Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.0 CrAccepted-AOC 13 29 304 IIIRD FLOOR EAST PATEL NAGAR OPP HOTEL SIDDARATHA NEW DELHI 110008 | WEST | DELHI | 110008 | ₹1.0 Cr | L-1 | Accepted-AOC Being L-1 |
| 2 | L-2₹1.0 Cr+₹93,461.50 (0.93%)Rejected-AOC NOT FOUND | ₹1.0 Cr+₹93,461.50 (0.93%) | L-2 | Rejected-AOC Other than L-1 |
| 3 | L-3₹1.0 Cr+₹2.6 L (2.55%)Rejected-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹1.0 Cr+₹2.6 L (2.55%) | L-3 | Rejected-AOC Other than L-1 |
| 4 | L-4₹1.1 Cr+₹6.0 L (5.99%)Rejected-AOC | ₹1.1 Cr+₹6.0 L (5.99%) | L-4 | Rejected-AOC Other than L-1 |
| 5 | L-5₹1.1 Cr+₹7.6 L (7.55%)Rejected-AOC 110059 NEW DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110059 | WEST DELHI | DELHI | 110059 | ₹1.1 Cr+₹7.6 L (7.55%) | L-5 | Rejected-AOC Other than L-1 |
Tender Value
₹1.4 Cr
EMD Value
₹2.1 L
Closing Date
31 May 2025, 6:00 pmClosed
CWE Chandimandir
HQ CWE Chandimandir, PIN-134107
CWE/CHM(U)-107/2024-25 LAYING OF NEW CABLE, RELOCATION OF TRANSFORMER AND ALLIED WORKS NEAR CHANDIMANDIR RAILWAY STATION AT CHANDIMANDIR MIL STN
2025_MES_703069_1
CWE/CHM(U)-107/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (U) Chandimandir
Class B Cate b(ii)
9 documents required · 9 mandatory
₹1,000
GE (U) Chandimandir
₹2.1 L
5 Jul 2025
29 Mar 2025
2 Jun 2025
29 Mar 2025
31 May 2025
24 May 2025
29 Mar 2025 - 3 Apr 2025
Amount
Excavation in trenches in soft/ loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cables, poles etc. not exceeding 10 sq. metre on plan and not exceeding 1.5 metre in depth and getting out complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches in hard/ dense soil not exceeding 1.50 metre wide, exceeding 1.5 metre and not exeeding 3.0 metre in depth, for erection of poles etc. and getting out complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed by Engineer-in-Charge.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-Charge.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type-1, flat, of size 300 mm x 180 mm x 40 mm complete all as specified and as directed by Engineer-in-Charge.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type-1 flat, of size 250 mm x 150 mm x 40 mm complete all as specified and as directed by Engineer-in-Charge.
Material & labour for sand filling with clean dry find sand unwashed including gently punning around cables as specified in SSR Part-I in trenches/ ducts for cable protection complete all as specified and directed by Engineer-in-Charge. Note:- Only punned thickness shall be measured and paid.
Supply and laying Double wall corrugated HDPE duct pipe of 50 mm outer dia conforming to IS:14930 Pt-II with antirodant and non flame propergating properties of make and colour as approved by Engineer-in-Charge with fittings as protection to cable, laid in tranches or fixed to poles/walls complete all as specified and directed by Engineer-in-Charge.
Supply, laying, jointing and testing 11 KV (Earthed), XLPE insulated, electric power cables (heavy duty), aluminium conductor, screened, PVC bedded, galvanised steel strip or wire armoured, having cross sectional area 120 Sqmm, 3 core complete all as specified and as directed by Engineer-in-Charge. Note :- Earth work, sand cushioning, pipe and PCC cable protection cover shall be measured and paid separately.
All as per Serial Item No 9.00 here-in-before but size 240 sqmm 3 core
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and as directed by Engineer-in-Charge.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm complete all as specified and as directed by Engineer-in-Charge.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm complete all as specified and as directed by Engineer-in-Charge.
S&F GI tubes 100 mm bore, 'light grade' for cable protection on poles/ walls/ under road/ culvert etc including all fiittings and fixtures complete all as specified and as directed by Engineer-in-Charge.
S&F GI tubes 50 mm bore, 'light grade' for cable protection on poles/ walls/ under road/ culvert etc including all fiittings and fixtures complete all as specified and as directed by Engineer-in-Charge.
M&L for horizontal boring under road of suitable size either manually or using mechanical devices for passing cables and protection pipe of upto 100 mm bore complete all as specified and as directed.
S&F route indicator for HT cable, disc type, of size 150 mm dia made out of Cast Iron, of 8 mm thickness embossed with "MES HT CABLE" and fixed on angle iron 35 x 35 x 5 mm, 600 mm long and painted in anti corrosive brown color paint including embedding in PCC foundation block 1:2:4 type B-1 of size 300 x 300 x 300 mm, duly fixed in ground complete all as specified and as directed by Engineer-in-charge.
S&F in trenches, ducts or fixing along the poles or passing through pipes or laid under floors etc and testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts having cross sectional area 400 sq. mm 3.5 core, including connecting and testing with suitable size of lugs complete all as specified and as directed by Engineer-in-charge.
All as per Serial Item No. 18.00 here-in-before but of size 50 sqmm, 3.5 core
All as per Serial Item No. 18.00 here-in-before but of size 35 sqmm, 3.5 core
All as per Serial Item No. 18.00 here-in-before but of size 25 sqmm, 4 core
All as per Serial Item No. 18.00 here-in-before but of size 16 sqmm, 4 core
S&F 1100 volts grade heavy duty flat twin core cable PVC insulated with stranded aluminium conductor of size 10.0 sqmm and overall PVC sheathed in service connections including connecting with suile size of lugs and testing for funtioning complete all as specified and as directed by Engineer-in-charge.
S&F Multi stranded copper cable PVC insulated unearthed 1100 Volts grade of size 2.50 Sqmm, 3.00 Core for connection from junction box to light fitting and making connection including connecting with suitable size of lugs and testing for functioning of light fitting complete all as specified and as directed by Engineer-in-charge.
Supply and fixing of high power energy saving LED street light fittings with lens, of capacity 120 watt with inverter system efficacy (lm/w) not less than 100 lumens per watt, total system lumen not less than 12000 lumens, PF not less than 0.95, CRI not less than 70, colour temp. 5700K + 300K, surge protection not less than 5 KV, high pressure die cast aluminium alloy LM6 housing IP 65/ 66 class 1 protection, toughened glass cover, driver efficiency > 85% with constant output of current and voltage against input voltage variation 120 to 270 volt at 50 Hz (+ 5%), THD< 10%. The driver should be fittedwith electrolytic capacitor of minimum 105 degrees rating and must be with phase to phase protection complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED Solar street light fitting, 36 Watt, including galvanized steel pole, mono crystalline SPV panel, in built lithium Ferro phosphate (LiFEPO4) battery, solar panel, MPPT charge controller and PIR sensor with colour temprature 6000-650 K complete all as specified and as directed by Engineer-in-Charge. Note:- Excavation & earth work shall be measured for separately under relevant items of this schedule.
M&L for security light mounting bracket made out of 50 mm bore GI ' Light grade' pipe 1.50 Metre long bent to required shape as in bracket for steet light fittings fixed with two pair of MS flat iron clamp of size 50 mm X 6 mm thickness of required shape with nuts, bolts and washers of suitable size and fixed to steel tubular pole including painting of braket surface with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-charge.
S&F Non metallic junction box made out of PVC sheet of size not less than 240 mm x 130 mm x 110 mm, hinged with lockable arrangement with and including aluminium bus bar TPN capacity 200 Amps with one MCB 6 Amp, SP, 10 KA, ‘C’ curve with provision of tapping incoming and outgoing cable connection with gland box of suitable size and fixing on pole or grouting in PCC muff complete all as specified and as directed by Engineer-in-charge.
Supply, installation testing and commissioning out door type Street Light Panel for suitable load, factory made CPRI approved openable from front & rear double door type, dust and vermin proof, fabricated out of 3.15 mm CRCA sheet duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with 4 Nos heat shrink insulated bus bar of rating 1.5 of incoming MCCB including all connection with aluminium strip pillar board shall be provided with danger notice plate with skull and bone sign, making all electrical incoming and out going electrical cable connection with new lugs, glands to be provided at cable entries, including MS channel frame of ISMC 75 at base of panel only and 04 Nos legs of not less than 600 mm long each below the base of panel made of angle iron 50 x 50 x 6 mm for grouting purpose in PCC 1:2:4 type B-1 (using 20 mm graded stone aggregates) complete all as specified and directed and comprising of following accessories :-
The Panel shall be comprising of following: (a) INCOMMING: MCCB 125A 4P 415 Volts, 50 HZ, breaking capacity 25 KA with adjustable thermal and adjustable magnetic release -01 No. (b) BUS BAR: 200 Amps Aluminium TPN heat shrink insulated including all connection with aluminum strip -1Set. (c) METERING: Multifunction Meter (VAF+PF) with Ct’s & Set of R Y B Led Indicating Lamps -1 Set. (d) OUTGOING: MCCB 63A 3P 415 Volts, 50 HZ, breaking capacity 16 KA with adjustable thermal and adjustable magnetic release - 03 Nos. (e) Earthing Terminals -2Nos. (f) Danger Notice Plate dully riveted/ Pasted on front door -1 No
Supply, install, testing and commissioning of LT Panel board double door, outdoor type suitable for floor mounting, of appropriately size and equipped with locking arrangement, fabricated out of 2 mm thick CRCA sheet for inner shell and 3 mm thick CRCA sheet for outer shell and ISMC 75 for base frame, powder coated, dust/ water and vermin proof, suitable for 415 volts 3 phase 50 Hz, complete with and including the following accessories:-
(a) Four pole MCCB 630 amps, 50 KA, 415 volts with adjustable thermal & magnetic release and lcs = 100 % of Icu - 01 No (Incomming) (b) Aluminium strip bus bars sleeve insulated and mounted on epoxy insulators, 1000 amps capacity, TPN - 01 set. (c) Three pole MCCB 250 amps, 36 KA, 415 Volts with adjustable thermal and magnetic release and lcs = 100 % of Icu - 01 No, Three pole MCCB 160 amps, 36 KA, 415 Volts with adjustable thermal and magnetic release and lcs = 100 % of Icu -04 No, Three pole MCCB 100 amps, 16 KA, 415 Volts with adjustable thermal and magnetic release and lcs = 100 % of Icu -02 Nos (all as outgoings)
(d) LED type indicators RYB - 01 set. (e) LT CTs 630/5 amps - 03 Nos (f) Multi functional meter 96 mm x 96 mm, flush mounting, digital type - 01 No (g) Earthing terminals - 02 Nos. (h) Danger notice plate duly rivetted/ fixed on front door - 01 No (j) Internal wiring of the panel board circuits with copper conductor PVC insulated single core cable of suitable dia including control MCB SP in each circuit.
Design, Fabricate, supply, installation and testing outdoor type cubical panel board bus bar box with MCCB suitable for 3 phase 4 wire, 50 Hz supply system factory fabricated made out of CRCA sheet steel of 3 mm thick for outer shell and 2 mm thick for inner shell with front openable door with locking arrangement complete with powder coated and suitable packing material for IP-54 degree of protection and including provision of 40 mm x 40 mm x 5 mm angle iron base frame of suitable size for mounting the panel board at a height of 450 mm above GL and grouted in PCC foundation, of suitable size for accommodating following switchgears complete:-
(a) Incomming- MCCB, 350 A, 4 Pole, 36 KA (Ics=100%Icu), 415 V, 50 Hz, with adjustable thermal and magnetic release - 01 No (b) outgoing- TPN Aluminium bus bar 500 Amps 4 strips provided with heat shrinkable coloured PVC sleeve insulation mounted on insulators suitable for connecting 2 or 3 outgoing cables including provision suitable glands. (c) LED type indicators RYB - 01 set. (d) LT CTs 400/5 amps - 03 Nos (e) Multi functional meter 96 mm x 96 mm, flush mounting, digital type - 01 No (f) Earthing terminals - 02 Nos. (g) Danger notice plate dully rivetted/fixed on front door - 01 No (h) Internal wiring of the panel board circuits with copper conductor PVC insulated single core cable of suitable dia including control MCB SP in each circuit.
Design, Fabricate, supply, installation and testing outdoor type cubicle panel board bus bar box with MCCB suitable for 3 phase 4 wire, 50 Hz supply system factory fabricated made out of CRCA sheet steel of 3 mm thick for outer shell and 2 mm thick for inner shell with front openable door with locking arrangement complete with powder coat painting and suitable packing material for IP-54 degree of protection and including provision of 40 mm x 40 mm x 5 mm angle iron base frame of suitable size for mounting the panel board at a height of 450 mm above GL and grouted in PCC foundation, of suitable size for accommodating following switchgears complete:-
(a) Incomming- MCCB, 400 A, 4 Pole, 36 KA (Ics=100%Icu), 415 V, 50 Hz, with adjustable thermal and magnetic release - 01 No (b) Outgoing- TPN Aluminium bus bar 600 Amps 4 strips provided with heat shrinkable coloured PVC sleeve insulation mounted on insulators suitable for connecting 2 or 3 outgoing cables including provision suitable glands. (c) LED type indicators RYB - 01 set. (d) LT CTs 400/5 amps - 03 Nos (e) Multifunctional meter 96 mm x 96 mm, flush mounting, digital type - 01 No (f) Earthing terminals - 02 Nos. (g) Danger notice plate dully rivetted/fixed on front door - 01 No (h) Internal wiring of the panel board circuits with copper conductor PVC insulated single core cable of suitable dia including control MCB SP in each circuit
Supply, erecting and fixing in true vertical position, steel tubular swaged pole Type 410, SP–55, 11 metre long, complete with cast iron base plate, pole cap/ finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal welded throughout entire length of pole with and including painting with two coats of black bituminous paint externally upto planting depth and internally throughout and remaining exterior portion of pole with two coats of aluminium paint over one coat of red oxide primer complete all as specified and directed by Engineer-in-Charge. Note:- Earthwork, PCC work in foundation & coping of pole, Cross arms and anti climbing device shall be measured and paid for separately.
Supply, erecting and fixing in true vertical position, steel tubular swaged pole Type 410, SP–31, 9 metre long, complete with cast iron base plate, pole cap/ finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal welded throughout entire length of pole with and including painting with two coats of black bituminous paint externally upto planting depth and internally throughout and remaining exterior portion of pole with two coats of aluminium paint over one coat of red oxide primer an providing reflective strips of 10 cm width upto a height of 1.2 meter from ground level in aternate yellow and black colour around the pole and marking pole number at appropriate height with shade and colour as approved byEngineer-in-Charge complete all as specified and directed by Engineer-in-Charge. Note:- Earthwork, PCC work in foundation & coping of pole, Cross arms and anti climbing device shall be measured and paid for separately.
M&L for PCC 1:4:8, type D-2 (using 40 mm graded crushed stone aggregates) as in pole foundations etc complete all as specified and as directed by Engineer-in-charge.
M&L for PCC 1:3:6, type C-2 (using 40 mm graded crushed stone aggregates) as in foundation filling & mass concrete for poles/ struts etc including provision of necessary form work complete all as specified and as directed by Engineer-in-charge.
M&L PCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregates) as in pole/ strut coping complete all as specified and as directed by Engineer-in-charge.
S&F gang operated air break switches with vertical isolation complete with drop out fuse unit triple pole, 12 insulator (composite polymeric insulator) type, manually operated, mounted on insulators and steel frame, with operating mechanism worked from ground level for rating 400 Amps, 11000 volts complete with GI operating pipe of heavy duty grade of suitable length complete all as specified and as directed by Engineer-in-charge.
All as per Serial Item no 37.00 here-in-before but of rating 200 Amps.
M&L cross arms, supports, clamps etc fabricated from structural steel sections including nuts, bolts, washers, welding, bending (cold or hot) drilling holes for bolts bent to any shape or size as indicated or directed inclusive of one primer coat of red oxide zinc chromate one under coat and one finishing coat of aluminium paint complete all as specified and as directed by Engineer-in-charge.
S&F pin type insulator, porcelain, vitreous white/ brown including one galvanised MS spindle nut and two GI washers of size 150 mm height, 150 mm dia for 11000 volts complete all as specified and directed by Engineer-in-Charge.
S&F single disc porcelain, vitreous white/ brown insulator 255 mm dia and 145 mm height assembly for tension with tension clamps for conductor working pressure 11000 volts complete all as specified and directed by Engineer-in-Charge.
S&F lightening arrestors, expulsion type complete with all fittings, transmission class, discharge capacity 65 KA 11000 volts complete all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 Metre deep below ground level) with top edge of the plate not less than 1.5 Metre below normal ground level, connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 3 of SSR Part-I 2009 connected to earthing test point panel all as specified or indicated and testing on completion as directed by the Engineer-in-Charge including necessary excavation & earth work in any type of soil, funnel, PCC chamber (1 : 3 : 6) type C-1, CI pit cover and frame, charcoal, salt including earth lead protected by 40 mm dia 'light grade' GI pipe and 20 mm dia 'medium grade' GI Pipe for watering complete all as specified and directed by Engineer-in-Charge.
Note :- Earth lead wire 4.00 mm and GI 40 mm dia protecion pipe upto 7.5 mtr length will be deemed to include in the unit rate quoted.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 Metre deep below ground level) with top edge of the plate not less than 1.5 Metre below normal ground level, connected to galvanised earth lead strip 32 x 6 mm dia by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 3 of SSR Part-I 2009 connected to earthing test point panel all as specified or indicated and testing on completion as directed by the Engineer-in-Charge including necessary excavation & earth work in any type of soil, funnel, PCC chamber (1 : 3 : 6) type C-1, CI pit cover and frame, charcoal, salt including earth lead protected by 40 mm dia 'light grade' GI pipe and 20 mm dia 'medium grade' GI Pipe for watering complete all as specified and directed by Engineer-in-Charge.
Note :- Earth lead strip 32 x 6 mm and GI 40 mm dia protecion pipe upto 7.5 mtr length will be deemed to include in the unit rate quoted.
M&L for shifting of transformers of any capacity upto 400 kVA with the help of hydra/ crane including disconnecting the power cables from both HT and LT sides by availing proper shutdown from relevant authority, shifting the transformer on another location (distance not exceeding 50 metres) on 4 pole structure/ plinth/ platform including making necessary electrical connections complete all as specified and directed by Engineer-in-Charge.
shiv shanker enterprises (BID ID -3310104)
R D Bansal (BID ID -3310152)
Shree Balaji Construction (BID ID -3309600)
V r traders (BID ID -3309063)
UNITED ENGINEERING CORPORATION (BID ID -3310108)
Raman Electric Trading Co (BID ID -3308794)
MAHESH KUMAR SINGLA CONTRACTOR (BID ID -3310005)
M/S BALWINDER SINGH (BID ID -3304924)
MICKY CONSTRUCTION PVT LTD (BID ID -3309223)
GEPS PROJECTS (BID ID -3309085)
DIVYA ELECTRIC CORPOORATION (BID ID -3309194)
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .