Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance 16 2 212 218 GOVARDHAN BHUVAN CHS KHETHWADI MAIN LANE KHETHWADI MUMBAI MAHARASHTRA 400004 | MUMBAI | MAHARASHTRA | 400004 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
Closing Date
22 Dec 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
ASSTT PURCHASE OFFICER
CPU 1ST FLOOR V S BHAVAN ANUSHAKTINAGAR MUMBAI 94
Insulation sheet
2022_DPS_727202_1
DPS/CPU/04/D4/4310
Open Tender
Consumables- Raw materials
Item Rate
60 days
SO CSU BARC TROMBAY MUMBAI
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
Exempted
23 Dec 2022
5 Dec 2022
23 Dec 2022
5 Dec 2022
22 Dec 2022
5 Dec 2022
19mm EPDM Insulation Sheet with Aluminum Foil It should be a closed cell flexible elastomeric foam made from EPDM rubber. The material shall have low thermal conductivity and high Water vapour diffusion resistance. It should be CFC/ HCFC free and dust and fiber free. The Specifications for EPDM Sheet is as below: - Cell Structure- Closed Cell, Density (g/cm3)- 50±20% g/m3, Service Temperature – (-)50* C to 125*C, Thermal Conductivity- ≤ 0.031 W/m K at -18*C, ≤ 0.035 W/m K at 24*C, Flammability- Class V-0, Flame Spread and Smoke Density Test - Class A, Smoke and Toxity Test Passed, Rate of Burning – Passed, Water absorption (%) (Max)- 5% by weight, Water Vapour diffusion resistance index - >7000(For 25mm thickness), Resistance to fungi and bacteria- Zero growth, Ozone Resistance- No cracks, Dimensional Stability – max (-) 6%, Compression strength- 0.49 kg/cm2.
ID-60mm, 19mm thick EPDM Insulation Tubes with Aluminum Foil Dimension- ID- 60mm, Thickness of tube -19mm , Thickness of alumium foil- (±)1mm thick. It should be a closed cell flexible elastomeric foam made from EPDM rubber. The material shall have low thermal conductivity and high Water vapour diffusion resistance. It should be CFC/ HCFC free and dust and fiber free. The Specifications for EPDM Sheet is as below: - Cell Structure- Closed Cell, Density (g/cm3)- 50±20% g/m3, Service Temperature – (-)50* C to 125*C, Thermal Conductivity- ≤ 0.031 W/m K at -18*C, ≤ 0.035 W/m K at 24*C, Flammability- Class V-0, Flame Spread and Smoke Density Test - Class A, Smoke and Toxity Test Passed, Rate of Burning – Passed, Water absorption (%) (Max)- 5% by weight, Water Vapour diffusion resistance index - >7000(For 25mm thickness), Resistance to fungi and bacteria- Zero growth, Ozone Resistance- No cracks, Dimensional Stability – max (-) 6%, Compression strength- 0.49 kg/cm2.
ID-35mm, 19mm thick EPDM Insulation Tubes with Aluminum Foil Dimension- ID- 35mm, Thickness of tube -19mm , Thickness of alumium foil- (±)1mm thick. It should be a closed cell flexible elastomeric foam made from EPDM rubber. The material shall have low thermal conductivity and high Water vapour diffusion resistance. It should be CFC/ HCFC free and dust and fiber free. The Specifications for EPDM Sheet is as below: - Cell Structure- Closed Cell, Density (g/cm3)- 50±20% g/m3, Service Temperature – (-)50* C to 125*C, Thermal Conductivity- ≤ 0.031 W/m K at -18*C, ≤ 0.035 W/m K at 24*C, Flammability- Class V-0, Flame Spread and Smoke Density Test - Class A, Smoke and Toxity Test Passed, Rate of Burning – Passed, Water absorption (%) (Max)- 5% by weight, Water Vapour diffusion resistance index - >7000(For 25mm thickness), Resistance to fungi and bacteria- Zero growth, Ozone Resistance- No cracks, Dimensional Stability – max (-) 6%, Compression strength- 0.49 kg/cm2.
EPDM Tape Closed cell, elastomeric EPDM thermal insulation material density: 50kg/m ±20%, ASTM D-1667, Color: Black, Thermal Conductivity: 0.04 W/m·k at 24°C (ASTM C-177), Water Vapor Permeability: 0.17 x 10 kg/Pa·m·s (ASTM E-96), Water Absorption: Max 5% by weight (ASTM D-1056), Temperature Range: -29°C to +93°C Size: 3mm(T) x 50mm (W) x 9.1m (L) ±3%
VARDHAMAN ENGINEERING CORPORATION
sharma engineering works
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .