Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 LAccepted-AOC | ₹9.7 L | L1 | Accepted-AOC Accepted in estimate rates by the University rules and regulations |
| 2 | L2₹9.9 LRejected-AOC | ₹9.9 L | L2 | Rejected-AOC Not Accepted |
| 3 | Not Admitted-Fee/PreQual/Technical NEAR SADHURAM SCHOOL RAGHUNATHGANJ KATNI MADHYA PRADESH 483501 | KATNI | MADHYA PRADESH | 483501 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | KAVYA BUILDERS& CO L2 | S M BUILDERS L1 |
|---|---|---|---|---|---|
| 1.00Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of walls | |||||
| 1.01 | a) Doors and windows including removal of frames hinges and fastenings | 10 | m² | 170 ₹1,700 | 160 ₹1,600 |
| 1.02 | b) floor finish and dadooing walls in cement mortar with mosaic tiles/ Glazod tiles/clay tiles/cuddaph slabs | 30 | m² | 80 ₹2,400 | 65 ₹1,950 |
| 1.03 | c) Pressed tiles and weathering course | 10 | m² | 50 ₹500 | 50 ₹500 |
| 2.00BRICK WORK in cement mortar 1:5 (One cement and five crushed stone sand) using Fly ash bricks of size (230 X 110 X 70 mm) for the following including curing etc., complete complying with standard specifications. (Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost). | |||||
| 2.01 | a) For Foundation and basement | 5 | m³ | 7,900 ₹39,500 | 7,890 ₹39,450 |
| 2.02 | b) In Super Structure ground floor | 2 | m³ | 8,050 ₹16,100 | 7,950 ₹15,900 |
| 3.00Brick partition walls of 11.50cm thickness using best quality II class table moulded chamber burnt bricks of size 9" x 4-3/8" x 2-3/4" in Cement Mortar 1:3 (One Cement and Three M Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the University Engineer. (Hoop iron reinforcement will be measured and paid for separately) | |||||
| 3.01 | a) In ground floor | 15 | m² | 1,060 ₹15,900 | 1,020 ₹15,300 |
| 4.00 | Plastering with Cement Mortar 1:3 (One cement and Three M sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the University Engineer. | 70 | m² | 350 ₹24,500 | 320 ₹22,400 |
Tender Value
₹9.7 L
Closing Date
10 Dec 2025, 4:00 pmClosed
REGISTRAR
Registrar Bharathiar University Coimbatore
Special Repair works to kannamma hostel in Bharathiar University
2025_HE_629249_1
BU/UE/RE/067/202504.12.2025
Limited
Civil Works
100 days
Coimbatore
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
Exempted
10 Feb 2026
5 Dec 2025
11 Dec 2025
5 Dec 2025
10 Dec 2025
5 Dec 2025
Amount
Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of walls
a) Doors and windows including removal of frames hinges and fastenings
b) floor finish and dadooing walls in cement mortar with mosaic tiles/ Glazod tiles/clay tiles/cuddaph slabs
c) Pressed tiles and weathering course
BRICK WORK in cement mortar 1:5 (One cement and five crushed stone sand) using Fly ash bricks of size (230 X 110 X 70 mm) for the following including curing etc., complete complying with standard specifications. (Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost).
a) For Foundation and basement
b) In Super Structure ground floor
Brick partition walls of 11.50cm thickness using best quality II class table moulded chamber burnt bricks of size 9" x 4-3/8" x 2-3/4" in Cement Mortar 1:3 (One Cement and Three M Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the University Engineer. (Hoop iron reinforcement will be measured and paid for separately)
a) In ground floor
Plastering with Cement Mortar 1:3 (One cement and Three M sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the University Engineer.
Plastering with Cement Mortar 1:5 (One cement and Five M sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the University Engineer.
Plain Cement Concrete 1:2:4 (One cement, two M sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the university Engineer.
a) For Ground floor
Flooring with self designed colour ceramic tiles of size 0.305 x 0.305 x 6mm thick laid over 20 mm thick cement mortar 1:3 (One Cement and M Three Sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification and as directed by the University Engineer. (The make and brand of the tiles should be got approved by University Engineer before use on works)
Dadooing walls with best approved quality, colour glazed tiles of size 0.30 x 0.20 x 6mm thick set in Cement Mortar 1:2 (One Cement and M Two sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the University Engineer.
Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the University Engineer.
Pointing the joints of machine pressed tiles in Cement Mortar 1:3 (One Cement and Three M Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the University Engineer.
Providing and fixing P.V.C. Rainwater Downfall pipes of 110mm diametre with necessary shoes, bends and other speicals, clamps, screws, nails, teakwood plugs etc., complete including cost of all materials. The rate is to include cost of removable cast iron Gratings of appropriate size. The size of teakwood plugs to be used is 150mm * 25mm in front and 200mm * 75mm in rear and all other sides with a depth of 100mm. The pipe is to be fixed by means of "U" clamps at the cnetre of the pipe screwed to the plugs. The special type of 'U' clamps at the centre of the pipe to be fixed in addition to these for more than three metres pipe length, complete complying with standard specification and as directed by the University Engineer.
Supplying and fixing position PVC Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the University Engineer before use on works)
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the University Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level
a) 75mm dia
a) 110mm dia
a) 160mm dia
Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the University Engineer before use on works).
I) PVC ELBOW a) 75mm dia
b) 110mm dia
c) 160mm dia
II) PVC DOOR ELBOW a) 75mm dia
b) 110mm dia
c) 160mm dia
III) PVC TEE a) 75mm dia
b) 110mm dia
c) 160mm dia
IV) PVC TEE WITH SINGLE DOOR a) 75mm dia
b) 110mm dia
c) 160mm dia
Supplying and fixing in position of Solid PVC DOOR SHUTTERS using 19 gauge 19mm MS Sq. tubes for styles and outer frames. 15 mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC sheets. Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The overall size of styles shall be 50 x 30 mm. The overall size of top rail, lock rail and bottom rail shall be 75 x 30 mm The overall size of frames sshall be 50 x 45 mm, with suitable rabate for housing the shutter. etc., complete as directed by the University Engineer
Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm colour glazed earthern ware of approved quality and brand with "P" or "S" trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to PVC pipes (including the cost of 110mm dia PVC pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specification and as directed by the University Engineer. (The water closet should be got approved by the Executive Engineer before use on works).
Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm "P" or "S" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications. (The EWC and flushing tank wiht all accessories should be got approved by the University Enginer before use on works)
Supplying ,fabricating and fixing in position of steel frame without bottom frame, of size 100X60mm rectangular section with necessary rebate 30mmX15mm, to host the shutter,using 1.25mm thick (18 guage) CRCA cold rolled frame steel plate confirming to ISI specified ensured of right butt joint riveted hold assembly with nylon insert,not be welded with special purpose hard ware.Proclaimed including phopating as per ISI with rust preventive primer ready to assemble condition for easy installation at site including dismantling,making necessary chipping and holes in RCC columns, walls with power drills to the extent required ,including providing concrete 1:2:4 inside the box curing etc complete.The cost includes the cost of hold fast ,plastic bush, insert receiver,rubber bottom,shock absorber etc complete as directed by the University Engineer in all floors.
Supplying and fixing soild core flush shutters with commercial ply on both side with teak wood lipping alround 35 mm tk Complete complying with standard Specification and as directed by the University Engineer.
White washing two coats with freshly burnt white shell lime in all floors including cost of lime, blue powder fevicol type gum, brushes, scaffolding charges, etc., complete complying with standard specification and as directed by the University Engineer.
Supplying and painting the walls with two coats of oil bound distember over one coat of water based cement primer including cost for distemper, primer, cleaning and scrapping the walls, rendering the walls smooth with necessary putty, brushes, scaffolding arrangements, labour charges, etc., as per standard specification. (The colour and shade of the distemper shall be got approved by the University Engineer before use of work).
Painting two coats with Oil bound distember of approved quality and colour including preparation of surface etc., complete complying with standard specification and as directed by the University Engineer. (The paint to be used should be got approved by the University Engineer before use on work.)
Distempering the old wall and ceiling one coat with best oil bound distember of approved quality including preparation of surface, the rate includes cost of brushes, high scaffolding arrangements, neat finishes, etc., complete complying with standard specification and as directed by the University Engineer.
PAINTING ONE COATS for wall surfaces using synthetic enamel paint of approvedcolour over in all floors. The rate is inclusive of cost of all materials and labour, brushes and scaffolding charges etc., complete complying with standard specification. (The paint to be used should be got approved by the University Engineer before use on work.)
Painting old iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with one coat of best approved first quality and colour of synthetic enamel paint in all floors etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the University Engineer before use on works.)
Painting old wood works with one coat of best approved synthetic enamel paint over existing coat for doors, windows, in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the University Engineer before use on works.)
Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the University Engineer before use on works.)
Supplying and painting the walls with two coats of cement paint over one coat of cement primer as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications (The colour and shade of the cement paint shall be got approved by the University Engineer before use of work).
Supplying and painting the walls with two coats of cement paint as instructed by the University Engineer including preparation of surface curing, etc., complete in all floors complying with standard specifications (The colour and shade of the cement paint shall be got approved by the University Engineer before use of work).
Supplying and fixing in position of Aluminium natural colour partition with 63.50x38.10x 1.28mm @ 0.805 Kg/m extruded box section at bottom, vertical members spaced at 1.20m,2.10m and 2.40m height. The vertical members are spaced at 90cm c/c at equal height.Alu. Clips: 17.3x17.00x0.70mm @ 0.097kg/m The bottom and top panels shall be covered with Medium Density Fibre (MDF) Board 12mm thick Exterior Grade both sides pre-laminated and the centre panels shall be fixed with 5.5mm thick plain glass with necessary glazing clips, rubber beedings etc., including necessary dismantling making holes in RCC columns, beams, masonry wherever necessary with power drill to the extent required and make good to the original condition after fixing. The aluminium surfaces is to be anodized with natural colour finish under Electrically controlled condition in accordance with ISI 1868/1962 specification for an average anadic film thickness of not less than 15 microns. All materials and colour should be got approved by the University Engineer.
Supplying, fabricating and fixing in position of Aluminium natural colour partition finish of double leaves door with half panelled with 12mm thick bothside prelaminated partile board at bottom and half glazed using 5.50mm thick Plain glass at top.The bottom frame shall be made out of Aluminium rectangular section of size 95.25 X 44.50 X 1.70mm at 1.301 Kg/m. The top frame 47.62 x 44.45 x 1.74mm @ 0.881kg/m, centre mullions 49.91 x 44.45 x 1.30 @ 0.753kg/m and vertical styles with 47.6 2x 44.45 x1.62 @ 0.881kg/m. The door shutter shall be fixed with necessary accessories such as rubber beading for fixing novapan sheet and for fixing glass,aluminium tower bolts, Handle, lock,PVC felt etc., including cost of materials, labour charges and power consumption charges required for fabrication.All the aluminium sections are to be anodized with matt finish under electrically controlled condition in accordance with I.S. 1968/1962 for an average anodized film thickness of not l`ess than 15 microns and the materials to be used should be got approved by the Executive Engineer before use on work.
Removing and Repairing of existing Aluminium partition ,doors with locking arrangements, handles, rubber beadings and scres.Including cost of all materials and labour charges coomplete complying with standard specification and as directed by the University Engineer.
KAVYA BUILDERS& CO (BID ID -1530815)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.52 MB
BOQ_752461.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid