not have been disqualified for non-performance in any of the Government utilities in the past five years and bidder shall furnish a self-declaration to this effect, failing which the offer is liable to be rejected
10.Power of Attorney in favour of all the persons signing the documents
11.Letter of Undertaking
12.GST and PAN registration certificate
13.Risk and cost declaration
15. Self declaration regarding source of supply of equipment/material from KPTCL Approved Vendors only.
14.EPF and ESI REGISTRATION CERTIFICATE ISSUED BY CONCERNED
16.Techno Commercial Sheets Duly filled
17.A certificate is required to be uploaded by both Bidder and Consortium Partners separately regarding restriction on procurement from a Bidder/Consortium Partner of a country which shares a land border with India in the format as specified in the clause No.1.5 of Annexure - XVIII of the Tender document
18.Certificate of Incorporation of all the participating companies in case of registered companies / Partnership deed in case of Partnership Firm
19. Any Additional Documents if required as per tender documents
₹4,860
₹2.9 L
3 Aug 2024
3 Aug 2024
27 Aug 2024
12 Aug 2024
13 Aug 2024
Isolator with operating mechanism and marshalling
boxes, terminal connectors etc., as per technical specification ...
ii) Upright without Earth switch (Live Point height 5750 mm)
2) Under hung mounting type without earth switch (13000 mm Mounting height )
2) Terminal Connector for Isolator to receive :
a.Twin Moose ACSR conductor with 250 mm sub conductor spacing
CURRENT TRANSFORMER : 5 Cores with marshalling boxes, terminal
connectors etc., complete as per technical specification :
(i) 220 kV Class, 40 kA CT with ratio 3000-2000/1-1-1-1-1 A
(Note: 06 No's ...
Wavetrap : 1.0 mH, 3150A , 40 Ka along with terminal connector suitable for Double Moose ACSR.
MOOSE ACSR Conductor:
a. Disc insulator 120KN
(Double tension string : 2 strings of 16 units each)
b. Disc Insulator 90KN,
( Suspension Disc insulator string: strings of 14 units )
Insulator Hardware & Clamps:
a .Bolted type Tension clamp to suit Twin Moose ACSR Conductor 120 kN, 20 mm
b.Bolted type Suspension clamp to suit Twin Moose ACSR Conductor 90 kN, 16 mm
c. C Type wedge connector suitable for MOOSE ACSR to MOOSE ACSR
d. Spacers for Twin Moose ACSR conductor
with 250 mm Sub Conductor spacing
e. Terminal Connector for CB to receive Twin moose ACSR Conductor.
f. Terminal Connector for CT to receive Twin moose ACSR Conductor.
g. Clamps for BPI to receive Twin moose ACSR Conductor.
h Terminal Connector for Wave Trap to receive ACSR Moose.
i. Terminal Connector for CVT to receive Twin ACSR Moose.
j. Terminal Connector for LA to receive Twin ACSR Moose.
Copper Control Cables
a. 4C, 6 Sqmm Copper Control cable for CT Wiring
b. 10C, 2.5 Sqmm Copper Control cable for CT Wiring
c. 14C, 2.5 Sqmm Copper Control cable for CT Wiring
c. 4C, 2.5 Sqmm Copper Control cable for CT Wiring
Erection Portion
Isolator with operating mechanism and marshalling
boxes, terminal connectors etc., as per technical specification ...
ii) Upright without Earth switch (Live Point height 5750 mm)
2) Under hung mounting type without earth switch (13000 mm Mounting height )
CURRENT TRANSFORMER : 5 Cores with marshalling boxes, terminal
connectors etc., complete as per technical specification :
(i) 220 kV Class, 40 kA CT with ratio 3000-2000/1-1-1-1-1 A
(Note: 06 No's ...
Wavetrap : 1.0 mH, 3150A , 40 Ka along with terminal connector suitable for Double Moose ACSR.
Bus Bar formation
Copper Control Cables
a. 4C, 6 Sqmm Copper Control cable for CT Wiring
b. 10C, 2.5 Sqmm Copper Control cable for CT Wiring
c. 14C, 2.5 Sqmm Copper Control cable for CT Wiring
c. 4C, 2.5 Sqmm Copper Control cable for CT Wiring
Testing & Commissioning
Isolator with operating mechanism and marshalling
boxes, terminal connectors etc., as per technical specification ...
ii) Upright without Earth switch (Live Point height 5750 mm)
2) Under hung mounting type without earth switch (13000 mm Mounting height )
CURRENT TRANSFORMER : 5 Cores with marshalling boxes, terminal
connectors etc., complete as per technical specification :
(i) 220 kV Class, 40 kA CT with ratio 3000-2000/1-1-1-1-1 A
(Note: 06 No's ...
Decommissioning Portion
Dismantling of 220KV Current Transformers of 220KV Doni Line 1 and 2.
Dismantling of Wiring of 220KV Doni Line 1 and 2.
Dismantling of 220KV Upright Isolators of 220KV Doni Line 1 and 2.
i) 220KV Line Isolators - 02Sets.
ii) 220KV Breaker Isolators - 02Sets.
Iii) 220KV Bus Isolators - 04Sets.
Dismantling of 220KV Under Hung Isolators of 220KV Doni Line 1 and 2.
i) 220KV Line Under hung Isolators - 02 Sets.
Dismantling of 220KV Bay Conductors (Drake ACSR)
Dismantling of 220KV wave traps.
Loading of released bay equipment's & connected materials like clamps, conductors and Insulators etc @ 220KV Station Gadag.
Un-Loading of released bay equipment's & connected materials like clamps, conductors and Insulators etc @ TL&SS Divisional Store Hubballi.
Releasing of existing Control Cable from equipement to Control and Relay Panel.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Volume II_Vol II A 2 0f 2 Tech Spec_Line_SECTION I.docx
Tender Document • 0.04 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Line_SECTION II.docx
Tender Document • 0.03 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Line_SECTION III.docx
Tender Document • 0.10 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Line_SECTION IV and V.docx
Tender Document • 0.08 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Line_SECTION IX.docx
Tender Document • 0.05 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Line_SECTION VI.doc
Tender Document • 0.44 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Line_SECTION VII and VIII.docx
Tender Document • 0.09 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Line_SECTION X.doc
Tender Document • 0.12 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_1. Section General Technical Requirement.pdf
Tender Document • 0.51 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_2. Section Isolator.pdf
Tender Document • 0.21 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_3. Section power and control cable.pdf
Tender Document • 0.74 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_4. Tech Specification of PLCC equipment.pdf
Tender Document • 0.53 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_5. Section Testing and Commissioning.doc
Tender Document • 0.05 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_66 110kV C&R Panel Spec with Numerical Relay.pdf
Tender Document • 0.72 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_DLMS TVM TECH SPEC.pdf
Tender Document • 18.40 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_Instrument Transformer_CT chart New.doc
Tender Document • 0.10 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_Instrument Transformer_Section Instrument Transformer.pdf
Tender Document • 0.20 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_Section 100 150MVA Transformer spec.pdf
Tender Document • 1.24 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_Section 11KV UG Cable.pdf
Tender Document • 0.24 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_Section 20MVA and below power transformer.pdf
Tender Document • 0.88 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_Section 220V 300AH Battery Set New.pdf
Tender Document • 0.25 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_Section AC outdoor distribution box.pdf
Tender Document • 0.33 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_Section Air Conditioning.docx
Tender Document • 0.02 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_Section Aux Tranformer.pdf
Tender Document • 0.49 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_Section C&R Panel Duplex type without SAS.pdf
Tender Document • 1.08 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_Section cable sealing system.doc
Tender Document • 0.04 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_Section Capacitor bank.doc
Tender Document • 0.08 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_Section Circuit Breaker.pdf
Tender Document • 0.50 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_Section DG SET.pdf
Tender Document • 0.27 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_Section Fire protection.pdf
Tender Document • 0.16 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_Section Furniture.doc
Tender Document • 0.03 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_Section Lighting system.docx
Tender Document • 0.08 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_Section LTAC Panel.pdf
Tender Document • 0.21 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_Section Relay & Protection Panel with SAS.pdf
Tender Document • 1.63 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_Section Structures.doc
Tender Document • 0.04 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_Section Surge Arrester.pdf
Tender Document • 0.12 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_Section Switchyard erection.pdf
Tender Document • 0.58 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_Surveillance systems for Stations.doc
Tender Document • 0.37 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_Testing & maintenance equipments_BDV test kit new.docx
Tender Document • 0.02 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_Testing & maintenance equipments_CB Analyzer.docx
Tender Document • 0.03 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_Testing & maintenance equipments_CRM .docx
Tender Document • 0.02 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_Testing & maintenance equipments_CTPT CVT Analyzer.docx
Tender Document • 0.03 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_Testing & maintenance equipments_Digital insulation Tester new.docx
Tender Document • 0.02 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_Testing & maintenance equipments_Moisture titrator new.docx
Tender Document • 0.02 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_Testing & maintenance equipments_num relay kit new.docx
Tender Document • 0.03 MB
Volume II_Vol II A 2 0f 2 Tech Spec_Station_Testing & maintenance equipments_Tan delta.docx
Tender Document • 0.03 MB
Volume II_VOL II B HTLS.docx
Tender Document • 0.34 MB
Volume II_Volume IIA 1 of 2 HTLS.docx
Tender Document • 0.42 MB
Volume II_Volume IIA 2 of 2 HTLS.docx
Tender Document • 0.77 MB
Volume II_~$lume IIA 2 of 2 HTLS.docx
Tender Document • 0.00 MB
1 NIT_HTLS Gadag.pdf
Tender Document • 0.69 MB
4 Techno Comm HTLS Gadag.xlsx
Tender Document • 0.81 MB
Volume I_Annexure.docx
Tender Document • 0.08 MB
Volume I_ECC HTLS.docx
Tender Document • 0.04 MB
Volume I_GCC HTLS.docx
Tender Document • 0.06 MB
Volume I_IFB HTLS.docx
Tender Document • 0.06 MB
Volume I_ITB HTLS.docx
Tender Document • 0.06 MB
Volume I_SCC HTLS.docx
Tender Document • 0.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .