Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.6 LAccepted-AOC | ₹16.6 L Quoted ₹18.6 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹22.1 L+₹3.5 L (19.1%)Rejected-Finance | ₹22.1 L+₹3.5 L (19.1%) | L2 | Rejected-Finance Higher bid value |
| 3 | L3₹23.6 L+₹5.1 L (27.2%)Rejected-Finance | ₹23.6 L+₹5.1 L (27.2%) | L3 | Rejected-Finance Higher bid value |
| 4 | L4₹24.3 L+₹5.7 L (30.9%)Rejected-Finance KHAWAS BUILDING BELOW PAIZOR STADIUM GANGTOK 737101 SIKKIM | GANGTOK | EAST DISTRICT | SIKKIM | 737101 | ₹24.3 L+₹5.7 L (30.9%) | L4 | Rejected-Finance Higher bid value |
| Sl No | Description | Qty | Unit | M/S ANIL KUMAR THAKUR L2 | DHARMINDER SINGH L3 | MAHENDRA KHAWAS L4 | PREM LAMA L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5 M in wide and not exc. 1.5 M in depth for taking out or laying of under ground cable in soft / loose soil complete all as specified and as directed. | 150 | CUM | 250 ₹37,500 Lowest | 360 ₹54,000 | 350 ₹52,500 | 380.1 ₹57,015 |
| 2.00 | Returning, filling in including spreading, levelling, watering and well ramming in layers, not exceeding 25 cm thick in soil complete all as specified and as directed. | 145 | CUM | 145 ₹21,025 | 145 ₹21,025 | 175 ₹25,375 | 137.22 ₹19,896.9 Lowest |
| 3.00 | Removing surplus soil to a distance not exceeding 50 M and deposited at a level not exceeding 1.5 M above the starting point complete all as specified and as directed. | 5 | CUM | 225 ₹1,125 Lowest | 330 ₹1,650 | 320 ₹1,600 | 318.7 ₹1,593.5 |
| 4.00 | M&L for cutting the existing road / PCC / drain for taking out / laying of underground cable including necessary earthwork excavation and making good to match with the exisitng surface complete all as specified and with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) 100mm thick complete all as specified and as directed.
Note- (i)GI pipe shall be measured and paid separately.
(ii) Any damages made/caused to the HT/LT cables,water supply pipelines,OFC cables etc during the excavation works shall be made good by the contr as per original and GE Cost of the same is deemed to be included to be included in the unit quoted rate. | 24 | RM | 750 ₹18,000 | 900 ₹21,600 | 850 ₹20,400 | 401.1 ₹9,626.4 Lowest |
| 5.00 | M&L for 50mm dia bore galvanised iron light grade for cable protection and sealing both ends including taking out old pipe complete all as specified and as directed. | 12 | RM | 750 ₹9,000 | 840 ₹10,080 | 930 ₹11,160 | 446.4 ₹5,356.8 Lowest |
| 6.00 | M&L for 80mm dia bore galvanised iron light grade for cable protection and sealing both ends including taking out old pipe complete all as specified and as directed. | 12 | RM | 1,030 ₹12,360 | 1,275 ₹15,300 | 1,175 ₹14,100 | 752.2 ₹9,026.4 Lowest |
| 7.00 | Taking down LT Overhead ACSR conductor line complete all as specified and as directed. | 150 | KG | 29 ₹4,350 Lowest | 525 ₹78,750 | 300 ₹45,000 | 348.1 ₹52,215 |
| 8.00 | Dismantling insulators any type, any size complete all as specified and as directed. | 40 | EACH | 21 ₹840 Lowest | 40 ₹1,600 | 49 ₹1,960 | 49 ₹1,960 |
| 9.00 | Taking up/down existing defective cable of sizes 2/3/3.5/4 core 10 to 50 sqmm from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including relaying in same or different position/location complete all as specified and as directed. | 500 | RM | 23 ₹11,500 | 38 ₹19,000 | 21 ₹10,500 | 15 ₹7,500 Lowest |
| 10.00 | Laying,jointing, testing and commissioning of serviceable cable obtained from taking out in same or new location or position i.e. in trenches/on walls/floord/roof/ceiling etc of size 2/3/3.5/4 core 50 to 70 sqmm including necessary cable lugs, gland etc complete all as specified and as directed. | 200 | RM | 56 ₹11,200 | 140 ₹28,000 | 59 ₹11,800 | 53 ₹10,600 Lowest |
Tender Value
₹19.5 L
EMD Value
₹39,000
Closing Date
30 Sept 2025, 6:00 pmClosed
GE Gangtok
GE Gangtok New Mil Stn Gangtok Sikkim
REPAIR MAINT TO EXTERNAL ELECTRIC SUPPLY LT PANELS MCCBs EARTHING CABLES AND THEIR CONNECTED ITEM AT MS10 TO MS13 AND CONNECTED UNIT UNDER GE GANGTOK
2025_MES_721408_2
8358/A/E8
Open Tender
Miscellaneous Works
Works
182 days
GE Gangtok New Mil Stn Gangtok Sikkim
As per tender documents
8 documents required · 8 mandatory
₹500
GE Gangtok
₹39,000
Yes
14 Oct 2025
9 Sept 2025
2 Oct 2025
9 Sept 2025
30 Sept 2025
16 Sept 2025
Amount
Excavation in trenches not exceeding 1.5 M in wide and not exc. 1.5 M in depth for taking out or laying of under ground cable in soft / loose soil complete all as specified and as directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers, not exceeding 25 cm thick in soil complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50 M and deposited at a level not exceeding 1.5 M above the starting point complete all as specified and as directed.
M&L for cutting the existing road / PCC / drain for taking out / laying of underground cable including necessary earthwork excavation and making good to match with the exisitng surface complete all as specified and with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) 100mm thick complete all as specified and as directed. Note- (i)GI pipe shall be measured and paid separately. (ii) Any damages made/caused to the HT/LT cables,water supply pipelines,OFC cables etc during the excavation works shall be made good by the contr as per original and GE Cost of the same is deemed to be included to be included in the unit quoted rate.
M&L for 50mm dia bore galvanised iron light grade for cable protection and sealing both ends including taking out old pipe complete all as specified and as directed.
M&L for 80mm dia bore galvanised iron light grade for cable protection and sealing both ends including taking out old pipe complete all as specified and as directed.
Taking down LT Overhead ACSR conductor line complete all as specified and as directed.
Dismantling insulators any type, any size complete all as specified and as directed.
Taking up/down existing defective cable of sizes 2/3/3.5/4 core 10 to 50 sqmm from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including relaying in same or different position/location complete all as specified and as directed.
Laying,jointing, testing and commissioning of serviceable cable obtained from taking out in same or new location or position i.e. in trenches/on walls/floord/roof/ceiling etc of size 2/3/3.5/4 core 50 to 70 sqmm including necessary cable lugs, gland etc complete all as specified and as directed.
Supply & laying testing and commissioning in trenches or fixing on wall or passing through pipe or in cable ducts XLPE insulated PVC sheathed IS-7098 (Part-I), screened , PVC bedded and PVC tape sheathed galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm 2 core including cable lugs, glands, insulation tape etc complete all as specified and as directed.
All as per item No 11.00 here-in-above but size of 10 sqmm 4 core complete all as specified and as directed.
All as per item No 11.00 here-in-above but size of 16 sqmm 4 core complete all as specified and as directed.
All as per item No 11.00 here-in-above but size of 25 sqmm 4 core complete all as specified and as directed.
All as per item No 11.00 here-in-above but size of 35 sqmm 4 core complete all as specified and as directed.
All as per item No 11.00 here-in-above but size of 50 sqmm 3.5 core complete all as specified and as directed.
All as per item No 11.00 here-in-above but size of 70 sqmm 3.5 core complete all as specified and as directed.
M&L for straight through joint (Heat Shrinkable) for under ground PVC insulated and PVC sheathed armoured heavy duty XLPE cables with aluminium conductor including jointing kit, including making joints for the cable of size 10 to16sqmm 3/3.5/4 core cables including testing complete all as specified and as directed.
All as per item No 18.00 here-in-above but size of 25 - 50 sqmm 3/3.5/4 core complete all as specified and as directed.
All as per item No 18.00 here-in-above but size of 70 - 150 sqmm 3/3.5/4 core complete all as specified and as directed.
All as per item No 18.00 here-in-above but size of 185 - 300 sqmm 3/3.5/4 core complete all as specified and as directed.
S&F in replacement MCCB 250 Amp,4 pole, 36 KA microprocessor based of 50Hz,415 V adjustable type including necessary cable lugs & wire etc complete all as specified and as directed.
All as per item No 22.00 here-in-above but 250 Amps, 3 pole, 25 KA thermal magnetic based complete all as specified and as directed.
All as per item No 22.00 here-in-above but 200 Amps, 4 pole, 25 KA thermal magnetic based complete all as specified and as directed.
All as per item No 22.00 here-in-above but 100 Amps, 4 pole, 16 KA thermal magnetic based complete all as specified and as directed.
All as per item No 22.00 here-in-above but 63 Amps, 4 pole, 16 KA thermal magnetic based complete all as specified and as directed.
M & L for servicing of LT panels/Feeder piller box of any size by complete cleaning of panel and bus bar at chamber with CTC solution, and welding the door using arc welding and fixing of haevy duty hinges/Locking Handles/latches and necessary nut, bolts, washers/Leads/busbar and made it completely functional for open/close and incl checking of incoming and out going cable connections, Re-fixing of existing Cables, ACBs & MCCBs, and repair to connected PCC foundation and frame works, rewiring of control and power wiring of LT panel/Feeder with suitable size of FRLS cable but not less than 1.5 sqmm, replaceing of various unserviciable ON/OFF switches, lugs/Gland/Base plate/indicating Lamp/CT Coil etc making the panel fully functional including numbering the LT panel/feeder box and marking on panels (incoming and locations of outgoing MCCBs), to the satisfaction of Engr-in-Charge complete all as specified and as directed.
M&L for painting of LT panel board of sqmtr not less than 20 sqmtr by spraying two coats of epoxy based weather proof paint of ivory/Red colour over a coat of red oxide primer after cleaning of rusty panel surface of both inside/ outside by emery paper and necesary preparation of old steel surface complete all as specified and as directed.
M&L for painting of LT panel board of sqmtr not less than 10 sqmtr by spraying two coats of epoxy based weather proof paint of ivory/Red colour over a coat of red oxide primer after cleaning of rusty panel surface of both inside/ outside by emery paper and necesary preparation of old steel surface complete all as specified and as directed.
M & L for Earthing complete with galvanized earth plate electrode 600 x 600 x 6 mm buried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to galvanised iron strip 25x4mm dia means of nut, bolts and washers made out of galvanized iron mild steel and 40 mm dia GI pipe "light grade" for protection of earth lead/Strip and connected to control board or main switch or as directed by Engineer -in-Charge including earthing pit in PCC (1:3:6) type C1 for chamber & Pre-cast RCC cover of size 380 x 380 x 40 mm with one handle made out of 8 mm dia round bar, 20 mm dia GI pipe light grade for watering funnels , wire mesh and provided charcoal or coke of alternative layers of 15 cm including necessary earth work complete all as specified and as directed. Note- Rate quoted included the cost of earthwork , GI protection & GI strip from earthpit to LT panel upto 15 mtr.
Supply and fix in replacement of LT CTs copper wound capacity as per site requirement complete all as specified and as directed.
Supply , fixing and commissioning Design verified as per IS /IEC-61439-1&2 LT Panel outdoor/ LT Pillar Box by CPRI approved manufactures of comprising of the following all as directed by removing the old existing panel complete with out damaging the existing floor / cable ducts at secondary sub station complete all as specified and as directed. Note: The details of LT Panel board have been given against Particular Specification Clause No 60.9 to 60.9.7 of this tender.
Supply , fixing and commissioning Design verified as per IS /IEC-61439-1&2 LT Panel outdoor/ LT Pillar Box by CPRI approved manufactures of comprising of the following all as directed by removing the old existing panel complete with out damaging the existing floor / cable ducts at secondary sub station complete all as specified and as directed. Note: The details of LT Panel board have been given against Particular Specification Clause No 60.10 to 60.10.7 of this tender.
Supply and laying of DWC pipe,ISI marked in trenches or in cable ducts or fixed on walls using clamps along with all accessories like socket,bend,couplers etc confirming to IS 14930,part-II complete with fitting cutting,jointing etc of size 40 mm outer dia complete all as specified and directed by Engr-in-Charge
Supply and laying of DWC pipe,ISI marked in trenches or in cable ducts or fixed on walls using clamps along with all accessories like socket,bend,couplers etc confirming to IS 14930,part-II complete with fitting cutting,jointing etc of size 50 mm outer dia complete all as specified and directed by Engr-in-Charge
Supply and fix in repairs MCB of 4 pole of 63 Amps, 25 KA,415 volt , 10KA complete with connection ,testing and commissioning complete all as specified and as directed.
Supply and fix in repairs isolator of 3 pole of 63 Amps, 25KA 415 volt, 10KA complete with connection ,testing and commissioning complete all as specified and as directed.
Supply and fix in repairs isolator of 3 pole of 100 Amps, 25 KA 415 volt, 10KA complete with connection ,testing and commissioning complete all as specified and as directed.
Supply and fix in repairs MCB of 2 pole of 63 Amps,25 KA, 240 volt, 10KA complete with connection ,testing and commissioning complete all as specified and as directed.
Supply and fix in repairs MCB of 2 pole of 40 Amps,10 KA, 240 volt, 10KA complete with connection ,testing and commissioning complete all as specified and as directed.
S&F of street light terminal boxes made out with SMC material, shock & dust proof of inside size 300x200x105mm as per IS and including 20 Amp, TPN busbar fixed on insulators, 01 No 10Amp, SP MCB, earth termination with nuts & bolts and including 02 sets of flat iron 25x6mm clamps of suitable size with nuts, bolts and washers including two coats of aluminium paint over a coat of primer on exposed steel surfaces complete all as specified and as directed.
M&L for providing PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggr) in foundations complete all as speicified and as directed.
M& L for preparation of old painted surfaces of street light steel tubular poles above GL/Copping including cross section channels,flat iron clamps by srapping with wire brush applying one coats of aluminium paint including pole numbering using three layer of radium strip of min 4-5 inch wide(Yellow,Green,Blue) on each pole using printer letter complete all as specified and as directed. Note-:(i) Ladders scaffolding,safety belts etc required for execation of works shall be arranged by contractor & cost of the same is deemed to be included in the unit rate quoted rates. (ii) Contractor shall be fully responsible for the safety aspects of the people enagaged by him & any issues(if any) arising during the work shall be dealt by the contractor& the Dept shall be no way responsibile whatever.
S&F in repair 1.5 sqmm 3 core PVC insulated flexible copper conductor wire from street light to terminal box drawn through MS pipe/PVC conduit or as indicated in other locations complete all as specified and as directed.
M/S ANIL KUMAR THAKUR (BID ID -3432069)
DHARMINDER SINGH (BID ID -3432981)
MAHENDRA KHAWAS (BID ID -3433525)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .