Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.9 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹27.2 L+₹30,576 (1.14%)Rejected-Finance SHARADA SMRITI H NO 840 VINAYAK KATHE ALI KEGAON ROAD URAN NAVI MUMBAI 400702 | RAIGAD | MAHARASHTRA | 400702 | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | L3₹28.0 L+₹1.0 L (3.88%)Rejected-Finance 702 A1 SHREE PRASAD TAWADEWADI SHREE DATTAGURU PARK KUMBHARWADA URAN DIST RAIGAD MAHARASHTRA 400 702 | URAN | RAIGAD | MAHARASHTRA | 400702 | L3 | Rejected-Finance BEING NOT L1 | |
| 4 | L4₹28.5 L+₹1.5 L (5.66%)Rejected-Finance | L4 | Rejected-Finance BEING NOT L1 | |
| 5 | L5₹29.7 L+₹2.8 L (10.4%)Rejected-Finance | L5 | Rejected-Finance BEING NOT L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
10 Jan 2022, 6:00 pmClosed
GE NW KARANJA
NAVAL STATION KARANJA, URAN, RAIGAD, MAHARASHTRA
REPAIR CLEANING OF SEWAGE SYSTEM INCLUDING SEPTIC TANKS UNDER AGE BR II AREA AT NAVAL STATION KARANJA
2021_MES_496403_1
8469/E8
Open Tender
Civil Works
Item Rate
330 days
GE NW KARANJA
REPAIR CLEANING OF SEWAGE SYSTEM INCLUDING SEPTIC TANKS UNDER AGE BR II AREA AT NAVAL STATION KARANJA
8 documents required · 8 mandatory
₹500
Yes
GE NW KARANJA
₹60,000
Yes
3 Feb 2022
21 Dec 2021
12 Jan 2022
21 Dec 2021
10 Jan 2022
4 Jan 2022
21 Dec 2021 - 4 Jan 2022
Amount
Demolition and breaking up 150mm dia drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar and including reinforced concrete pipes 150mm bore, class NP2, laid and jointed complete with collars joints with concrete bed for 150 mm dia pipe including packing under and haunching against the sides of pipe after they are laid and tested in cement concrete 1:4:8 type D2 usingn 40mm graded crushed stone aggregate complete all as specified and directed.
Demolition and breaking up 200mm dia drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar and including reinforced concrete pipes 200mm bore, class NP2, laid and jointed complete with collars joints with concrete bed for 200 mm dia pipe including packing under and haunching against the sides of pipe after they are laid and tested in cement concrete 1:4:8 type D2 usingn 40mm graded crushed stone aggregate complete all as specified and directed.
Demolition and breaking up 150mm dia drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar and including Salt Glazed Stone Ware (SGSW) drain pipe, grade ‘A’ 150 mm bore laid in trenches and jointed including packing under and haunching against the sides of pipe after they are laid and tested in cement concrete 1:4:8 type D2 usingn 40mm graded crushed stone aggregate complete all as specified and directed.
Cutting into the existing manhole for connecting new drain pipe 150mm internal dia metre making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B1 smooth finished even and smooth benching as required.
Cutting into the existing manhole for connecting new drain pipe 200mm internal dia metre making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B1 smooth finished even and smooth benching as required.
Excavation in trenches n'exc 1.5m wide and n'exc 1.5 mtr deep for sewage pipe line and manhole etc and getting out in soft/loose soil.
M&L for cement concrete 1:4:8 type D2 using 40mm graded aggregate as in foundation.
Returning, filling incl spreading, levelling watreing and well rammingh in layers n'exc 25cm in soft/loose soil for sewage pipe line manholes sides and cleaning the site all as specified and directed by Engineer-in-charge.
Removing excavated material to a distance not exceeding 50m and depositing as directed by Engineer-in-charge.
Demolition of reinforcement concrete of any description and in any position for manhole cover slab.
M&L Providing precast cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in cover slabs and similar articles including necessary moulds/formwork set in cement mortar (1:6) complete all as specified
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
S&F 100mm cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fix to wall or in floors including dismantling of cast iron or reinforced concrete drain pipes of 100mm dia, jointed in cement mortar and taking out of trenches complete all as specified and directed.
S&F 75mm cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fix to wall or in floors including dismantling of cast iron or reinforced concrete drain pipes of 100mm dia, jointed in cement mortar and taking out of trenches complete all as specified and directed.
Demolition of brick work or stone/boulder, masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but exceeding ashlar facing and pre-cast concrete articles complete all as specified and as directed.
All as per srl item No. 15 here- in-before but pre-cast concrete block walling complete all as specified and as directed.
M&L for pre-cast cement concrete block masonry with solid blocks in 10cm in width in type B1 (1:2:4) and setting in mortar (1:6) complete all as specified and as directed.
M&L Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 metre means radius built in cement mortar 1:6 complete all as specified and as directed.
M&L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted built in cement mortar 1:6 complete all as specified and directed.
Taking down cement plaster on brick walls or stone walls etc including raking out joint, hacking for key, scrubbing down with water etc including removing debries directed for a distance max upto 500m complete all as specified.
M&L for rendering 15 mm thick on fair faces of brick/concrete surfaces cement plaster in CM (1:4) , with integral water proofing compound as per manufacturers instructions finished even and smooth without using extra cement, complete all as specfified and directed.
M & L rendering 15mm thick on fair faces of brick work or concrete surfaces of walls in cement mortar 1:6, with integral water proofing compound as per manufacturers instructions finished even and smooth (with out using extra cement) complete all as specified.
M & L for preparation of new or previously untreated plastered surfaces of walls and applying two coats of acrylic antifungal paint exterior grade paint plain or camouflage pattern on one coat of primer complete all as specified and as directed
M&L cement concrete 1:2:4 tye B1 using 20mm graded stone aggregate in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed
Supply only Integral water proofing compound all as specified and directed.
Taking down AC/PVC rain water ,soil & waste pipe etc (any size and pattern), from trench/ wall /ceiling including fittings & fixture complete all as specified and as directed
S&F PVC (SWR) pipes single socketed in any length with rubberring joints fixed to wall/floors 110mm bore including suitable clamps etc complete all as specified and directed.
S&F PVC (SWR) pipes single socketed in any length with rubberring joints fixed to wall/floors 75mm bore including suitable clamps etc complete all as specified and directed.
S&F PVC (SWR) pipes single socketed in any length with rubberring joints fixed to wall/floors 160mm bore including suitable clamps etc complete all as specified and directed.
S&F PVC (SWR) bends any radius 75mm bore.
S&F PVC (SWR) bends any radius 110mm bore.
S&F PVC (SWR) branch piece single (single 'Y') equal or unequal 110mm bore.
S&F PVC (SWR) branch piece double (single 'Y') equal or unequal 110mm bore.
S&F PVC(SWR) junction single (single T') equal or unequal 110mm bore.
S&F PVC(SWR) junction double (double T') equal or unequal 110mm bore.
S&F Cast iron nahani trap 100mm dia, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed
S&F PVC (SWR) floor trap 75mm dia, plain with grating including jointing with solvent cement complete all as specified and directed
S&F in repairs vitreous china water closet (Squatting pan) “Orissa” pattern of size 580 x 440 mm white with integral foot rest and ‘P’ trap (excluding flushing cistern) but including PVC flush pipe and provision of lime concrete bedding complete all as specified and directed.
S&F vitreous china wash down water closet pan (Pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) fixed as in repairs complete all as specified and directed.
Cleaning of septic tank, soak pit/well, manholes etc by blocking internally the inlet with appropriate wooden plug and handling pumping and water from septic tank, soak well/pit,and manholes and scoping out sludge organic material inorganic solid or semisolid materials, and removing in a closed container of capacity 3000 ltr to a distance exc 5.00km from the starting point and filling into the shallow pits n'exc 2.00 mtr deep and removal of wooden plug and chanelling the water back all as specified and in a manner as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
S&F Coloured Non Skid ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed in CM(1:6) complete all as specified and directed
S&F Coloured Glazed ceramic tiles in vertical surfaces 350x250mmx7mm/450x350x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick plaster in CM(1:4) on fair face of brick or concrete surface complete all as specified and directed
Demolition of cement concrete in ground floor and paving not exceeding 15cm thick below or above ground level un re-inforced complete all as specified and directed. .
M&L 100mm thick cement concrete 1:2:4 type B-2 using 40mm graded stone aggregate as in paving , hardstanding and similar works complete all as specified and directed
M&L 75mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate finished even and smooth witout using extra cement as in plinth protection.
Surface dressing in any type of soil not exc 30 cm deep and averaging 15 cm deep in foul condition for removing heaps of wastes, cleaning of flora, fauma, follage and bushes around septic tanks, soakage well and man holes, removing debries/heaps of bushes etc from vicinity and depositing at a place where complete all as specified and as directed.
M&L PCC 1:4:8 type D2, using (40 mm graded agg) ,100 mm thick as in sub base of flooring all as specified & directed
M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick set jointed and pointed in neat cement slurry in floors with in equal proportions & pigments with red and yellow colour over including 15mm thick screed bed in CM 1:6 complete all as specified and directed
M&L for precast moulded reinforced cement concrete factory made precast moulded and vibro compacted manhole covers with necessary handles of size 900X450X100 mm medium duty confirming to IS 12592 -2002 placed in position wherever required all as directed. Note: Manhole cover shall be of "BMC pattern" precast slab as in RMC M30 obtained from approved manufacturer as directed by GE.
Cleaning of blockage of existing sewage system and plumbing system (Comprising of sewer line in CI, SGSW, PVC/UPVC or SG pipes), house connection from WC, bath, Kitchen etc including gully traps, floor/Nahani traps, CI Pipes and plumbing work etc of any description and in any position below or above ground level, located in different situations to remove of the solid or liquid wastage to make the entire system functional as directed by Engr-in-charge. Note :- (i) Contractor will deploy two SDA Mazdoor, daily to attend day to day complaint (excluding Sunday) as mentioned above. SDA Mazdoor will report daily at AGR B/R -II (NW) Karanja Sub division at 0900 hrs and depart 1730 hrs after attending all compliants (Time inclus 30 minutes for lunch). In case of non attending compliants in same day, recovery @ Rs.500.00 per complints will be recovered from contractor and in case of non deployment of SDA Mazdoor recovery @ Rs.1000 per day shall be made from the contractor. septic tank /soakage well of any depth & description including takine contractor. Complete all as specified and as directed by Engr-in-charge.
DIGITAL SERVICES
Sagar Electricals
KD CONSTRUCTION
S N TRADERS
INDIA ENGINEERS AND CONTRACTORS
BALAJI TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .