| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 LAccepted-AOC 114 BARH CHONDI TOWN BARH DISTT PATNA BIHAR PIN 803213 | PATNA | BIHAR | 803213 | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹36.8 L+₹2.7 L (7.87%)Rejected-Finance 316 A VIJAY NAGAR EXTENSION RANJHI MAIN ROAD JABALPUR MP PIN 482005 | JABALPUR | MADHYA PRADESH | 482005 | L2 | Rejected-Finance Second Lowest amount quoted | |
| 3 | L3₹37.7 L+₹3.5 L (10.4%)Rejected-Finance 114 BARH CHONDI BARH PATNA BIHAR 803213 | PATNA | PATNA | BIHAR | 803213 | L3 | Rejected-Finance Third Lowest amount quoted | |
| 4 | L4₹39.1 L+₹5.0 L (14.6%)Rejected-Finance 403 NARSINGH NAGAR RANJHI JABALPUR MP PIN 482005 | JABALPUR | JABALPUR | MP | 482005 | L4 | Rejected-Finance Fourth Lowest amount quoted | |
| 5 | L5₹41.0 L+₹6.8 L (20.0%)Rejected-Finance | L5 | Rejected-Finance Fifth Lowest amount quoted |
| Sl No | Description | Qty | Unit | LAL SINGH & SONS L4 | MAA SHARDA CONSTRUCTION L3 | SR ASSOCIATES L5 | R R VISHWAKARMA CONSTRUCTION CO L6 | M/s Brij Constructions L1 | M/S A.P.M. CONSTRUCTION CO. L2 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of brick work or stone/boulder masonry, built in CM or cement lime mortar including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. | 71.75 | Cum | 180 ₹12,915 | 150 ₹10,762.5 | 200 ₹14,350 | 500 ₹35,875 | 99 ₹7,103.25 Lowest | 180 ₹12,915 |
| 2.00 | M&L brickwork with old size flyash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified & directed. | 73.5 | Cum | 5,000 ₹3,67,500 | 4,300 ₹3,16,050 Lowest | 5,300 ₹3,89,550 | 5,500 ₹4,04,250 | 4,799 ₹3,52,726.5 | 4,800 ₹3,52,800 |
| 3.00 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed | 150 | Sqm | 30 ₹4,500 | 10 ₹1,500 | 10 ₹1,500 | 20 ₹3,000 | 9 ₹1,350 Lowest | 20 ₹3,000 |
| 4.00 | M&L rendering 15 mm thick on fair faces of brick work or concrete surfaces of wall in CM 1:6 and to be finished even and smooth (without using extra cement) complete all as specified and directed. | 638 | Sqm | 200 ₹1,27,600 | 200 ₹1,27,600 | 220 ₹1,40,360 | 300 ₹1,91,400 | 179 ₹1,14,202 Lowest | 180 ₹1,14,840 |
| 5.00 | M&L preparation of newly plastered or unplastered brick work or concrete surfaces & applying three coats of white wash on prepared brick work or concrete surfaces complete all as specified and directed. | 58 | Sqm | 12 ₹696 | 18 ₹1,044 | 13 ₹754 | 30 ₹1,740 | 19 ₹1,102 | 6 ₹348 Lowest |
| 6.00 | M&L preparation of newly plastered or unplastered brick work or concrete surfaces & applying two coats of cement based paint over and including one coat of alkali resistant priming paint on prepared brick work or concrete surfaces complete all as specified and directed. | 108 | Sqm | 40 ₹4,320 | 50 ₹5,400 | 22 ₹2,376 Lowest | 50 ₹5,400 | 29 ₹3,132 | 35 ₹3,780 |
| 7.00 | Demolition of Cement Concrete (unreinforced) of any description & in any position not otherwise specifically provided for complete all as specified and directed. | 218.5 | Cum | 260 ₹56,810 | 250 ₹54,625 | 250 ₹54,625 | 500 ₹1,09,250 | 199 ₹43,481.5 Lowest | 250 ₹54,625 |
| 8.00 | M&L Cement Concrete Type D-2, 1:4:8 (using 40 mm graded stone aggregate) as in sub base, foundations, filling and mass concrete complete all as specified and directed. | 110 | Cum | 3,000 ₹3,30,000 | 2,300 ₹2,53,000 | 4,000 ₹4,40,000 | 3,000 ₹3,30,000 | 2,199 ₹2,41,890 Lowest | 2,900 ₹3,19,000 |
| 9.00 | M&L Machine pressed precast concrete interlocking paver block any shape & size confirming to IS 15658 - 2006 of 80 mm thickness M-40 Grade with grey cement & no pigment complete all as specified and directed. | 100 | Sqm | 870 ₹87,000 | 900 ₹90,000 | 866 ₹86,600 | 1,000 ₹1,00,000 | 669 ₹66,900 Lowest | 750 ₹75,000 |
| 10.00 | M&L Sand filling under floors or in foundations including watering & consolidation complete all as specified and directed. | 10 | Cum | 600 ₹6,000 | 900 ₹9,000 | 1,000 ₹10,000 | 500 ₹5,000 Lowest | 1,099 ₹10,990 | 2,000 ₹20,000 |
Tender Value
₹48.5 L
EMD Value
₹97,100
Closing Date
18 Jul 2025, 6:00 pmClosed
Lt Col P Aditya Deepak, GE
Garrison Engineer (East), Near COD Estate, Ranjhi, Jabalpur (MP)-482011
SPECIAL REPAIR TO DRAINAGE, CULVERT, RCC HUME PIPE, GATE, CHAIN LINK FENCING, HARD STANDING AND CERTAIN B/R MISC WORKS AT LEKHANAGAR JABALPUR UNDER AGE B/R-I OF GE (EAST) JABALPUR
2025_MES_715530_1
8765/E8
Open Tender
Civil Works
Item Rate
240 days
Garrison Engineer (East) Jabalpur
Class D Cat a (i)
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer (East) Jabalpur
₹97,100
Yes
27 Aug 2025
19 Jun 2025
21 Jul 2025
19 Jun 2025
18 Jul 2025
4 Jul 2025
19 Jun 2025 - 26 Jun 2025
Amount
Demolition of brick work or stone/boulder masonry, built in CM or cement lime mortar including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L brickwork with old size flyash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified & directed.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed
M&L rendering 15 mm thick on fair faces of brick work or concrete surfaces of wall in CM 1:6 and to be finished even and smooth (without using extra cement) complete all as specified and directed.
M&L preparation of newly plastered or unplastered brick work or concrete surfaces & applying three coats of white wash on prepared brick work or concrete surfaces complete all as specified and directed.
M&L preparation of newly plastered or unplastered brick work or concrete surfaces & applying two coats of cement based paint over and including one coat of alkali resistant priming paint on prepared brick work or concrete surfaces complete all as specified and directed.
Demolition of Cement Concrete (unreinforced) of any description & in any position not otherwise specifically provided for complete all as specified and directed.
M&L Cement Concrete Type D-2, 1:4:8 (using 40 mm graded stone aggregate) as in sub base, foundations, filling and mass concrete complete all as specified and directed.
M&L Machine pressed precast concrete interlocking paver block any shape & size confirming to IS 15658 - 2006 of 80 mm thickness M-40 Grade with grey cement & no pigment complete all as specified and directed.
M&L Sand filling under floors or in foundations including watering & consolidation complete all as specified and directed.
M&L Hardcore of broken stone or boulders of gauge n.exc. 63 mm, deposited, spread and levelled in layers n.exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L coloured rubber moulded chequered cement concrete tiles 20 cm x 20 cm x 25 mm thick, set, jointed & pointed in neat cement slurry in floors with grey cement & pigment over & including 20 mm thick screed bed or bedding layer of 1:6 CM for laying floor finishes complete all as specified and directed.
M&L Heavy Duty Vitrified Ceramic tiles 10 mm thick (Square/ Rectangular) polished, area of each tiles n.exc 0.36 sqm, in floors etc., set & jointed in neat cement slurry & pointed in white or coloured cement to match over & including 15 mm thick screed bed or bedding layer of 1:6 CM for laying floor finishes complete all as specified and directed.
M&L Cement Concrete Type B-1, 1:2:4 using 20 mm graded stone aggregate as in path/ hard standing surface finished even and fair complete all as specified and directed.
M&L forming construction joint 90 mm deep x 10 mm wide filled with grade 'A' sealing compound complete all as specified and directed.
Excavation in trenches in soft/loose soil, n.exc 1.5 metre wide and n.exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 sqm on plan and getting out complete all as specified and directed.
M&L Moorum/ Red Bajri filling in floors or pavings, laid in layers n.exc 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M&L Cement Concrete Type B-1, 1:2:4 using 20 mm graded stone aggregate as in surface channels & drains complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
Add or Deduct for each 25 mm girth or part thereof over or under 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
M&L providing Cement Concrete Type B-1, 1:2:4 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, cills, steps; seismic & other similar bands, plinth courses, string courses, lacing courses, parapets & railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs & the like including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
Demolition of Cement Concrete (reinforced) of any description & in any position not otherwise specifically provided for complete all as specified and directed.
M&L Providing Precast Cement Concrete Type B-1, 1:2:4 using 20mm graded stone aggregate as in landings, cover slabs (for manholes etc.), chullah hoods, chajjas, water troughs, mangers, shelves & similar articles with plain faces including necessary chamfers, weatherings, throating etc. & setting in CM 1:6 including necessary formwork if required complete all as specified and directed.
S&F of Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with & including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Returning, filling in soft/ loose soil, including spreading, levelling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed.
Removing surplus excavated material (soil) to a distance n.exc 50 metre & depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
Demolition & breaking up of 300 mm Internal dia, drain pipes (Salt glazed ware, AC or Reinforced Concrete) set in CM complete all as specified and directed.
Demolition & breaking up of 450 mm Internal dia, drain pipes (Salt glazed ware, AC or Reinforced Concrete) set in CM complete all as specified and directed.
Demolition & breaking up of 600 mm Internal dia, drain pipes (Salt glazed ware, AC or Reinforced Concrete) set in CM complete all as specified and directed.
M&L Reinforced Cement Concrete Pipes, Class NP3, 300 mm bore laid & jointed complete with collars complete all as specified and directed.
M&L Reinforced Cement Concrete Pipes, Class NP3, 450 mm bore laid & jointed complete with collars complete all as specified and directed.
M&L Reinforced Cement Concrete Pipes, Class NP3, 600 mm bore laid & jointed complete with collars complete all as specified and directed.
M&L Cement Concrete bed Type C-2, 1:3:6 (using 40 mm graded stone aggregate) to 300 mm bore drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
M&L Cement Concrete bed Type C-2, 1:3:6 (using 40 mm graded stone aggregate) to 450 mm bore drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
M&L Cement Concrete bed Type C-2, 1:3:6 (using 40 mm graded stone aggregate) to 600 mm bore drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
Dismantling posts or sturts (wood, steel or R.C.C.) any section embedded in concrete, brickwork, masonry, etc., including taking out embedded portion and making good disturbed ground complete all as specified and directed.
Dismantling fencing wire mesh, any type complete all as specified and directed.
Excavation in post holes (or similar holes) each not exceeding 0.50 cum in soft/loose soil, getting out, returning, filling in & ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering & removing surplus soil to a distance not exceeding 50M & making good surface complete all as specified and directed.
M&L Cement Concrete Type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
S&F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, driiling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc. and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F mild steel round bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to Fe-410-W (Gde E-250) quality-A or Fe-290 (Gde-E-165) complete all as specified and directed.
S&F Mild steel screw bolts (Machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5 cm but not exc 10 cm long, diameter of neck 11 to 15 mm complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc., including provision of binding wire complete all as specified and directed.
Supply only Chain link MS galvanised fencing any size or type complete all as specified and directed. Note : Weight of chain link shall be assessed by BOO conveyed by GE.
M&L Framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc., complete drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel, sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete quality conforming to Fe 410-W (Gde-E-250) quality-A complete all as specified and directed.
M&L preparation of new or previously untreated surfaces of steel of any description, not exc 10 cm in width or girth when unconnected with other painting or when painted in a different tint & apply two coat of synthetic enamel paint (ordinary tint) over & including one coat of red oxide, zinc chrome primer complete all as specified and directed.
M&L preparation of new or previously untreated steel surfaces of any description, over 10 cm in width or girth, not otherwise described & applying two coats of synthetic enamel paint (ordinary tint) over & including one coat of red oxide, zinc chrome primer complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
M&L Providing precast cement concrete louvres and jallies, 35 mm thick (measured solid), Type B-0, 1:2:4 (using 12.5 mm graded aggregate) including all mouldings but excluding frame, set in CM 1:6 including necessary formwork if required complete all as specified and directed.
S&F Mild steel TMT bars 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with & including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
S&F Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290 Gde-E-165 complete all as specified and directed.
M&L Machine pressed precast concrete interlocking paver block any shape & size confirming to IS 15658 - 2006 of 60 mm thickness M-35 Grade with grey cement & no pigment complete all as specified and directed.
Use and waste of Form Work to faces of walls, retaining walls, abutments, parapets & staircase railings & similar work including attached pillasters, buttresses, etc., vertical or to batter, fair finished flat surfaces of concrete complete all as specified and directed.
M&L RCC M-25 design mix in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and directed.
Use and waste of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
M&L RCC M-25 design mix in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
Use and waste of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
M&L Reinforced cement concrete M-25 (design mix) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L Reinforced cement concrete M-25 (design mix) as in Columns, pillars, piers, posts and struts complete all as specified and directed.
Use and waste of Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed.
M&L steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979, Gde St-240 and painted one shop coat of zinc chromate primer paint (including preparation of surface) at contractor's workshop before fabrication complete all as specified and directed.
M&L 3mm thick colour ACP sheet in strips & channel feathered at the edges for fixing on ALUMINIUM solid Wall Lining inclusive of all fixture complete all as specified and directed.
Excavation over area n exc 1.5m deep and getting out in soft/loose soīl complete all as specified and directed.
Excavation over area exc 1.5m but n.exc 3.00m deep and getting out in soft/loose soīl complete all as specified and directed.
Schedule of credit amount of Rs. 170716.25 to be deducted during AOC.
M/S A.P.M. CONSTRUCTION CO. (BID ID -3360934)
MAA SHARDA CONSTRUCTION (BID ID -3355143)
LAL SINGH & SONS (BID ID -3355077)
SR ASSOCIATES (BID ID -3355624)
R R VISHWAKARMA CONSTRUCTION CO (BID ID -3361560)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .