Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.5 LAccepted-AOC 2549 NATHA SINGH STREET MEHNA MOHALLA BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L1 | Accepted-AOC Being lowest and resonable | |
| 2 | L2₹12.9 L+₹44,696 (3.58%)Rejected-Finance | L2 | Rejected-Finance Being not lowest |
Tender Value
₹16 L
EMD Value
₹32,000
Closing Date
27 Dec 2019, 6:00 pmClosed
GE (AF) Halwara
GE (AF) Halwara
CA No GE/HAL-44/2019-20
2019_MES_300820_1
CA No.GE/HAL-44/2019-20
Open Tender
Civil Works
Item Wise
273 days
GE (AF) Halwara
Refer NIT
10 documents required · 10 mandatory
₹500
Yes
GE (AF) Halwara
₹32,000
Yes
1 Jan 2020
25 Nov 2019
28 Dec 2019
26 Nov 2019
27 Dec 2019
20 Dec 2019
30 Nov 2019 - 7 Dec 2019
Amount
Complete arrangement, transporting, accessorise for carry out Chemical Analysis test incl bacteriological examination of drinking. The sample of drining water for testing shall be taken from following locations for further submission to the lab. The cost of sampling, transporation and testing charges shall be born by the contractor (a) Pump No.1 (b) Pump No.3 (c) MAP Pump. (d) Ó'Point (e) Alternate site. Note :- Address of raputed laboratories are given below (i) The Shirram institute for industrials reasearch 19, University road Delhi-7 (ii) Dr Ghuman and Gupta Geotech Consuitents Sec-17A Chandigarh or F-81 phase Vii Industrial Focval point Mohali,(PB). (iii) AFMC- Pune (Deptt of PSM, Post Graduate wing) (Iv) Water testing Reasearch Labor Hisar Haryana. (v) Delhi Test House A-62/3 GT Road Karnal Road Azadpur Delhi-33.
Excavation in trenches not exc.1.5 mtr wide and not exc.1.5 m in depth for laying of pipes as in soft soil and getting out, complete all as specified and directed.
Returning, filling, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in any type of soil, complete all as specified and directed.
Removal of excavated material to a distance not exc.50 m and depositing where directed at a level not exceeding 1.5 mtr above starting point.
Taking up or down steel tubing of 20mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to credit complete with all fittings etc complete all as specified and directed.
All as per Srl Item No 5.00 above but 25m bore.
All as per Srl Item No 5.00 above but 40m bore.
All as per Srl Item No 5.00 above but 50m bore.
S&F GI water tubing 20mm bore 'medium grade', galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and as directed by Engr-in-Charge. Note :- Excavation & earth work shall be measured and paid separately one time only if pipe laid in existing trench of old pipe.
All as per item Ser No. 9.00 above but 25mm bore
All as per item Ser No. 9.00 above but 40mm bore
All as per item Ser No. 9.00 above but 50mm bore
S & F gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of bore of 20mm in replacement complete all as specified and directed by Engr-in-Charge.
All as per item Ser No. 13.00 above but 25mm bore
All as per item Ser No. 13.00 above but 40mm bore
All as per item Ser No. 13.00 above but 50mm bore
Repair of brick mesonary valve pit of size 120x120x120cm (Internal dinensions of chamber from top of PCC to bottom of cover)including excavation in any type of soil returning,filling around foundation and removal of surplus soil to a distance not exceeding 50m PCC 1:4:8 type D2 in foundation brick work in cement mortar 1:6 10mm thick plaster in cement mortar 1:4 to internal surface covered pit with MS sheet cover 3.15mm thick with locking arrangement handle fixing arrangement and painting with oil paint two coat over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
All as per item Ser No. 17.00 above but of size 900 x 900 x 900mm.
Replacement of CI sluice valve heavy duty of size 200mm bore, ISI Marked,flanged ends including suitable nut bolts washers, packing sheet,etc complete with necessary arrangements for fixing complete all as specified and directed by Engr-in-charge.
Replacement of CI sluice valve heavy duty of size 150mm bore, ISI Marked,flanged ends including suitable nut bolts washers, packing sheet,etc complete with necessary arrangements for fixing complete all as specified and directed by Engr-in-charge.
Replacement of CI sluice valve heavy duty of size 80mm bore, ISI Marked,flanged ends including suitable nut bolts washers, packing sheet,etc complete with necessary arrangements for fixing complete all as specified and directed by Engr-in-charge.
Dewatering of OHT by pump from clean water sump of size and capacity 1,00,000 Gln, taking out sludge and removing the same to a distance not exceeding 50m including cleaning the OHT by wire brushing/ brooming down complete fungus and applying one coat of white wash to internal surface of tank complete all as directed by the Engr-in -charge.
Dewatering of OHT by pump from clean water sump of size and capacity 50,000 Gln, taking out sludge and removing the same to a distance not exceeding 50m including cleaning the OHT by wire brushing/ brooming down complete fungus and applying one coat of white wash to internal surface of tank complete all as directed by the Engr-in -charge.
Dewatering of OHT by pump from clean water sump of size and capacity 60,000 Gln, taking out sludge and removing the same to a distance not exceeding 50m including cleaning the OHT by wire brushing/ brooming down complete fungus and applying one coat of white wash to internal surface of tank complete all as directed by the Engr-in -charge.
Cutting of existing CI/DI pipe 200/150 mm bore and inserting DI/CI coller/D Joint as per site requirement with all jointing materials such as lead joint and spun etc and testing the same including necessary excavation, returning filling all earth work complete all as specified and directed.
Cutting of existing CI/DI pipe 100/80 mm bore and inserting DI/CI coller/D Joint as per site requirement with all jointing materials such as lead joint and spun etc and testing the same including necessary excavation, returning filling all earth work complete all as specified and directed.
Rewinding of Submersible motor 3 phase, 45 HP, 50 c/s with PVC insulated coper wire of suitable gauge and size as per existing including all insulating material and replacement of ball bearing, bushes, greasing and testing complete. Note:- Rate quoted by the contractor shall deemed to be include, replacement of minor items like nut bolts packing etc and takingout and lowering of submersibnle motor as directed by Engr-in-Charge.
Rewinding of Submersible motor 3 phase, 7.5 HP, 50 c/s with PVC insulated coper wire of suitable gauge and size as per existing including all insulating material and replacement of ball bearing, bushes, greasing and testing complete. Note:- Rate quoted by the contractor shall deemed to be include, replacement of minor items like nut bolts packing etc and takingout and lowering of submersibnle motor as directed by Engr-in-Charge.
Rewinding of Submersible motor 3 phase, 10 HP, 50 c/s with PVC insulated coper wire of suitable gauge and size as per existing including all insulating material and replacement of ball bearing, bushes, greasing and testing complete. Note:- Rate quoted by the contractor shall deemed to be include, replacement of minor items like nut bolts packing etc and takingout and lowering of submersibnle motor as directed by Engr-in-Charge.
Disconecting the pump set from motor and dismantling the submersible pump 7.5 HP for carefully and shifting & transporting pump set to work shop for testing inpection, lowering down the pump carefully after repair and connecting phase supply and testing the pump set on load. However the repair parts reuired will be, measured and paid for separately against item No.31 to 44.
Supply only following spare parts for against of item No.30 Gun metal impeller
Stainless steel shaft
CI stage bowl
Brass neck ring.
Thrust pad.
Distance sleeve.
Motor bush
Sealing Kit.
Thrust plate.
Pump coupling stainless steel with key
Sand guard
Stud & Nut
Motor Rotor bleaching
Motor pump housing
Replacement of damaged and rusted galvanised iron medium grade flanged column pipe 100mm dia ISI marked 3 Metre long each duly flanged at both ends by welding with special provisions such as MS supporting/slots for housing 02 Nos submersible cable including nuts, bolt washers and rubber gaskets etc complete all as specified and directed.
Replacement of damaged and rusted galvanised iron medium grade flanged column pipe 80mm dia ISI marked 3 Metre long each duly flanged at both ends by welding with special provisions such as MS supporting/slots for housing 02 Nos submersible cable including nuts, bolt washers and rubber gaskets etc complete all as specified and directed.
First Aid Chart with clear glass cover & wooden frame complete all as specfied.
All as per Sri item No.47 but shock treatment chart.
Supply only First Aid Kit box No.8 (Size 360mmx150mmx80mm) caintaining following items.(a) Dettols bottle 100 ml 02 Nos.(b) Antiseptic Ointment 100 Mg (c) Crocin tabletes 01 strips (Containing 10 tablets each) (d) Hydrogen peroxide 50 ml 01 bottle.(e) Cotton small rolls 02 Nos (f) Move tube 01 Nos (g) Betadine tube 100mg (h) Cotton strip small roll. 04 Nos.
Orthtodoline solution for chlorine test in 500 ML bottle complete all as specified complete.
Supply only Chlorine test kit up to 2 PPM.
Supply only calcium based Hypochlorite 65% to 70% calcium based white to off white free flowing soilg granular chlorination in 45 Kg packing complete. Make : Aquafit of M/s Sree Rayaiaseema HI- Strength Hypo Ltd/Declibac Tech (P) Ltd.
De watering, raking of alage, desilting in all respect of stroage water tanks of size 8m x 8mx3.048m
Taking down cement plaster on brick walls built in cement mortar incl racking out joints hacking for key, scurbing down with water etc.
Rendring 10mm thick in cement mortar 1.3 on brick or concrete surface with water proofing compound @ 3% weight of cement and finishing the surface even and fair all as specified (water proofing compound to be provided separate).
Supply only integral water proofing compound.
Preparation and priming of old and new surface and applying two coats of alkeli resistant paint over the treated surface.
M&L rolled mild steel channel, angle or tee section fixed independity without connecting plates etc (Cut to ordinary lengths i.e with in 20mm of length indicated.
4mm dia galvanised steel wire 150x100mm mesh,made up into mattresses or cages, lapped, wired nand laid in position incl closing after filling as in repairs.
S&F mild steel butt hinges cold rolled of size 75mm medium weight.
M&L preparing old steel surfaces and applying two coats of synthetic enamel paint over a coat primer, complete all as specified and as directed.
M&L preparing surface of new steel and applying two coats of synthetic enamel paint over a coat primer, complete all as specified and as directed.
SANGAM ENGINEERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .