| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹48.9 LAdmitted-Finance | -31.36% | ₹48.9 L | L1 | Admitted-Finance |
| 2 | L2₹49.3 LAdmitted-Finance | -30.88% | ₹49.3 L | L2 | Admitted-Finance |
| 3 | L3₹54.2 LAdmitted-Finance | -23.89% | ₹54.2 L | L3 | Admitted-Finance |
| 4 | L4₹57.5 LAdmitted-Finance | -19.33% | ₹57.5 L | L4 | Admitted-Finance |
Tender Value
₹71.3 L
EMD Value
₹1.4 L
Closing Date
11 Feb 2026, 12:00 pmClosed
EECD V
EECD V IFC Deptt Paryavaran Complex Saidulajab ND-30
Renovation Harijan Basti Chaupal at Ghitorni Village in Chhattarpur Assembly Constituency AC-46.
2026_IFC_286265_1
NIT No.102/25-26/EECD -V/ACS
Open Tender
Civil Works
120 days
Chattarpur AC-46.
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹1.4 L
17 Feb 2026
5 Feb 2026
11 Feb 2026
5 Feb 2026
11 Feb 2026
5 Feb 2026
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
Demolishing mud phaska in terracing and disposal of material within 50 metres lead.
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete.
Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete. Granite of any colour and shade
Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Raj Nagar plain
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 10 x 120 mm
6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand)
12 mm cement plaster of mix1:6 (1 cement: 6 coarse sand)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin- charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 550x400 mm witha pair of 15 mm C.P. brass pillar taps
Providing and fixing PTMT bib cock of approved quality and colour. 15mm nominal bore, 86 mm long, weighing not less than 88 gms
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Renewing panes, with putty and nails wherever necessary including racking out the old putty: 3 mm thick translucent white acrylic plastic sheet
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Circular tank
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal outer dia Pipes
PPGI Puff Panel material used for developing of porta cabin: Material Details for Puff Panel Office (i) Bottom fixing with coated mm thick “C” channel flashing 50x50x50mm with 8mm fastener. (ii)50mm thick powder-coated(PPGI) sandwich puff panel for side wall . (iii) 50x80mm thick powder-coated(PPGI) sandwich puff panel for roof. (iv).Corner panels(inner & outer) covered with PPGI 0.5mm thick powder coated flashing 50x50mm. (V) Roof Corner flashing outer covered with 0.5mm thick ”C” channel flashing 75x75mm. (vi) Cam-lock for holding/joint puff panel sheets covered with PVC lock and cap.(vii)Silicon for fixing joints between every puff panel sheet. (viii)Pop-ripit for fixing flashing with puff panels. (ix) ”L” shape corner outer column flashing 10x100mm. (x)30mmthick puff panel door with patam /chokhat flashing. (xi)Door lock, SS handle,4” SS Kabze. (Xii)Aluminum powder coated sliding windows with aluminum safety grill(4’x3’). (xiii) Electric open fitting with ISO mark wires of 4mm,2.5mm,1.5mm and 0.75mm (xiv)ISO mark switch & socket, LED tube light, mcb and bulket light(outer). (xv)500x500mm vitrified tiles on the carpet area of porta cabin. (xvi) Labour charges fo installation/fixing job of puff panel, tiles and electric work. (xvii)Switch, socket, tubelight and MCB for porta cabin and 02no. separate MCB for spilt AC. (xviii)Separate toilet with WC, washbasin, Urinal and water tap(Size:8'x 4’). (xix) Separate Kitchen with sink , water tap and storage(Size:8'x 4’). (xx) Spilt A.C.2 Ton. Transportation Charge included.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sqm. Mm F.R. L.S. PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with piano type switch, phenolic laminated sheet suitable size ;M.S. box and earthing the point with 1.5 sq.mm FR L.S. PVC insulated copper conductor single core cable as required (Group C).
Supplying installation, testing and commissioning of bulk head fitting suitable for 60/100 watt GLS lamp complete with Lamp and accessories such as glass, wire guard, lamp etc. including connection as required (Make Surya, Baja, Wipro, Philips, Havells) or as approved by the Engineer-in-charge.
Supplying installation testing and commissioning of energy efficient ceiling, /wall/guarder mounting prewired fluorescent tube light fitting suitable 36/40 watt lamp. The fitting shall be completed with electronic ballast, lamp & holder duty wired up ready for 240 volts, single phase, 50Hz AC supply confirming to IS: 10322 as per quality requirement. Fitting shall be provided with all accessories and mounting arrangement as required, including connection with 1.5 sqm. Mm FR PVC insulated copper conductor single core cable and earthing etc. (Make Surya, Bajaj, Havells, Philips Wipro) or as approved by the Engineer-in-charge.
Supplying installation, testing and commissioning of 1200 mm sweep AC electric ceiling fan capacitor type with double ball bearing complete with down rod, canopies, shackles, blades but with out regulator suitable for operation on 230/240 volts, 50 Hz single phase AC supply including wiring the down road of standard length up to 1 mtr. With 2x1.5 sq. mm PVC insulated copper conductor with fan sheet etc. as required (Make Bajaj, Orient, Usha, Havells polar).
Supplying , installation, testing and commissioning of Heavy duty exhaust fan 300mm sweep 1400 RPM totally enclosed heavy duty motor with die cast aluminium rotor suitabke for operation on 240 volt 50 HZ AC single phase supply including installation of exhaust fan in the existing opening, making good the damage as required.(Make Bajaj/Havells/Usha/C.G) (MR).
Wiring for circuit/sub main wiring along with earth wire with the following sizes of FR L.S. PVC insulated copper conductor, single core cable in surface/recessed steel conduit as required. a) 2x2.5 sq.mm + 1x2.5 sq. mm earth wire.
b) 2x6 sq. mm + 1x6 sq. mm earth wire
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor II level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and fixing 3 Seater Stainless Steel benches with backrest made out of SS 304 Grade materials, overall minimum dimension 1450x890x450 mm, sheet thickness will be 1.5mm and pipe thickness will be 2.0mm and dia. 38 mm. Turret punching or Laser cutting will be used for perforation.(weight approx. 40 Kg) make Godrej, Neelkamal, Durient, Jupiter only.
Providing & Fixing of 2 mm thick 0.30x0.15 Mt. Stainless steel plates on benches with name of Hon`ble area MLA and tighted with aluminium riviting on existing benches.
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.200 mm X 250 mm X 60 mm deep
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way, Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way (4 + 24), Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a). Single pole
Single pole and neutral
Triple pole
Providing and laying RMC of M-30 grade By using minimum 400kg of cement(43 grade, OPC) per cum of concrete in roads / streets manufactured in automatic RMC plant using coarse sand and graded stone aggregate of 20mm nominal size in appropriate proportion as per approved design criteria including transportation to site in transit mixer, including cost of admixture in recommended proportion as per IS9103 to accelerate/ retard setting of concrete to improve workability with out impairing strength and durability as per specification including spreading and compacting mechanically by using needle and surface vibratos, leveling to required slope & camber, finishing by floating & brooming with wire brushes etc. and curing including making provision for contraction / expansion, construction of cross / longitudinal joints of size 10mm wide 50mm deep by groove cutting machine, providing and filling joints with approved joint filler and sealants, etc. complete, as per direction of Engineer in-charge. (Cost of joint filler & sealants shall be paid for separately under relevant items). Note:- Cement content considered in M-30 is @ 400 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately M-30 RMC by using minimum cement @400 kg/cum. Cement concrete manufactured in automatic batching plant (RMC plant) including transportation to site in transit mixer.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.11 MB
BOQ_378918.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid