| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.4 LAccepted-AOC 00 A N SINHA ROAD KADAM KUAN PATNA BIHAR 800003 | PATNA | BIHAR | 800003 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹39.9 L+₹4.9 L (14.0%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹40.2 L+₹5.2 L (15.0%)Rejected-Finance LIG 10 VIVEK NAGAR NAVIBAGH BHOPAL MADHYA PRADESH 462038 | BHOPAL | MADHYA PRADESH | 462038 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹40.8 L+₹5.8 L (16.5%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹41.1 L+₹6.1 L (17.3%)Rejected-Finance 19 SAINIK COLONY BAIRAGARH BHOPAL MP 462 030 | BHOPAL | MADHYA PRADESH | 462030 | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹49.9 L
EMD Value
₹99,800
Closing Date
29 Aug 2022, 6:00 pmClosed
GE BHOPAL
GE BHOPAL
DAY TO DAY MAINT OF EM SERVICES REPAIR MAINT CEILING FAN EXHAUST FAN WALL MOUNTED FAN AND MISC WORK REPAIR MAINT OF LT PANELS LT CABLES O H LINES AND ALLIED WORKS AT SI LINE UNDER GE BHOPAL
2022_MES_542990_1
8914/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
BHOPAL
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE BHOPAL
₹99,800
Yes
28 Sept 2022
3 Aug 2022
31 Aug 2022
3 Aug 2022
29 Aug 2022
17 Aug 2022
Amount
NOTES FOR DAY TO DAY MAINT OF E/M SERVICES AT SI LINES: - (i) The works/items given below are for attending day to day complaints (of int. electricfication, fans, geysers, etc) by deploying sufficient skilled trades men/materials and making functional the complaint. (ii) The quoted rate deems to include for all minor expenses required for making the complaint functional. (iii) The trades man shall report to E/M complaint cell SI Line daily at 8.30 am to take complaints from concren JE E/M. The complaint must be attended on same day in stuiplate time period by providing material required and by deploying sufficient manpower by the contractor. The complaint slip duly signed by the user shall be returned back at the complaint cell with proper feed back in the evening. (iv) The tradesman deployed for work shall wear proper uniform with full shirt and full pant with their names & contractors name on the uniform. Colour code of uniform will be decided by Engineer-in-charge. NOTES for Repair/maint of ceiling fan, exhaust fan, wall mounted fan and Misc E/M works: - (i) The quoted rate deems to include for all minor expenses required for making the complaint functional. (ii) Repairing/ rewinding of ceilling fan/ exhaust fan shall be carried out in the AGE E/M SI Line subdivision in present of concern JE E/M. (iii) Space/room will be provided by AGE E/M in the E/M yard for carring out repair work. (iv) Contractor staff will collect defective fans from concern JE E/M, check the fans after opening it, and intimate the defects in the fan to JE E/M before carring out the repairs. (v) The bearing of fan should be of NBC/SKF/FAG make only. No other make will be accepted.
S&F in repairs Switch piano, flush type, single pole, one way, 6 Amps, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed.
S&F in repairs Switch piano, flush type, single pole, two way, 6 Amps, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed.
S&F in repairs Bell push, flush type, 6 Amp piano type, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed.
S&F Switch piano, one way, single pole, 15 Amp, 240 volt, 50Hz, flush type, ISI marked complete all as specified and as directed.
S&F in repairs Socket outlet multipurpose having provision for 2 & 3 pin, 6 Amp flush type, 240 volt AC, ISI marked complete all as specified and as directed.
S&F in repair socket outlet 2 in 1, 3 pin 5 and 15 Amp flush type, 240 volt AC, ISI marked complete all as specified and as directed.
S&F in repair switch socket combination 5 pin, type 5/6 Amps flush type, 230 volt AC, ISI marked complete all as specified and directed.
S&F in repairs switch socket combination outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, piano flush type, 230 volt AC, ISI marked complete all as specified and as directed.
S&F in repairs Ceiling rose surface bakelite, three terminals, 240V, 50Hz, ISI marked complete all as specified and as directed.
S&F in repairs Buzzer electric, single phase, 240 volt, AC complete all as specified and as directed.
S&F in repairs Bell, Ding Dong type, electric, single phase, 240 volt, AC complete all as specified and as directed.
Supply and fixing angle holder, PVC/Poly carbonate type with back plate suitable for batten fittings complete all as spcified and directed.
Supply and fixing battern holder, PVC/Poly carbonate type with back plate suitable for batten fittings complete all as spcified and directed.
Dismantling and removing 36/40W tube light fitting patty/box/decorative/any type and M&L for replacement with LED tube light fitting, surface mounted lumanaires, 1 x 18 W, 240V, decorative ultra slim round /squar profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack with bipin holders, LED lamps, connector block, etc. complete with all accessories internally pre-wired and including connecting up with flexible copper conductor cable of suitable size complete all as specified and directed. Make : Havells Cat No : LHEXBLP7PN1W020 or equivalant in C&G/Bajaj/Surya/ make as per list of make Appx 'C'
Dismantling and removing tube light rod from any fitting patty/box/decorative and M&L for replacement with LED tube rod 20/22 watt, 240V, PV > 0.90, colour Temp 6500 K, system luminious efficancy > 100Lm/W complete all as specified and directed.
S&F in repairs ceiling fan regulator electronic step type 240 V, AC 50 Hz single pole, 100 watts flush type complete all as specified and as directed.
S&F ceiling fan capacitor of capacity 2.5 MFD complete all as specified and directed.
S&F Exhaust fan capacitor of capacity 4.0 MFD complete all as specified and directed.
S&F PVC insulated unsheathed, copper cable, 1.5 Sqmm AC 230 V complete all as specified and directed.
S&F PVC insulated unsheathed, copper cable, 2.5 Sqmm AC 230 V complete all as specified and directed.
S&F modular socket outlet 2-in-1, 5pin, 6 Amps, 240 volts, controlled by one switch complete all as specified and directed.
Supply and fixing modular socket outlet 2-in-1, 2/3 pin, 6/16 Amps, 240 volts, complete all as specified and directed.
Supply and fixing modular switch socket combination 2-in-1, 5 pin, 6 Amps, 240 volts, controlled by one switch complete all as specified and directed.
Supply and fixing modular switch socket combination, multipurpose 6 pin, 16 amp, 3 module complete all as specified and directed.
Supply and fixing modular fan regulator, 5 step, high speed complete all as specified and directed.
S & F modular switch, one way, 6 Amp, one module, 240 volts complete all as specified and directed.
S & F modular metal flush box of 6 module complete all as specified and directed.
S & F modular metal flush box of 4 module complete all as specified and directed.
S & F modular metal flush box of 3 module complete all as specified and directed.
S & F modular white cover plate of 6 module complete all as specified and directed.
S & F modular white cover plate of 4 module complete all as specified and directed.
S & F modular white cover plate of 3 module complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets etc. to be measured separately), removing materials to store for keeping in safe custody or for taking credit and making good disturbed surface of walls, floors, etc.complete all as specified and directed.
M&L for point wiring for one light / fan / bell point with 1.50 sqmm (nominal area) FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable, 1100 volts grade, controlled by one one-way switch, drawn in and including non metallic rigid PVC casing capping not less than 25mm base size with all fitting and fixing accessories including one run of 1.5 sqmm copper conductor as earth continuity wire connected to common earth dolly by suitable lugs, sunken sheet steel terminal box made out of 1.20 mm thick GI/MS sheet for mounting of fittings like switches, sockets, fan regulators, etc. with 3mm thick laminated hylum sheet cover complete all as specified and directed. Note : Wiring to be done as per approved colour code in IE rule.
All as per BOQ item No. 34.00 above, but for 3 pin 5 Amp socket outlet on independent board complete all as specified and directed.
All as per BOQ item No. 34.00 above, one 5 Amps socket outlet point controlled by one switch on same board with other switches complete all as specified and directed.
All as per BOQ item No. 34.00 above, one 5 Amps socket outlet independent but below the switch board of light points in the same vertical plane , with cables 1.5 sq mm size all as specified and directed.
All as per BOQ item No. 34.00 above, but wiring with 4.0 Sq mm copper cable for 5/15 amp switch socket combination or 3 pin socket out let 15 amp on independent board and provision of 4 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
M&L for point wiring for one light / fan / bell point with 1.50 sqmm (nominal area) FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable, 1100 volts grade, controlled by one one-way switch, drawn in & including non metallic rigid PVC conduit, concealed (ISI marked) medium grade not less than 20mm diameter with all conduit accessories in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 (except on ceiling for fan point only, surface casing capping will be used in lieu of concealed PVC conduit) including one run of 1.5 sqmm copper conductor as earth continuity wire connected to common earth dolly, sunk sheet steel terminal box made out of 1.20 mm thick GI/MS sheet for mounting of fittings like switches, sockets, fan regulators etc. with 3mm thick laminated hylum sheet cover complete all as specified and directed. [Make of Cable : Polycab/ Plaza/ Havells/KEI/V-MARC as approved by GE] Note : Wiring to be done as per approved colour code in IE rule.
All as per BOQ item No.39.00 above, but for 3 pin 5 Amp socket outlet on independent board complete all as specified and directed.
All as per BOQ item No.39.00 above, one 3 pin socket outlet 5 Amps on same board all as specified and directed.
All as per BOQ item No. 39.00 above, but wiring with 4.0 Sq mm copper cable for 5/15 amp switch socket combination or 3 pin socket out let 15 amp on independent board and provision of 4 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
Taking down old unserviceable sub main wiring including service connections, of any size and any description including conduit pipe all as specified and directed.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 4.0 sqmm nominal cross section area and drawing into rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. 20mm external diameter and PVC insulated stranded copper conductor of 4 sqmm nominal cross section area as earth wire including taking down old unserviceable sub main wiring complete all as specified and directed. [Make of Cable : Polycab/ Plaza/ Havells/KEI/V-MARC as approved by GE] Note : (i) Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 4.0 sqmm cable, one run of 4 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 6.0 sqmm nominal cross section area and drawing into rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. 20mm external diameter and PVC insulated stranded copper conductor of 6.0 sqmm nominal cross section area as earth wire including taking down old unserviceable sub main wiring complete all as specified and directed. [Make of Cable : Polycab/ Plaza/ Havells/KEI/V-MARC as approved by GE] Note : (i) Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 6.0 sqmm cable, one run of 6.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
Taking down old unserviceable MCCB/MCB DB of any size and capacity including wooden boards complete all as specified and directed.
S&F sheet metal enclosure for MCB, DB, TPN, 415 Volts, 200 amps rated busbar, 4 way, Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 including wooden rectangle board of first class hardwood of suitable size for mounting of DB box complete all as specified and as directed. [MAKE:Hegar (L&T)/ Siemens/ Legrand/HAVELLS/ make as per list of make Appx 'C' as approved by GE] NOTE:- MCB shall be measured and paid seperatly.
Supply and fixing factory made epoxy powder coated Distribution Board TP & N 4 ways ( VTPN MCCB DB ) and space for MCCB as incomer, with metal door ( IP-43 protection ) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including isolated Neutral Bar, Insulated busbar assembly, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified and directed. [MAKE:Hegar (L&T)/ Siemens/ Legrand/HAVELLS/ make as per list of make Appx 'C' as approved by GE] NOTE:- MCCB shall be measured and paid seperatly.
S&F sheet metal enclosure double door type surface mounted concealed in wall 8 ways, 240 Volts, ISI marked 200 amps bus bar dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed. [MAKE:Hegar (L&T)/ Siemens/ Legrand/HAVELLS/ make as per list of make Appx 'C' as approved by GE] NOTE:- MCB shall be measured and paid separately.
S&F MCCB 160 Amp, 3 Pole, breaking capacity 36 KA with complete electrical connections by appropriate size of copper lugs, complete all as specified and directed. [MAKE:Hegar (L&T)/ Siemens/ Legrand/HAVELLS/ make as per list of make Appx 'C' as approved by GE]
S&F in repairs MCB SP, 240 volts, 10 KA breaking capacity, 'C' curve, of capacity 5 to 32 amps including connection with suitable size aluminium / copper lugs complete all as specified and directed. [MAKE:Hegar (L&T)/ Siemens/ Legrand/HAVELLS/ make as per list of make Appx 'C' as approved by GE]
S&F in repairs MCB SP suitable for 240 volts, AC supply 40 to 63 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed. [MAKE:Hegar (L&T)/ Siemens/ Legrand/HAVELLS/ make as per list of make Appx 'C' as approved by GE]
S&F in repairs MCB SPN suitable for 240 volts, AC supply 6 to 32 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA, complete all as specified and directed. [MAKE:Hegar (L&T)/ Siemens/ Legrand/HAVELLS/ make as per list of make Appx 'C' as approved by GE]
S & F in repairs MCB SPN suitable for 240 volts, AC supply 40 to 63 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed. [MAKE:Hegar (L&T)/ Siemens/ Legrand/HAVELLS/ make as per list of make Appx 'C' as approved by GE]
S & F in repairs MCB TPN suitable for 240 volts, AC supply 63 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed. [MAKE:Hegar (L&T)/ Siemens/ Legrand/HAVELLS/ make as per list of make Appx 'C' as approved by GE]
S&F in replacement 3 pin plug top AC-230 V, 5 Amp, complete all as specified and directed. Make : Anchor/LEGRAND/HAVELLS/ make as per list of make Appx 'C' as approved by GE]
S&F in replacement 3 pin plug top AC-230 V, 15 Amp complete all as specified and directed. Make : Anchor/LEGRAND/HAVELLS/ make as per list of make Appx 'C' as approved by GE]
S&F in replacement sheet metal earth plug & socket, single pole and neutral with and including 1no. single pole MCB 20 Amps 240 volts complete all as specified and directed. [Make:-Legrand Cat No. 607841 or equivalent in L&T/C&S/Havells / make as per list of make Appx 'C' as approved by GE]
S&F in replacement PVC insulated PVC sheathed, flexible circular cable 3 core, 2.5 Sqmm strandered copper conductor AC, 230 V complete all as specified and directed. Make Havells/ Palza/ Polycab/Anchor/ make as per list of make Appx 'C' as approved by GE]
S&F non metallic rigid PVC casing and caping ISI marked of 20mm size complete all as specified and directed.
S&F non metalic PVC conduit ISI marked of size 20mm dia complete all as specified and directed.
S&F LED ultra slim decorative aluminium casted edge ceiling light, recess mounting LED 2 x 2, luminaire 36 watt with all accessories internally pre-wired and including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm two core complete all as specified & directed. [Make :- Havells Cat no VENUSNEOHE2X2R36WLED840PIRSENSOR or Equivalent in crompton/syska / make as per list of make Appx 'C' as approved by GE]
Supply and fix in repairs Coral post top lantern fitting 25 Watt ( for Gate light), energy saving, environment friendly, long life aesthetically designed with symmetrical light distribution with complete accessories all as specified and directed by Engineer in charge. Make: Havells , Cat NO: CORALPT25WLED757PSYMTOPC or equivalent in Bajaj/ make as per list of make Appx 'C' as approved by GE]
S&F in repair LED tube light complete fitting , surface mounted luminanaires , 1x9 watt, 240V, decorative ultra slimround/square profile LED lighting fixture with extruded polycarbonate body, environmental friendly , energy efficient ready to use pack with bipin holders, LED Lamps ,connector block, etc complete with all accessories internally prewired and including connecting up with flexible copper conductor cable with suitable size complete all as specified and directed. Make : Havells Cat No: LHEXBLP7IN1W009 or equivalent in Bajaj/ C&G/ make as per list of make Appx 'C' as approved by GE]
S&F building security light fitting made up of pressure die cast alluminium housing with high efficient LED as lighting source and pc over having top opening separate driver compartment with IP-66 Protection and impact resistance of IK07 including suitable galvanized iron pipe "light grade" brackets 1 mtr length bent to shape to obtain required shape including clamps ,nuts/bolts/washers etc connecting with suitable copper wire of size 23/0.0076 complete all as specified and directed. Make: Haveels Cat No: ENDURAPEARLSL20WLED757SASYTOPCMP or equivalent in Bajaj/C&G/ make as per list of make Appx 'C' as approved by GE]
S&F in replacement flexible wire twin core copper conductor of size 23/0.0076 for ceiling fans, light fittings etc complete all as specified and directed.
S&F LED Aesthetically designed recess mounted panel, ceiling light fitting complete 1x20 watt , 240 V with all accessories internally pre wired and including connecting up with copper conductor cable with suitable size complete all as specified and directed.
M&L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
Dismantling of ceiling fans AC single phase 230 volts of sizes 1200mm/1400mm (collected from MES fan store ) any make / model except old vintage, dismantling its stator, rotor, cutting out burnt copper winding and providing new winding with super enamelled copper winding wire of existing size including cleaning of slots providing oil impregnated insulation paper or minimax, fibre, insulation in slots and well wraping with cotton tape, bind with cotton thread and varnishing over all with winding varnish, cleaning of bearing housing and shaft, replacing spares such as split pins, blade screws etc as required and reassembling and depositing the repaired fan to MES fan store after testing complete all as specified and directed.
All as per BOQ serial item No.69.00 above but exhaust fan, 400/450 mm sweep, AC single phase, 230/240 volts.
All as per BOQ serial item No.69.00 above but exhaust fan, 300/380 mm sweep, AC single phase, 230/240 volts.
All as per BOQ serial item No. 69.00 above but exhaust fan, 230/250 mm sweep, AC single phase, 230/240 volts.
All as per BOQ serial item No. 69.00 above but wall / pedestal fan, of any sweep and capacity
S&F in replacement condenser carrier clip (PVC) in build connector two way fixed with screw on down rod or housing complete all as specified and directed.
S&F in replacement upper set of clips for down rod with rubber Bush (Garari) including set of nut bolts and washer, pin complete all as specified and directed.
S&F in replacement rubber bush (Garari) for mounting at upper side of down rod clip complete all as specified and directed
S&F in replacement gun metal bush self lubricated, any size, suitable for ceiling and wall fans complete all as specified and directed
S&F in replacement Fan condenser 2.5 mfd, 230 volts complete all as specified and directed. [Make: Epcos/Tibcon as approved by GE]
S&F in replacement Fan condenser 3.15 mfd, 230 volts complete all as specified and directed. [Make: Epcos/Tibcon as approved by GE]
S&F in replacement Fan condenser 4.0 mfd, 230 volts complete all as specified and directed. [Make: Epcos/Tibcon as approved by GE]
Supply only the following items for fixing against defective parts of fan taking down under item No 69.00 here in before complete all as specified and directed.
(a) Bearing No 6201'ZZ' [Make : SKF/NBC/FAG as approved by GE]
(b) Bearing No 6202'ZZ' [Make : SKF/NBC/FAG as approved by GE]
(c) Bearing No 6203'ZZ' [Make : SKF/NBC/FAG as approved by GE]
(d) Bearing No 6204'ZZ' [Make : SKF/NBC/FAG as approved by GE]
Taking down ceiling / wall fan from fan hook and disconnection from ceiling rose, dismantling of fan parts i e. down rod and connector/condenser, nut bolts, split pins, rubber bush (garari), condenser carrier clip (PVC), in build connector two way, etc complete servicing by cleaning greasing/oiling in side surface of rotar by CTC with sand paper and repair and re - fitting / reassembling and making the fan fuctional and fixing the fan in position and testing complete all as specified and directed. Note: - Only rubber packing (garari) condenser, condenser carrier clip (PVC) in build connector two way shall be measured and paid separately.
Taking down exhaust fan and disconnection from ceiling rose, dismantling of fan parts i e. connector/ condenser, nut bolts, condenser carrier clip (PVC), in build connector two way, etc complete servicing by cleaning greasing/oiling in side surface of rotar by CTC with sand paper and repair and re - fitting / reassembling and making the fan fuctional and fixing the fan in position and testing complete all as specified and directed. Note: - Only rubber packing (garari) condenser, condenser carrier clip (PVC) in build connector two way shall be measured and paid separately.
S&F in replacement down rod for ceiling fans duly painted with synthetic enameled paint 300 mm long19 mm outer dia with holes on both ends of the rod for connection wire replacement complete all as specified and directed.
S&F in replacement down rod for ceiling fans duly painted with synthetic enameled paint 600 mm long19 mm outer dia with holes on both ends of the rod for connection wire replacement complete all as specified and directed.
S&F in replacement Exhaust fan blade duly powder coated suitable for 450 mm/380mm sweep as per existing complete all as directed .
S&F in replacement Exhaust fan blade duly powder coated suitable for 300 mm/230mm sweep as per existing complete all as directed .
S&F in repairs blade assembly of celling fan of 1200 mm sweep (set of three) of make, colour and pattern as per existing complete all as specified and directed.
S&F in repairs blade assembly of celling fan of 1400 mm sweep (set of three) of make, colour and pattern as per existing complete all as specified and directed.
S&F in repairs outer frame complete with clamps, rubber packing, nut bolts etc & all accessories duly painted suitable for 450 mm /380 mm sweep exhaust fans complete all as specified and directed.
S&F in repairs top and bottom canopy of ceiling fan ( any sweep) of make, colour and pattern as per existing model all as specified and directed
S&F in repairs outer frame complete with clamps, rubber packing, nut bolts etc & all accessories duly painted suitable for 230 mm /300 mm sweep exhaust fans complete all as specified and directed.
M&L for painting of following Item with two coats of DUCO paint (ISI grade) white using spray machine.Spray painting including cleaning, washing and preparation of old painted surfaces including writing MES Nos in all ceiling and Exhaust fan complete all as specified and directed. Note:- Taking down and fixing of fan will be measured under item No. 69.00 here-in-before.
Ceiling fan upto 1200/1400 mm sweep complete.
Exhaust fan upto 280/300/380/450 mm sweep with smoke grey paint
Dismantling of cabin fan of any sweep and overhauling by means of cleaning of stator, oiling & greasing including replacement of nut and bolt, etc and reassembling, re-fixing and testing the fan complete all as specification and directed.
Removing unserviceable fan / bearing shaft (of any type & fan) and shaft welding broken area and threading in lathe machine at appropriate size and refixing in ceiling fan, any type complete all as specified and directed.
Point wiring All as per BOQ item No.39.00 above, but 3 pin socket outlet 15 amps on independent board elect wiring 2.5 sq mm complete all as specified and directed.
S&F Switch piano, flush type, single pole, one way, 5/6 Amps, 230 volt AC, ISI marked complete all as specified and as directed.
S&F Socket outlet multipurpose having provision for 3 pin, 5 Amp and 15 Amp, piano flush type, 230 volt AC complete all as specified and as directed.
S&F Switch socket combination, multipurpose, 3 pin, 5-15 Amp, flush type, ISI marked complete all as specified and as directed.
Dismantling geyser of 25 ltrs capacity and of any description, M&L for cleaning and de-scaling the inner tank and other parts / accessories including inlet, outlet, overflow, geyser element, thermostat, U assembly etc. with brush & cleaning rods and using and circulating concentrated de-scaling solution mixed with water in suitable proportion till the complete deposits/scale is removed and approved by the Engineer-in-Charge, brazing for stopping the leakage of copper inner tank/ gas welding for stopping the leakage of inner steel tanks, fixing the serviceable parts in position, setting insulation properly as required, reassembling the complete geyser after cleaning, repairing and painting, fixing & installation of the geyser in position and its testing to the entire satisfaction of Engineer-in-Charge complete all as specified and directed. NOTE:- (i) De-scaling chemical shall be concentrated HCL of make as approved by GE. (ii) Painting of Geysers shall be on requirement basis and shall be measured and paid for separately under appropriate item of BOQ (iv) Old disturbed insulation shall be made good by the contractor with using old retrieved glass wool and additional quantity of glass wool for insulation, if any required, is deemed to be included in the quoted unit rate. (v) Spares as required shall be measured and paid seperately.
All as per BOQ Sl No. 102.00 above but geyser of capacity 50 Ltrs complete all as specified and directed.
S&F 1.5 KW/ capacity Heating Element, Push/ Screw type with ‘O’ ring including making electrical connection complete all as specified and directed. [Make: Bajaj/ Usha /Theta or as recommanded by manufacturer or equivalent as approved by GE.]
S&F 2.0 KW capacity Heating Element, Push/ Screw type with ‘O’ ring including making electrical connection complete all as specified and directed. [Bajaj/ Usha /Theta or as recommanded by manufacturer or equivalent as approved by GE.]
S&F in replacement Geyser assembly suitable for 25 ltr capacity, ISI marked complete all as specified & directed.
S&F in replacement Geyser assembly suitable for 50 ltr capacity, ISI marked complete all as specified & directed.
S&F in replacement thermostat suitable for 25/50 Ltr Geyser ISI marked with setting range 30 C to 80 C suitable for 230 volts AC electric supply complete all as specified & directed. [Make : Danfoss / Ranco / Indfoss or as recommanded by manufacturer or equivalent as approved by GE.]
S&F in replacement inner tank made of stainless steel suitable for 25 Ltr geyser complete all as specified & directed.
S&F in replacement inner tank made of stainless steel suitable for 50 Ltr geyser complete all as specified & directed.
S&F in replacement outer tank made of steel duly powder coated suitable for 25 Ltr Geyser complete all as specified & directed.
S&F in replacement outer tank made of steel duly powder coated suitable for 50 Ltr Geyser complete all as specified & directed.
S&F in replacement bottom cover suitable for 25 Ltr Geyser complete all as specified & directed.
S&F in replacement bottom cover suitable for 50 Ltr Geyser complete all as specified & directed.
S&F in replacement Indicating lamp (set of two) 230 volts 50 HZ AC suitable for geyser any type (round, square or rectangular type) any capacity complete all as specified and as directed.
M&L for painting of following Item with two coats of DUCO paint (ISI grade) white using spray machine.Spray painting including cleaning, washing and preparation of old painted surfaces including writing MES Nos complete all as specified and directed.
(a) Geyser 25 ltr capacity
(b) Geyser 50 ltr capacity
S&F in replacement PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed. [MAKE:-PRAYAG/ POLYTUFF / make as per list of make Appx 'C' as approved by GE]
S&F in replacemnt PVC connection Nylon braided, heavy duty, 450mm long including rubber washers (suitable for hot water) complete all as specified & directed.
S&F in replacement pressure release valve suitable for 25/50 Ltr capacity geyser complete all as specified & directed.
S&F in replacement PVC insulated multistranded copper conductor, 3 core of size 2.5 Sqmm, 1100 volts grade complete all as specified & directed. [Make:-Polycab/ Plaza/ Havells/KEI/V-MARC / make as per list of make Appx 'C' as approved by GE]
S&F LED tube light complete fitting, surface mounted luminanaires , 1x 20 watt, 240V, decorative ultra slimround/square profile LED lighting fixture with extruded polycarbonate body, environmental friendly , energy efficient ready to use pack with bipin holders, LED Lamps ,connector block, etc complete with all accessories internally prewired and including connecting up with flexible copper conductor cable with suitable size complete all as specified and directed. Make : Havells Cat No: LHEXBLP7PN1W020 or equivalent in Bajaj/ C&G/ make as per list of make Appx 'C' as approved by GE]
Supply, laying, connecting and testing LT XLPE insulated, screened, PVC bedded, armoured, heavy duty cable with aluminium conductor of size 10 sqmm, 2 core, 1100 volts grade, laid in trenches, passing through pipes/ducts, etc complete all as specified and directed. [MAKE:- POLYCAB /HAVELLS INDIA LTD/V-MARC / make as per list of make Appx 'C' as approved by GE]
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for pole foundation, cable trench, etc and getting out in any type of soil complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed. at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection (8 cm below cable & 15 cm above cable) complete all as specified and directed. [Note:-Compacted/punned thickness shall be measured & paid]
Supplying and laying sub class 'B' bricks (modular) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and directed
Taking out old unserviceable cable from trenches of any size and credit to contractor complete all as directed.
Supply, Laying, connecting and testing LT XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade Laid in trenches, passing through pipes/ducts, on walls with shadel, etc including taking out old unserviceable cable , any type of following size/core complete all as specified and directed. Make : Polycab / Havells India Ltd/ RPG cables Ltd / make as per list of make Appx 'C' as approved by GE]
(a) Alluminium conductor of size 120 sq mm, 3.5 core
(b) Alluminium conductor of size 95 sq mm, 3.5 core
(c) Alluminium conductor of size 50 sq mm, 3.5 core
(d) Alluminium conductor of size 16 sq mm, 4 core
M&L in replacement of air break switch vertical/horizontal rocking type gang operated (GOD) triple pole mechanically operated, mounted on insulators (09 insulators) & steel frame with operating mechanism & operating rod of GI pipe 25mm & medium grade with necessary clamps to be operated from ground level 11 KV grade working pressures and current upto 200 amps and complete all as specified and directed. Make :- Jaipuria Brothers / Pactil / MEI / Rastriya / make as per list of make Appx 'C' as approved by GE]
Dismantling cross arms, bracings , supports , clamps and back plates from existing poles (other than dismantled poles) and pole structures complete all as specified and directed.
M&L for replacement of cross arms , bracings, supports, clamps and back plate fabricated from structural sections including nuts, bolts, and washer bending hot or cold , drilling holes for bolts of any size and painting with two coats of aluminum paint over one coat of red oxide primer including preparation of surfaces, complete all as specified and directed.
M& L for replacement of pin type insulator porcelain vitreous white/ brown or green including one galvanised mild steel spindle two GI washer and one GI nut 150mm height, 150mm dia for 11000 Volt grade complete all as specified and directed. Make : BHEL/ Jaipuria /Pactil / make as per list of make Appx 'C' as approved by GE]
M& L for replacement of disc insulator porcelain vitreous 145 mm high and 255 mm dia ball & socket type with tension clamp suitable for conductor single disc assy working pressure 11000 volts complete all as specified and directed. Make : BHEL/ Jaipuria /Pactil / make as per list of make Appx 'C' as approved by GE]
Taking down old /unserviceable GI Tubing of any dimensions all as specified and directed.
M&L for 80mm dia GI tubing light grade with all necessary fittings laid in trenches, fixed to walls, poles, under road/ floor etc for cable protection, complete all as specified and directed.
M&L for 100mm dia GI tubing light grade with all necessary fittings laid in trenches, fixed to walls, poles, under road/ floor etc for cable protection,complete all as specified and directed.
Trimming of tree branches adjecent to OH conductors 2 Mtr clearances from live conductor complete all as directed.
S&F in replacement of MCCB 4 pole, 415 Volts, adjustable type, 160 Amps, 50Hz 36KA, Make : Havells / Legrand / ABB / C & S/ GE power / make as per list of make Appx 'C' as approved by GE]
S&F in replacement of MCCB 4 pole, 415 Volts, adjustable type , 200 Amps, 50Hz 36KA, Make : Havells / Legrand / ABB / C & S/ GE power/ make as per list of make Appx 'C' as approved by GE]
S&F in replacement of MCCB 4 pole, 415 Volts, adjustable type , 250 Amps, 50Hz 36KA, Make : Havells / Legrand / ABB / C & S/ GE power / make as per list of make Appx 'C' as approved by GE]
S&F in replacement of MCCB 4 pole, 415 Volts, adjustable type , 400 Amps, 50Hz, 36KA, Make : Havells / Legrand / ABB / C & S/ GE power/ make as per list of make Appx 'C' as approved by GE]
S&F in replacement of MCCB 4 pole,415 Volts,adjustable type ,630 Amps, 50Hz 36KA, Make : Havells / Legrand / ABB / C & S/ GE power/ make as per list of make Appx 'C' as approved by GE]
S&F in replacement ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 630 Amps all as specified and directed . Make: Semens/Scheneider/ L&T make as per list of make Appx 'C' as approved by GE]
Supply, replacement & straining the ACSR conductor, including binding wire, tape and jumper complete all as specified of size as ordered. Make: Bharat conductors/ Nicco/ Ujala/ VK conductors /make as per list of make Appx 'C' as approved by GE]
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earthing strip of dimension 32X6 mm by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including testing complete all as specified and as directed by the Engineer-in-charge.( NOTE: Necessary excavation to be measured under corresponding item of schedule ).
M&L for installing and commissioning Copper coated Chemical Earthing electrode of length 3 mtr, inner dia of 40 mm and outer pipe of dia 76 mm, after boring 20 metre deep, 150 mm in dia in hard/soft soil with help of boring machine, filling the bore hole with black cotton soil upto 17 mtrs level i.e below the electrode bottom level, filling remaining portion by pouring suitable chemical compound duly mixed with water including necessary PCC earth pit work and including all necessary nut, bolts, washers etc complete all as specified and directed.
M&L for Cutting/drilling suitable holes for inserting/laying of 100/50/40 mm bore GI tubing of any description below/under existing road surfaces/aprons/floors etc with using mechanical and /or manual devices as required at site including making good the disturbed surfaces to match with the existing after laying pipes complete all as specified and directed .
M&L for preparation of old painted surface of LT PCC poles and painting strips in alternate from bottom to top with three strips of black synthetic paint and two strips of white fluoroscent paint ( upto 1.5 metre height ) through out the circumference of pole ( width of each strip shall be 30 cm) including marking pole numbers ina 20 cm dia yellow circle with number writing with black synthetic enamel paint including one coat of lime wash on PCC coping of pole complete all as specified and directed.
M&L for painting of steel tubular pole (swan neck type or straight type) upto 9 meter in height with cross arms, clamps of any length and shape for LT overhead line/ street light with two coats of alluminium paint after scratching out old paint, cleaning the existing surface rust free, preparation of the surface including marking pole no in a 20 cm dia yellow circle with number writing with black synthetic enamel paint and painting strips in alternate from bottom to top with three strips of black enamel paint and two strips of white fluoroscent paint( upto 1.5 m height ) throughout the circumference of pole ( width of each strip shall be 30 cm) , including one coat of lime wash on PCC coping including one coat of lime wash on pole complete all as specified and directed.
M&L for installing GI strip of 32x6 mm dimensions and making proper arrangements for connection between earthing and Transformer/ equipment all as specified and directed.
Schedule of credit (calculation will be done off line) Rs. 159180.00
M/S RAKESH TRADERS
PRAGATI ELECTRICALS AND ELECTRONICS
Raj Contruction
SUNIL ENTERPRISE
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .