| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹43.0 L+₹7.4 L (20.8%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹44.9 L+₹9.3 L (26.0%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Others-Not meeting the pre qualification criteria |
Tender Value
₹43.5 L
EMD Value
₹86,998
Closing Date
8 Jan 2024, 10:00 amClosed
Atul Bhardwaj
Hauz Khas
Provision of CCTV Surveillance system and PA system at Millenium Park 1, Chirag Delhi Village in ward no. 172 in Greater Kailash Assembly (AC-50) under South Zone MCD.
2023_MCD_179821_1
MCD/TR/2963/2023_6_1_1
Open Tender
Electrical Works
Item Rate
60 days
Greater Kailash AC-50
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹86,998
Civic centre Delhi
5 Apr 2024
1 Jan 2024
8 Jan 2024
1 Jan 2024
8 Jan 2024
1 Jan 2024
3 Jan 2024
Amount
Approved Rates Items
122.2.50:"SITC of 2MP varifocal lens Dome IP Camera with following specifications:- Image Sensor: 1/2.8 2MP CMOS or better** Minimum Illumination: 0.1 lux color, 0 lux with IR or better ** Shutter Speed:1/3 - 1/100,000 s Frame Rate: 25 fps or better ** Lens: 2.8 to 12mm Varifocal lens Video Compression: H.265 or better ** S/N Ratio: >45dB Resolution: 1080p(1920x1080) or better ** Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1X IR Range: Minimum 20m Operating Temperature: -20 to 50 deg Cent Weatherproof Standard: IP66 or better ** Safety standard: UL "
122.2.53:"SITC of 4MP PTZ Camera with following specifications:- Image Sensor: 1/2.8 2MP CMOS or better** Minimum Illumination: 0.1 lux color, 0 lux with IR or better ** Shutter Speed:1/3 - 1/50,000 s Frame Rate:25 fps or better ** Lens: 30 X ZOOM Video Compression: H.265 or better ** S/N Ratio: >45dB Resolution: (1920x1080) or better ** Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1X IR Range: Minimum 20m Operating Temperature: -20 to 55 deg Cent Weatherproof Standard:IP66 or better ** Safety standard: UL "
122.2.62:SITC of 8 port Giga PoE switch, 8(PoE 10/100) + 2(10/100) port long distance switch
122.2.68:SITC of 10 TB surveillance HDD
122.2.70:"SITC of full HD LED Monitor,42 INCHES complying with the following specifications: Resolution : Full HD : 1920 x 1080 or better Backlight : LED Brightness : 300 NITS min. Contrast : 1200 : 1 or better Power supply : 230v + / - 10%, 50 Hz at site with connections and along with all accessories etc. complete as required. "
122.2.60:"SITC of 32 channel NVR with the following specifications: Camera resolution:upto8MP Interface: 1 HDMI, 1VGA minimum Compression :H.265or better** Network Throughput :200Mbps or better** USB Port: 2 USB port (USB2.0)minimum Hard disk interface: 2 SATA port suitable for 6TB each Protocol: IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS Operating temp: -10 to 55 deg Cent Safety standard: UL "
122.2.77:SITC of On-line UPS with inbuilt isolation transformer suitable for single phase AC input and single phase AC output, Floor mounted type, indicative power backup time of 60 mins through SMF batteries. 3KVA
122.2.82:SITC of following rack capacity with glass front door, steel rear door, power supply, MCB, cable manager, drawer shelves and wiring channels to accommodate CCTV systems equipment and complete with accessories as reqd.17 U
122.2.73:SITC of Pigtails 1 meter with Splicing and testing.
122.2.74:SITC of optical media converter gigabit SC to SC type up to 10 km single mode
122.2.75:SITC of LIU boxes complete with all accessories etc. as required of 12 ports
122.2.76:SITC of Optical Fiber Single Mode Cable (6-Fiber) on surface or in existing conduit etc complete i/c connections etc complete as required
122.2.10:Providing and laying in position M25 grade reinforced cement concrete foundation of size 450 mm (L) ×450 mm wide and 1000 mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia- 960 mm long(approx)-8 nos. and reinforcement of cold twisted bars of 8 mm dia- 1400 mm (approx) -6 nos.(with 150 mm spacing) as required with supplying and positioning of 4 nos. foundation bolts 16 mm dia,600 mm long, J type i/c 2 nos. template anchor plates of size 225mm×225mm×3mm and providing DCW HDPE for cable entry and exit as required for 3 m and 5 mtr pole.
122.2.72:SITC of IP65 box (without PoE switches)of dimention 310mmX160mmX140 mm on pole or wall with suitable arrangement for support/installation of 8 port Giga PoE switch and 1 nos. 15/16 amp modular switch socket set
OD1214/2023-2024:SITC all weather proof loudspeaker for speakers for outdoor ground , having sound LF, HF - 1" exit Max SPL not less than 128db /1m (peak), with continuous RMS power of 45 - 55 Watt RMS with programmed power of 90 – 110 Watt RMS & peak power of 180 - 220 Watt RMS with minimum sensitivity of 97db, Nominal Impedance : 8 ohms, nominal dispersion : 90 x 60, in birch plywood paint finish with wall mount bracket , suitable size MS frame box cover for protection etc. complete as required.
122.1.2:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm
OD1347/2023-2024:Supply installation testing & commissioning of Dual Channel Power Class H/ D amplifier for Subwoofer & Main Speakers & outdoor speakers 2000 watt, Damping factor > 450, as required.
OD1348/2023-2024:Supply installation testing & commissioning of Professional total 16 channel audio mixer with 16 mic inputs; 2 line inputs 2 stereo inputs; with inbuilt effects and equalizer, graphic EQ etc. complete as reqd.
OD13047/2023-2024:Comprehensive maintenance of whole CCTV and PA system for another four years after completion of 1 year warranty or defect liability period. 2nd Year
OD13048/2023-2024:Comprehensive maintenance of whole CCTV and PA system for another four years after completion of 1 year warranty or defect liability period. 4th year
OD13049/2023-2024:Comprehensive maintenance of whole CCTV and PA system for another four years after completion of 1 year warranty or defect liability period. 5th year
OD13050/2023-2024:Comprehensive maintenance of whole CCTV and PA system for another four years after completion of 1 year warranty or defect liability period. 3rd year
DSR Item E&M 2022
OD12938/2023-2024:14.16.1 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
OD12939/2023-2024:7.6.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. upto 35 sqmm
OD12940/2023-2024:7.5.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
OD12941/2023-2024:1.21.2 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
OD13042/2023-2024:1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
OD13043/2023-2024:1.53.1 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable.
RKJ ELECTRIC
JINDAL INDUSTRIES
Bidder Name
SPYVISION SOLUTIONS AND TECHNOLOGY PRIVATE LIMITED
RKJ ELECTRIC
JINDAL INDUSTRIES
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .