Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹11.9 CrAdmitted-Finance VILL KAKDWIP SUBHASH NAGAR P O KAKDWIP DIST SOUTH 24 PARGANAS PIN 743347 | KAKDWIP | SOUTH 24 PARGANAS | WEST BENGAL | 743347 | -0.18% | ₹11.9 Cr | L1 | Admitted-Finance |
Tender Value
₹11.9 Cr
EMD Value
₹10 L
Closing Date
4 Apr 2026, 1:00 pmClosed
DIRECTOR GENERAL (PLANNING_DEVELOPMENT)
19, NELLIE SENGUPTA SARANI, KOLKATA 700 087
Construction of Semi Underground Reservoir cum Booster Pumping Station at Mandir Para Uttaran (opposite to Avishikta-I) beside E.M. Bypass in Ward No. -106, BR-XII.
2026_KMC_1016860_1
KMC/P_D/102/2025-26/R1 (2nd Call)
Open Tender
CIVIL WORKS
Percentage
730 days
Mandir Para Uttaran
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹10 L
23 Jun 2026
28 Feb 2026
6 Apr 2026
1 Mar 2026
4 Apr 2026
2 Mar 2026
Providing Bored Cast-in-situ M25 grade R.C.C. pile in position as per specifications in all kinds of soil including cost of boring using drilling mud to stabilize the bore and flushing the bore of excess mud with freshly prepared drilling fluid by using pumps prior to placing concrete by tremie pipe in one continuous operation and including the cost of all materials and labour for placing of concrete and also including the cost of mobilization and hire charges of all equipment necessary for boring, welding of reinforcement cage as necessary and lowering of reinforcement cage, preparation and placing of concrete, including the cost of concrete but excluding the cost of reinforcement and labour for bending binding etc. complete as per Drawing and Technical Specifications and removal of excavated earth with all lifts and lead upto 1000 m. Work to be executed as per IS: 2911 (Part II Sec 2).(b) Using tripod, winches, ii) Pile diameter - 500 mm.
Removal of mud/sludge/slurry/liquid earth obtained during piling work from the working site and disposal of the same beyond the KMC/Municipal or any suitable area with conformity of Municipal Corporation Rules using tanker including loading and unloading the same with pump, clearing the site complete in all respect as per direction of the Engineer-in-charge.(b) For 450mm Pile
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm.
(b) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring.
(c) Depth of excavation for additional depth beyond3000 mm. upto 4000mm. excluding cost of shoring asnecessary.
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.For SUGR and Toilet Block
Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor (A) [Pakur Variety] (a) 1:3:6 proportionFor SUGR and Toilet Block
A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity
Supplying ready mixed concrete of M 25 Grade with well graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu.m of wet concrete produced in computerised batching plant under controlled condition using approved super plastisizer, designing concrete mix following I.S. 10262 and I.S. 456, transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required levels of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification & direction of the Engineer-in-charge including computerised batching plant transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. [cement to be supplied by the Manufacturer/ supplier] In Ground Floor and Foundation (i) With approved concrete pump For pile
Supplying ready mixed concrete of M 30 Grade with well graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu.m of wet concrete produced in computerised batching plant under controlled condition using approved super plastisizer, designing concrete mix following I.S. 10262 and I.S. 456, transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required levels of concreting and then placing the mix in its final location of form work, compacting and curing the same complete as per specification & direction of the Engineer-in-charge including computerised batching plant transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. [cement to be supplied by the Manufacturer/ supplier] In ground floor and foundation.(ii) With approved concrete pump
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.
Hire and labour charges for shoring with sheet pile (12 mm thick) & ISMB- 250 runner, struts, anchor, tie etc. complete. beam section conforming to IS- 226 IS:808 & SP(6)- 1964 including cutting to requisite length, fabrication with necessary welding conforming to IS: 816-1956 & is: 1995 using electrodes of approved make and brand conforming to IS: 814-1957 including driving and complete removing them as per direction of the Engineer-in- charge for overall depth of excavation from G.L., c) 6.0 M to below
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (When the height of a particular floor is more than 4 m the equivalent floor height shall be taken as 4 m and extra for works beyond the initial 4 m ht. shall be allowed under 12 (e) for every 4 m or part thereof) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work Wal
Application of Two Coats of Epoxy Primer as per BS 5493 by brush on the cleaned dry concrete surface with epoxy resin primer with reactive suitable hardner mixture as per specification and direction of EIC all complete.
Coating of "Food Gr. Epoxy" resin of thickness not less than 240 micron with a low viscosity, crystallisation- resintent food grade epoxy resin base with a reactive diluents combined with high build epoxy amine adducts as per BS 5493 standard and a poly amide or amido poly amine or any other suitable hardener. it shall react with epoxy resin at normal ambient temperature, suitable for solvent -free coatings as per recommended proportion for use on metal, concrete and wood surface to protect from corrosion, give anti-fungal properties, as per guideline of FTA and USDA as well as damaged from chemical reaction after making the surface free from dust, oil and moisture etc. all complete as per instruction and to be satisfaction of EIC. [Thisitem will be operated on priorb permission from the concerned SE/ Dy.Chief Engineer]
Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer's specification for water proofing layer in water tank etc. (No Departmental Cement is required) Under screed concrete, over floor = [(122.00x8.00)] sq.m.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes. Pakur variety For screed concrete
Brick work with 1st class bricks in cement mortar (1:4) (a) In foundation and plinth Pump House Room
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar (b) 20 mm thick plaster
thick plaster Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar (b) 20 mm thick plaster (ii) With 1:4 cement mortar (c) 10 mm thick
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar (b) 20 mm thick plaster Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor: (b) Two Coats
Protective and Decorative Textured exterior high class matt finish paint of approved quality, composed of special Tharmoplastic Resin containing fine crystalline additives derive from Granite as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor Two Coat
(b) Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand(1.5mm thick)
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.In ground floor.
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.In ground floor.
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (a) One Coat i) Water based interior grade Acrylic Primer
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) i) Water based interior grade Acrylic Primerii) Luxury Quality
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. (This item is applicable to new work or old work when the original surface has been exposed by removal of old paint.) SUGR and Pump House area LS 100 sq.m.
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface : With other than hi-gloss of approved quality (iv) Two coats (with any shade except white)
Priming one coat on timber or plastered surface with synthetic oibound primer of approved quality including smoothening surfaces by sand papering etc. (This item is applicable to new work or old work when the original surface has been exposed by removal of old paint.)
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (a) On timber or plastered surface : With other than hi-gloss of approved quality (iv) Two coats (with any shade except white)
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. In ground floor.
(a) Supplying, fitting and fixing steel rolling shutter profile type with 18 B.G . of approved type steel latche section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete.
M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. I) For structural members of specified sections weighing less than 22.5 Kg./m
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal /Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
Supplying, fitting and fixing Marble Slab/tile of 15 to 18 mm thickness in floor, lobby, stair, landing & treads etc. over 20 mm (av.) thck base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/Sq.m before placing marble & jointed with white cement slurry @ 2.0 kg/Sq.m with necessary pigments including grinding and Granite polishing as per direction of Engineering -in -Charge in Ground Floor. {White cement and Pigment to be supplied by the Agency](b) With Chawk Dungri(iii) Area of each tile exceeding 0.6 sq.m but not excedding 1 sq.m.
Supplying, fitting, fixing marble slab/tiles, 15 mm. to 18 mm. thick in dado / wall in 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks applying white cement slurry @ 4.4 kg/ sq.m at the back side of marble & pointing in cement mortar (1:2) (1 cement, 2 marble dust) with admixture of pigment matching the stone shades including polishing all complete as per direction of the Engineer-in-charge including cost of materials,labours, scaffolding, staging, curingcomplete. [White cement, Pigment to be supplied by the Agency]
20 mm. thick (finished) terrazo work with precast tiles set on 20 mm avg thick cement mortar (1:3) and sides with admixture of pigment and white/grey cement as necessary in floor, dado, skirting, staircase etc. laid in panels or in patterns including high polishing, raking out joints, roughening of concrete surface & application of cement slurry before flooring works using cement @ 1.75 kg. per sq.m. all complete including all materials & labour. ( Add extra @ 1.5 % for each additional floor upto 4th floor and @ 1.75 % for each additional floor above 4th floor). In ground floor.(B) 12 mm. thick terrazo topping, laying and finished to 9 mm. thick after final grinding with 0 to 10 mm. size mosaic chips.(v) In pink, green, yellow, light green colour using white cement only and necessary pigment.
Supplying & laying as per IRC-SP:063-2004 paver unit of any shade of approved quality as per relevant IS code, laid in pattern as directed in pavement, footpath, driveway (paver block only), etc including necessary underlay complete in all respect with all labour and material. [Border concrete if necessary to be paid separately]. Note: Sub-grade CBR should not be less than 5. (c) 60 mm thick interlocking designer concrete paver block M- 35 grade for light-traffic zone,commercial & office complex,tourist resort as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular /granular sub-base course including cost of sand for sand bed but excluding cost of base ,sub-base course & subgrade preparation.) (ii) Coloured Decorative
Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mafinish, complete as per direction of the Engineer-in-charge. Weight of Strainless Steel railing per metre 6.5 Kg (approx)
M.S PLATE AS PER IS : 2062 -2011/Latest Revision, Make : SAIL/ TATA/JINDAL 10-12mm
Fabricating M.S.Pipes of different diameter in shop out of 8 mm to12 mm thick M.S. plates supplied departmentally, cutting the plates to exact size & shape by gas cutting device and/or by adopting any other approved type of mechanical means bending the same in true curvature by template and rolling machine of approved design including proper marking leveling joints followed by electric arc welding as per relevant I.S. specification - longitudinal and circumferential, as necessary. Using standard electrodes including edge preparation, electricity charges and Hydraulic Testing of fabricated piece all complete as per specification and direction of engineer-in-charge. (Engineer-in-charge shall approve the electrodes for arc welding before use.)
Supply of E.R.W.M.S. (Electrical Resistant Welded M.S.) black pipe of ISI Mark as per relevent IS Specification (heavy quality) having wall thickness not less than 5 mm [N.B. The rates of supply of TATA Make pipe will be arrived at by adding 20% of the corresponding rates]
for Delivery pipe connection from pump to manifold and bypass connection to Inlet main (upto Boundary Wall) -(4.3x4)+(6.5x4)+(12.5x4) = 93.20 (for Level Indicator and Hypo Dosing system installation) = 8 M Total 101.20 M
Supply of E.R.W.M.S. (Electrical Resistant Welded M.S.) black pipe of ISI Mark as per relevent IS Specification (heavy quality) having wall thickness not less than 8 mm [N.B. The rates of supply of TATA Make pipe will be arrived at by adding 20% of the corresponding rates]for Distribution pipeline
Supply of M.S. Flange (Slipper type) as per IS-6392 Table 17 thickness 20mm - 22mm 150 mm
Supply of M.S. Flange (Slipper type) as per IS-6392 Table 17 thickness 20mm - 22mm 200 mm
Supply of M.S. Flange (Slipper type) as per IS-6392 Table 17 thickness 20mm - 22mm 300 mm
M.S. Blank flange as per IS-6392 Table 20 for 50 mm to size & for 200mm & above as IS -6329 Table-14) thickness 20mm-22mm NB diameter in mm 150
Flange Joint to CI./DI/MS. pipes and specials including supply of rubber gasket. nuts. bolts. washers etc. of best quality to make the joint watertight at required hydraulic pressure all complete as per specification & direction of the Eengineer-in-charge. diameter in mm 150mm dia.
Flange Joint to CI./DI/MS. pipes and specials including supply of rubber gasket. nuts. bolts. washers etc. of best quality to make the joint watertight at required hydraulic pressure all complete as per specification & direction of the Eengineer-in-charge. diameter in mm 200mm dia.
Flange Joint to CI./DI/MS. pipes and specials including supply of rubber gasket. nuts. bolts. washers etc. of best quality to make the joint watertight at required hydraulic pressure all complete as per specification & direction of the Eengineer-in-charge. diameter in mm 300mm dia.
Flange Joint to CI./DI/MS. pipes and specials including supply of rubber gasket. nuts. bolts. washers etc. of best quality to make the joint watertight at required hydraulic pressure all complete as per specification & direction of the Eengineer-in-charge. diameter in mm 450mm dia.
Supplying and fabricating 20 mm to 32 mm thick (finished thickness) M.S. Blank Flange properly ribbed, one face machined including drilling holes as per standard table, fitting and fixing the same with M.S. flanged pipe with supply of nuts, bolts, washers, gasket etc. of best quality all complete as per specification and direction of the Engineer in charge.450 mm dia.
Supplying and fabricating 20 mm to 32 mm thick (finished thickness) M.S.flange, properly ribbed one face machined, including drilling holes as per standard table, fitting and fixing the same with M.S.pipe by electric arc welding as per relevant I.S. specification using standard electrodes and direction of the Engineer in charge. [The Engineer-in-Charge shall approve the electrodes for arc welding before use.] 450 mm dia.
Supply of E.R.W.M.S. (Electrical Resistant Welded M.S.) black pipe of ISI Mark as per relevent IS Specification (heavy quality) having wall thickness not less than 5 mm [N.B. The rates of supply of TATA Make pipe will be arrived at by adding 20% of the corresponding rates]
Cast Iron double flanged single door swing non-return valve generally conforming to IS 14846 having body, door cover in graded cast iron to IS 210 gr. FG 200, body and door rings and bearing block of leaded tin bronze to IS 318 GR. LTB 2, hinge pin of ST AISI410 valves suitable for maximum working pressure of 10 kg/cm... and body tested 15 kg/cm diameter in mm 150
(internal)Ductile Iron double flanged manually operated sluice valve generally conforming to IS 14846:2000, having body, door, dome, gland in graded ductile iron to IS: 1865, four faces and spindle nut of gunmetal to IS: 318, inside screw non-rising stainless steel AISI 410 spindle valves suitable for maximum working pressure of 10 kg/cm2 and body tested to 15 kg/cm2 flanges flat faced and drilled to IS: 1538-1993. Valves tested by closed end method only. 350mm and above valves are complete with enclosed 150 mm dia
300 mm dia. (internal)Ductile Iron double flanged manually operated sluice valve generally conforming to IS 14846:2000, having body, door, dome, gland in graded ductile iron to IS: 1865, four faces and spindle nut of gunmetal to IS: 318, inside screw non-rising stainless steel AISI 410 spindle valves suitable for maximum working pressure of 10 kg/cm2 and body tested to 15 kg/cm2 flanges flat faced and drilled to IS: 1538-1993. Valves tested by closed end method only. 350mm and above valves are complete with enclosed 300 mm dia
450 mm dia. (internal)Ductile Iron double flanged manually operated sluice valve generally conforming to IS 14846:2000, having body, door, dome, gland in graded ductile iron to IS: 1865, four faces and spindle nut of gunmetal to IS: 318, inside screw non-rising stainless steel AISI 410 spindle valves suitable for maximum working pressure of 10 kg/cm2 and body tested to 15 kg/cm2 flanges flat faced and drilled to IS: 1538-1993. Valves tested by closed end method only. 350mm and above valves are complete with enclosed 450 mm dia.
Double flanged double eccentric design manually operated cast iron butterfly valve having body disc, and end cover in graded cast iron to IS : 210, synthetic rubber face ring secured on disc by a SS/AISI 304 retaining ring with stainless steel screws the rubbering sitting on a corresponding integral monel 60 seat in body stub shaft of AISI 431 riding in TEFLON lined bearing, valves suitable for maximum working pressure of 10/16 kg/cm2 and body tested 15/24 kg/cm2. Flanges drilled to I.S 1538 TABLE 4 & 6.300 mm dia.
Gas cutting of M.S. pipes and/or M.S. plates of different thickness all complete as per specification and direction of the Engineer-in-Charge. Thickness in mm 5 mm to 8 mm thick plate
Field welding of M.S. plate by means of electric arc welding as per relevent IS specification using standard electrodes including edge preparation and charges of deployment of electric generator set with fuel, lubricant and all other tools and plants all complete as per specification and direction of Engineer-in-Charge.[Engineer-in- Charge shall approve the electrodes for arc welding before use] Throat thickness in mm 5mm to 6mm
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992
Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin-charge. (Payment will be made on centre line measurement of the total pipeline including specials. (B) Under ground (iii) 160 mm dia.
Solid flush type doors of deluxe decorative (both side) quality, conforming to I:S 2202 timber frame consisting of top and bottom rail and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 27.5mm wide battens places both ways in order to made the door of solid core and internal lipping with teak, mahogony or rose wood approved decorative veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing the shutters in position but excluding the cost of hinges and other fittings in ground floor: (a) 35mm thick shutters (single leaf)
Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987.(B) coloured, toughened glass conforming to IS: 2553- 1992 (part-II) (i) 6mm thick
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(ii) Grill weighing above 16 Kg./sq.mtr and above (CONSIDER 18KG PER SQ.M.)(a) In ground floor
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals).
Ductile iron Single Chamber type air release valve having small orifice elasticball resting on gunmetal orifice nipple large orifice vulcanite ball seating on moduled seatring,valve with built-in-Kinetic features, isolating sluice valve mounted in horizontal position and operated by a metre wheel gearing :inlet faced and drilled to IS1538Table4&6. valvesuitable for maximum working pressure of 10 kg/CM2.Diameter in mm - 100
Supplying, fitting and fixing in position reinforced cement polymer concrete manhole/ gully pit cover with matching frame.As per I.S-12592(M.D) (i) 35 MT load bearing capacity round manhole cover provided with two lifter hooks fitted with matching frame of size each 4034.00 Cover: 700 mm X 100 mm Frame: 910 mm X 185 mm opening: 560mm Weight: 245 kg (approx)
(a) Supplying, fitting galvanised 3 ply 12 gauge / 4 points line of barbed wire in fencing (holes already made in the body of the post) or fixed by staples tightening and fixing the wires in taut condition with straining bolts including the cost of cutting and of lapping joints in the wire as necessary but excluding the cost of galvanised staples, straining bolt and binding wire where necessary. (Payment to be made on the length of individual lines of wire.)
Supplying fitting and fixing P.V.C. door shutter of approved quality & shade in position, the style & rail of the P.V.C. door shutter will be made of rigid P.V.C. multicavity hollow chamber of suitable size and section with 2.0 mm (+/-0.2 mm) wall thickness, the section will have 2nos. built in beads, horizontal & vertical section shall be fixed to each other by self tapping screws and 2 nos. of solid plastic or M.S. tubular galvanised brackets of length 200mmx80mm and other100mmx100mm both 1.20 mm in each corner of the shutter frame for placing hinges. Polymer based multicavity hollow section of 105 mm x37mm with 2.0 mm (+/- 0.2 mm) wall thickness will be fitted in the middle as lock rail reinforced by solid polymer bar of 200 mm long at both ends abd screws from both sides. The section frame will then be fitted in by PVC panels of size 100 mmx20 mm with wall thickness of 1.2 mm (+/- 0.2 mm) and 2 nos. of 6 mm dia and screws from both sides 6mm dia bright rod will be inserted horizontally with both side check and nut system and stretches where fixing of hinges / hasp bolt / tower bolt / door ring are required to be strong enough to with stand wear and tear. The rate is inclusive of cost of all materials, labour, and hire of tools and plants and appliencies. Carriage of all materials taxes and all other incidental charges complete.The rate is exclusive of cost of hinges, hasp bolt, tower bolt,door ring etc. In ground floor.
Supplying, fitting & fixing factory made foam PVC (density shall not be less than 600 kg/cum) door frame (finished weight of 2.73 kg/mtr.) of size 100mm X 45mm made off with 5mm thick extruded foam PVC sheet, mitre cut at junction of horizontal and vertical member and joined them by heat welding. Entire door frame profiles to be reinforced with steel primer coated 19 SWG 40mm X 20mm M.S. tube. An additional 5mm thick PVC sheet with desired colour/shade to be provided at the exposed surface and three nos 5mm thick PVC sheet to be provided as gap insert. The door frame to be fixed with wall by using 8mm dia. and 100mm long strainless steel screws and PVC fasteners. A minimum of 4 nos. screws to be provided for each vertical member & 2 nos. for horizontal member all complete as per direction of Engineer-in-Charge
Performing High Strain Dynamic Pile Load testing by using Pile Driving Analyzer as per IRC: 78-2014 standard procedure with a hammer of suitable weight (1-2% of the test load or 5-7% of the dead load on the pile or suitable energy as decided by Engineer-in charge). The rate is inclusive of construction of suitable platform, fixing of strain sensor & accelerometer, charges for hammer hoisting arrangement & removing etc. The rate is also inclusive of cost & carriage of all materials, completion of field test, CAPWAP analysis & submission of test results along with reports as per direction of Engineer-in-charge.b) For Test load 101 to 300 MT (i) Within 60 km from Rajbhaban
Supplying, fitting and fixing bib cock or stop cock.a) i) Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand).
b) i) Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)For Exposed Work PVC Pipes 20 mm
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)For Exposed Work PVC Pipes 32 mm
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer1000 litre capacity
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. 550 mm X 400 mm size
Supplying, fitting and fixing with cement jointing (3:1) salt glazed stoneware pipe including excavation of earth upto 1.50 metre depth in all sorts of soil both mixed or unmixed and refilling (but excluding concreting at bottom and sides). 300 mm
Supplying, fitting and fixing yard gully with approved H.C.I. grating complete. 225 mm X 150 mm with 230 mm gratings
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (ii) Double Socketed 3 Meter Length (b) 110 mm
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (ii) Double Socketed 3 Meter Length (b) 110 mm
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (ii) Double Socketed 3 Meter Length (iv) Double Socketed 1.8 Meter Length
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (ii) Double Socketed 3 Meter Length xii) Door Bend (LH) & (RH) (b) 110 mm
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (ii) Double Socketed 3 Meter Length xi) Door Bend (T.S.) (c) 160 mm
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (ii) Double Socketed 3 Meter Length xxi) 110 X 110 P Trap
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (ii) Double Socketed 3 Meter Length xii) Door Bend (LH) & (RH) (b) 110 mm
Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin-charge. (Payment will be made on centre line measurement of the total pipeline including specials.
Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin-charge. (Payment will be made on centre line measurement of the total pipeline including specials. (iii) 160 mm dia
Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. (a) With 'P' trap
Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete.(ii) 470 mm X 280 mm X 340 mm
Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete. (a) E.W.C (iv) Bestolite (solid type) white
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials.i) With Pakur variety. (SAIL/TATA/RINL)
M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge
M.S. works in brackets made from flats, angles, tees etc. to sizes specialy bent, twisted, forged; making holes drilled and fitted to rafter of trusses with necessary bolts, nuts, washer or screws etc. (length of straight not less than 230 mm)
Supplying, fitting and fixing in position G.I. pipes of TATA make for underground works with all necessary accessories,specials viz.socket, bend, tee, union, cross, elbow, nipple, short piece etc.including cost of all materials,jointing materials ,cutting pipes,making threads,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed with two coats of painting on G.I. pipes and specials with bituminous paint complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.Payment for painting will be made seperately) (i) 15 mm dia. medium quality
Supplying, fitting and fixing in position G.I. pipes of TATA make for underground works with all necessary accessories,specials viz.socket, bend, tee, union, cross, elbow, nipple, short piece etc.including cost of all materials,jointing materials ,cutting pipes,making threads,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed with two coats of painting on G.I. pipes and specials with bituminous paint complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.Payment for painting will be made seperately) Installation & commissioning of Pressure Gauge
Supply and fitting & fixing different factory made metal craft sheet (Excluding cost of metal crafting) including cost of powder coating for (M.S Aluminium plate) and finished metal sheet with all fitting accessories complete in all respect As per direction of EIC, cost of powder coating Mild steel plate i) 2mm thick (for Level Indicator and Hypo Dosing system installation)
Welding in Structural works with Gas or Electric. a) Tack welding
Welding in Structural works with Gas or Electric.(for Level Indicator and Hypo Dosing system installation)
Supplying, fitting and fixing 4mm. Thick acrylic sheet including providing holes of knobs and key as per existing shutter and chamfering the edge of the acrylic sheet.(for Level Indicator and Hypo Dosing system installation). 6.7m x0.6m = 4.02 Sq.m
Supplying and fitting fixing in position 15 cm Dia. C.I. Pully (extra payment will be made for pully bar and other allied item in respective item). (for Level Indicator and Hypo Dosing system installation).
Supplying 7 ply galvanised strand wire 19 gauge fitted and fixed complete with necessary eyes, hooks and straining bolts (excluding the cost of straining bolts.) (for Level Indicator and Hypo Dosing system installation)
Supplying and Delivery CFL Luminaries (Havells make HRC4185099) Outdoor type. (for Level Indicator and Hypo Dosing system installation).
Pendent Holder.(for Level Indicator and Hypo Dosing system installation)
MCB Enclosure 4-Way.(for Level Indicator and Hypo Dosing system installation)
2.5 Sq.MM "FR" Standerd Copper Wire.(for Level Indicator and Hypo Dosing system installation)
SCHEDULE OF RATES FOR FIXING OF(approved MATERIALS (Main Switches, Fittings, Fans etc.) (All materials, except equipments to be fixed up, are to be supplied by the contractor)Fixing only Sheet Steel Main Switch (Rewirwable type)/ Change over on Flat IronFrame/Angle Iron Frame on wall 415TP/TPN 32/400 Amps On angle iron frame
Compression Glands.Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring FOR dust & moisture(proof entry of XLPE/PVC armoured cables as below: FOR 3... core upto 400 sqmm
SUPPLYING OF 1.1 KV. Grade PVC insulated armoured Aluminium Conductor of fllowing Cables (Make- Polycab/Gloster/Havells/Finolex) sq.mm No& dia. Of wire in mm No of Core 61/3.00/3.400 sqmm
Laying through Underground Trech.(c)Laying of one No. cable above 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
SUPPLYING AND FIXING SHEET STEEL (16SWG) CABLE END BOX ON TPN SFU ENCLOSURE WITH NUTS BOLTS ETC INCL. POWDER COATED PAINTING. 415A
SUPPLYING AND FIXING SHEET STEEL (16SWG) CABLE END BOX ON TPN SFU ENCLOSURE WITH NUTS BOLTS ETC INCL. POWDER COATED PAINTING. 200/250A
Compression Glands.Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring FOR dust & moisture(proof entry of XLPE/PVC armoured cables as below: FOR 3... core upto 240 sqmm
Concealed Wiring With PVC Insulated and Sheathed Wires in Polythene Pipes - Laying & Fixing Polythene Pipe, MS Boxes, Switches etc. Supplying and fixing polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction)(e) 40mm dia 3mm thick Polythene Pipe
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. angel iron frame 200A Siemens
SCHEDULE OF RATES FOR EARTHING INSTALLATIONS.Earthing Installation by GI pipe ... (FOR Sub(station Neutral/Equipment earthing).Earthing with 65 mm dia GI pipe (TATA(Medium)x 3.0 Mts. long and 1 No. 50 mm x 6 mm galvanized (HOT Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 65 mm dia GI pipe (ISI Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts
SUPPLYING OF 1.1 KV. Grade PVC insulated armoured Aluminium Conductor of fllowing Cables (Make- Polycab/Gloster/Havells/Finolex) sq.mm No& dia. Of wire in mm No of Core 61/3.00/3/1/2.70
Laying of one No. cable upto 35 sqmm in underground trench 460mm wide x 760 mmaverage depth, with brick protection on thetop of the cable with 8 (eight) Nos. bricks per metre, includingfilling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Earth busbar Supplying & fixing earth busbar of galvanized (HOT Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Fixing only Voltmeter/Ammeter/Energy meter with screws & other fixing materials incl. making necessary holes and connections
Supply & fixing of 415/440 Volt, HRC fuse (Make: L&T/ Havels/CGL/GE).for 250 Amp Supply and fixing of analog Ammeter ranging 0-100Amps having C.R ratio of 100/5A, 144 mm sq size (make:AE/KAPPA/IMP).
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand(approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 4 x 80/0.4 (10 sqmm)
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. angel iron frame 415A Siemens
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. angel iron frame 200A Siemens
Bus-Bar Chambers : Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required ... ( As per Drawing no. 470 of PWD Specification Book ... May 1991) Dimension ofAl 4 x (2x 80x5) mm. bars[85mm long) Dimension of Sheet 500x150mm Metal Box Rate / Mt.of completechamber 415 V, 1000 A
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire(Brand(approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 3 x 36/0.3 (2.5 sqmm)
Concealed Wiring With PVC Insulated and Sheathed Wires in Polythene Pipes - Laying & Fixing PolythenePipe, MS Boxes, Switches etc.Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand(approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing FOR switch by cutting bakelite/perspex cover and making necessary connections as required
Finishing cable ends.(b)Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.(xxii)3... core 240 sqmm cable
OUTDOOR LIGHTING INSTALLATION, STEEL TUBULAR POLE, M.S. PIPE, G.I. PIPE, POLE CAP ETC SUPPLYING OF SWAGED STEEL TUBULAR POLE AS PER IS 2713, PT. II, 1980 FOR FOLLOWING DESIGNATION AND OF FOLLOWING DIMENSIONS.(OUTSIDE DIA & THICKNESS ARE GIVEN IN ANNEXTURE -1)E) 410 SP - 9 ; 7.5 MTR., 110.00 KG.
SCHEDULE OF RATES FOR OH LINE INSTALLATION (LT DISTRIBUTION).ERECTION OF POLES.ERECTION OF SINGLE STEEL TUBULAR POLE OF LENGTH AS GIVEN BELOW WITH/WITHOUT SOLE PLATE & CAP ETC. IN CC FOUNDATION (PROPORTION AND DIMENSION INDICATED BELOW), HAVING 600X600X150 MM THICK CC (4:2:1) BASE BLOCK BELOW SOLE PLATE/POLE WITH HARD JHAMA METAL INCLUDING CC (6:3:1) MUFFING 0.30 MTS. DIA AND 0.30 MTS. ABOVE GROUND LEVEL INCLUDING 3 MM THICK NEAT CEMENTED FINISH AND GI EARTH BOLT AFTER MAKING DRILLED HOLES ETC. ON POLE & CARRIAGE OF POLE UPTO 1.6 KM FROM STORE TO WORK(SITE INCLUDING FILLING UP THE EXCAVATED EARTH PIT WITH SHIFTED SOIL AND RAMMING PROPERLYUPTO 9.0 MTR. SIZE 0.6X0.6X1.70 MTS
OUTDOOR LIGHTING INSTALLATION, STEEL TUBULAR POLE/ M.S PIPE/ G.I. PIPE, POLE CAP ETC. SUPPLYING & FIXING OF M.S. SOLE PLATE (450X450X6M) AT THE BOTTOM OF POLE.
(H) STREET LIGHTS :3. FIXING OUTDOOR TYPE FLUORESCENT/SV/MV LIGHT FITTING ON POLE INCLUDING S&F 40 MM DIA X 1.68 MTS. LONG GI PIPE (ISI MEDIUM) BRACKET WITH 40 MMX10 MM THICK, MS CLAMP ETC. AND PROVIDING WIRING WITH 2X1/1.40 PVC INSULATED & SHEATHED WIRE (SINGLE CORE) PARTLY IN GI CONDUIT & PARTLY THROUGH ABOVE BRACKET FROM OH LINE TO THE FITTING, WITHOUT CONTROL SWITCH, INCL. MAKING CONNECTIONS AND PAINTING
H) STREET LIGHTS : 5. SUPPLYING & FIXING GI WATERPROOF TYPE LOOPING CABLE BOX SIZE 200X150X100 MM DEEP HAVING 4 MM THICK COMPRISING OF ONE 250 V 15 A KIT-KAT FUSE UNIT, ONE NL ON PORCELAIN INSULATOR, ONE COMPRESSION TYPE BRASS CABLE GLAND FOR UPTO 2- CORE 16 SQMM PVC/A CABLE AND HAVING LINED WITH RUBBER GASKETTED GI TOP COVER WITH BRASS MACHINE SCREWS ETC., EARTHING TERMINAL WITH LUG, ON STEEL TUBULAR POLE NEAR BASE, INCLUDING S&F 40X6 MM THICK, MS CLAMPS WITH BOLTS, NUTS ETC. INCLUDING PAINTING WITH ANTICORROSIVE PAINT
PAINTING OF STEEL TUBULAR POLE OF LENGTHS AND NO. OF COATS OF PAINT, AS GIVEN BELOW WITH READY MIXED PAINT/PRIMER OF(APPROVED MAKE, AND BRAND INCL. PREPARATION OF SURFACE BY SAND PAPER/EMERY PAPER, CLEANING ETC. FOR RECEIVING FRESH COAT OF PAINT.UPTO 9.0 MTR. LONG POLE.(I)1ST COAT OF ALUMINIUM PAINT OVER 1 COAT OF RO PRIMING
PAINTING OF STEEL TUBULAR POLE OF LENGTHS AND NO. OF COATS OF PAINT, AS GIVEN BELOW WITH READY MIXED PAINT/PRIMER OF(APPROVED MAKE, AND BRAND INCL. PREPARATION OF SURFACE BY SAND PAPER/EMERY PAPER, CLEANING ETC. FOR RECEIVING FRESH COAT OF PAINT.UPTO 9.0 MTR. LONG POLE.II2ND COAT OF ALUMINIUM PAINT OVER 1ST COAT
A N N E X U R E - I BASIC RATE OF MATERIALS: (ALL RATES OF MATERIALS FROM K-1 TO K-14 ARE EXCLUDING VAT) 145. GALV. STRAINING SCREW 12"X5/8" DIA
ERECTION OF GALV. (HOT DIP) CROSS ARMS/ `D... IRON CLAMP7).SUPPLYING & ERECTION OF GALV. `D... IRON COMPLETE WITH SUITABLE POLE CLAMP 75MMX88MM PORCELAIN SHACKLE INSULATOR & 15 MM DIA GALV. BOLTS & NUTS. INCL. PAINTING
SUPPLYING AL.CONDUCTOR PVC INSULATED AND SHEATHED UNARMOREDCABLE (1.1KVGRADE, GLOSTER/HAVELLS/POLYCAB). 6SQMM X 2CORE
SUPPLY AND DRAWING OF 7/14 SWG GALVANISED STRANDED WIRE FOR DRAWING UNARMORED CABLE (SUPPLY OF CABLE IS NOT INCLUDED IN THE SCOPE) BY CATENARY SYSTEM OF WIRING WITH 3 NOS REEL INSULATOR PER MTR. AND BINDING WITH BINDING WIRES ETCAS REQD FOR DRAWING.
DRAWING OF UNARMOURED CABLE OF SUITABLE SIZE (SUPPLY OF CABLE IS NOT INCLUDED IN THE SCOPE)ON EXISTING GALVANIZED STRANDED WIRE FOR CENTENARY SYSTEM WITH REEL INSULATORS AND BINDING WIRES.
SUPPLYING AL.CONDUCTOR PVC INSULATED AND SHEATHED UNARMOREDCABLE (1.1KVGRADE, GLOSTER/HAVELLS/POLYCAB). 10SQMM X 2CORE
LAYING THROUGH RCC/HUME/GI PIPE.(A)LAYING ONLY CABLE UPTO 50 SQMM THROUGH EXISTING RCC/HUME/ GI PIPE/OPEN MASONARY TRENCH FOR SINGLE, 2, 3, 3... & 4 CORE
BUILDING WORKS (F) STRUCTURAL STEEL WORKS, GRILLS, GATES ETC. A. ORIGINAL WORKS 1. M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length,fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural members only in finished work as per IS specified weight. Payment for gusset, bracket, cleat, rivets, bolts and nuts may be make by adding the actual weight of such items with the weight of finished structural members or 7% of weight for finished structural members weighing not less than 22.5 Kg. / m. or 15 % of weight for finished structal members weighing less than 22.5 Kg. / m. may be increased allow for bracket, cleat, rivet, bolts and nuts etc. and no seperate payment being made for these items, as per direction of Engineer In Charge. The rates are considered for a height of erection 8m. / 2nd floor level from the ground. Add 1.5% extra over the rate for each additional floor or 4m. beyond initiial 8m. or part thereof. II) For Structural Works in Roof Trusses etc. using joists, channels and angles of specified section weighing less than 22.5 kg/ m
Earthing connection from earth electrode to Trans FORmer Neutral/Earth Busbar.Extra FOR connecting the neutral of Trans FORmer/Earth busbar to earth electrode including S & F 50 mm x 6 mm Galvanized (HOT Dip) steel strip on wall/floor with GI saddles & insulating the same by one layer of PVC strip over one layer of ampere tape
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand(approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC
Finishing cable ends.(b)Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.3... core 70 sqmm cable
A N N E X U R E - I Basic Rate of Materials: (All Rates of materials from K-1 to K-14 are excluding VAT)143. Copper Plate,Copper Strip
Supply, fixing of single phase preventer, L & T make: SPPR-sz5(7wire), 380V
Supplying & Erection of medium size feeder pillar box of Size (1200 x 750 x 450 mm) made up of 2 mm thick MS Plate along with suitable M.S. Angle. The P.B. have double hinge door at the front & back with suitable locking arrangement. The box will be painted by 2 cores of aluminiam paint over 1 coat of red oxide paint. Suitable arrangement should be provided for fixing of Timer unit, fuse unit & other accessories. Leg of the pillar box will be 900 mm in length by made up of (35 x 35 x 3 mm MS Angle with suitable base Plate. Legs of the Pillar box will be erected at 300 mm below the ground level with cement concrete (6:3:1). Rest portion coverd by 5" Brick Wall with plastering & net cement & bottom portion filled with silver sand as drawing & direction of E.I.C
Installation the feeder pillar box only on cement brick foundation including plastering and neat cementing as per specification and direction of E.I.C. b) For medium size feeder pillar box.
ISCHEDULE OF RATES FOR EARTHING INSTALLATIONS.Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (HOT Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:(b)By TATA(Medium GI pipe
Supplying of 1.1 KV. Grade PVC insulated Conductor of following cables (make: Polycab/ Gloster/Havells/):Size in Sq. mm, No & dia. of wire in mm , No of Core - 25 7/2.24 4
Laying through Underground TrechaLaying of two cables upto 35 sqmm in an underground trench in single tier FORmation (Horizontal), the trench size : 680 mm x 760 mm average depth, with brick protection on the top of each cable 8 (eight) Nos. bricks per Mtr. and 4 (f)our) Nos. bricks per Mtr. as separator between the bricks and cables and also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed
200 WATT LED FLOOD LIGHT (KMC STORE ITEM NO:10/57/24).
Supplying of 1.1 KV. Grade PVC insulated Conductor of following cables (make: Polycab/ Gloster/Havells/):Size in Sq. mm, No & dia. of wire in mm , No of Core - 10 1/3.55 4
Laying through Underground Trech.(a)Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand(approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC Average run 6 mtr
S/F fabricating welding fixing G.I.Junction and 1.68m long 40 mm single arm projection bracket made of G.I. pipe (ISI medium) with 2.
Supply and delivery of 1200 mm sweep, 1 phase, 60/70 watt, 5 star and having 300 mm down rod, 1.1mm thick alluminium bled, conforming IS 374, 2mm shank thickness ceilling fan of following make. Orient/Nirmal Make (70 watt):
SSupply and delivery of 230V,50Hz Heavy duty Metal 12"exhuast fan.
Fitter Mechanic.(for Level Indicator and Hypo Dosing system installation) 2nos x 5days = 10nos
Fitter Mechanic.(for Level Indicator and Hypo Dosing system installation) 2nos x 5days = 10nos
Santras (for Level Indicator and Hypo Dosing system installation) 2nos x 2days = 4nos
Mazdoor (Male) (for Level Indicator and Hypo Dosing system installation) 4x5days = 20nos
PROPOSAL OF DY CH. ENG WATER SUPPLY DEPTT DATED-26/12/2024 FOR Supply & delivery of Horizontal centrifugal split case (ISC) type pump of KBL/Wile/KSB/WPII. make with a capacity of 420 m3/hr and 35 mtr. Head, 1470 rpm with a minimum duty point efficiency of 84.5%, having Cast Iron Casing, Bronze impeller, SS shalt & sleeve with delivery and suction size 150 mm and 200mm a respectively coupled with lHorizontal Foot mounted, TEFC, 162 type of CG/ABB/Siemens make motor, having a rating of 55 kW, 4 pole, 415V (±10%), 50142 ( 55%), isulation class F, Nominal speed- 1470 RPM with a minimum quty point efficiency of 92%, minimum pf at duty point 0.8, complete with accessories such as coupling, coupling guard, commen MS Base frame for pump & meter, Foundation bolts, companion flanges etc. and Full Automatic Star Delta Starter of SIEMENS/L&T/BCH make having Carrent rating 2000, Voltage rating 415 V (±10%),0/L, RELAY range 85-100A The Pump should have an impeller dia of 347 mm approx with an NPSHr of 5 mtr approx. The direction of rotation OF Pump looking from DE side "Counter Clock wise", suction pipe location looking from DE side "Left Hand Side PUMP MOTOR COMMON BASEFRAME & MOUNTING BOLTS & GROUTING BOLTS COUPLING COUPLING GUARD COMPANION FLANGES MOTOR STARTER)
SUPPLY AND FIXING OF 2 MM POLYVINYL GLOW SIGN BOARD MADE OF 22 SWG GI SHEET BOX WITH 1...X1... ALUMINUM CHANNEL FOR FIXING THE VINYL BOARD AFTER NECESSARY CUTTING THE LETTER AS REQUIRED & S\F LED TUBE LIGHT FITTINGS ALONG WITH ALL ACCESSORIES
Dismalting all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish As directed within a lead of 75m In ground floor including roof (b) above 150mm thick Breaking of pile top: 310x(3.142x0.5x0.5/4)x2.5
Sub Total
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.46 MB
techbid.pdf
Tender Documents • 1.68 MB
finbid.pdf
Tender Documents • 0.75 MB
BOQ_2498197.xls
BOQ • 0.60 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .