PROFESSOR IN-CHARGE
University Engineering Department, Banaras Hindu University Varanasi
Dehydration of Transformer oil of 11/415 KVanmd33/11 KV Power transformers and Providing and Fixing the breather along with the Silica gel, suitable for 500KVA/800KVA/2000KVA/10MVA/12 MVA Transformer at various location at PSS/DSS, BHU
2026_BHU_923418_2
UED/2026/24082026-1
Open Tender
Electrical Works
Works
60 days
UED BHU Varanasi
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
Registrar, Banaras Hindu Unversity
₹7,812
12 Sept 2026
12 Sept 2026
22 Oct 2026
12 Sept 2026
19 Oct 2026
12 Sept 2026
12 Sept 2026 - 15 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing and Fixing the breather along with the Silica Gel, suitable for 400KVA/800KVA/2000KVA/10MVA/12MVA Transformer at various location at PSS/DSS , BHU complete as required at site including dismantalling the existing damaged breather the damaged breather will be credited to the contractor .
0.5 Kg (MR) | 23 | Sets | 1,233 | ₹28,359 |
| 2 | Providing and Fixing the breather along with the Silica Gel, suitable for 400KVA/800KVA/2000KVA/10MVA/12MVA Transformer at various location at PSS/DSS , BHU complete as required at site including dismantalling the existing damaged breather the damaged breather will be credited to the contractor .
1 Kg (MR) | 23 | Sets | 1,803 | ₹41,469 |
| 3 | Providing and Fixing the breather along with the Silica Gel, suitable for 400KVA/800KVA/2000KVA/10MVA/12MVA Transformer at various location at PSS/DSS , BHU complete as required at site including dismantalling the existing damaged breather the damaged breather will be credited to the contractor .
2Kg (MR) | 2 | Sets | 3,017 | ₹6,034 |
| 4 | Dehydration, filtration and Breakdown Voltage (BDV) testing of transformer insulating oil of existing 11/0.415 kV ( 400KVA/500KVA/1000KVA )and 33/11 kV (10MVA/12.5MVA ) power transformers, including mobilization of oil filtration plant, circulation of transformer oil through high-vacuum dehydration and filtration machine, removal of moisture and impurities, conducting BDV test before and after filtration as per relevant IS/IEC standards, submission of test reports, and all labour, tools, tackles, consumables and transportation required for complete execution of the work. (MR) | 35,000 | Liters | 9 | ₹3,15,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.39 MB
Bid_Document08.pdf
Tender Documents • 1.17 MB
BOQ_973070.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .