Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.6 LAccepted-AOC P O WEST SRIPURIA DIST TINSUKIA ASSAM PIN 786 145 | TINSUKIA | ASSAM | 786145 | L1 | Accepted-AOC Accepted M/s Shree Trilok Electric Corporation | |
| 2 | L2₹21.0 L+₹1.4 L (6.94%)Rejected-Finance PO LEKHAPANI DIST TINSUKIA PIN 786 180 ASSAM | 786180 | L2 | Rejected-Finance NOT THE LOWEST BIDDER | |
| 3 | L3₹22.2 L+₹2.6 L (13.3%)Rejected-Finance AT MAIN ROAD DANDAI PO PS DANDAI DIST GARHWA | LATEHAR | JHARKHAND | 822112 | L3 | Rejected-Finance NOT THE LOWEST BIDDER | |
| 4 | Rejected-Technical | - | Rejected-Technical REJECTED DUE TO DOCUMENTS NOT SUBMITTED BEING UN ENLISTED | |
| 5 | Rejected-Technical NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | - | Rejected-Technical REJECTED IN TERMS OF NOTE d OF APPX A TO NIT |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
11 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE DINJAN
COMMANDER WORKS ENGINEER DINJAN
SPL REPAIR REPLACEMNT OF BER TRANSFORMER AT LEKHAPANI MIL STN
2024_MES_658026_1
84293
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Lekhapani
AS PER TENDER DETAILS
8 documents required · 8 mandatory
₹500
GE Lekhapani
₹38,000
Yes
27 Sept 2024
6 Jun 2024
18 Jul 2024
6 Jun 2024
11 Jul 2024
27 Jun 2024
Amount
Isolating existing U/S and BER Transformers of capacity ranging from 100 KVA to 400 KVA from sub stns after taking down, disconnecting HT/LT electric supply, unscrewing the nuts/bolts, lifting by crane and transporting through truck to MES Store yard for safe custody complete all as specified and directed by the Engr-in-charge.
Supplying, installing, connecting, testing & commissioning of transformer of capacity 100 KVA (energy efficient level 3), outdoor type, floor mounted 11 KV on HT side and 433 volts on LT side at no load step down 3 phase 50 c/s AC double wound ( copper) oil immersed naturally cooled with external cooling tubes/fins core type. Transformer with off load tapping on HT side to vary secondary voltage ± 7.5% in steps of ± 2.5%. The transformer shall confirm with the requirement of IS-1180 (Part-I) :2014 and IS 2026, subsequently amended upto date and oil shall confirm to IS-335, 1993. The temp rise shall not exceed 55 degeree centigrade in winding and 45 degree centrigrade in oil when measured by the resistance method after continous full load run and on ambient temp of 48 degree centigrade, copper wound specified and as directed. The transformer shall be complete with the following :-(a) HV Bushing of suitable size. (b) LV glands and cable box of suitable size. (c). Oil conservator with fully cap & drain valve (d) Dehydrating breather with first fill of dehydrating agent & oil seal. (e ). Themometer pocket with themometer dial of suitable size. (f). Two earthing terminals on tank and take cover with lugs to suit 32x6 mm GI strip. (g). Rating plate & diagram plate. (h). Terminal marking plate. (j). Four plain rollers. (k). Oil filter plug with connection complete. (l). Extra bushing for neutral outside the cable box for providing independent earthing. (m) oil filling hole with cap. (n). First filling of oil. (o). One cable box on LV side with one cable gland suitable for reception of 01 No 3.5 core upto 300 Sqmm LT cable. And as per specification given in Particular specifcation and as per original manufacturer instructions. Note:- The quoted rates shall include the cost of construction of hard standing/ foundation of suitable size for mounting of transformer as per manufacturer instructions and as directed by engineer in charge.
Supplying, installing, connecting, testing & commissioning of transformer of capacity 200 KVA (energy efficient level 3), outdoor type, floor mounted 11 KV on HT side and 433 volts on LT side at no load step down 3 phase 50 c/s AC double wound ( copper) oil immersed naturally cooled with external cooling tubes core type. Transformer with off load tapping on HT side to vary secondary voltage ± 7.5% in steps of ± 2.5%. The transformer shall confirm with the requirement of IS-1180 (Part-I) :2014 and IS 2026, subsequently amended upto date and oil shall confirm to IS-335, 1993. The temp rise shall not exceed 55 degeree centigrade in winding and 45 degree centrigrade in oil when measured by the resistance method after continous full load run and on ambient temp of 48 degree centigrade, copper wound specified and as directed. The transformer shall be complete with the following :-(a) HV Bushing of suitable size. (b) LV glands and cable box of suitable size. (c). Oil conservator with fully cap & drain valve (d) Dehydrating breather with first fill of dehydrating agent & oil seal. (e ). Themometer pocket with themometer dial of suitable size. (f). Two earthing terminals on tank and take cover with lugs to suit 32x6 mm GI strip. (g). Rating plate & diagram plate. (h). Terminal marking plate. (j). Four plain rollers. (k). Oil filter plig with connection complete. (l). Extra bushing for neutral outside the cable box for providing independent earthing. (m) oil filling hole with cap. (n). First filling of oil. (o). One cable box on LV side with one cable gland suitable for reception of 01 No 3.5 core upto 300 Sqmm LT cable. And as per specification given in Particular specifcation and per original manufacturer instructions. Note:- The quoted rates shall include the cost of construction of hard standing/ foundation of suitable size for mounting of transformer as per manufacturer instructions and as directed by engineer in charge.
S & F XLPE cable end termination, heat shrinkable, indoor type complete with jointing material and accessories suitable for voltage 6.35 kV/ 11 kV (Earthed), 3 core, 50 sqmm to 95 sqmm complete all as specified and as directed.
S & F XLPE cable end termination, heat shrinkable, outdoor type complete with jointing material and accessories suitable for voltage 11 kV (Earthed), 3 core, 50 sqmm to 95 sqmm complete all as specified and as directed.
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
S & F earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 mm X 6 mm galvanised mild steel strip complete all as specified and as directed.
RIA CONSTRUCTION (BID ID -3057238)
ms singh construction (BID ID -3047898)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .