Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹5.8 LAdmitted-Finance | +22.00% | ₹5.8 L | L1 | Admitted-Finance |
Tender Value
₹4.7 L
EMD Value
₹9,470
Closing Date
19 May 2026, 3:00 pmClosed
AGM(EM), RO Manipur
FCI RO Manipur, Imphal-795001
Work for Replacement of cable and street light for restoration of street light on poles along the periphery of the godown at FSD Churachandpur under Manipur region
2026_FCI_907451_1
01/Engg/EM/Manipur/2026-27
Open Tender
Electrical Works
Percentage
45 days
Churachandpur
Please refer Tender documents
4 documents required · 4 mandatory
₹0
₹9,470
15 Jul 2026
5 May 2026
20 May 2026
5 May 2026
19 May 2026
5 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying, Installation, Testing & Commissioning of Street light LED fixture (45 WATT) , powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC,frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (Asper ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the pecified rating and Fixture shall be of relevant BIS standard complete in allrespect i/c external connections with 1.5 sq mmFRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixturesas per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge asper requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). | 25 | Each | 1,966 | ₹49,150 |
| 2 | Supplying and fixing of 32 mm dia X 1.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required | 25 | Each | 1,511 | ₹37,775 |
| 3 | Supply 2x10 sqmm PVC insulated and PVC sheathed/ XLPE POWER CABLE of 1.1 kV grade armoured Al. cable compulsory ISI mark conforming to IS:7098/ PART-I/ 88 e as required. | 470 | Mtr | 358 | ₹1,68,260 |
| 4 | Laying and fixing of one number PVC insulated andPVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) | 30 | Mtr | 64 | ₹1,920 |
| 5 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sqmm | 410 | Mtr | 453 | ₹1,85,730 |
| 6 | Laying of one No. PVC insulated & PVC sheathed/XLPE POWER CABLE of 1.1 kv grade aof follwing size in existing masonry open duct as required. Upto 35 sqmm. | 30 | Mtr | 36 | ₹1,080 |
| 7 | P/F of cable termination of M.S. box of size 15cm X 15cm X 10 cm with compression termination arrangements, 6-10 Amp SP MCB and double natural link etc as required. | 16 | Each | 1,352 | ₹21,632 |
| 8 | Supplying and drawing following sizes of FRLS/HFFRPVC insulated copper conductor, single core cable inthe existing surface/ recessed steel/ PVC conduit as required.3x1.5 sqmm | 75 | Mtr | 104 | ₹7,800 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.80 MB
DNITsigned.pdf
Tender Documents • 2.61 MB
BOQ_953792.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].