SE VGTPS
VGTPS, Ramanathapuram
VGTPS PHASE I ELECTRICAL Routine, periodical and breakdown maintenance contract works of Gas turbine, Steam turbo generator, Heat recovery steam generator, other auxiliaries and related system equipment for the period from 01.10.2021 to 31.03.2022
2021_EB_210127_1
SE/VGTPS/RMD/WC.NO.34/2021-22
Open Tender
Miscellaneous Works
Works
30 days
SE VGTPS
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹64,600
Yes
24 Sept 2021
9 Sept 2021
24 Sept 2021
9 Sept 2021
23 Sept 2021
9 Sept 2021
Amount
Control and Instruments
Calibration of pressure, temperature and level gauges
Calibration of pressure, temperature, level and flow transmitters and switches, pH, conductivity transmitters, RTD, Thermocouples, ON/OFF Solenoid valves
Calibration of pneumatic control valves operated by I/P positioners, smart positioners and Hydraulic valves operated by I/H converters and LVDTs, Calibration of CEMS analyzer
Daily Walk down and visual inspection of field instruments
Cleaning and terminal tightness checking of Pressure/temperature/flow/level Transmitters, switches, signal conditioners & sensors, Junction Boxes, On/Off valve Actuators, impulse line flushing and leak attending work
Cleaning, terminal tightness checking and leakage arresting of Pressure/Temperature gauges Thermocouples, RTD, SOV and Limit switches, SWAS & CEMS equipment.
Control valve positioner / air filter regulator / airlock relay / Volume booster etc. cleaning and leak attending work
GT Mark V, STG, BOP, GBC Pro control P13 DCS, DM Plant GE Fanuc PLC modules cleaning and terminal tightness checking work
Other PLC in IA/PA, N2 system, APU, Air Intake, DM Plant, Pretreatment Plant, Bentley Nevada module / panel cleaning & terminal tightness checking work
GT, STG, DM plant OWS & Server system cleaning work
GTG & STG Startup activities
Replacement/Releasing and re-fixing of pressure/temperature/flow/level transmitters & switches and other field instruments etc. for defect and mechanical co-ordination work
Replacement/Releasing and re-fixing of field instruments such as gauges, RTD, Thermocouple, manifolds, needle valve, PU tubes, indicators and impulse line except turbine area
Replacement/Releasing and re-fixing of ON/OFF valves/Actuators, Limit switches, Pilot actuators, Air regulators, O-ring and gaskets etc. for defect and mechanical co-ordination
Replacement/Releasing and re-fixing of Pneumatic control valve's positioner, position transmitter, airlock relay, volume booster, limit switches, vibration sensors, speed sensors, thermocouples/RTDs and special type of instruments in Gas and steam turbine area for defect and other Mechanical co-ordination work
Assistantship in DCS control loop checking of signals and cable healthiness checking, spare cable tracing etc. and Electrical co-ordination work
Replacement/healthiness checking of ABB Pro control P13 DCS/Mark V, GE Fanuc PLC modules & other PLC cards
Functional checking of pressure/ temperature transmitters/switches /RTD/ Thermocouple/flame scanner, Transducers, and operational checking of limit switches, Pneumatic control valves etc. with DCS
Assistantship in check measurement of new materials
Meter Relay Testing
Calibration of voltmeter / Ammeters /Timers includes safe release of meter/timer from panel / testing of meter & meter and physical verification, cleaning attending minor defects, repairs /adjustments, refixing of meter/timer, checking for correctness and restoring normalizing , handling of testing kits / equipments and maintaining of registers etc, as directed by the engineer in charge
Calibration of KW/KVAR/PF/KWh/ Trivector Meter and all transducers including safe release of meter/transducer from panel/testing and physical verification, cleaning attending minor defects, repair/adjustment, refixing, checking for correctness and restoring normalizing, handling of testing kits/equipment and maintaining of registers etc, as directed by the engineer in charge
Calibration of Bimetallic relays Electromagnetic relays and static relays including safe release of relay from panel/testing relay and physical verification, cleaning attending minor defects, repair/adjustment, refixing, checking for correctness and restoring normalizing, handling of testing kits/equipment and maintaining of registers etc, as directed by the engineer in charge
Testing of Numerical relays, CT,PT,CVT,Surge Arrester/Capacitors (HV/EHV) including safe release of relay from panel/testing of relay and physical verification, cleaning attending minor defects, repairs/adjustments, refixing of relay, checking for correctness and restoring normalizing, handling of testing kits/equipments and maintaining of registers etc, as directed by the engineer in charge
Testing of AVR, Generators, Power transformers , 110KV and 11KV Circuit Breakers handling of testing kits/equipments and maintaining of registers, etc, as directed by the engineer in charge
Testing and Troubleshooting of breakers upto 6.6KV rating, lighting transformers, HT and LT Motors, handling of testing/equipments and maintaining of registers etc, as directed by engineer in charge
Lubricating cleaning, checking of control circuits tightness and healthiness in both end (local and module end), Disconnection and Reconnection of Control cables on Motorized valve/Smart Mov's and maintaining of registers etc, as directed by engineer in charge
Limit setting of torque and limit switch of motorized valve/Smart Mov's checking of control circuits and maintaining of registers etc, as directed by engineer in charge
Troubleshooting of control circuits problems in all type of LT & HT modules, Checking for tightness healthiness cleaning of all type of control and relay panels, UPS, Chargers, LT & HT module, control and annunciation panels, fire panels, fire detectors and CO2 fire protection etc, and maintaining of registers etc, as directed by engineer in charge
Troubleshooting and cleaning of SCADA, Routine maintenance of CCTV, Intercom, PA System , Bio metric and LAN
Assistance to the maintenance Engineers during GTG & STG startup and shutdown, commissioning of new equipment & other activities as directed by engineer in charge
Monitoring, taking daily walk down check list of all important parameters in the station, checking of all fire systems and checking of all intercom connection healthiness
Electrical Maintenance -I
Maintenance of modules below 45 kW rating (once in 3 months) & breakdown works.
Maintenance of LT Modules 45 kW &above rating regular (once 3 months) & breakdown
Maintenance of LT Breakers, 45 kW &above rating regular (once in 3 months) & breakdown
Maintenance of LT motors 25 HP/18.5 kW and rating regular (once in 3 months) & breakdown works
Maintenance of LT motors 25 HP/18.5 kW and above regular (once in 3 months) & breakdown works
Maintenance of HT motors, regular (once in 3 months) & breakdown
Maintenance of HT circuit breakers, regular (once in 3 months) & breakdown works
Maintenance of carbon brushes GTG excitation, regular (once in a month) and breakdown
Monitoring taking daily walk down check list of all important equipments
Replacement of worn-out bearing of LT Motors below 18.5 KW
Replacement of worn-out bearing of LT motors above 18.5 kW to 45 kW
Replacement of worn-out bearing of LT motors above 45 kW to 150 kW
Co-ordination work with MRT for testing of Generators and HT motors includes Disconnection and Reconnection of Links to isolate the equipments
Vertical Motors Releasing and Refixing due to Unexpected motor winding burnout and Mechanical Co-ordination work
100HP, 75KW, ACC Fan Motors Releasing, unloading, loading and Refixing due to unexpected motor winding burnout and breakdown work.
Electrical Maintenance -II
Rectification of indoor and out door lighting such as tube light fittings, SV and MV lamp fittings etc., Below 4.5mtrs height
Rectification of indoor and out door lighting such as tube light fittings, SV and MV lamp fittings etc., Above 4.5mtrs height
Maintenance of Feeder Equipment (110KV SF6 Breaker, 110KV Isolators with earth, CT’s, CVT’s, and LAS) in switch yard once in 2 months
Maintenance of GTG/STG Transformers and Auxiliary Transformers like UAT’s, APT’s, Rectifier Transformer and Lighting Transformers once in 2 months
Maintenance of Battery cell and once in a week
Extension of temporary supply
Painting of Electrical motors upto 25 HP motor
Painting of Electrical motors above 25 H.P to 200 HP, MOM Box sets, CT sets and PT sets at 110KV switch yard ,& local panel board box
Monitoring taking daily walk down check list for all important Equipments
Pre checks and Assistance During GTG and STG Startup.
Co-ordination work with MRT for testing of Transformers & 110 KV Circuit Breakers
operation
Phase-I Main Control Room: – Carrying out assistance operation works in taking periodical readings, Battery and Battery charger readings and in operating manual valves / breakers etc., and also in startup and shutdown activities of unit etc
Phase-I Switch yard control room:- Carrying out assistance operation works in taking periodical reading and also assisting the operator in operating isolators manual operation , battery and battery charger readings etc., and also assist during LC works etc
Gas Booster Compressor #1 Area:-Carrying out assistance operation works in taking periodical reading and in local operation of the pneumatic & manual valves and also in startup and shutdown activities etc.,
SARAVANASAKTHI ENGENIUSS
STK TRANSFORMERS
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .