Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹25.8 LAccepted-AOC 10TH FLOOR TOWER A3 FLAT NO 1001 MI RUSTLE COURT GOMTI NAGAR EXTENSION GOMTI NAGAR LUCKNOW UP 226010 | LUCKNOW | LUCKNOW | UP | 226010 | L 1 | Accepted-AOC Being Lowest Bid and EAS accepted by IFA and TC | |
| 2 | L 2₹36.3 L+₹8.2 L (29.4%)Rejected-Finance 41 SAKOORPUR ROAD NEAR PRIMARY SCHOOL NEW JANKIPURAM NEELMATHA LUCKNOW CANTONMENT PO DILKUSHA LUCKNOW UP PIN 226002 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226002 | L 2 | Rejected-Finance Other Than lowest | |
| 3 | L 3₹38.7 L+₹10.6 L (37.9%)Rejected-Finance SA 15 144 S 1 CHANDAN HERITAGE HAVELIA CHAURAHA SARNATH VARANASI U P 221007 | VARANASI | VARANASI | UTTAR PRADESH | 221007 | L 3 | Rejected-Finance Other Than lowest | |
| 4 | L 4₹39.4 L+₹11.3 L (40.4%)Rejected-Finance GALI NO 5 6 H NO 6 275 JHARODA MAARA EXTN PART III BURARI NEW DELHI 110084 | NEW DELHI | CENTRAL DELHI | DELHI | 110084 | L 4 | Rejected-Finance Other Than lowest | |
| 5 | L 5₹39.6 L+₹11.6 L (41.3%)Rejected-Finance 44 NEAR DURGA MANDIR TRIPURI TOABA TRIPURI TOWN PATIALA 147004 PB | PATIALA | PUNJAB | 147004 | L 5 | Rejected-Finance Other Than lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
6 Jul 2024, 6:00 pmClosed
GE (EAST) LUCKNOW
GE EAST LUCKNOW PIN 226002
REPAIR REPLACEMENT OF INTERNAL WIRING FITTINGS AND FIXTURES AND CONNECTED WORKS OF OFFRS JCOS ORS MD ACCN AREA OF AGE EM YARD II UNDER GE EAST LUCKNOW
2024_MES_660084_1
GE/E/LKO/T-22 OF 2024-25
Open Tender
Civil Works
Item Rate
180 days
GE (EAST) LUCKNOW
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE (EAST) LUCKNOW
₹80,000
Yes
31 Aug 2024
15 Jun 2024
13 Jul 2024
15 Jun 2024
6 Jul 2024
29 Jun 2024
Amount
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete except fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing complete all as specified and directed.
Material and labour for one light / fan point controlled by one, one way switch 06 Amp wiring with 1.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sq mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60 mm thick with 3 mm thick Hylem laminated sheet top cover, steel screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified and directed.
All as per serial item No 02 here-in-before but one bell point controlled by one bell push, 06 Amp complete all as specified and directed.
All as per serial item No 02 here-in-before but one, two way light point controlled by two, two way switches, 06 Amp complete all as specified and directed.
All as per serial item No 02 here-in-before but one 3 pin, 06 Amp socket outlet point on independent board controlled by one, one way switch 06 Amp complete all as specified and directed.
All as per serial item No 02 here-in-before but one 3 pin, 06 Amp socket outlet point on same board controlled by one, one way switch 06 Amp complete all as specified and directed.
All as per Serial Item No 02 here-in-before but point wiring with 2.5 Sq mm single core FRLS cables and earth continuity wire of 1.5 Sq mm single core FRLS cable for one 3 pin 16 Amp socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
Material and labour for one light / fan point controlled by one, one way switch 06 Amp wiring with 1.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sq mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60 mm thick modular type ( including metal flush box) etc and making good to the disturbed surfaces to match the existing complete all as specified and directed.
Taking down OLD U/S Switch/socket/Ceiling rose/calling bell/bell push/lamp holder/Regulator any type and size complete all as specified and directed.
S&F Switch Modular 6A single pole, one way, 1 module complete all as specified and as directed
S&F Switch Modular 16A single pole, one way, 1 module complete all as specified and as directed
S&F Socket, 6A - 2/3 pin combined 2 module complete all as specified and as directed
S&F Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and as directed
S&F Modular White cover plate with frame,18 module complete all as specified and as directed
S&F White cover plate with frame,12 module complete all as specified and as directed
S&F Modular White cover plate with frame,8 module complete all as specified and as directed
S&F Modular White cover plate with frame,6 module complete all as specified and as directed
S&F Modular White cover plate with frame,4 module complete all as specified and as directed
S&F Modular White cover plate with frame,3 module complete all as specified and as directed
S&F Modular White cover plate with frame,2 module complete all as specified and as directed
S&F Calling bell , AC, 230 Volts, single phase complete all as specified and as directed
S&F bell push , AC, 230 Volts, 2 module complete all as specified and as directed
Supply and fixing fan step regulator, 120W 2 module Modular type complete all as specified and as directed
Supply and fixing switch piano flush type, 06 Amp, single pole, one way, 230 Volt complete all as specified & directed.
Supply and fixing switch piano flush type, 06 Amp, single pole, two way, 230 volt complete all as specified & directed.
Supply and fixing bell push, flush type, 06 Amp, 230 volt complete all as specified & directed.
Supply and fixing socket outlet 2 in 1, 5 pin, 06 Amp, flush type, 230 volt complete all as specified & directed.
Supply and fixing switch socket combination outlet 2 in 1, 3 pin, 06 Amp and 16 Amp flush type, universal, 230 volt, four hole complete all as specified & directed.
Supply and fixing electronic ceiling fan regulator piano type with rotary step, two module, humfree, AC, 240 volt, 100 Watt and duly ISI marked complete all as specified & directed.
Supply and fixing lamp holder, PVC / Polycarbonate type with back plate suitable for batten fitting complete all as specified & directed.
Supply and fixing replacement of decorative wall mounting type LED light fitting, 1 x 15 Watt, 230 Volt made up of Polycarbonate including shade, lamp holder, 9/10 Watts LED lamp B22 CDL etc and all accessories pre-wired including connecting up complete all as specified and directed.
Supply and fix in replacement of integrated LED bulk head fitting 10 Watt, 6500K with IP 65 protection comprises of high pressure die cast aluminium housing, polycarbonate cover, etc complete all as specified and directed.
Supply and fix in replacement LED tube light fittings 1200 mm, 20 W higher energy saving decorative ultra slim square profile LED lighting fixture with extruded polycabonate without powder coating enviromental friendly, energy efficient complete all as specified and directed.
Supply and fix in replacement LED tube light fittings 600 mm,10/12W higher energy saving decorative ultra slim square profile LED lighting fixture with extruded polycabonate enviromental friendly, energy efficient complete all as specified and directed.
Supply & fix in replacement LED wall/surface mounted down lighter, 6 to 12 W including electrical connection with copper flexible wire & all necessary fixing accessories complete all as specified.
Supply and fix in replacement ceiling rose, 6 Amp, 250 volt, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25 mm size complete all as specified & directed.
Supply & fix in replacement LED wall/surface mounted down lighter, 15 W including electrical connection with copper flexible wire & all necessary fixing accessories complete all as specified.complete all as specified & directed.
Supply and fixing in replacement sensor based integrated LED tube light LED tube light fittings 1200 mm, 20 W higher energy saving decorative ultra slim square profile LED lighting fixture with extruded polycabonate without powder coating enviromental friendly, energy efficientall as directed complete all as specified & directed.
Supply and fix in replacement of industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 240 volt of 20 Amp, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
Supply only LED bulb chargable type having backup time of 3 to 4 hours 18 Watts suitable for B22 white in colour complete all as specified & directed.
Supply and fixing in replacement LED bulb 9 Watts suitable for B 22 Warm white in colour complete all as specified & directed.
Supply in replacement LED bulb 9/10 Watts suitable for B 22 white in colour complete all as specified & directed.
S&F in replacement PVC casing n caping ISI marked of size 20mm complete all as specified & directed.
S&F in replacement PVC casing n caping ISI marked of size 25mm complete all as specified & directed.
S&F in replacement rigid non-metallic PVC conduit of size 20mm complete all as specified & directed.
S&F in replacement rigid non-metallic PVC conduit of size 25 mm complete all as specified & directed.
S&F in replacement Flexible conduit of size 20mm complete all as specified & directed.
S&F in replacement Flexible conduit of size 25 mm complete all as specified & directed.
S&F in replacement PVC gang box suitable for 6 Amp Socket and 6 amp switch.complete all as specified & directed.
S&F in replacement PVC gang box suitable for 16 Amp Socket and 16 amp switch.complete all as specified & directed.
S&F in replacement Aluminium cable 2.0 core armoured cable 6.0 sqmm armoured cable complete all as specified and directed.
S&F in replacement Aluminium cable 2.0 core armoured cable 10.0 sqmm armoured cable complete all as specified and directed.
S&F in replacement decorative ,wall mounted bed side LED light fittings 9 Watt , brushed nikel finish fixture with opal glass diffuser suitable with 9 watt LED bulb B 22 base energy saving complete all as specified and directed.
S&F the insulation tape 10 Mtr complete all as specified and directed
S&F the insulation tape 15 Mtr complete all as specified and directed
S&F the insulation tape 25 Mtr complete all as specified and directed
S&F in replacement of unserviceable wire of size 1.5 Sqmm single core with PVC insulated unsheathed FRLS multistranded copper conductor for working Voltage 1100 Volts for gate light connection complete all as specified and directed
S&F in replacement of unserviceable wire of size 2.5 Sqmm single core with PVC insulated unsheathed FRLS multistranded copper conductor for working Voltage 1100 Volts for gate light connection complete all as specified and directed
S&F in replacement of unserviceable wire of size 4.0 Sqmm single core with PVC insulated unsheathed FRLS multistranded copper conductor for working Voltage 1100 Volts for gate light connection complete all as specified and directed
S&F in replacement of unserviceable wire of size 2.5 Sqmm three core with PVC insulated unsheathed FRLS multistranded copper conductor for working Voltage 1100 Volts for gate light connection complete all as specified and directed
Supply and fixing PVC trunking 54x105 mm size for cable tray riser to DB and DB to sub DB for sub main wiring including making good to disturbed wall surfaces complete all as specified and directed. Make- Hager, Cat No-GBD501310 or equivalent as approved by GE. (Note Rate of Accessories such as elbow , bend tee , socket, junctions and flexible cover ,Coupling set/End cap/Internal corner/External corner/flat corner/T-Piece/3-D Internal corner is incl in the item rates and no extra payment will be done to the contractor.complete all as specified & directed.
S&F in replacement of in factory made Pantone 7541C shade powder coated distribution board SPN 4 way double door fabricated of CRCA sheet with metal door (IP-43 protection) bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one SP MCB as a incomer and 3 SP MCBs as outgoing complete all as specified and directed conforming to IS: 8623 along end box for above DB complete all as specified & directed.
Supply and fix in replacement of sheet metal enclosure distribution board triple pole and neutral (VTPN),double door, AC, 440 volt, 08 way with 200 Amp rated copper bus bar and metal door with IP 54 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed and comprising of the following:- (a) MCCB, 200 Amp, 04 pole, AC, 415 Volt of 16 KA breaking capacity complete - 01 No. Make:- Havells/L&T/ABB/Sechinder/Indo-Asian (b) MCB, SPN, AC, 240 volt of 40 Amp, "C" curve, 10 KA breaking capacity - 08 Nos.
Supply and fix in replacement of sheet metal enclosure distribution board triple pole and neutral (VTPN),double door, AC, 440 volt, 04 way with 200 Amp rated copper bus bar and metal door with IP 54 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed and comprising of the following:- (a) MCCB, 125 Amp, 04 pole, AC, 415 Volt of 16 KA breaking capacity complete - 01 No. Make:- Havells/L&T/ABB/Sechinder/Indo-Asian (b) MCB, SPN, AC, 240 volt of 40 Amp, "C" curve, 10 KA breaking capacity - 08 Nos.
M&L in factory made Pantone 7541C shade powder coated distribution board SP & N 12 way double door fabricated of CRCA sheet with metal door (IP-43 protection) bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as a incomer and 10 SP MCBs as outgoing complete all as specified and directed conforming to IS: 8623 along end box for above DB complete all as specified & directed.
M&L in factory made Pantone 7541C shade powder coated distribution board SP & N 8 way double door fabricated of CRCA sheet with metal door (IP-43 protection) bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as a incomer and 6 SP MCBs as outgoing complete all as specified and directed conforming to IS: 8623 along end box for above DB complete all as specified & directed.
M&L for replacement TPN MCB 40 Amps, 240 v, 50 Hz AC Made from moulded self extinguishing thermostat plastic and suitable for 'C' curve, 10KA breaking capacity and terminal box suitable upto 35 sqmm cable complete conforming to IS 8828, IEC 60898 . complete all as specified & directed.
M&L for replacement TPN MCB 63 Amps, 240 v, 50 Hz AC Made from moulded self extinguishing thermostat plastic and suitable for 'C' curve, 10KA breaking capacity complete conforming to IS 8828, IEC 60898 complete all as specified & directed.
M&L in replacement of SP MCB 6 TO 32 Amps, 240 v, 50 Hz AC Made from moulded self extinguishing thermostat plastic and suitable for 'C' curve, 10KA breaking capacity and terminal box suitable upto 35 sqmm cable complete conforming to IS 8828, IEC 60898 complete all as specified & directed.
M&L in replacement of MCB Single Pole & Neutral MCB 32 Amps, 240 v, 50 Hz AC Made from moulded self extinguishing thermostat plastic and suitable for 'C' curve, 10KA breaking capacity and terminal box suitable upto 35 sqmm cable complete conforming to IS 8828, IEC 60898 .complete all as specified & directed.
M&L in replacement of MCB Single Pole & Neutral MCB 40 Amps, 240 v, 50 Hz AC Made from moulded self extinguishing thermostat plastic and suitable for 'C' curve, 10KA breaking capacity and terminal box suitable upto 35 sqmm cable complete conforming to IS 8828, IEC 60898 .complete all as specified & directed.
M&L in replacement of MCB Single Pole & Neutral MCB 63 Amps, 240 v, 50 Hz AC Made from moulded self extinguishing thermostat plastic and suitable for 'C' curve, 10KA breaking capacity and terminal box suitable upto 35 sqmm cable complete conforming to IS 8828, IEC 60898 .complete all as specified & directed.
Supply and fixing in replacement of MCCB current rating 125 Amps with thermal magnetic release, 3 pole, 415 volts AC 25 KA Ics = 50% Icu as per IEC 60947-2ruputuring capacity complete all as specified & directed.
Taking down old U/S Bldg security/street lights/Gate lights/Bollard light/flood lights of any type any size retreived from existing site complete all as specified & directed.
Supply and fix LED gate light of 40/45W LED Postop luminaire with aluminium pressure die-cast mounting spigot & polyester powder coating in addition to a specific weathering resistance treatment, color RAL7011. Non-yellowing transparent Polycarbonate UV-protected round symmetrical diffuser with circular radial pattern for glare-free and even light distribution. High Efficiency long life LED module with efficacy of >100Lm/W, CCT 4000K, and CRI >70. Powered by built-in electronic driver with THD <10%, 4kV inbuilt surge protection, high cut-off at 325V & auto-restart, including 8hrs. protection from 440V (P2P). Incl GI Pipe 40mm dia 0.45mtr long fixed in gate pole with PCC 1:2:4 of 0.20 mtr height and size of existing gate pole. Fixture lumen efficacy >4500 Lm, IP66 (no glue), IK05, PF>0.95, Operating voltage range: 140- 277V, complete all as specified & directed. by engineer in charge.
Supply and fixing LED building security light of 25W Led Street Light made up of pressure die cast aluminium housing with Polycarbonate cover and unique road optics for better uniformity. The luminaire shall be with higher ingress protection IP66 and impact resistance of IK07. Operating voltage range: 140-270V/50Hz, Lumen efficacy of LED >120Lm/W, CRI≥70, CCT-5700K, & SDCM<5. Powered by built-in potted LED driver gives constant light over wide voltage range. Shall have High Voltage cut-off@325V & safety from 440V (P2P) for 8 hours. Surge protection 4 kV, Power factor ≥0.95, THD ≤10 complete including 25x3 mm flat iron with bracket of GI pipe light grade 25 mm dia and length not less than 1.2 mtr end of GI pipe suitable for street light fitting complete all as specified and directed by the Engr-in-Charge.
Supply and fixing LED building security light of 35/36W Led Street Light made up of pressure die cast aluminium housing with Polycarbonate cover and unique road optics for better uniformity. The luminaire shall be with higher ingress protection IP66 and impact resistance of IK07. Operating voltage range: 140-270V/50Hz, Lumen efficacy of LED >120Lm/W, CRI≥70, CCT-5700K, & SDCM<5. Powered by built-in potted LED driver gives constant light over wide voltage range. Shall have High Voltage cut-off@325V & safety from 440V (P2P) for 8 hours. Surge protection 4 kV, Power factor ≥0.95, THD ≤10 complete including 25x3 mm flat iron with bracket of GI pipe light grade 25 mm dia and length not less than 1.2 mtr end of GI pipe suitable for street light fitting complete all as specified and directed by the Engr-in-Charge.
Supply and fixing LED building security light of 40W Led Street Light made up of pressure die cast aluminium housing with Polycarbonate cover and unique road optics for better uniformity. The luminaire shall be with higher ingress protection IP66 and impact resistance of IK07. Operating voltage range: 140-270V/50Hz, Lumen efficacy of LED >120Lm/W, CRI≥70, CCT-5700K, & SDCM<5. Powered by built-in potted LED driver gives constant light over wide voltage range. Shall have High Voltage cut-off@325V & safety from 440V (P2P) for 8 hours. Surge protection 4 kV, Power factor ≥0.95, THD ≤10 complete including 25x3 mm flat iron with bracket of GI pipe light grade 25 mm dia and length not less than 1.2 mtr end of GI pipe suitable for street light fitting complete all as specified and directed by the Engr-in-Charge.
S & F in replacement street light GI bracket of 1.2 mtr long made out of 40mm dia light grade GI pipe bend to shape of 120 degree end welded at required including 02 Nos MS clamp of flat iron 40 x 6mm with nuts bolts & washers for fixing on wall complete necessary fixing arrangements on pole incl taking out old U/S bracket as directed.
Supply, install, test and commissioning in replacement factory made THERMOPLASTIC/HDPE CABLE JUNCTION BOXES IP 66/67 “weather proof”, with terminals for outdoor installation (with knockouts for cable entry) of min size 205 x 255 x 112 mm depth with cable entry size of 10-25 sqmm with terminal incl Aluminium bus bar of 63amp----04 Nos and MCB SP 6amp-----01 No. complete fixed on wall complete all as specified & directed.
Material and labour for sub main wiring with 10 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 10 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
Material and labour for sub main wiring with 06 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 06 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
Material and labour for sub main wiring with 04 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
Material and labour for earthing complete with galvanised mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level steel earth plate connected with GI wire 04 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40 mm x 40 mm x 3 mm frame for pit cover including testing on completion complete all as specified and directed.
M&L for writting name in LED lighting system with enclosure size 3 mtr x 0.8 mtr CGI Sheet min 2.0 mm thickness (AGE E/M (EAST) YARD-II LUCKNOW) with minimum size 300 x 50 mm in PVC material IP-66 of complete as per sample complete all as specified & directed.
M/S BHAGIRATHI ENTERPRISES
M/s A.K Construction
QUALITY CONSTRUCTIONS CO
Mohinder Pal and Sons
R K CONTRACTOR AND SUPPLIERS
Mohit Enterprises
ANAND FURNITURE
Supreme Builders
M/S SGS ENETERPRISES
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .