Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹70.0 LAccepted-AOC NO 1 48L ELUMALAI GOUNDER NAGAR NARASOTHIPATTY POST SALEM DISTRICT 636004 | SALEM | SALEM | TAMIL NADU | 636004 | ₹70.0 L Quoted ₹71.1 L | L1 | Accepted-AOC The Lowest and Negotiated tender is accepted by the Chief Engineer PWD., Coimbatore region, Coimbatore vide Lr.No.HDO/DB/F.12/2025/Dt.29.12.2025 |
| 2 | L2₹73.5 LRejected-AOC | ₹73.5 L | L2 | Rejected-AOC Other than lowest tenderer |
| 3 | L3₹76.8 LRejected-AOC NO 139 CONVENT ROAD ALAGAPURAM SALEM 16 | SALEM | SALEM | TAMIL NADU | ₹76.8 L | L3 | Rejected-AOC Other than lowest tenderer |
| Sl No | Description | Qty | Unit | Jaya Sudha Electrical Contractor L1 | Karhirvel Electrical works L2 | KKP ELECTRICALS L3 |
|---|---|---|---|---|---|---|
| 1.00 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) (Higher End )SD 289 | 174 | Pts | 2,970 ₹5.2 L | 3,071 ₹5.3 L | 3,210 ₹5.6 L |
| 2.00 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End SD 293 | 47 | Pts | 2,500 ₹1.2 L | 2,593 ₹1.2 L | 2,710 ₹1.3 L |
| 3.00 | Wiring with 3 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A two way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC pipe Stair case Light point Higher End SD 309 | 6 | Pts | 3,770 ₹22,620 | 3,899 ₹23,394 | 4,075 ₹24,450 |
| 4.00 | Supply and fixing of 4 Feet LED 20W Fitting with LED 20W tube (Higher End) complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting (SD-443) | 121 | Nos | 1,100 ₹1.3 L | 1,132 ₹1.4 L | 1,183 ₹1.4 L |
| 5.00 | Supply and fixing of 24W LED 2x2 square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting. (SD-448) | 12 | Nos | 3,800 ₹45,600 | 3,936 ₹47,232 | 4,115 ₹49,380 |
| 6.00 | Supply and fixing of 9W LED Lamp for BH point. (DATA-1) | 22 | Nos | 235 ₹5,170 | 244 ₹5,368 | 255 ₹5,610 |
| 7.00 | Supply and fixing of WT bulk head fitting with guard suitable with 7W / 9W LED bulb. (SD-84) | 5 | Nos | 700 ₹3,500 | 721 ₹3,605 | 754 ₹3,770 |
| 8.00 | Supply and fixing of 1200mm (48") Sweep BLDC ceiling fan complete (HIGHER END) with 2 Module 100 W Fan Step Regulator (HIGHER END) with stepped with 300mm down rod on the existing fan clamp (DATA-2) | 20 | Nos | 3,200 ₹64,000 | 3,300 ₹66,000 | 3,450 ₹69,000 |
| 9.00 | Supply and fixing of 300mm (12") sweep (light duty) AC exhaust fan complete with necessary wall opening and making good of the wall. (SD-114) | 19 | Nos | 2,500 ₹47,500 | 2,555 ₹48,545 | 2,671 ₹50,749 |
| 10.00 | Supply and fixing of louvers shutters arrangements for 300mm (12") sweep (light duty) AC exhaust fan. (SD-120) | 19 | Nos | 525 ₹9,975 | 540 ₹10,260 | 564 ₹10,716 |
Tender Value
₹70 L
EMD Value
₹45,000
Closing Date
19 Dec 2025, 3:00 pmClosed
The Superintending Engineer PWD
Buildings C and M Circle Salem.
Provision of Internal and External Electrification and bed cum passenger lift arrangements to the maternal and child health wing in Government Hospital at Attur in Salem District.
2025_PWD_628488_1
37/2025-26
Open Tender
Electrical Works
150 days
Attur in Salem District.
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹45,000
17 Feb 2026
4 Dec 2025
19 Dec 2025
4 Dec 2025
19 Dec 2025
4 Dec 2025
Amount
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) (Higher End )SD 289
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End SD 293
Wiring with 3 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A two way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC pipe Stair case Light point Higher End SD 309
Supply and fixing of 4 Feet LED 20W Fitting with LED 20W tube (Higher End) complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting (SD-443)
Supply and fixing of 24W LED 2x2 square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting. (SD-448)
Supply and fixing of 9W LED Lamp for BH point. (DATA-1)
Supply and fixing of WT bulk head fitting with guard suitable with 7W / 9W LED bulb. (SD-84)
Supply and fixing of 1200mm (48") Sweep BLDC ceiling fan complete (HIGHER END) with 2 Module 100 W Fan Step Regulator (HIGHER END) with stepped with 300mm down rod on the existing fan clamp (DATA-2)
Supply and fixing of 300mm (12") sweep (light duty) AC exhaust fan complete with necessary wall opening and making good of the wall. (SD-114)
Supply and fixing of louvers shutters arrangements for 300mm (12") sweep (light duty) AC exhaust fan. (SD-120)
Supply and fixing of 1 no.6A two module 3 pin socket , 1 no. 6A one module switch on suitable module surface mounting Box (GI ) with module cover plate (plastic) on wall with connections. Higher End (SD-376)
Supply and fixing of 3nos.6A two module 3 pin socket , 3 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End.(SD-390)
Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End.(SD-402)
Supply and Fixing of 16A two way switch in suitable Modular type GI box on wall with suitable cover Plate with earth connection (Higher End) (for Lift well Lighting Control) (DATA-3)
Supply and fixing of 3nos.6A two module socket , 1 no. 6/16A two module socket , 3 nos. 6A one module switch, 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End (SD-438)
Supply and fixing of 20A Flush type Wall Socket 32A DP MCB complete set for AC Plug in flush with wall with earth connection (For AC Plug) (SD-144)
Supply and fixing of 32A DP MCB in Metal box DP enclosure in flush with wall and making good of the concealed portion with earth connection. (For OT Light) (DATA-4)
Supply and fixing of 63A FP MCB in Sheet steel FP enclosure in flush with wall and making good of the concealed portion with earth connection. (Higher End make). [1 No - 5.5TR Ductable A/C Unit] (DATA-5)
Supply and fixing of 63A FP MCB With 63 A FP 30mA RCCB in suitable sheet steel enclosure in flush with wall and making good of the concealed portion with earth connection only (Higher End) [1 No - 5.5TR Ductable A/C Unit & Lift Machine] (DATA-6)
Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End. [For Lighting] (SD-535)
Supply and fixing of 7 segment 4 way TPN MCB sheet steel distribution board (Higher end) with metal / acrylic door cover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and seperate 4 way provision for accomodating one no. 4 pole incoming MCB / Isolator and another seperate 4 way provision for accomodating one no. 4 pole ELCB / RCD (totally 8 ways in one segment) (3x 4 ways in each segment) and seperate provision for MCB / Isolators ( totally 12 nos.) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35 sq.mm. with the following in flush with wall with earth connection only. i)63A FP MCB - 1 No, ii)63A 4P 30MA ELCB - 1 No,iii) 63A DP MCB Isolator -3 Nos and iv)6A to 32A SP MCB - 12 Nos) (For Overall Lighting control each Floor) (SD-636)
Supply and fixing of 7 segment 8 way TPN MCB sheet steel distribution board (Higher end) with metal / acrylic door cover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and seperate 4 way provision for accomodating one no. 4 pole incoming MCB / Isolator and another seperate 4 way provision for accomodating one no. 4 pole ELCB / RCD (totally 8 ways in one segment) (3x 6 ways in each segment) and seperate provision for MCB / Isolators ( totally 18 nos.) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35 sq.mm. with the following in flush with wall with earth connection only. (i)63A FP MCB - 1 No, ii) 63A 4P 30MA ELCB - 1 No, iii) 63A DP MCB Isolator -3 Nos and iv) 6A to 32A SP MCB - 24 Nos)(Power DB) (SD-638)
Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire and making good of the concealed portion. [For 3x6A Computer Plug] (SD- 348)
Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire and making good of the concealed portion with suitable colour. [For , 20A A/C Plug, 6/16A Power Plug and 3Nos 6A & 1 No 6/16A Set Plugs, 16A Two way Switch & 8Way Lighting DBs] (SD-57)
Supply and run of 2 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 6 sq.mm copper wire and making good of the concealed portion with suitable colour [25A Modular Power plug box and 32A DP MCB] (SD-59)
Supply and run of 3 of 2.5 Sqmm (36/0.3) PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with continuous earth wire connection of 2.5 Sqmm copper wire with painting of suitable colour. [For Lift Well Wiring] (DATA-7)
Supply and run of 4 of 16 sq. mm (101/0.45) PVC insulated S.C unsheathed Cu. Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 16Sq.mm copper wire and making good of the concealed portion with suitable colour. [For 4W 7S TPN MCB DBs for lighting & 6W 7S TPN MCB DBs for Power] (DATA-8)
Supply and clamping of 3 ½ x 25 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps. [From 250A GF Panel to Lift Room] (SD - 205)
Supply and fixing of brass cable gland for 3½ x 25. sqmm PVC armoured LTUG cable with earth connection. (SD -164)
Supply and providing cable end termination of 3½ x 25 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete. (SD - 223)
Supply and Laying of 3 1/2 x 185 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. [From Existing panel board to 250A New panel board] (SD-675)
Supply and clamping of 3-1/2 x 185 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps. [From Existing panel board to 250A New panel board] (SD-212)
Supply and fixing of brass cable gland for 3-1/2 x 185 sq.mm. PVC armoured LTUG cable with earth connection. (SD-171)
Supply and providing cable end termination of 3-1/2 x 185 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete. (SD-230)
Supply, Erection, Testing & Commissioning of 250A capacity Dust & Vermin proof cubicle panel made out of 16SWG CRCA sheet steel enclosure with supply & fixing of the following interior mounting fuse switches with HRC fuses with a central bus bars chamber & two numbers of Horizontal cable chamber at top and bottom.250A FP SDF Double Break switch with HRC fuse units - 1Nos as incoming, Outgoings: 125A TP SDF Double Break switch with HRC Fuse units - 4Nos. 63A TP SDF Double Break switch with HRC Fuse units -6Nos. The bus bar chamber consist of 4nos. of 30mmx6mm Copper flat for three phases and neutral. The interconnection with the bus bars to the 250A SDF DB Switches with 30mmx6mm Copper flat, 125A SDF DB Switches with 30mmx3mm Copper flat and that 63A SDF DB Switches with No.8 SWG Copper Conductor
The buses should be mounted on the SMC bus insulator at proper & sufficient spacing between the buses as per IE rules.The bus bar chamber should be segregated from the adjacent chamber by providing hylem sheet of 6mm thick as partition 2 runs of 1"x¼" copper flat should be provided all around the panel for earth connection. Phase & Neutral copper buses should be provided with heat shrinkable sleeves using RYB & Black colours.. And Double earth connection to all the switches should be done using No.8 SWG Copper conductor. Indicator lamps should be provided with toggle switches & Bakelite fuse unit. The capacity of fuse switches, size and route location of the UG cable shall be superscribed on all the incoming and outgoing switches. The panel shall have one coat of red - oxide primer paint & two coats of synthetic enamel paint of approved colours, approved by the department officers and should be provided with danger board. The panel shall be mounted on 3” x 1 ½” x ¼” MS base channel provided all around the bottom of the panel. The whole arrangement shall be erected on a masonry pedestal to be constructed with suitable foundation with bolt and nuts, such that the lowest SDF unit fuse handle is at a height of 0.75m from the ground level (DATA9)
Earthing as per the ISI specification with an earth electrode of 2.1 mt class 'B' GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry.[2 Nos-Lifts&2 Nos-250A Panel board](SD-221)
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection. (SD-76)
Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection. (SD-372)
Supply, Installation, Testing, Commissioning and Handing over of 5.5 TR nominal Capacity ceiling supended ductable Air conditioner high tech, low height, low noise level indoor unit with fin and tube type cooling coil, Detachable type drier provided in refrigerant circuit to reduce moisture content multi-stage type distributor for feeding equal quantities of the refrigerant mixture to all the section of the coil with required valves, directly coupled blower to reduce troubles and wear & tear compared to drive blower. Thermostatic expansion valve lift and pull type aluminium framed durable, washable air filter. Integrated electrical panel with complete microprocessor control with display for easy operation and maintenance of unit common operating conditoners of 45deg F suction temperature. Auto reset ype HP/LP safety cut to improve relaibility of compressor. Type Quantity - Ceiling suspended Blower Quantity - 2 Nos. Motor quantity - 1 No. Weight - 72 Kg Air Flow - 4400 B) 5.5 TR capacity ceiling suspended ductable air conditioner high tech outdoor unit with power saving high efficiency sturdy and rugged 1 No. of scroll compressor each with in-built internal thermal protector, internal pressure relief valve, Auto reset type HP/LP safety cut out to improve reliability of compressor and
condenser shall be made of super slit high efficient aluminium fins mechanically bonded to copper tubes condenser 'L' type coil to be rigidly fixed to unit frame with fasteners, imported condenser fan & fan blades to be statically and dynamically balanced to reduce noise and vibration. The fans are direct driven 3 phase motor with protection. Condensing temperature 130deg.F for the system operations. Mounting - Rubber sleeve and unit Refrigerant - R22 (Non CFC) Speed - 2900 rpm Weight - 40.0Kg Capacity - 5.5 TR Voltages 415V - 3 Ph - 50Hz Consumption- 5.5 KW Type - Air cooled finned tube Tube diamter - 7/8" and 1 1/8 Fin type - Aluminium FPI - 14 No. of fan - 2 Nos. Dia - 24" No. of blade - 2 Nos. RPM - 900 (C) Commisioning : 1. Welding of Gas pipe lines (2) Leak Testing (3) Pressure testing (4) V accummissing (5) Dehydration (6) Time and temperature graph (As per SR) M-1993
Supply and fixing of Laminar Air flow Plenum for SS304 - 1.0 mm Thich casing, Mini Pleat Hepa Filters for 100mm Thick- Flange type, OT Pendant Light provision for 600X600, With SS304-1.2mm Thick perforated sheet. PLENUM SIZE: 1800L X 2400W X 350H High Efficiency particulate Air (HEPA) filter specification: Filter Size : 8 feet x 6 feet x 1 feet Classification : H-13 Construction :Panel Type Efficiency :99.97% Optical efficiency at .3 micron Cleanliness level: Class 100 As per NABH Standard Spacers: Aluminium Initial pressure drop:25 mm W.C Final pressure drop : 75 mm W.C Duct holding capacity:4750gm/Sq.mtr Framing :Aluminium (Box type) Washable : No Test reports to be furnished from approved Government External Quality Assurance Lab/ Agency to meet the testing parameters after commissioning of the AC system with HEPA filter as per NABH standards. (SR) M-2688
Supply, Fabrication and Installation of 22 G Sheet Aluminium Ducting for both suction and Return arrangement insulate with for Operation Theatres with inter linking arrangements with necessary angle supports, anchor fasteners and threaded rods etc... as required.SR M-3079
Supply, Fabrication and Installation of 22 G Sheet GI Ducting for both suction and Return arrangement insulate with for Operation Theatres with inter linking arrangements with necessary angle supports, anchor fasteners and threaded rods etc... as required. (M 2665)
Supply and providing 2 core 1.5 Sqmm Cu Flexible Cable in suitable Rigid Pipe on Wall (Control wiring).M-3076
Supply and filling of non-CFC Refrigerant Gas. (M 2002 )
Supply & fixing of hard drawn copper Refrigerant piping of suction line of Size (22.20mm) inches with necessary fitting and clamp etc…(M- 2050)
Supply & fixing of hard drawn copper Refrigerant piping of liquid line of size (15.90mm) inches with necessary fitting and clamp etc… ( M- 2052 )
Supply and fixing of flexible canvas connection between indoor unit and ducting and rubber pads, with ceiling Support angle rods etc... (M- 2004 )
Supply and fixing of 50mm thick anti vibrating rubber pads (M 2005 )
Supply and Providing Thermal Insulation of 9mm thick Class ‘O’ Fire Retardant –XLPE vidoflex with aluminium foil.(M -2016)
Supply and providing acoustic for initial portion of ducting with 12mm thick Fibre Glass Rigid Board covered with Tissue Paper and Aluminum Perforated Sheet. (M -2015 )
Supply and fixing of extruded aluminum powder coated, Supply and return Air Grilles / Diffusers with Volume Control Damper. ( M -2009 )
Supply, fabrication and fixing of Volume control dampers individually across the duct. ( M -2014)
Supply and fixing of 1 inch PVC water drain pipe line on wall with suitable Clamp as required. (M -2010 )
Supply, fabrication and fixing of suitable MS angle support frame for mounting the out door Units. (M -2012 )
Supply, fabrication and fixing of suitable MS angle support frame for mounting the indoor Units. ( M -2011 )
Supply and providing of pipeline nitrile rubber insulation for suction line Refrigerant pipe as required. (M -2013 )
Design, Engineering, Supply, Fabrication, Erection, Testing, Commissioning and Handing over of 1No.26 persons 1768 kgs. Capacity Passenger cum Bed Lift (Gearless) With Machine Room as per the following specifications. 1. Location : Maternal and Child Health wing in Government Hospital at Attur in Salem District. 2. No. of Lift : One No 3. Type of Lift : Bed cum passenger Lift with machine room - Gearless model 4. Capacity of Lift : 26 Persons / 1360kgs 5. Speed : 1.5 mtr / sec 6. Type of Drive : V3F Drive with enhanced ride comfort and near Zero Level Functions. 7. No. of Floors : Ground floor + 2 Floors 8. Total Travel : 10 Mtr / Pit 1800mm / Head room 4800mm 9. Leveling accuracy : High level accuracy with smooth and jerk free stopping. 10 Construction of Lift well : RCC with brick masonary. 11. Car : 1.5mm hairline finish High Quality S.S. Car and Hand rail, Granite anti skid flooring and Perspex False Ceiling. 12 Position of Machinery : Directly above the Lift well – Gearless with machine room. 13 No. of Landings : 3 Nos in the front side.
25 Emergency provisions : Battery operated Alarm bell & Light to be Provided with Automatic charging device. 26 Fire Man’s switch : In the Ground Floor 27 Minor Builder works : included 28 Scaffoldings : included 29 Sill angles and Facio Plates : included 30 Steel for Lift Machinery : included 31 Servicing and maintenance : Free Comprehensive Maintenance for one Year Guarantee period. 32 Automatic Rescue Device : Provision to facilitate the landing to the nearest floor at the time of power failure. The ARD consists of suitable Battery system with charger, Inverter, under voltage protection system etc. complete with all accessories. 33 Provision for Intercom : To be provided in the Ground Floor & Machine Room with Phone (Press & Speak). 34 Lift License : Preparation of Drawings, payment of inspection charges to CEIG and insurance policy and Obtaining CEIG approval for the Lift as per Lift act should be done by the Lift contractor. 35 Floor Position : Included with LED display and floor annunciator. 36 Special Features: a. Infra red door sensor - full height screen b. Full width half height rear panel mirror c. S.S. hair finish hand rail in car d. Stainless steel signal features e. Vandal proof SS button with SS cover f. S.S. hairline finish door frames for landing doors
g. V3F door operator h. Call register signal i. Stainless steel facio plates for car operating panel and landing fixtures j. Steel ladder for Lift machine room in lift pit. k. On / Off switch for fan and light l. Over-load warning indicator with audio Announcer m. Voltage stabilizer for control circuit. 37 Over Speed Governor, Phase failure and Phase reversal Relay, alarm bell, T guide brackets for car and counterweight, Rubber padding under the winding unit, Motor of adequate capacity, Electromagnetic brake with compression springs, Car safety gears, Buffers, Electro mechanical locks, Emergency key, side supporting angles, Motor over - load protection devices, Final limit switch main, suspension ropes, Counter weights, Lifting joist for mounting the Machineries. 38. Guarantee : Guarantee at least for one year for the materials and workmanship of equipments should be offered by the Lift contractor. 39. Site testing in accordance with IS 14665 should be carried out at the time of Handing over to the User department. 40. Supply, operation and maintenance manual and necessary tools for operation and a set of spare parts required for one year to be provided. SR M-2373
Karhirvel Electrical works (BID ID -1537647)
KKP ELECTRICALS (BID ID -1537619)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_751494.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.57 MB
BOQ_751494.xls
BOQ • 0.36 MB
MCHAtturAllconditions.pdf
Tender Documents • 0.70 MB
Download all tender documents and submit your bid