Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.3 LAccepted-AOC 1442 1 NANADANPURA BABINA CANTT TEHSIL DISTT JHANSI UP | BABINA | JHANSI | UP | L1 | Accepted-AOC Lowest BIdder | |
| 2 | L2₹37.0 L+₹25,985 (0.71%)Rejected-Finance 102 VYAS COLONY NEAR AIR FORCE JODHPUR 342011 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342011 | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹38.4 L+₹1.7 L (4.74%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹38.8 L+₹2.1 L (5.68%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹39.5 L+₹2.8 L (7.64%)Rejected-Finance HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | L5 | Rejected-Finance Other than Lowest |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
21 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NASIRABAD
Garrison Engineer, Military Engineer Services, Nasirabad, Pin 305601
REPAIRS TO MAIN DBS AND SERVICE CABLES OF NASIRABAD MIL STN UNDER GE NASIRABAD
2023_MES_629638_1
8384/E8
Open Tender
Civil Works
Item Rate
335 days
GE Nasirabad
MES Contractor enlisted as Class D and above and category b i having deposited Standing Security of Rs 1,00,000.00 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
6 documents required · 6 mandatory
₹500
Yes
₹90,000
Yes
27 Jan 2024
23 Nov 2023
23 Dec 2023
23 Nov 2023
21 Dec 2023
7 Dec 2023
23 Nov 2023 - 7 Dec 2023
Amount
Disconnecting of unserviceable sub main wiring/service connection of any size and including steel/PVC conduit and accessories and removing from site and making good disturbed surfaces complete all as specified and directed.
Disconnecting electric connections and taking down old unserviceable MCB SPN/SP and DB's of any capacity and removing from site complete all as specified and directed.
Disconnecting electric connections and taking down old unserviceable MCB TPN and DB's of any capacity and removing from site complete all as specified and directed.
Disconnecting of unserviceable service connection of any size and removing from site and making goo the disturbed surface complete all as specified and directed.
M & L for submain wiring with two single core, PVC insulated, unsheathed, FRLS, 1100 volts grade 6 Sqmm multi stranded copper conductor cable drawn through and including 25 mm dia PVC non metallic rigid conduits & conduits accessories, concealed in wall/ roof/ ceiling ncluding one run of green colour earth continuity conductor with 6 Sqmm multi stranded copper conductor cable complete all as specified and directed. Note :- Two run of single core cable, one run of earth continuity conductor & conduit with conduit accessories shall be measured as one unit length. Make of wire- Finolex/KEI/Havells Make of PVC conduit - Polycab/ Finolex/Legrand-MDS
M & L for submain wiring with two single core, PVC insulated, unsheathed, FRLS, 1100 volts grade 6 Sqmm multi stranded copper conductor cable drawn through existing concealed conduits & conduits accessories, concealed in wall/ roof/ ceiling ncluding one run of green colour earth continuity conductor with 6 Sqmm multi stranded copper conductor cable complete all as specified and directed. Note :- Two run of single core cable & one run of earth continuity conductor shall be measured as one unit length. Make of wire- Finolex/KEI/Havells
M & L for submain wiring with two single core, PVC insulated, unsheathed, FRLS, 1100 volts grade 10 Sqmm multi stranded copper conductor cable drawn through existing concealed conduits & conduits accessories in wall/ roof/ ceiling ncluding one run of green colour earth continuity conductor with 10 Sqmm multi stranded copper conductor cable complete all as specified and directed. Note :- Two run of single core cable, one run of earth continuity conductor & conduit with conduit accessories shall be measured as one unit length. Make of wire- Finolex/KEI/Havells
M & L for submain wiring with two single core, PVC insulated, unsheathed, FRLS, 1100 volts grade 10 Sqmm multi stranded copper conductor cable drawn through and including 25 mm dia PVC non metallic rigid conduits & conduits accessories, concealed in wall/ roof/ ceiling ncluding one run of green colour earth continuity conductor with 10 Sqmm multi stranded copper conductor cable complete all as specified and directed. Note :- Two run of single core cable & one run of earth continuity conductor shall be measured as one unit length. Make of wire- Finolex/KEI/Havells Make of PVC conduit - Polycab/ Finolex/Legrand-MDS
S&F of MCB distribution board single pole & neutral IP-43 double door metal, 240 volt made out of CRCA sheet steel , factory made powder coated with insulated bus bars , shrouded neutral bars, earth bars , made out of sheet steel enclosure, recessed type, factory made powder coated suitable for housing MCB's complete all as specified and directed. Make: Legrand/Schneider/Seimens Note: MCB DB and MCB SP/SPN will be of same make.
All as per description of serial item No. 9.00 above but 08 Ways, 240 volts SPN
All as per description of serial item No. 9.00 above but 12 Ways, 240 volts SPN
All as per description of serial item No. 9.00 above but 04 Ways, 240 volts SPN
S&F of MCB distribution board triple pole & neutral IP-43 double door metal, 4 way ,415 volt made out of CRCA sheet steel , factory made powder coated with insulated bus bars , shrouded neutral bars, earth bars , made out of sheet steel enclosure, recessed type, factory made powder coated suitable for housing MCB's complete all as specified and directed. Make: Legrand/Schneider/Seimens Note: MCB DB and MCB SP/SPN will be of same make.
S&F distribution board triple pole & neutral, vertical, IP-43, double door metal, 4 way, made out of CRCA sheet steel, factory made power coated with insulated vertical phase bus bars, shrouded neutral bars, earth bars, colour coded interconnecting wire set, blanking plates suitable for up to 125amp MCCB's as incomer and MCB's SP/TP as outgoing complete all as specified and directed. Make : Legrand/Schneider/Seimens Note: MCB DB, MCCB and MCB's will be of same make.
S&F MCB, single pole, 240 volt, 10KA, 6 to 32 Amps, conforming to IS 8828 of 1996, curve 'C' complete all as specified & directed. Make : Legrand (DX-3), Schneider (Acti-09), Siemens ( Betagard)
S&F MCB, single pole, 240 volt, 10KA, 63 Amps, conforming to IS 8828 of 1996, curve 'C' complete all as specified & directed. Make : Legrand (DX-3), Schneider (Acti-09), Siemens ( Betagard)
S&F MCB, single pole and neutral, 240 volt, 10 KA, 32 Amps conforming to IS 8828 of 1996 curve 'C' complete all as specified & directed. Make :- Make : Legrand (DX-3), Schneider (Acti-09), Siemens ( Betagard)
S&F MCB single pole and neutral 240 volt 10 KA, 63 Amps conforming to IS 8828 of 1996 curve 'C' complete all as specified & directed. Make : Legrand (DX-3), Schneider (Acti-09), Siemens ( Betagard)
S & F MCB, triple pole and neutral , 63 Amp, 415 Volts with breaking capacity 10 KA, ISI marked complete all specified and directed. Make : Legrand (DX-3), Schneider (Acti-09), Siemens ( Betagard)
S & F MCB, triple pole and neutral , 100 Amp, 415 Volts with breaking capacity 10 KA, ISI marked complete all specified and directed. Make : Legrand (DX-3), Schneider (Acti-09), Siemens ( Betagard)
S & F in repair MCCB, 4 pole, 100 Amp, 415 Volts with breaking capacity 25 KA, thermal magnetic release type, Ics=100 % Icu, with adjustable overload setting and adjustable short circuit setting , including spreader terminals and phase barriers complete all as specified and directed. Make- Legrand/Siemens/Scneider/Havells
S & F PVC insulated twin core multi-stranded aluminium conductor 16 sqmm, 1100 volts, heavy duty, served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hangers not more than 1 metre apart & passing through service bracket including 4mm dia GI wire with one twin core cable complete all as specified and directed
All as per item ser No 19 here-in-before but of size 10 sqmm twin core
All as per item ser No 19 here-in-before but of size 6 sqmm twin core
M & L for earthing complete with GI earth plate electrode 60 cm x 60 cm x 6.00mm thick, buried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to GI lead wire 4.00mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electric plate No 3 of SSR Part-I connected to continuous earth wire on main switch board all as specified or indicated and testing on completion including provision of earth wire protection by 15mm dia medium grade GI pipe and watering pipe shall be 20mm bore, medium grade including excavation & earth work in any type of soil & disposal of soil, chamber of PCC 1:3:6 type C-1 with 20mm graded stone aggregate, RCC 1:2:4 type B-1 cover, reinforced with 8mm TMT bars 100mm c/c both ways with handle made out of 8mm dia bars, watering arrangement with funnel and wire mesh completed all as specified and directed. Note : (i) The unit rate includes for GI protection pipe of 15 mm dia and GI wire from top of earth plate upto 7.5 meter above ground level. (ii) GI wire beyond 7.5 mtr shall be measured & paid seperately under respective item of BOQ
M & L for earthing complete with galvanized steel earth plate electrod 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate not less than 1.50 metre below normal ground level connected to galvanized strip 32 x 6 mm by means of nuts, bolts, check nut and washer of galvanized steel all as shown on electrical plate No 3 of SSR Part - I connected to continuous earth wire on main switch board all as specified or indicated and testing on completion including provn of earthing wire protected by 40mm bore medium grade pipe and watering pipe shall be 20mm bore medium grade including excavation & earth work in any type of soil & disposal of soil, chamber of PCC 1:3:6 type C-1 with 20mm gradred stone aggregate, RCC 1:2:4 type B-1 cover reinforced with 8mm TMT bars 100mm c/c both ways with handle made out of 8mm dia bars, watering arrangement with funnel and wire mesh completed all as specified and directed. Note : (i) The unit rate includes for GI protection pipe of 40 mm dia and GI strip from top of earth plate upto 7.5 meter above ground level. (ii) GI strip beyond 7.5 mtr shall be measured & paid seperately under respective item of BOQ
Supply & fix in repair house service bracket, hook type complete with 3 mtr long GI pipe 40mm bore, medium grade, 02 No 90 degree bracket, MS hook & stay or guy complete all as specified & directed.
S & F GI lead wire 4.00 mm dia as earth continuity conductor beyond 7.5 mtr f fixed to wall or burried in ground or drawn in pipe complete all as specified & directed.
Supply and fix GI strip 32x6 mm as earth continuity conductor beyond 7.5 mtr fixed to wall or burried in ground or drawn in pipe complete all as specified and directed
M/s Shiv Builder and Suppliers
M/s SUNIL ENTERPRISES
kirtiman traders
Nvimal Engineers and Contractor
MITTAL ENTERPRISES
VIPRABANDHU CONSTRUCTIONS
ENGINEER CORPORATION OF INDIA
PD GUPTA AND COMPANY
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .