Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹87.9 LAccepted-AOC | ₹87.9 L Quoted ₹90.6 L | L1 | Accepted-AOC Lowest Tenderer |
| 2 | K CHINNU & COMPANY CONSTRUCTIONS PRIVATE LIMITED L2₹94.5 LRejected-AOC | ₹94.5 L | L2 | Rejected-AOC Second Lowest Tenderer |
| 3 | L3₹96.0 LRejected-AOC NO 64 PERUMALPALAYAM PUDHUR THALAVAIPETTAI POST BHAVANI TALUK ERODE DISTRICT 638 312 | ERODE | TAMIL NADU | 638312 | ₹96.0 L | L3 | Rejected-AOC Third Lowest Tenderer |
| 4 | Not Admitted-Fee/PreQual/Technical/Finance | - | - | Not Admitted-Fee/PreQual/Technical/Finance Others-Due to insufficient Document |
| Sl No | Description | Qty | Unit | SAKTHI ENGINEERS L3 | MNM CONSTRUCTION L1 | K CHINNU & COMPANY CONSTRUCTIONS PRIVATE LIMITED L2 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of Floor finish & dadooing walls in cement mortar with Mosaic Tiles / Glazed Tiles / Clay Tiles / Cuddapah Slabs | 1,441.9 | m2 | 73 ₹1.1 L | 79 ₹1.1 L | 75 ₹1.1 L |
| 2.00 | Dismantling the Existing damaged Plain Cement Concrete from floors and clearing away debries neatly from site etc., complete complying with standard specification and as directed by the departmental officers. | 19.6 | m3 | 585 ₹11,466 | 580 ₹11,368 | 580 ₹11,368 |
| 3.00 | Dismantling the old damaged AC sheet roof without roof timber etc. complete and clearing carefully and stacking materials useful for reuse etc. complete complying with standard specification and as directed by the departmental officers. | 17.45 | m2 | 22 ₹383.90 | 21 ₹366.45 | 25 ₹436.25 |
| 4.00 | Dismantling the Reinforced cement concrete works by manual/ by using deploying machineries and including clearing away and carefully stacking the materials useful for reuse etc complete complying with standard specification and as directed by the departmental officers. | 3.5 | M3 | 5,280 ₹18,480 | 5,080 ₹17,780 | 5,400 ₹18,900 |
| 5.00 | Supply and filling in foundation and basement with Gravel in layers of not more than 15cm.thick well rammed watered and compacted with surface vibrator, watered and consolidated etc. complete complying with standard specification and as directed by the departmental officers. | 4.9 | M3 | 730 ₹3,577 | 700 ₹3,430 | 730 ₹3,577 |
| 6.00 | Dismantling, clearing away and carefully stacking materials useful for re-use for Doors and Windows including removal of frames, hinges
and fastenings | 105.88 | m2 | 190 ₹20,117.20 | 185 ₹19,587.80 | 190 ₹20,117.20 |
| 7.00 | Clean removal of old damaged cement plastering from walls and ceiling and clearing the debries neatly from the site as directed by the departmental officers. | 256.5 | m2 | 11 ₹2,821.50 | 10 ₹2,565 | 11 ₹2,821.50 |
| 8.00 | Supplying and filling in foundation, basement, etc with filling Crushed stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. | 13 | m3 | 2,050 ₹26,650 | 1,900 ₹24,700 | 2,400 ₹31,200 |
| 9.00 | Relaying Brick jelly Lime concrete 1:2:5 (one of cement Two of M-sand, Five of brick jelly) using 40m Brick jelly n Lime Mortar 1:2 using lime stone and Crushed stone sand - 10 Cu.mfor foundation etc, including dewataering if found necessary and laid in layer of not more than 15cm thick compacting etc., complete complying with std. specification and as directed by the departmental officers. (For Non-Structural works only) | 32.8 | m3 | 4,900 ₹1.6 L | 4,500 ₹1.5 L | 5,000 ₹1.6 L |
| 10.00 | Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Crushed stone sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used , hacking the surfaces and curing, etc., in all floors complying with standard specification and as directed by the departmental officers | 256.5 | m2 | 380 ₹97,470 | 365 ₹93,622.50 | 390 ₹1.0 L |
Tender Value
Refer Docs
EMD Value
₹54,000
Closing Date
2 Sept 2025, 3:00 pmClosed
The Superintending Engineer, PWD.,
O/o. The Superintending Engineer, PWD., Buildings (C and M) Circle-1, Chepauk, Chennai-5
Special Repairs to Damaged Ceiling, Flooring, Wall, Toilet, Door, Ventilator, Renewing Sanitary fittings arrangements and other repairs in UG Mens Hostel Block II and UG Mens Hostel Block III at Govenrment Kilpauk Medical College and Hospital Campu
2025_PWD_595632_1
PWD/BCMC1/32-2/2025-26
Open Tender
Civil Works
120 days
Kilpauk
Refer Tender Condition
7 documents required · 7 mandatory
₹0
₹54,000
7 Jan 2026
29 Aug 2025
2 Sept 2025
29 Aug 2025
2 Sept 2025
29 Aug 2025
Amount
Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of Floor finish & dadooing walls in cement mortar with Mosaic Tiles / Glazed Tiles / Clay Tiles / Cuddapah Slabs
Dismantling the Existing damaged Plain Cement Concrete from floors and clearing away debries neatly from site etc., complete complying with standard specification and as directed by the departmental officers.
Dismantling the old damaged AC sheet roof without roof timber etc. complete and clearing carefully and stacking materials useful for reuse etc. complete complying with standard specification and as directed by the departmental officers.
Dismantling the Reinforced cement concrete works by manual/ by using deploying machineries and including clearing away and carefully stacking the materials useful for reuse etc complete complying with standard specification and as directed by the departmental officers.
Supply and filling in foundation and basement with Gravel in layers of not more than 15cm.thick well rammed watered and compacted with surface vibrator, watered and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Dismantling, clearing away and carefully stacking materials useful for re-use for Doors and Windows including removal of frames, hinges and fastenings
Clean removal of old damaged cement plastering from walls and ceiling and clearing the debries neatly from the site as directed by the departmental officers.
Supplying and filling in foundation, basement, etc with filling Crushed stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Relaying Brick jelly Lime concrete 1:2:5 (one of cement Two of M-sand, Five of brick jelly) using 40m Brick jelly n Lime Mortar 1:2 using lime stone and Crushed stone sand - 10 Cu.mfor foundation etc, including dewataering if found necessary and laid in layer of not more than 15cm thick compacting etc., complete complying with std. specification and as directed by the departmental officers. (For Non-Structural works only)
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Crushed stone sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used , hacking the surfaces and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
Brick work in Cement Mortar 1:6 using best quality Burnt Clay Brick of size 9” x 4 3/8” x 2 3/4” with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement incluuding Cost of Mortar Plasticizer curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge.
Ground floor
Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers.
Plastering with Cement Mortar 1:3 (One Cement and Three Plastering Crushed stone sand) 12mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including mortar plasticizer at 200ml per 50Kg of cement used, finsihing, curing, etc.,complete in all floors complying with standard specification and as directed by the departmental officers.
Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination by rubbing with wire brush. Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed. Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete
Plain Cement Concrete 1:2:4 (one cement, two Crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.- Mixing by manual means
Cement Concrete 1:5:10 (One cement, Five Crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken jelly for flooring including laying, consolidating, finishing, rendering the top surface rough to receive the floor, curing, etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers -Mixing by Manual means
Cement Concrete 1:1-1/2:3 (One Cement, One and a half Crushed stone sand and Three hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for all RCC items of works excluding cost of reinforcement grill and fabricating charges centering and shuttering but including Super Plasticiser, laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary and bearing surfaces of walls, beams etc. shall be finished smooth with Cement Mortar 1:3 (One Cement and Three Crushed stone sand) and kraft paper laid over it without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers - manual mix
Ground floor
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire)
Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in accordance with IS 1443 over a cement mortar bed of 20mm thick in Cement Mortar 1:3 (One Cement and Three crushed stone Crushed stone sand) with required Cement Slurry and Mortar Plasticizer and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Provision for vaccum dewatering in fresh concrete works 80 to 120mm thick by levelling with double framed screed vibrator finishing with power floatter and power trowel and indentical works, the cost includes cutting of hardened concrete at equal intervals for expansion joints and filling the joints with suitable material etc., complete and as directed by the departmental officers.
Flooring with ceramic tiles of following size and variety conforming to IS 15622 laid over cement mortar bed of 20 mm thick in cement mortar 1:3 (One Cement and Three Crushed stone sand) with required Cement Slurry and Mortar Plasticizer including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Dadooing walls with following best approved quality, white / colour glazed tiles conforming to IS 15622 of following sizes in Cement Mortar 1:2 (One Cement and Two crushed stone Crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Dadooing with Nano Polish Vitrified Tiles of size 600 x 600 x 8mm
Renewing the damaged beading with new PVC trim wall corner beading of best and approved quality including labour charges for fixing in position etc Complete.
Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn,teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications. (The EWC and flushing tank wiht all accessories should be got approved by the Executive Enginer before use on works)
Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with “P” or “S” trap conforming to BIS with Crushed stone sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two Crushed stone sandand Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works).
Supply and fixing in position of best Indian make white / colour glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers. (The urinal should be got approved by the Executive Engineer before use on works.)
Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia “B” class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat ofanti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works).
Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of Crushed stone sandand five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three Crushed stone sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works)
Supplying and fixing in position CP shower rose with CP stop cock arrangement of size15mm dia inlet and 100mm outlet to the pipe line with necessary cutting, threading and jointing using shellac etc., complete complying with standard specification and as directed by the departmental officers (The CP shower rose should be got approved by the Executive Engineer before use on works).
Supplying and fixing factory made Wood Polymer Composite (WPC) solid door shutter with frame of size 100x65mm with high density rigid solid wood polymer composite of 0.70 WPC foam sheet as per ISI marked of 20-30mm thick, mitre cut at two corners and joined and two vertical door profiles are to be reinforece to horizontal member and the door shall be fixed to the wall using 6nos 150mm long M.S hold fastners through the frame, aluminium fixtures, butt hinges, aldrop, tower bolt, handles, including no.of screws, bolt and nuts including labour charges for fixing the frame in position and fixing the shutter to the frame (The vertical frame of door shall be embedded in flooring for a depth of not less than 10mm) etc., complete complying with standard specification and as directed by the departmental officers.
Supplying, fabricating and fixing in position of Aluminium anodised natural colour matt finish of single leaf fully panelled sliding door with 12mm thick bothside prelaminated partile board at the Shutter bottom rail:[email protected] kg/m,Top & Verticle 50x44.45x2.50mm @ 1.292 kg/m,Lock rail 50x44.45x2.50mm @ 1.292 g/m, Running channel section:[email protected] kg/m, and necessary accessories such as Alu.clips 17.15x17.27x1.50mm @ 0.176 kg, Alu handle 100x30mm @ 0.988 kg/mfull length of handles on both sides, lock, roller, including cost of materials, labour charges and power consumption charges required for fabrication including chipping, dismantling and waking hole to the required extent in RCC column, beam masonry with power drill wherever necessary and redoing the damaged portion to the original condition afterfixing etc. complete. All the Alu. sections are to be anodised.with matt finish under electically contolled condition in accordance with IS 1868/1962 for an average anodic film thickness of 15 microns etc.,
Supplying, fabricating and fixing in position of Aluminium anodised powder coated finish of double leaves door with half panelled with 12mm thick bothside prelaminated partile board at bottom and half glazed using 5.50mm thick Plain glass at top.The outer frame shall be with aluminium box section 101.60x44.45x3.18m at 2.319kg/m and Shutter frame made of section-Vertical &Top rail: 50x44.45x2.50mm @ 1.292 kg/m and Bottom rail : 100 x 44.45 x 2.50mm @ 1.974 kg /m , Lock rail: 50x44.45x2.5mm @ 1.292 kg/m,Alu. Clips: 17.15x17.27x1.50mm @ 0.176 kg/mAlu. Handle: 100x30mm @ 0.988 kg/m and necessary accessories such as aluminium clips, rubber beading, PVC felt, handle for a length of shutter (both sides), locking arrangements, furniture fittings such as aluminium tower bolts-250x12mm - 2 Nos., aluminium tower bolt 200x12mm - 1No., aluminium Hydraulic door closer - 2Nos .,lock-1No., Door stopper with rubber bush including cost of materials, labour charges and power consumption charges required for fabrication including chipping,dismantling and making hole to the required extent in RCC column, beam masonry with power drill wherever necessary and redoing the damaged portion to the original condition afterfixing etc. complete complying with standard specification and as directed by the deparmental officers.. All the Alu. sections are to be anodised with matt finish under electically contolled condition in accordance with IS 1868/1962 for an average anodic
Supplying and fixing solid core flush shutter of following type with thickness and necessary T.W. internal lipping alround conforming to IS 2202-1(1999)including cost of wind appliances and furniture fittings such as 6 Nos of SS 304 Grade Parliament Hinges of Size (125mm x 150mm), 3 Nos. 300x12mm aluminium tower bolt 1 No. 200x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops, 3 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete complying with standard specification and as directed by the departmental officers - Double leaf.
Servicing and refixing in position of Aluminium anodized natural colour matt finish Two panels openable type window of size 1.20x1.30m in all floors such as renewal of necessary accessories such as rubber beadings, special hinges, handle including supplying and fixing 4mm thick plain glass icluding cost of all materials but excluding of alum.frame, labour , power consumption required for fabrication, drilling holes in RCC Column slab, masonry walls wherever necessary with power drills to the required extent and make good to the original condition after fixing and also as directed
Manufacturing supplying and fixing in position of teracotta jally 20x20x5cm thick approved quality and design in cement slurry including cost of materials labour curing lifting fixing in position etc, complete complying with standard specification and as directed by the departmental officers in all floors.
Supplying , fixing and roofing with colour galvalume sheet of 0.47mm thick with all necessary accessories such as J/V bolt and nuts of suitable length with suitable bitumen washers complete complying with standard specification and as directed by the departmental officers.
Distempering the Two Coats of approved quality including preparation of surface, the rate includes cost of brushes, high scaffolding arrangements, neat finishes, etc., complete complying with standard specification and as directed by the departmental officers.
Painting Old Plastered Wall Surface with One finishing coats of ready mixed (Emulsion) of approved quality and colour over the existing wall in all floors etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Finishing the top of roof with one course of machine pressed tiles of following size of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers
Providing two legged scaffolding using 48.30mm dia heavy duty MS pipe over all height of 3.00m the distance between 2 legs being 1.25m and the spacing of the post being 2m in each rows and providing platform with C.W. planks using 40mm thick silver oak and 1.00m wide in complete form with horizontal bracings @ 1.50m c/c vertical direction and with cross bracings using same 48.30mm dia including cutting, threading assembly with red oxide primer, labour charges cost of specials such on large plate, shoe, carcher, coupling, bolt and nut transportation charges. The bottom of vertical post shall rest on 300x300x70mm 1:2:4 concrete base etc complete complying with standard specification and as directed by the departmental officers.
Initial height of 3m of length
Every additional 2.50m height
Supplying, laying and jointing UPVC pipes of Class 5 (having working pressure of 10 kg/sq.cm) conforming to IS 4985- 2000 of approved quality and best variety of the following dia including cutting, and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3(2003) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roofand making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The UPVC pipes shall be got approved by Executive Engineer before use on works. - Internal water supply - above ground level.
25mm UPVC pipe
Supplying, laying and jointing UPVC pipes of Class 5 (having working pressure of 10 kg/sq.cm) conforming to IS 4985- 2000 of approved quality and best variety of the following dia including cutting and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3 (2003) and fixing into wall with teak woodplugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works - External water supply above ground level / Below ground level.
32mm Dia UPVC
Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work.
32mm dia Gate valve
25 mm dia Gate valve
Supplying UPVC Specials (with working pressure 10 kg. / sq.cm.) in water supply arrangements (both in internal and external water supply arrangements etc., complete complying with standard specification and as directed by the departmental officers.
25mm Elbow
32mm Elbow
32 to 25mm Reducer
25 to 20mm Reducer
32mm Tee
25mm Tee
Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap / Swan neck tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Brands like Metro, Jaguar) (Taps should be got approved by the Executive Engineer before use on the works)
Screw Down Tap
Pillar Tap
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level
75mm PVC Pipe
110mm PVC Pipe
160mm PVC Pipe
Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and redoing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works).
160mm PVC Bend
110mm PVC Bend
75mm PVC Bend
110mm PVC Elbow
110mm PVC Elbow with door
75mm PVC Eblow with door
110mm PVC "Y" with door
Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of neceSORy PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of “U” clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification and as directed by the departmental officers
Three Floors(110mm Downfall Pipe)
Two Floors(110mm Downfall Pipe)
Construction of INSPECTION CHAMBER following clear sizes including earth work excavation, CC 1:5:10 of 10 cm thick and brick work in Cement Mortar 1:5 [One cement and Five Crushed stone sand] using best quality of Clay burnt Bricks of size 9” x 43/8” x 23/4” with Class designation of 7.5 and Plastering with Cement Mortar 1:3 [One Cement and Three Plastering Crushed stone sand] 12 mm thick to inner and outer sides and wearing coat 1:3:6 [One Cement, Three Crushed stone sand and Six Aggregate] 15 cm thick and covered with precast slab 5 cm thick etc., complete complying as directed by the departmental officers as per standard specification.
CLEAR SIZE 0.60 X 0.60
Supplying and fixing best approved best quality Procelain CP soap tray of size 150 x 150mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications. (The soap tray should be got approved by Executive Engineer before use on works).
Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works).
Supplying and fixing of 5 HP Mud Pump Submersible Pump with accessories of starter, Main Switch, Panel Board etc. complete to suit the need. (The pump ste should be got approved by the EE before supply).
Supplying and fixing of PVC insulated and sheathed 3 core 2.5 sq.mm flat type copper cable conforming to IS 694/1990 of good approved quality and brand including cost of materials, labour charges for fixing etc., complete complying with standard specification and as directed by the departmental officers.
Collecting the scattered debries using tipper machinery from the campus and loading into the tipper long and conveying away the same to outside by lorry to a lead of 3km entirely within city limit including loading and unloading charges and dumping in low laying area and leveling neatly etc., complete complying with standard specification and as directed by the departmental officers. (200GF volume capacity)
K CHINNU & COMPANY CONSTRUCTIONS PRIVATE LIMITED (BID ID -1446620)
SAKTHI ENGINEERS (BID ID -1446426)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_714893.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid