| 4 | Admitted-Finance NO 4 SRIRAMULU VILLA MULLAI STREET KANDAN NAGAR TIRUTTANI 631209 | TIRUTTANI | THIRUVALLUR | TAMIL NADU | 631209 | Admitted-Finance |
| 5 | Rejected-Technical 4 1 70 1 ROAD NO 11 SNEHAPURI NACHARAM HYDERABAD 500 076 | HYDERABAD | MEDCHAL MALKAJGIRI | TELANGANA | 500076 | Rejected-Technical NO remark in WLR Sep 2021 of CECZ report |
Tender Value
₹10.0 L
EMD Value
₹20,000
Closing Date
3 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I RD AVADI
AGE I RD AVADI CHENNAI 600054
REPAIRS AND MAINTENANCE OF HIGH BAY LIGHT FITTINGS AND CONNECTED WORKS AT TECHNICAL AREA CVRDE AVADI
2021_MES_492669_1
8461/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
AVADI
As per NIT
8 documents required · 8 mandatory
₹500
AGE I RD AVADI
₹20,000
Yes
2 Feb 2022
6 Dec 2021
5 Jan 2022
6 Dec 2021
3 Jan 2022
20 Dec 2021
6 Dec 2021 - 20 Dec 2021
60 days
Amount
Checking/ Testing including taking down of high bay light / building security light fittings, any type/ wattage from CVRDE factory work shops of Working hights of fittings up to 10 Mtrs approximately from ground level and to find out defects on site and repairing etc and repairing by changing the defective parts including minor repairs to cable connection / loose connection / necessary cleaning the bowl / perplex cover where provided including re-fixing of high bay light / building security light fittings in its original place / position after cleaning the complete all as specified and directed. Note : (i) Spares of light fittings shall be measured & paid separately under serial item no. 2.00 to 9.00 of BOQ as a supply only items. The labour element of fixing of serial item no 2.00 to 9.00 of BOQ is included in this item and nothing shall be paid extra on this account. The unserviceable fittings shall be replaced with new light fitting shall be measured and paid under relevant items of BOQ. (ii) The T&P and necessary ladders etc shall be arranged by the contractor at his own arrangements. The rates of this aspect is included in this item and nothing shall be extra paid on this account (iii) During currency period of contract, contractor shall depute sufficient manpower for attending the complaints regularely. If any fault / defects occurred, contractor shall rectify/ replace the same without any extra cost.
Supply only LED driver suitable for above 70 upto 100Watts, IP- 65, 230V, 50Hz.
Supply only LED driver suitable for above 100W upto 150 Watts IP-65, 230V, 50Hz.
Supply only driver protection circuit of 10 KA, voltage range input 180-380 volt, output 230 volt ± 5 % tolerance, auto relay set up, to restore power supply on normal input voltage, over voltage, under voltage & overload protection system complete suitable for 70 watts to 200 watts LED fittings.
Supply only HPSV Lamps 400 Watts AC 230 V, 50 Hz and including removing the old unserviceable lamps all as directed. Make : Philiphs /Crompton / Havells/Bajaj
Supply only 400 Watts ballast copper wounded suitable for AC 230 Volts 50 Hz, 400 Watts HPSV lamp fittings including removing the old unserviceable ballast all as directed. Make : Philiphs /Crompton / Havells/Bajaj
Supply only lamp holder, screw type suitable for 400/250 Watts HPMV /MH Lamp fittings and including removing the old unserviceable lamp holders all as directed by Engineer in Charge. Make : Havells/ Jothi
Supply only capacitor 33 mfd suitable for 400W HPSV/MH lamp and including removing the old unserviceable condensor all as directed. (Make : Seimens / KEIL/Havells)
Supply only of Ignitors 400W HPSV/MH lamp fittings and including removing the old unserviceable ignitor. Make : Philiphs /Crompton / Havells / Bajaj
Supply and fixing in repair energy efficient highbay light fitting of 80 Watt including No. of LEDs in fittings as per manufacturer’s instructions for lighting of 80 watt ,epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficiency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided with inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fitting including making electrical connection for cable connection and taking down old unserviceable high bay light fitting from any height complete all as specified and directed . Make:Havells Cat Part No. SAUCERGENXPROHBP80WLED757P60 DBOLTG / LHB11-80-CDL/60-M of CG/ LH21-122-060-57-XX of WIPRO.
Supply and fixing in repair energy efficient highbay light fitting of 100Watt including No. of LEDs in fittings as per manufacturer’s instructions for lighting of 100 watt ,epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficiency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided with inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fitting including making electrical connection for cable connection and taking down old unserviceable high bay light fitting from any height complete all as specified and directed by Engineer in charge. Make: Havells Cat Part No. SAUCERGENXPROHBP100WLED757P 60DBOLTG / LHB11-100-CDL/60-M of CG/ LH21-162-060-57-XX of WIPRO.
Supply and fixing in repair energy efficient highbay light fitting of 120Watt including No. of LEDs in fittings as per manufacturer’s instructions for lighting of 120 watt ,epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficiency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided with inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fitting including making electrical connection for cable connection and taking down old unserviceable high bay light fitting from any height complete all as specified and directed by Engineer in charge. Make: Havells Cat Part No. SAUCERGENXPROHBP120WLED757P 60DBOLTG / LHB11-120-CDL/60-M of CG/ LH21-192-060-57-XX of WIPRO. Note for item No. 10,11 & 12 :(i) Cable for connection of LED Light fitting shall be is included in this item and nothing shall be paid extra on this account
Supply and fixing in replacement of energy efficient LED building t fitting of not less than 30 Watt, epoxy powder coated pressure die cast aluminium housing and toughened glass with IP 66 degree of protection, system luminous efficiency more than 100 lumens / watt and PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fitting including making electrical connection for cable connection complete all as directed. Make : WIPRO CAT No. LR02-331-XXX-57-XX / Havells CAT No. ENDURACITYLITEPLATPLUSSL30WLED757SASYBOPC / PHILIPS CAT No. CBRP046 LED 30 CW MR S1 PSU GR. Note :- Cable for connection of LED Light fitting and including bracket of GI Pipe 32 mm bore bend to shape with 2 Nos MS flat 32 x 3 mm thick with suitable nuts & bolts for mounting the fitting shall be is included in this item and nothing shall be paid extra on this account
M&L for replacement of submain wiring for high bay luminairs at 10 Mtr height roof to control DB complete with 2 x 2.5 Sqmm + 1 x 2.5Sqmm earth wire of FRLSH PVC insulated and unsheathed cable with multistranded copper conductor drawn through stove enamelled steel conduit with conduit and all accessories like bend, tees, junction box incl taking down the old wiring etc all as directed. Note: 3 Runs of 2.5 Sqmm copper cable with 1 Run of steel conduit will be measured as one run.
Earthing complete with GI earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth wire 4mm dia by means of bolts, nuts, washers of galvanised iron or steel, GI earth wire shall be protected by 15mm dia GI pipe 'light grade', watering pipe 20mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL, and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 50mm thick RCC cover (1:2:4) type B1 mix with 8mm dia TMT bars @ 100mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, complete including testing on completion all as speciified and as directed. Note: The Quoted rate includes for GI wire 4mm and GI protection pipe of 15mm bore light grade upto 7.50 mtr long.
Taking out old unserviceable XLPE LT cable of any size from wall/roof and replacing with new supply and Laying XLPE LT UG cable of size 10 sqmm 2 core 1100 Volt grade aluminium conductor fixed to wall / pole including necessary connection and suitable size of thimbling complete all as specified and as directed by Engineer-in-Charge
M/s GM Constructions
EASHWAR ELECTRICALS
SREE VENKATESWARAS CONSTRUCTIONS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .