Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 LAccepted-AOC | L1 | Accepted-AOC lowest bid | |
| 2 | L2₹35.3 L+₹2.3 L (6.88%)Rejected-Finance ROOM NO 13 HIMALAYA SHOPPING COMPLEX NELI SENGUPTA SARANI BABU PARA DARJEELING WEST BENGAL 734004 | DARJEELING | WEST BENGAL | 734004 | L2 | Rejected-Finance NOT LOWEST |
Tender Value
₹29.5 L
EMD Value
₹59,000
Closing Date
3 Mar 2020, 6:00 pmClosed
CWE RANCHI
HQ CWE RANCHI MES DIPATOLI CANTT PO RMCH RANCHI-834009
REPAIR / MAINT OF 33 KV HT SWITCH YARD AND 11 KV HT DISTRIBUTION SYSTEM AND ALLIED WORKS UNDER GE DANAPUR
2019_MES_289623_2
80599/1251/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Danapur
Class D Category B(iii)
7 documents required · 7 mandatory
₹500
Yes
GE DANAPUR
₹59,000
Yes
29 Jun 2020
8 Feb 2020
9 Mar 2020
8 Feb 2020
3 Mar 2020
18 Feb 2020
Amount
Excavation, in trenches n.exc 1.5 m wide & n.exc 1.5 m in depth for laying cable/pipes and getting out in any type complete all as specified and as directed.
Excavation, in trenches n.exc 1.5 m wide and exc 1.5m but n.exc 3 m in depth for laying cable/pipes etc and getting out in any type complete all as specified and as directed.
Removing excavated materials to a distance n exc 50 m and depositing, where directed at a level n exc 1.5m above the starting point complete all as specified and as directed.
Returning, filling in trenches including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick, complete all as specified and as directed.
M & L for sand cushioning to under ground cables ( 8 cm deep before laying of cable and 15 cm deep over the cable ) & punning gently including spreading and levelling complete all as specified and directed . Note :- Punned thickness shall only be considered for payment.
M&L laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified.
Supplying, straining and stretching of Over head aluminium conductor steel reinforced (ACSR) of any size on HT/LT poles including binding and jointing the conductor with and including 14 SWG binding wire and coloured sleeved jumpers with jumper connections with PG clamps complete all as specified.
Supplying, straining and stretching of Over head GI wire 4mm dia size on HT/LT poles including binding and jointing with conductor with and including 14 SWG binding wire and coloured sleeved jumpers with jumper connections with PG clamps complete all as specified.
Dismantling unserviceable ACSR conductor and GI wire, service feeder or distribution span complete all as specified and as directed.
Supply and fixing GI stay wire of 7/4 SWG upto required length including taking out and unserviceable one complete all as specified and directed.
Supply and fixing mild steel galvanised stay assembly set complete comprising of 14mm dia, 400mm long stay bow, 2150mm long stay rod 20mm dia, 300mm x 300mm x 6mm stay plate, thimble, loop insulator large size all as shown in electrical plate No.1 of MES Schedule part-I 2009 complete including dismantling and taking out old damaged stay assembly complete all as apecified and directed. Note :- PCC , earth work and Insulators etc shall be measured and paid separately.
Supplying, transporting and erecting in position steel tubular swaged poles 410-SP-55 type, 11.00 M long complete with mild steel base plate, CI finial taper , bolts, nuts and washers etc. including necessary excavation and earth work , PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting steel tubular poles exposed surafces with Aluminium paint two coats over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps with synthetic enamel paint and 2 bands with Black bituminous paint ) from plinth block and numbering of poles , painting embedded portion of poles with one coat of bituminous paint including disconnecting and taking out old damaged PCC pole complete all as specified and directed.
Supplying, transporting and erecting in position pre-stressed concrete pole 11 meters long 152 mm x 152 mm at top and 152 mm x 260 mm at bottom of class 9 complete, including disconnecting and taking out old damaged PCC pole complete all as specified and directed. Note - Earth work and PCC shall be measured and paid separately under respective items of this schedule.
M & L, PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation, filling & mass concrete complete all as specified and as directed.
M & L, PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation, filling & mass concrete complete all as specified and as directed.
M & L for Air break switch gang opreated 11000 V Triple pole, mechanically operated with 25 mm rod mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 400 amps complete including taking down carefully Gang operated air break switch complete all as specified and as directed.
Supplying, fixing, installing and commissioning and testing of 11 kV rated volatge, and 12 kV (max) system Voltage, 50 Hz frequency, 400 Amps continuous current rating, single phase Drop out fuse, outdoor type, each pole consisting GI steel base, 2 Nos HT insulators ,vertically mounting type, complete ,providing two coats of Aluminium paint over one coat of primer on all steel surfaces complete including taking down old unserviceable one all as specified and directed
Supply and fix gang operated air break switches, triple pole, manually operated, mounted on insulators and steel frame, with operating mechanism worked from ground level horizontal type /Vertical type in double stack type for rating upto 400 Amps, 33000 volts complete with GI operating pipe of heavy duty including taking down unserviceable one complete all as specified and as directed.
Taking down and repairing/overhauling of air break gang operated switch with DO fuse unit 11 KV/ 33 KV rating 200 Amp/400 Amp capacity triple pole mechanically operated mounted on insulators and steel frame installed vertically / horizontally , replacement of broken/worn-out components, oiling and greasing of mechanical moving parts, smoothing and polishing of electric contacts with providing conducting jelly of contacts refixed the same after repair including proper allienment complete all as specified and as directed. (Note:- Worn out component/ insulators / ASCR shall be measured and paid separately under respective items of this schedule.)
Supply only Female contact or fixed contact heavy duty and high conductive metal complete capacity 200A/400 Amp, 11 KV rated complete all as directed. Make - BHEL / Jaipuria/ Rashtriya/ MEI
Supply only Male contact or Moving contact heavy duty and high conductive metal complete capacity 200A/400Amp 11 KV rated complete all as directed. Make :- Rastriya/Jaipuria. Make - BHEL / Jaipuria/ Rashtriya/ MEI.
Supply only Tinned copper flexible jumper of capacity 200A/400A suitable for 11KV rated GOD complete all as directed.. Make - BHEL / Jaipuria/ Rashtriya/ MEI
Supply only Fixed top contact & Fixed bottom contact 11 KV 400 Amp for DO fuse unit complete all as directed. Make - BHEL / Jaipuria/ Rashtriya/ MEI
Supply only Fiber glass tube with metalic fittings both ends suitable for DO fuse 11KV rated complete all as directed. Make - BHEL / Jaipuria/ Rashtriya/ MEI.
Supply only mild steel jumper carrier suitable for 11 KV GOD as per sample complete all as directed..
Supply only back connector plate suitable for 11 KV GOD as per sample complete all as directed.
Supply only post insulator suitable for 11 KV GOD as per sample complete all as directed.
Supply only Female contact or fixed contact heavy duty and high conductive metal complete capacity 400 Amp suitbale for 33 KV rated horizontal GOD complete all as directed.. Make - BHEL / Jaipuria/ Rashtriya/ MEI
Supply only Male contact or Moving contact heavy duty and high conductive metal complete capacity 400 Amp suitbale for 33 KV rated horizontal GOD complete all as directed.. Make - BHEL / Jaipuria/ Rashtriya/ MEI.
Supply only post insulator suitable for 33 KV GOD as per sample complete all as directed.
Supply only Tinned copper flexible jumper of capacity 200A/400A suitable for 33 KV rated complete all as directed.
Supply only Fixed top contact & Fixed bottom contact 33 KV 400 Amp for DO fuse unit complete all as directed.. Make Rastriya/Jaipuria
Supply only Fiber glass tube with metalic fittings both ends suitable for DO fuse 33 KV rated complete all as directed. Make Rastriya/Jaipuria
Supply only mild steel jumper carrier as per sample complete all as directed.. Make Rastriya/Jaipuria
Supply only back connector plate as per sample complete all as directed.
Supply & fix lightening arrestor linear resistance type distribution class 9 KV RMS suitable for 11 KV system pole mounting type conforming to IS - 3070 Part-I including taking down existing unserviceable one complete all as specified and as directed.
M & L for Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of synthetic enamel paint over a coat of red oxide primer, complete all as directed including dismantling and taking out damage/rusted cross arms, bracings, supports, clamps and back plates from existing poles / dismantled poles / pole structures complete all as directed by EIC.
Supply and fixing Danger notice plate of 1.6mm thick mild steel sheet vitreous enameled white with letter figures and conventional skull and bones in signal red colour and fix with MS clamp for HT size 25 X 20 Cm and taking out of us one complete all as specified and directed.
M& L Pin type, porcelain, vitreous, white, brown or green insulator, 150 mm height, 150 mm dia for 11000 volts grade including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut andand taking out of unsv one complete all as specified. Make -PACTIL / MADRAS PORCELAIN / NGEF / JAIPURIA / BHEL .
M& L for Disc type insulator, porcelain, vitreous, white, brown or green insulator ( Single disc assembly ) of size 145 mm height, 255 mm dia ball socket type for working pressure 11 kv volts grade including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut including taking out of old unserviceable one complete all as specified. Make -PACTIL / MADRAS PORCELAIN / NGEF / JAIPURIA / BHEL .
M& L loop type, porcelain, vitreous, white, brown or green insulator large type 140 mm , clearence of hole 25.5 mm for 11000 volts grade including out of old unserviceable one complete all as specified. Make -PACTIL / MADRAS PORCELAIN / NGEF / JAIPURIA / BHEL .
M & L for restraining of HT /LT over head line single ACSR conductor comprising of any size of conductor aluminium/copper/GI after opening binding wire from insulators and replace binding wire and achieved permissible sag limit of over head line conductor complete all as directed and specified.
Repair / Servicing / maintenance of transformer 11 / .433 KV indoor / outdoor type , plinth / pole mounted type including the following work services :- (a) Disconnecting transformer from electric system and providing electric power to user from alternative arrangement including taking out from existing position . (b) Decanning of transformer oil , opening top cover , disconnecting of all internal connections , lifting and taking out of core assemble , LT / HT bushes, Tap changer etc ,cleaning and inspection of core and winding , segrigation of serviceable and unserviceable items , removing of sludge and cleaning tank and cooling pipes / fins /tanks with pressure water and drying the tank complete. (c) Replacinig unserviceable LT / HT bushing by replacing rubber / cork oil seals and damage terminal rod & replacement of Transformer cover gasket of rubber cork sheet. (d). Re installation of transformer including reassembling of core / winding assembly complete including replacement of unsv parts , repair the defective parts and tighting of all loose / sparks wire / nut bolts etc and refixing the to the existing position , connecting with HT/LT cables and earthing strip and testing complete including necessary Transportation ( If required ) to the work shop and back and including Dehyderation and refilling of existing or new transformer oil of required quantity complete all as directed. NOTE :- (i) Dehydration of oil and new Transformer oil shall be measured seperately. (ii) HT & LT Busing , Tap Changer shall be measured & Paid separataly. (iii) In case HV / LV Winding found damages then Contactor shall be made serviceable with new winding and the same will be measured and paid seperately. (iv) The rate of cork sheet & Packing Material of transformer of capacity 100 to 160 KVA shall deemed to be included in the quoted rate.
Description all as per item No 43 above but capacity 200 to 300 KVA .
Description all as per item No 43 above but capacity 400 to 500 KVA .
Supply only HT bushing porcelain with copper stud, nuts, bolts, washers, gasket, oil seal suitable for Indoor typeTransformer of capacity 100 to 160 KVA complete all as specified and directed.
Description all as per item No 46 above but capacity 200 to 300 KVA .
Description all as per item No 46 above but capacity 400 to 500 KVA .
Supply only HT bushing porcelain with copper stud, nuts, bolts, washers, gasket, oil seal suitable for outdoor type transformer of capacity 100 to 160 KVA complete all as specified and directed.
Description all as per item No 49 above but capacity 200 to 300 KVA .
Description all as per item No 49 above but capacity 400 to 500 KVA .
Supply only LT bushing porcelain with copper stud, nuts, bolts, washers, gasket, oil seal suitable outdoor / Indoor typeTransformer of capacity 100 to 160 KVA complete all as specified and directed.
Description all as per item No 52 above but capacity 200 to 300 KVA .
Description all as per item No 52 above but capacity 400 to 500 KVA .
Supply only Off load Tap changer switch of existing model / type of Transformer of capacity 100 to 160 KVA complete all as specified and directed.
Supply only Off load Tap changer switch of existing model / type of Transformer of capacity 200 to 300 KVA complete all as specified and directed.
Supply only Off load changer switch of existing model / type of Transformer of capacity 400 to 500 KVA complete all as specified and directed.
M&L for Dehydration of transformers oil minimum three cycles to achieve dielectric strength up to 50 KV in 2.5 mm gap electrode including toping up of Transformer oil if required at site . Note: (i) Dehydration of transformer oil shall be carried out at site and contractor shall be taken the testing result before and after dehydration of oil and shown to the EIC at site and maintain necessary documents for record . (ii) Dehydration Machine with all T&P & Transformer oil testing machine for dehydration of Transformer oil and necessary transportation for the machines shall be arranged by contractor . (iii) Oil required for topping up the transformer will be measured & paid separatly.
Supply and top up of transformer oil EHV as per IS 335 of 1993 Part II with dielectric strength up to 50 KV in 2.5 mm gap electrode complete including necessary transportation complete all as specified and as directed.
Removing of existing damage insulating material from LV Winding , Cleaning the winding and reinsulating the LV Winding with approved grade and make of insulating paper and heating the coil in the heat chamber to obtained desired result of insulating resistence and re-installation complete all as specified and as directed.
M & L for rewinding of transformer HV coil with super enamelled / paper coated copper wire of existing gauge including all associated insulating material such as separator etc complete varnishing, heating including opening of top cover, decanting transformer oil, storing the same in suitable container, disconnection live part, dismantling of bushing, lifting of core Assembly, checking the windings, cleaning of cooling tube, conservator and all internal connection after all necessary repair work and rewinding, reassemble the complete transformer and refilling after necessary filtration including all internal connection etc of any type / capacity transformer. Note : Filtration of oil, insulator, spindle and gasket etc shall be measured and paid separately.
M & L for rewinding of transformer LV coil with super enamelled / paper coated copper wire of existing gauge including all associated insulating material such as separator etc complete varnishing, heating including dismantling of top cover, decanting transformer oil, storing the same in suitable container,disconnection live part, dismantling of bushing, lifting of core Assey, checking the windings, cleaning of cooling tube, conservator and all internal connection after all necessary repair work and rewinding, assemble the complete transformer and refilling after necessary filtration including all internal connection etc of any type / capacity transformer. Note : Filtration of oil, insulator, spindle and gasket etc shall be measured and paid separately.
Supply and replacement of silica gel cristal complete all as specified and as directed.
Supply and fixing in repalcement of heavy duty breather assembly with Silica jel cristal complete for Transformer upto 300 KVA complete all as specified and as directed.
S & F in replacement Winding tempreture gauge for Transformer 0 - 150 C complete all as specified and as directed.
M & L for Painting of steel pole with cross arms, clamp of any length and shape for HT overhead line with single coat of aluminium paint including preparation of the existing surface including marking pole numbers in a 20 cm dia RED circle with yellow colour numbering with synthetic enamelled paint and strip marking of THREE RED AND THREE YELLOW alternatively of width 15 cm by fluorescent paint, from bottom of pole to 90 CM height and providng three nos of Red ,Yellow & Blue of reflecting strip of 25 mm width adhesive PVC tape around the pole at suitable height complete all as specified and directed.
Description same all as per item No 66 but HT 2-Pole structure complete all as specified and directed.
M & L for cleaning , scraping out old rubbed paint / rust & Painting of transformer complete of capacity up to 63 to 250 KVA 11/.433 KV outdoor / Indoor type with one coat of spray painting with synthetic enamelled gray paint (first grade) by spray painting machine on transformer & writting SM NO on surface of transformer complete all as specified and directed.
Description all as per item No 68 above but capacity 300 to 500 KVA 11/0.433 V complete all as specified and directed.
M & L for restraining of HT /LT over head line single ACSR conductor comprising of any size of conductor aluminium/copper/GI after opening binding wire from insulators and replace binding wire and achieved permissible sag limit of over head line conductor complete all as directed and specified.
Earthing complete with galvanized iron earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge earth plate not less than 1.5m below GL. connected to galvanized earth lead wire 4 mm dia to earth plate electrode by means of nuts, bolts and washers made of galvanized iron or steel earth wire protected by 15 mm bore light grade GI pipe and connected for body earthing of feeder pillar box all as specified with & including PCC (1:3:6) type C1 pit and precast RCC (1:2:4) type B1, cover slab of size 300x300x50mm, with handle GI funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal and salt in alternate layer including necessary earth work on any type of soil and removal etc, complete all as specified and shown in electrical plate No 3 of SSR Part I including taking out old unserviceable earthing complete all as specified and as directed.
Earthing complete with galvanized iron earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge earth plate not less than 1.5m below GL using galvanised iron strip 32×6mm as earthing lead to earth plate electrode by means of nuts, bolts and washers made of galvanized iron or steel earth wire protected by 15 mm bore light grade GI pipe and connected for body earthing of feeder pillar box all as specified with & including PCC (1:3:6) type C1 pit and precast RCC (1:2:4) type B1, cover slab of size 300x300x50mm, with handle GI funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal and salt in alternate layer including necessary earth work on any type of soil and removal etc, complete all as specified and shown in electrical plate No 3 of SSR Part I including taking out old unserviceable earthing complete all as specified and as directed.
M & L for earth continuity conductor or main earthing lead of 4 mm dia galvanized iron or steel wire, buried in ground or fixed to wall in repair complete all as specified and directed.
M & L for Earth continuity conductor or main earthing lead of 32 x 6 mm galvanized iron strip, buried in ground or fixed to wall in repair complete all as specified and directed.
Labour required for trimming / cutting of tree branches/long bushes / bambooes (of any girth), touching / obstructing the over head LT/HT lines at places so as to keep minimum 1.50M mtr clearance all around the lines and disposal thereof to not exceeding 100 mtr distance after taking proper electric shut down from concerned staff complete all as specified and directed.( Note :- Grith of tree branches shall be measured only above 50mm dia ).
M&L Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm including testing complete all as specified and as directed. Make - Denson /Raychem / 3M
M&L Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm including testing complete all as specified and as directed. Make - Denson /Raychem / 3M
M&L Cable jointing kit for 33 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm including testing complete all as specified and as directed. Make - Denson /Raychem / 3M
M&L Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armourend aluminium conductor cable of size 95 sqmm including testing complete all as specified and as directed. Make - Denson /Raychem / 3M
M&L Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armourend aluminium conductor cable of size 120 sqmm including testing complete all as specified and as directed. Make - Denson /Raychem / 3M
M&L cable jointing kit for 11 KV grade cable for straight through outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Alluminium conductor cable of size 95 to 120 sqmm including testing complete all as specified and as directed. Make - Denson /Raychem / 3M
Supplying, laying, jointing, testing and commissioning HT XLPE insulated, screened , PVC bended galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor screening with extruded semi conditioning layers insulation screening with copper tape cover laid upto with PVC (ST-2) extruded, inner sheathing galvanized steel strip armoured PVC (ST-2) outer sheathed cable confirming to IS-7098 (Pt-II) 11/6.35 KV grade suitable for earthed system cross sectional area 95 sqmm 3 core H.T.U.G cable laid in trenches/through GI pipe/fixed along with pole including taking out of old unserviceable cable complete all as specified & as directed. Make: Havells/Plaza/Polycab/KEI.
Supplying, laying, jointing, testing and commissioning HT XLPE insulated, screened , PVC bended galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor screening with extruded semi conditioning layers insulation screening with copper tape cover laid upto with PVC (ST-2) extruded, inner sheathing galvanized steel strip armoured PVC (ST-2) outer sheathed cable confirming to IS-7098 (Pt-II) 33 KV grade suitable for earthed system cross sectional area 120 sqmm 3 core H.T.U.G cable laid in trenches/through GI pipe/fixed along with pole including taking out of old unserviceable cable complete all as specified & as directed. Make: Havells/Plaza/Polycab/KEI.
Supply & fix 11 KV (E) Grade Aerial Bunched Cable of size 3 x 95 + 1 x 70 Sqmm with 3 (three) power cores (stranded, compacted circular aluminium conductor screened with black extruded semi-conducting compound, natural coloured XLPE insulated core screened with black extruded semi-conducting compound and one layer of copper tape and coved with black extruded PVC (core identification by colour tape marking red, yellow & blue with colour tape placed longitudinally under the copper tape) and one bare messenger wire shall be stranded non - compacted circular Aluminium alloy conductor complete all as specified and directed by Engr-in-Charge.
Supply and fixing of GI tubing, light grade, 100 mm bore with all fitting lais in trenches / pole / wall for protection of cables in repairs complete.
Material and labour HT Cable rout indicator made out of PCC Post of 1:2:4 of size not less than 20 x 15 cm and one meter height with making embossing the following letters of size 100 mm in the PCC Post " HT CABLE " including necessary excavation and PCC 1:2:4 (30 X 30 x 30 CM ) for embeding in the ground complete all as specified and directed.
M&L for Synthetic insulating rubber mat suitable for 33 KV HT installation of size 2 m x 1m x 25 mm complete all as specified and directed by EIC.
Supply and fixing digital over current protection relay ( 3 OC + 1 EF & INST. Protection ) with micro processor based complete all as specified and directed . Make - CG , Cat No - CGI 14 N/C OR equivalent Make of L & T / Siemence / C & S as approved by the GE . NOTE : - Relay should be suitable as per existing type / Make for 11 / 33 KV VCB'S / Control Panel .
Repair / Servicing / maintenance of Current/ Potential transformer (CT and PT) 33 / 11 KV outdoor type, steel structure mounted type of any capacity including disconnecting of CT/PT from electric system including taking out from existing position, decanning of transformer oil, opening of cover complete checking of all connection and including replacing of old transformer oil and all gaskets, complete new painting as per existing and providing greasing/lubrication to other jointing/rusting components, reconditioning electric connections, replacinig unserviceable HT bushing, rubber / cork oil seals and damage spindle as required complete all as specified and as ditected.
Servicing / Calibration to 33 KV HT VCB panel and PCOB for Vaccum interruptor complete including the following : switching off electric supply, Checking of mechanical system for proper functioning, replacing closing buffer, triping buffer (VMX type), V I connection gap check, motor coil resistance check, closing coil resistance check, spring charging cut off switch check, aux switch check, NO-NC states check, trip coil resistance check, testing details, timing test, oil value test, breaker timing test, connector resistance test, IR value test, HV test, mechanical and electrical mechanism check, counter reading check, shock observer check, pre close/ post close circuit check, test and service position limit switch check, breaker drive screw operation check, trip coil assemble operation check, mechanical latch . Cleaning & servicing the fixed/ moving contact & blowing out dust and applying the proper lubrication/ greasing and reassembling the VCB including connection to HT panel complete to be replaced where reqd all as directed by EIC. Note:- (1) Maitenance of all HT VCB will be carried out as per maintenance schedule (2) Testing of above job to be carried out by engineers of authorised dealer/service centre. (3) Replacing new items shall be measured and paid separately as supply only
Servicing / Calibration to 11KV HT VCB/RMU panel complete including the following (a) Taking out 11KV HT VCB of 630 Amps rating trolley from HT Panel after switching off electric supply.Checking of mechanical system for proper functioning of upward/downward movement of HT VCB trolley including replacing closing buffer, triping buffer (VMX type), VI connection gap check, motor coil resistance check, closing coil resistance check, spring charging cut off switch check, aux switch check, NO-NC states check, trip coil resistance check, testing details, timing test, oil value test, breaker timing test, connector resistance test, IR value test, HV test, mechanical and electrical mechanism check, counter reading check, shock observer check, pre close/ post close circuit check, test and service position limit switch check, breaker drive screw operation check, trip coil assemble operation check, mechanical latch . Cleaning & servicing the fixed/ moving contact & blowing out dust and applying the proper lubrication/ greasing and reassembling the VCB including connection to HT panel complete to be replaced where reqd all as directed by EIC. Note:- (1) Maitenance of all HT VCB will be carried out as per maintenance schedule (2) Testing of above job to be carried out by engineers of authorised dealer/service centre. (3) Replacing new items shall be measured and paid separately as supply only.
Supply only shunt closing/tripping coil operated on 110 /30 volt system suitable for working of relay of HT SF6 / VCB complete all as specified and directed.
Supply and fixing in repairs spring charging motor suitable for fixing with 33/11 KV indoor type VCB panels complete all as specified and directed. Make - MICO/ABB/C&S/L&T.
S&F digital earth fault and over current relay in respective make, in existing 11/33 KV panel complete all as specified and directed. (Make Crompton/ L&T nX series MC61A cat MC61ANX2200)
S&F in repairs vaccum interputer suitable for 11 KV VCB trolly complete all as specified and directed.
S&F in repairs moving contacts of VCB made of copper and suitable for 11 KV VCB Trolley compete all as specified and directed.
Supply only meter devices 3 phase digital type Amp meter 0- 120 Amp class 0.5 of size 96 mmx96 mm to match the ratio of existing CTs. Make: Conzerve Cat No DM 3258 or equivalent model of IMP/AE Bombay/Meco as approved by the GE.
Supply only meter devices 3 phase digital type Volt Meter 0- 12 KV class 0.5 of size 96mm x 96 mm to match the ratio of existing CTs. Make conzerve Cat No DM 3256 or equivalent model of IMP/AE Bombay/Meco as approved by the GE
Supply, installation and testing of current transformer 33 KV single phase outdoor oil cooled CT ratio 200/5-5 Amps class 1.0-5 P 10 burden 15 VA, insulation level 70KV/170KV as per IS-2705 complete all as specified and as directed. Make: Crompton Greaves/ ABB/Kappa.
Supply, fixing, jointing and testing aerial bunch cable jointing kit for 11 KV grade cable, for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for XLPE insulated armoured aluminium conductor cable of size 95 sqmm (3 X1C cable) complete all as specified.
S&F lightening arrestor linear resistance type complete with all fitting,distribution class suitable for 33 KV system pole mounting type conforming to IS - 3070 Part-I including taking down existing unserviceable one complete all as specified and as directed.
S&F in repalcement of heavy duty breather assembly with Silica jel cristal complete suitable for transformer 1000 KVA with minimum 1.5 Kg silica gel complete all as specified and as directed. Make: Yogya Enterprises India, Model: DTO-4.
M & L for cleaning , scraping out old rubbed paint / rust & Painting of transformer complete of capacity 1000 KVA, 33/11 KV outdoor type with two coat of spray painting with synthetic enamelled gray paint (first grade) by sprey painting machine on transformer & Making SM NO on surface of transformer complete all as specified and directed.
S&F post insulator porcelain viterous brown suitable for 33 KV complete all as specified and as directed
S&F Pin type insulator, porcelain, vitreous, white, brown or green insulator, suitable for 33000 volts grade including taking out of unsv one complete all as specified and as directed. Make -PACTIL / MADRAS PORCELAIN / NGEF / JAIPURIA / BHEL .
M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate in coping to pole and like etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed.
Manish Ray and Co.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .