| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-Finance A 8 SAKHARAM GANESH DAUSKAR SARANI KOLKATA 700 025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | L1 | Accepted-Finance 1st lowest | |
| 2 | L2₹15.3 L+₹3,226 (0.21%)Rejected-Finance 8 TOWNSHEND ROAD KOLKATA 700025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | L2 | Rejected-Finance 2nd lowest | |
| 3 | L3₹15.3 L+₹5,785 (0.38%)Rejected-Finance | L3 | Rejected-Finance 3rd lowest |
Tender Value
Refer Docs
EMD Value
₹30,564
Closing Date
4 Sept 2024, 10:55 amClosed
Executive Engineer, PWDte
Bankura
SITC of Air Conditioning system along with allied electrical works at Nazir Khana in the District Judges Building, Civil Judge ( Jr.Divn. ) 1st Court and 2nd Court in the Judicial Magistrates Court Building in the District of Bankura.
2024_WBPWD_737196_1
WBPWDTE/EE/BED/NIQ_109/Q of 2024-25-2nd call tender
Open Tender
ELECTRICAL WORKS ORG
Item Wise
45 days
Judicial Magistrates Court Building
Please refer Tender documents.
3 documents required · 3 mandatory
₹30,564
28 Oct 2024
21 Aug 2024
6 Sept 2024
22 Aug 2024
4 Sept 2024
22 Aug 2024
Amount
Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make-RR Kabel / Havells /Gloster or as per direction of EIC ] 4 Core 25 Sq. mm [ NS ]
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish (i)From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc.
Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire (i) Up to 50 sqmm.
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS. (i) 4 Core 25 Sq. mm
Supply and fixing stainless steel water proof looping cable box of size 260 mm x 200 mm x 115 mm having hinged cover with rubber gsket lining and din rail channel arrangement inside the loop bos for attaching four pole isolator and making necessary connection.
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand/ABB /Siemens/ L&T) as per direction of EIC. ] 63 A FP
Supply of 7.5TR capacity concealed type Split Air Conditioner of rated cooling capacity of 90000 BTU/hr. with 3Nos. Twin rotary compressor with Green Refrigerant(R407C/R32/R401A),Designed for 52⁰C, 3nos. IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU of rated power supply-400V-3ph-50Hz. Air-flow/per IDU:- 1000CFM. (Make: Hitachi /Ogeneral/Mitshubishi)
Supply of 5TR capacity concealed type Split Air Conditioner of rated cooling capacity of 90000 BTU/hr. with 2 Nos. Twin rotary compressor with Green Refrigerant(R407C/R32/R401A),Designed for 52⁰C, 3nos. IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU of rated power supply-400V-3ph-50Hz. Air-flow/per IDU:- 1000CFM. (Make: Hitachi /Ogeneral/Mitshubishi)
Lifting & shifting incl. Erection & Commissioning Charges for 7.5/5.0 Tr Concealed Split Air Conditioner as per direction of E.I.C.
Copper Refrigeration pipe line for Liquid Line (3/8" OD with 0.6 mm thick) with proper supports & brackets for 7.5/5.0 Tr Concealed Split air Conditioner(make: Ryoku/Nippon)
Copper Refrigeration pipe line for Suction Line (7/8" OD with 1 mm thick) with proper supports & brackets( per direction of E.I.C.) for 7.5/5.5 Tr Concealed Split air Conditioner (make: Ryoku/Nippon)
Supply & Fixing Pipe Insulation for Liquid Line (3/8" OD with 9 mm thick) with proper insulating for 7.5/5.0 Tr Concealed Split air Conditioner(make: Accroflex/Suprime)
Supply & Fixing Pipe Insulation for Suction Line (7/8" OD with 9 mm thick) with proper Insulating ( per direction of E.I.C.)for 11.0/8.5/5.5 Tr Concealed Split air Conditioner (make: Accroflex/Suprime)
Control Cabling from Condensing Unit to Control Panel 4 Core 1.5sq. mm. Communication Cable for 5.0/7.5 Tr Concealed Split (Make : Polycab/KEI/Finolex)
Supply & laying PVC Drain Pipe 32mm dia(with 3mm/4mm insulation ) with proper supports & brackets as per direction E.I.C. (Make: Suprime/Oriplast)
S/F of aluminium continuous grill.(Make: Air Kolkata/Primier)
Supply & Fixing of IDU & Duct Covered with 12.5mm Gypsum BoardCoplete with linkages, levers, fittings, supports, all accessories any other item required to make the system complete, finished with compound as so match with paint as per direction of E.I.C.
Chrages for Trap door with fire redant 6mm PVC Board Complete with linkages, levers, fittings, supports, all accessories for IDU Maintenance as per direction of E.I.C.
Supply and fixing flexible double canvass connection for concealed split air-conditioners.
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run.
Supplying, fabrication & fixing 3 Nos. M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) of 1m length for making Base Frame for installation of outdoor unit of 7.5.Tr/5.0 Tr split AC incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with 2 Nos. horizontal angle of 50 mm x 50 mm x 6 mm of 1.2m length with Platform & Baricated as per Direction of E.I.C.
SKY DECORATIONS PRIVATE LIMITED (BID ID -5499295)
NAYEE DISHA PROJECTS (BID ID -5522644)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .