| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.5 LAccepted-AOC NO 354 2ND CROSS VARADARAJNAGAR VIDYARANYAPURA POST BANGALORE 5600 097 | 5600097 | L1 | Accepted-AOC L1 | |
| 2 | L2₹29.8 L+₹2.3 L (8.29%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹33.5 L+₹6.0 L (21.9%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹34.2 L+₹6.7 L (24.3%)Rejected-AOC NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L4 | Rejected-AOC L4 | |
| 5 | L5₹34.5 L+₹7.0 L (25.6%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹59,500
Closing Date
16 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Yelahanka
GE (AF) Yelahanka Bangalore - 63
PROVISION OF EMERGENCY BELL INSTALLED FROM NEW ARMOURY TO MAIN GUARD ROOM, DSC GUARD REST ROOM, ORDERLY OFFICER RESTROOM AND PROVN GEYSERS TO CERTAIN SMQS AND CERTAIN MINOR WORKS AND MAJOR REVENUE WORKS AT AF STATION YELAHANKA
2020_MES_367520_2
8790/E8
Open Tender
Civil Works
Item Rate
180 days
AFS Yelahanka
As per NIT
9 documents required · 9 mandatory
₹500
Yes
GE (AF) Yelahanka
₹59,500
Yes
22 Dec 2020
8 Sept 2020
18 Sept 2020
8 Sept 2020
16 Sept 2020
9 Sept 2020
60 days
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil.
Returning, filling in, including spreading, levelling, watering and well ramming in not exceeding 25 cm thick complete.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point as directed.
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size 250 mm x 150mm x 40mm
Supply, lay, spread in trenches river sand including spreading, levelling, punning for cushioning of cable all as specified and as directed. Note:- For payment purpose,only punned thickness shall be considered..
Boring of holes under road, pavement, hardstandinig by trenchless technology using ultrasound technique and necessary maching including HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure.
M&L earthing complete with GI earth plate electrode 600mmx600mmx6mm thick buried in ground vertically to a depth not less than 2.25 mtrs below ground level with top edge of earth plate not less than 1.5 mtrs below ground level connected with GI earth wire of 4 mm dia up to a length of 7.5 mtr long by means of GI bolts, nuts,washers etc and protected by GI pipe light grade 40mm bore and 20 mm dia GI tubing light grade with funnel for watering, connecting to test point, all as shown in electrical plate No.3 of SSR Part I incl necessary earth work and excavation in any type of soil, PCC(1:3:6) type C1 earth chamber with RCC cover slab 50 mm thick,with RCC (1:2:4) type B1 with 8 mm CTD bars re -inforcement both ways at 140 mm C/C with MS hook,including salt, charcoal and provn of test point complete all as spcified and directed by Engr-in-Charge,
Supply and fixing cable route indicator made out of 3 mm thick ms sheet of size 20 cm x 15 cm duly painted with two coats black paint over a coat of red oxide primer and writing HT/LT cable, direction & size of cable with white paint, mounted on angle iron 40x40x3 mm, angle of height 45 cm, (30cm below ground level) duly grouted in PCC block of size 20cmx20cmx15cm including neccessary earth works .
Supply and laying in trenches, LT underground cable of size 4 core 16 Sqmm XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all as directed by Eng-in-Charge.
Suppl and fix GI tube light grade of dia 40mm incl fixing of necessary clamps for protection of cable laying and fixed to walls/pole etc. all as specified and directed.
Supply and fix gong bell single phase 220V AC aluminium cast iron body and weather proof provided with chromium weather proof provided with chromium mild steel pressed gong 12". Make - Edison or equivalent as approved by GE.
Supply and fix switch, 15 amps incl bakelite sheet 3 mm thickness alongwith MS box flushed inside the wall suitable for controlling the bell all as specified and directed.
Supply and fix sheet metal enclosures for MCB distribution board 230 Volts Single pole and neutral 4 way Double door complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface all as specified and directed by Engr in charge.
Supply and fix sheet metal enclosures for MCB distribution board 230 Volts Single pole and neutral 2 way SIngle door flushed inside the wall without bus bar including flushing the DBs inside the walls and making good the disturbed surface also matching with the existing surface complete all as specified and directed by Engr in charge.
Supply and fix MCB Triple pole and Neutral , 415 volts, 20 to 32 Amps 10 KA, all as specified and as directed.
Supply and fix MCB Single pole & neutral 240 volts, 5 to 30 Amps 10 KA all as specified and as directed.
Sub main wiring complete with two runs of 4.0 sqmm single core PVC insulated heavy duty ISI Marked , unsheathed FRLS cable 1100 volts grade, multistranded with copper conductor drawn through and including 20 mm dia non metallic rigid PVC white conduit and conduit/PVC casing caping accessories Concealed /fixed to walls / roofs / floors etc., and including provision of PVC insulated heavy duty ISI Marked , unsheathed cable 1100 volts grade 4.0 sqmm for earth continuity conductor and making good the disturbed surfaces also matching the exisiting surfaces all as specified and as directed by Engr-in-Charge. Note: Two runs of 4.00 sqmm single core PVC cable, PVC conduit/PVC casing caping and one run of 4.0sqmm PVC cable for earth continuity conductor shall be measured and paid as one RM .
Point wiring complete with1.5 sqmm single core PVC insulated heavy duty ISI Marked FR, unsheathed FRLS cable 1100 volts grade with multistranded copper conductor drawn through ERW conduit with all accessories fixed to the surface of walls/roof/ floors / ceiling etc., M S terminal boxes 60 mm deep concealed in walls covered with plastic laminated top cover sheet 3.0 mm thick fixed with cadmium plated iron screws etc incl 1.5 sqmm PVC insulated, unsheathed copper conductorMuistandere FRLS cable 1100V grade as earth continuity conductor & connecting to common earth dolly. for one light/Exhaust Fan point controlled by one switch.
Supply and fix ceiling rose surface bakelite 65x50mm 3 terminals.
Supply and fix Switch flame proof rotary Type with termination box in LM6, 16A, single pole 250V.
S & F flame proof exhaust fan 305 mm (12)" sweep heavy duty 1440 RPM, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of cable 3 core of size 0.5 sqmm (16/0.2 mm) from ceiling rose to fan including writing MES NO. 2 CM height with synthetic enamelled black paint all as specified and as directed Make:- Crompton/Havells/Usha/Sudhir or equivalent as approved by GE
M & L for Provision of hole on the wall for fixing of the exhaust fan and connecting with the ceiling rose complete all as specified and directed by Engr-In-charge.
Sub main wiring complete with two runs of 1.5 Sqmm single core PVC insulated heavy duty ISI Marked unsheathed cable 1100 volts grade, multistanded with copper conductor drawn through and including 20 mm dia non matallic rigid PVC conduit and conduit accessories concealed /fixed to walls/roofs/floors etc.., and including provision of PVC insulated heavy duty ISI Marked, unsheathed cable 1100 volts grade 1.5 Sqmm for earth continuity conductor and making good the disturbed surface also matching the existing surface all as specified and as directed by Engineer-in-charge. Note:- Two Run of 1.5 Sq mm, one Run of 1.5 Sqmm And PVC conduct is measured as one Run or one Meter.
S&F Bell Push flush type.
Supply and fix Bell Multi Music type AC 230 V complete.
Supply and Fixing 36 watts 5700 K Recess Mounting LED fittings with Control driver with higher efficacy full diffuser providing uniform light and luminaire gives soft glare free light suitable for POP / GYPSUM ceiling and all as specified and directed by Engr-in-Charge. Make : Wipro Cat Part No. CRCO10R038HP57GL1 or equivalent as specified in PS.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity 1.5 Ton including necessary sheeting to protect out door unit from climatic conditions all as specified and directed. NOTE : 1. The rates quoted shall deem to include the cost of cutting holes in the brick wall for passing copper tubing and making good the surfcaes to match with adjoining surfaces. 2. The cost of copper tubing of size 5/8" and 1/4" with suitable insulation up to a length of 4.5 mtr is deemed to be included in the unit rate quoted. Cost of copper tubing of size 5/8" and 1/4" with suitable insulation beyond 4.5 mtr will be measured and paid separately under the relevant item. Make : Voltas or equivalent as specified in PS.
Sub main wiring with 2 runs of single core 4 Sqmm PVC insulated copper conductor cable, unsheathed LT 1100 Volts grade drawn through and including non metalic rigid PVC conduit and accessories fixed on wall/roof including one run of 4 Sqmm of PVC insulated copper cable for earth continuity all as directed.
S&F copper tubing of size 5/8'' and 1/4''with suitable insulation fixed on walls/beams etc with suitable clamps all as specified and as directed. NOTE: copper tubing of size 5/8'' and 1/4''with suitable insulation shall be measured as one RM.
Supply and fix voltage stablizer for automatic operation/single phase AC supply 230V 50 Hz naturally air cooled indoor type designed for input variation between 170V to 250V with output valtage stablizer at 230V with accuracy of (+) or (-) 2.50% and capacity 4 KVA
Supply and fix single pole and neutral enclosure with a two pin and earth plug and metal clad socket complete with one single pole MCB 20 Amps
Supply and Fix MCB SP 6 to 32A 10 KA rupturing capacity.
Supply and fix PVC white conduit pipe/PVC flexible pipe and accessories fixed on wall/roof for connecting with AC outdoor unit to nearest Earthpit all as directed.
Point wiring complete with1.5 sqmm single core PVC insulated heavy duty ISI Marked FR, unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including non metallic rigid PVC conduit not less than 20mm dia and conduit accessories fixed to walls / floors / ceiling etc., and including provision of PVC Insualted heavy duty ISI Marked unsheathed copper conductor, 1.5 sqmm for earth continuity conductor and connected to common earth dolly, for the following:- (a) One switch socket outlet point 3 pin 5 Amps on Independent board.
Supply and fix switch socket outlet 5 pin 5 Amps multi pin flush type.
Supply and fix sheet metal enclosures for MCB distribution board 230 Volts Single pole and neutral 12 way Double door with 200 Amps rated busbar complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface incl taking down old unsv DBs all as specified and directed by Engr in charge.
Supply and Fix MCB SPN 6 to 32A, 10 KA rupturing capacity.
Supply and Fix MCB SP 6 to 32A 10 KA rupturing capacity.
Supply and fixing Storage water heater(Geyser) 25 lts cap, 5 star rating complete with water pipe line connection including cutting the existing GI pipe all as specified and directed. Make : Racold or equivalent as specified in PS.
Supply and fix single pole and netural encloser with a two pin and earth plug socket complete without MCB. Make- Indo Asian/ L&T/Legrand/Havells/ABB/Standard
Supply and fix RCCB 25 Amps single phase 220 volts, AC all as specified and directed. Make- Indo asian Cat No. 811700 or equivalent to L&T/Legrand/Havells/ABB/Standard.
Supply and fix PVC connections 15 mm size with PTMT nuts of nength 450 mm
Supply and fix Bib taps fancy type,cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or CPVC pipe.
Supply and fix Stop valve fancy type, chromium plated, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed bith ends for iron pipe.
Supply and laying of CPVC pipes 20 mm dia SDR 11 & plain CPVC SDR 11 fittings and fixed to walls complete all as directed by Engr-in-Charge.
M&L for brick work with sub class ‘B’ old size bricks straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement complete all as specified and as directed.
M&L for Preparation of the new plastered surfaces of walls and applying two coats of cement base paint complete all as specified and as directed.
M&L for rendering 15mm thick in CM 1:6 on fair faces of brick or concrete surfaces finished even & fair without using extra cement complete all as specified and as directed.
M&L for newly plastered surfaces of wall and applying two coats of oil bound distemper on walls with 1mm thick wall care putty including preparation of surfaces.
RAMESH BABU CO
M/S Sneha Enterprises
ANAND REFRIGERATION
SAPTHAGIRI CONSTRUCTIONS
Thirumala Construction
Aditya Associates
UNIVERSAL ENGINEERING
M/S SRI BALAJI ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .