| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC COLABA MUMBAI | ₹1.1 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹1.1 Cr+₹5.9 L (5.49%)Rejected-Finance COLABA MUMBAI | ₹1.1 Cr+₹5.9 L (5.49%) | L2 | Rejected-Finance Other Than Being Lowest |
| 3 | L3₹1.2 Cr+₹8.4 L (7.81%)Rejected-Finance COLABA MUMBAI | YAVATMAL | MAHARASHTRA | 445001 | ₹1.2 Cr+₹8.4 L (7.81%) | L3 | Rejected-Finance Other Than Being Lowest |
| 4 | L4₹1.2 Cr+₹13.1 L (12.2%)Rejected-Finance PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | ₹1.2 Cr+₹13.1 L (12.2%) | L4 | Rejected-Finance Other Than Being Lowest |
| 5 | L5₹1.2 Cr+₹15.1 L (14.1%)Rejected-Finance | ₹1.2 Cr+₹15.1 L (14.1%) | L5 | Rejected-Finance Other Than Being Lowest |
| Sl No | Description | Qty | Unit | Monarch Enterprises L1 | Escon Elevators Pvt Ltd L3 | Veer High Tech Solution L2 | Shree Elevator Engineering Co. L5 | shakti engineering and electrical works L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Repair/maintenance of lifts including carrying out daily check and periodical services of fully automatic electrical lift with power operated door, simplex collective control system with repair/maintenance of unserviceable damaged parts such as bearings, bushes, all type of guide shoes, headers, hangers, door ropes, door cards, car door sills, landing door cills, door locks, cabin lights, minor repair of cabin fan, control cards, and its contacts, hall push buttons and its spares, connector/links, welding of cracked /broken and MS parts, door safety edge and sensor mechanical safety lock, magnetic lock or contact, car position indicator, and all connected accessories, necessary wiring of hall push button assembly, repair/maintenance of broken COP/LOP buttons and display, including cover, Fire alarm, Firemen button glass, Intercom, alarm/hooters, damaged hand rail, Shaft, light/switches, complete with illuminated push button and direction indicator with LED display with LPT/LPC card of stainless steel inclusive of harness wiring for laminating of push button of each floors and cutting wall making good disturbed surface with masonry work to make with existing surface & cable as per requirement and ensure smooth and safe operation of lifts , fixing of loose rail bracket with necessary masonry work , changing of broken anti skid pvc rubber mat and air freshener at lift cabin, removing old paint by paint removers and cleaning with scrappers, any number of coats, steel surfaces and lift machine and all equipment held in machine room and rust painting at car top and door and allied parts , two coats of painting of gear motor, all MS channels and Control Panels using spray gun ensure safe and smooth functioning of lift and complete maint of car top, binding of loose wire at control panel and , dewatering of lift wells in case of any emergency arise complete all as specified and directed.
Location- Kartikeya, Gemini, Revati, Rohini, WNC(O) Mess VIP, WNC(O) Mess Main Bldg - 06 PS (408Kg) - 07 Nos lift Make : Existing at Bldg Monarch | 11 | Per month | 75,600 ₹8,31,600 | 72,600 ₹7,98,600 | 74,200 ₹8,16,200 | 72,450 ₹7,96,950 | 71,000 ₹7,81,000 Lowest |
| 2.00 | Ditto All as per item No 1.00 above here in before but 08 PS lift (544 Kgs) in building :Location- Kartikeya, Gemini, Revati, Rohini , Sravana, Swati, WNC Old Annex Bldg building : 08 Nos lift , Make : Existing at Bldg Monarch | 11 | Per month | 85,600 ₹9,41,600 | 94,624 ₹10,40,864 | 84,200 ₹9,26,200 | 1,10,300 ₹12,13,300 | 83,000 ₹9,13,000 Lowest |
| 3.00 | Ditto All as per item No 1.00 above here in before but 13 PS lift (844 Kgs) in building :
Location- Meena, Kanya, Chitra, Swati ,Anuradha, Sravana 13 PS (884Kg) - 08 Nos lift, Make : Existing at Bldg Monarch | 11 | Per month | 1,08,600 ₹11,94,600 | 1,03,000 ₹11,33,000 Lowest | 1,19,813 ₹13,17,943 | 1,07,800 ₹11,85,800 | 1,04,210 ₹11,46,310 |
| 4.00 | Ditto All as per item No 1.00 above here in before but 1000kg goods lift in building :
Location: Swati & Meena (G+13 upper floor) 02 Nos lift, Make : Existing at Bldg Monarch | 11 | Per month | 33,960 ₹3,73,560 | 31,600 ₹3,47,600 | 37,466 ₹4,12,126 | 42,150 ₹4,63,650 | 30,000 ₹3,30,000 Lowest |
| 5.00 | Ditto All as per item No 1.00 above here in before but 2000kg goods lift in building:
Location: Archana (G+15 upper floor) 01 Nos lift
Notes for item No-1 to 5
(i) One mechanic shall be available round the clock at lift complaint cell for safe & smooth functioning of the lift.
(ii) The AMC should cover any minor parts of lifts if its functions are found defective, the same should be repaired or replaced by the OEM as per the timeline covered under norms as directed by Engr-in-Charge/GE.
(iii) Two mechanic shall be available round the clock at lift complaint cell for safe & smooth functioning of the lift. (iv) The detailed duty mechanics of the firm shall report to the JE Concerned at the Lift complaint cell for receiving the complaints at round the clock daily including Sundays and holidays.
(v) The detailed lift mechanics shall sign (their shift wise) in the attendance register kept with lift cell. (vi) Duty Mechanics shall be available as per the shift timings specified in the tender and he will report to JE in-Charge or Lift Cell in-Charge. In case of emergency he will function according to their direction. If he is found absent or move without intimating to in-Charge of Lift Cell or JE he will be treated as absent for the said shift and recovery to this effect for Rs 1500/- per shift shall be affected., Make : Existing at Bldg Monarch | 11 | Per month | 18,500 ₹2,03,500 | 25,300 ₹2,78,300 | 20,410 ₹2,24,510 | 17,150 ₹1,88,650 Lowest | 21,900 ₹2,40,900 |
| 6.00 | Taking down old car door VVVF drive supply and fixing in replacement car door (VVVF) drive with all accessories confirming to IS and matching with existing model, specifications and same capacity of existing items complete all as specified and directed . | 7 | Each | 29,500 ₹2,06,500 | 35,600 ₹2,49,200 | 28,600 ₹2,00,200 Lowest | 46,000 ₹3,22,000 | 48,960 ₹3,42,720 |
| 7.00 | Complete Machine Overhauling by opening of Gear removing old dirty oil, cleaning & Replacing of new Gear oil refilling of the same with new packing & adjustment of thrust bearing ,defective bushes as & where required& keep it into perfect working order complete all as specified and directed. | 8 | Each Job | 29,800 ₹2,38,400 | 35,921 ₹2,87,368 | 32,281 ₹2,58,248 | 36,069 ₹2,88,552 | 27,695 ₹2,21,560 Lowest |
| 8.00 | Taking down old unserviceable DBR supply and fixing Aluminium covered wire wound dynamic breaking resistor to absorb the reserve energy dissipation of motor during regeneration in control operation suitable for existing capacity motor up to 15 HP VFD complete all as specified and directed. | 8 | Each | 26,500 ₹2,12,000 | 25,310 ₹2,02,480 | 35,980 ₹2,87,840 | 24,585 ₹1,96,680 Lowest | 46,300 ₹3,70,400 |
| 9.00 | supply and fix in replacement Load Sensor, with audio and visual indication on COP with necessary wiring , testing complete all as specified and directed. | 18 | Each | 21,300 ₹3,83,400 | 24,823 ₹4,46,814 | 20,000 ₹3,60,000 | 25,781 ₹4,64,058 | 19,150 ₹3,44,700 Lowest |
| 10.00 | Dismantling and taking out unserviceable car door for goods lift from car cabin supply and fixing new car door comprises of 02 No power operated, auto telescopic / centre opening by horizontal sliding stainless steel panel of flush type panels complete with removed headers, hangers, door drive unit with full beam infrared sensor up to full length of car door, aluminium sill VVVF door drive unit for motor complete with all accessories control connection complete all as specified and directed. | 1 | Each | 1,18,960 ₹1,18,960 | 1,17,900 ₹1,17,900 Lowest | 1,25,295 ₹1,25,295 | 1,42,365 ₹1,42,365 | 1,46,300 ₹1,46,300 |
Tender Value
₹1.1 Cr
EMD Value
₹1.8 L
Closing Date
29 Dec 2025, 6:00 pmClosed
CWE (NW) Mumbai
CWE (NW) Mumbai
REPAIR AND ROUTINE MAINTENANCE OF LIFTS IN BUILDING SRAVANA, ANURADHA, KATHIKEYA, GEMINI, ROHINI,REVATI, KANYA, SWATI, CHITRA, ARCHANA, WNC(O) MESS UNDER GE(NW) NOFRA
2025_MES_742342_1
8673/CWE(NW)Mumbai/E8
Open Tender
Civil Works
Item Rate
330 days
GE (NW) NOFRA
Class- B
Category -c (ii)
8 documents required · 8 mandatory
₹1,000
GE (NW) NOFRA
₹1.8 L
Yes
16 Feb 2026
2 Dec 2025
31 Dec 2025
2 Dec 2025
29 Dec 2025
24 Dec 2025
2 Dec 2025 - 22 Dec 2025
Amount
Repair/maintenance of lifts including carrying out daily check and periodical services of fully automatic electrical lift with power operated door, simplex collective control system with repair/maintenance of unserviceable damaged parts such as bearings, bushes, all type of guide shoes, headers, hangers, door ropes, door cards, car door sills, landing door cills, door locks, cabin lights, minor repair of cabin fan, control cards, and its contacts, hall push buttons and its spares, connector/links, welding of cracked /broken and MS parts, door safety edge and sensor mechanical safety lock, magnetic lock or contact, car position indicator, and all connected accessories, necessary wiring of hall push button assembly, repair/maintenance of broken COP/LOP buttons and display, including cover, Fire alarm, Firemen button glass, Intercom, alarm/hooters, damaged hand rail, Shaft, light/switches, complete with illuminated push button and direction indicator with LED display with LPT/LPC card of stainless steel inclusive of harness wiring for laminating of push button of each floors and cutting wall making good disturbed surface with masonry work to make with existing surface & cable as per requirement and ensure smooth and safe operation of lifts , fixing of loose rail bracket with necessary masonry work , changing of broken anti skid pvc rubber mat and air freshener at lift cabin, removing old paint by paint removers and cleaning with scrappers, any number of coats, steel surfaces and lift machine and all equipment held in machine room and rust painting at car top and door and allied parts , two coats of painting of gear motor, all MS channels and Control Panels using spray gun ensure safe and smooth functioning of lift and complete maint of car top, binding of loose wire at control panel and , dewatering of lift wells in case of any emergency arise complete all as specified and directed. Location- Kartikeya, Gemini, Revati, Rohini, WNC(O) Mess VIP, WNC(O) Mess Main Bldg - 06 PS (408Kg) - 07 Nos lift Make : Existing at Bldg Monarch
Ditto All as per item No 1.00 above here in before but 08 PS lift (544 Kgs) in building :Location- Kartikeya, Gemini, Revati, Rohini , Sravana, Swati, WNC Old Annex Bldg building : 08 Nos lift , Make : Existing at Bldg Monarch
Ditto All as per item No 1.00 above here in before but 13 PS lift (844 Kgs) in building : Location- Meena, Kanya, Chitra, Swati ,Anuradha, Sravana 13 PS (884Kg) - 08 Nos lift, Make : Existing at Bldg Monarch
Ditto All as per item No 1.00 above here in before but 1000kg goods lift in building : Location: Swati & Meena (G+13 upper floor) 02 Nos lift, Make : Existing at Bldg Monarch
Ditto All as per item No 1.00 above here in before but 2000kg goods lift in building: Location: Archana (G+15 upper floor) 01 Nos lift Notes for item No-1 to 5 (i) One mechanic shall be available round the clock at lift complaint cell for safe & smooth functioning of the lift. (ii) The AMC should cover any minor parts of lifts if its functions are found defective, the same should be repaired or replaced by the OEM as per the timeline covered under norms as directed by Engr-in-Charge/GE. (iii) Two mechanic shall be available round the clock at lift complaint cell for safe & smooth functioning of the lift. (iv) The detailed duty mechanics of the firm shall report to the JE Concerned at the Lift complaint cell for receiving the complaints at round the clock daily including Sundays and holidays. (v) The detailed lift mechanics shall sign (their shift wise) in the attendance register kept with lift cell. (vi) Duty Mechanics shall be available as per the shift timings specified in the tender and he will report to JE in-Charge or Lift Cell in-Charge. In case of emergency he will function according to their direction. If he is found absent or move without intimating to in-Charge of Lift Cell or JE he will be treated as absent for the said shift and recovery to this effect for Rs 1500/- per shift shall be affected., Make : Existing at Bldg Monarch
Taking down old car door VVVF drive supply and fixing in replacement car door (VVVF) drive with all accessories confirming to IS and matching with existing model, specifications and same capacity of existing items complete all as specified and directed .
Complete Machine Overhauling by opening of Gear removing old dirty oil, cleaning & Replacing of new Gear oil refilling of the same with new packing & adjustment of thrust bearing ,defective bushes as & where required& keep it into perfect working order complete all as specified and directed.
Taking down old unserviceable DBR supply and fixing Aluminium covered wire wound dynamic breaking resistor to absorb the reserve energy dissipation of motor during regeneration in control operation suitable for existing capacity motor up to 15 HP VFD complete all as specified and directed.
supply and fix in replacement Load Sensor, with audio and visual indication on COP with necessary wiring , testing complete all as specified and directed.
Dismantling and taking out unserviceable car door for goods lift from car cabin supply and fixing new car door comprises of 02 No power operated, auto telescopic / centre opening by horizontal sliding stainless steel panel of flush type panels complete with removed headers, hangers, door drive unit with full beam infrared sensor up to full length of car door, aluminium sill VVVF door drive unit for motor complete with all accessories control connection complete all as specified and directed.
Dismantling and taking out unserviceable car door for any passenger lift from car cabin supply and fixing new car door comprises of 02 No power operated, auto telescopic / centre opening by horizontal sliding stainless steel panel of flush type panels complete with removed headers, hangers, door drive unit with full beam infrared sensor up to full length of car door, aluminium sill VVVF door drive unit for motor complete with all accessories control connection etc. for any capacity of lift complete all as specified and directed..
Dismantling and taking out old unserviceable landing door from various floors & supply and fixing new landing door comprising of 02 No power operated centre opening / side opening by horizontal sliding stainless steel panel suitable for same lift complete with door suitable for 06/08/13PS /Any capacity goods lifts complete all as specified and directed.
Dismantling and taking out existing car & supply and fix new car made of stainless steel hair line finish, 1.5mm thick, stainless steel 304 grade, as per existing size., arrangement to fix car door , made of MS sheet platform covered with 5 mm thick aluminium flooring, SS False ceiling with LED lights ,Fan Etc., for any capacity of lift complete all as specified and directed..
Dismantling and taking out old unserviceable main VVVF unit supply and fix new main VVVF drive unit of suitable for any capacity in existing panel and connected with existing system including testing and commissioning confirming to same model with specification and same capacity of existing items complete for smooth and jerk free working of lift complete all as specified and directed.
Taking down old unserviceable Aluminium chequered plate supply & fixing new aluminium Chequered plate of thickness upto 5mm including removing existing plates complete all as specified and directed.
Disconnecting and taking out old defective infra red door sensor of any type and make and supply and fixing new infra red door sensor of up to full length of car door complete all as specified and directed.
Taking down old unserviceable main steel wire rope after disconnecting old wire rope from counter weight, pulley and car cabin and supply and fix new governor steel wire rope 8 mm dia, ungalvanised, 8/19 construction in and including necessary connection with counter weight pulley and car cabin with clamps,nuts, bolts and washer etc. complete all as specified and directed.
Taking down old unserviceable main steel wire rope after disconnecting old wire rope from counter weight, pulley and car cabin and supply and fix new main steel wire rope 10 mm dia, ungalvanised, 8/19 construction in and including necessary connection with counter weight pulley and car cabin with clamps,nuts, bolts and washer etc. complete all as specified and directed.
Taking down old unserviceable main steel wire rope after disconnecting old wire rope from counter weight, pulley and car cabin and supply and fix new main steel wire rope 13 mm dia, ungalvanised, 8/19 construction in and including necessary connection with counter weight, pulley and car cabin with clamps, nut, bolts and washers etc. complete all as specified and directed.
Taking down unserviceable cabin fan from car cabin and supply and fixing new new car cabin fan non oscillating type axial flow single speed 300mm sweep, 240 volts ISI mark with grill complete all as specified and directed.
Supply and fixing in repairs LED light fittings 5 watt, not less than 110 lumen/ watt complete with and including LED, all accessories complete all as specified and directed.
Taking down unserviceable landing push button box complete with stainless steel plate push buttons and combined digital position indicator and arrow indicator supply and fix landing push button box complete with stainless steel plate push buttons and combined digital position indicator and arrow indicator complete all as specified and directed.
Disconnecting & taking out defective COP assembly, supply and fix new COP assembly for any PS lifts illuminated push button for floor position indicator, alarm, stop butten , door close, door open, cabin light, ,cabin fan key operated switch for attendant, over load indication including direction indicator of 7 segment display with CPI card on stainless steel face plate duly connected with existing control and electric system complete all as specified and directed.
Taking down unserviceable main pulley with complete set Supply & fixing new main pulley with complete set complete all as specified and directed.
Taking down unserviceable pit pulley and governor pulley with complete accessories and Supply &fixing new pit pulley and governor pulley complete all as specified and directed.
Dismantling and taking out all defective batteries from existing ARD and supply and fixing new batteries suitable for ARD including necessary connection like battery terminals of brass and copper lead heavy duty to connect the battery terminal of complete all as specified and directed.
Dismantling and taking out all defective batteries from existing ARD and supply and fixing new batteries suitable for ARD including necessary connection like battery terminals of brass and copper lead heavy duty to connect the battery terminal of complete all as specified and directed.
Dismantling and taking out unserviceable travelling cable from hoist way & supply and fixing new travelling cable PVC insulated 12/16/24 Core flat/ round type with standard copper conductor, conforming to relevant IS in and including thimbles, suspended type freely move with car cabin up and down movement between ground and upper floors including necessary proper connection with mid way junction and other connection required in circuit complete all as specified and as directed.
Disconnecting and taking out unserviceable emergency alarm system complete Supply & fixing new emergency alarm system assembly on ground floor landing complete with PCB card battery backup charging unit and speaker including necessary control/electric connection wiring with COP and control panel in Central machine shope and various other lift complete all as specified and directed..
Supply and laying aluminium strip of size 25x3 mm from test point to lift machine room and to be terminated to the control panel, machine, other equipment installed in machine room for any bldg complete all as specified and directed.
Supply and Fixing in replacement of Car and Cwt Buffer Spring with all accessories of suitable for any capacity of Lifts at various Bldgs of NOFRA, all as directed by Engineer-in-Charge.
Supply and Fixing in replacement of Floor Announcement System with all accessories for any capacity of Lifts installed at various locations of NOFRA complete all as specified and directed.
Supply and fixing in replacement new toe guard with connected accessories suitable for goods/passenger lifts complete complete all as specified and directed.
Dismantling and taking out ARD control system and commissioning and testing of new ARD system including PC cards/diodes suitable for upto 15 HP motor including wiring with connected item in existing building. Make: Must be suitable for As per exiting
Taking down unserviceable/ burnt lift motor from the lift machine room and Rewinding of electrical motor upto 15HP capacity 3 phase 415 V , including rewinding of the motor by proper gauge of copper wire with class E insulation with Varnishing, heating and re-assembling and testing at the site complete all as specified and directed.
Taking down broken granite slab and Material and labour for 18/20 mm thick mirror polished black granite slab, machine cut, mirror polished set on vertical surfaces 300 mm width allround with lift facial elevation including back casting CM (1:3) 15 mm thick and joint filling with white cement with pigment to match with shade of granite for lift archive at all floors complete all as specified and directed..
Taking down unserviceable Stainless Steel hand rail & Supply and Fix new hand rail arrangement inside the lift with all accessories suitable for any capacity of lift at various locations complete all as specified and directed.
Dismantling and taking out unserviceable control panel & supply and fix new control panel in hinged MS powder coated cabinet, with control wiring comprising with multiple microcontrolled programmed chip based, controlled by pulse modulation, complete with all safety devices such as thermal overload protection, over current protection, auto phase link to each other in network, and compatible to existing capacity VVVF drive confirming to IS 14665 , 3 phase supply, 415 volts, and motor capacity upto 15 HP complete including proper connection with proper lugs, terminal connectors screws and motor connection with galvanised sheet trucking 24 SWG including wiring of main motor with suitable size of stranded copper cable etc. and panel suitable for bldg ( G+9) complete all as specified and directed.
Taking down unserviceable Shaft encoder and Supply and Fix new Shaft encoder suitable for any capacity of lift with all accessories complete all as specified and directed.
Veer High Tech Solution (BID ID -3509627)
Escon Elevators Pvt Ltd (BID ID -3509373)
shakti engineering and electrical works (BID ID -3511439)
Shree Elevator Engineering Co. (BID ID -3510662)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
8673.rar
Tender Documents • 1.77 MB
BOQ_831290.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .