Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.6 LAccepted-AOC 0 NEAR SHIV MANDIR KALYANIPURA KRIPAL NAGAR AJMER RAJASTHAN 305001 UDYAM RJ 01 0091182 | AJMER | RAJASTHAN | 305001 | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹13.9 L+₹91,094.95 (7.01%)Rejected-Finance PLOT NO 14 SHIV COLONY KATI GHATI RAJGARH ROAD ALWER RAJ | ALWAR | ALWAR | RAJASTHAN | L2 | Rejected-Finance Rejected being L2 |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
7 Oct 2020, 6:00 pmClosed
CWE A Jaisalmer
CWE A Jaisalmer
REPAIR AND MAINT OF HT UG CABLE/OH LINE,TRANSFORMER, VOLTAGE STABLIZER AND ALLIED WORKS AT ASCON NODES AND DABLA IN CERTAIN AREA UNDER GE (A) JAISALMER
2020_MES_361048_3
83843
Open Tender
Electrical and Maintenance Works
Works
180 days
GE A Jaisalmer
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE(A) JAISALMER
₹20,000
Yes
18 Jan 2021
8 Sept 2020
9 Oct 2020
8 Sept 2020
7 Oct 2020
23 Sept 2020
Amount
Note : The location for execution of work will be Escon Nodes at Gemnewala, Sanu, Danwar, Sangarh, Rannautar, Mohangarh and Dabla area, Rates to be quotated by the contractor considering the distance locations. Please note that nothing extra shall be paid on account of this.
Taking down and dismounting defective transformer 11/0.433 KV of capacity 25 KVA to 63 KVA from foundation/ pole by using crane and transporting to workshop or factory at Jodhpur fo repair after disconnecting HV side HT cable or HT aluminium conductor and LV side LT cable , dismantling the same for repair & renewal of unserviceable parts and reassembling complete ,spray painting with two coats of synthetic enamelled grey paint after preparation of old surface writing MES No with white paint of suitable size letter and transporting back from workshop Jodhpur to site, installation on plate form/pole, testing & commissioning to entire satisfaction of Engineer-in-Charge.
Taking down and dismounting defective transformer 11/0.433 KV of capacity 75 KVA to 160 KVA from foundation/ pole by using crane and transporting to workshop or factory at Jodhpur for repair after disconnecting HV side HT cable or HT aluminium conductor and LV side LT cable , dismantling the same for repair & renewal of unserviceable parts and reassembling complete, spray painting with two coats of synthetic enamelled grey paint after preparation of old surface writing MES No with white paint of suitable size letter and transporting back from workshop Jodhpur to site, installation on plate form/pole, testing & commissioning to entire satisfaction of Engineer-In-Charge.
Taking down and dismounting defective transformer 11/0.433 KV of capacity 160 KVA to 250 KVA from foundation/ pole by using crane and transporting to workshop or factory at Jodhpur for repair after disconnecting HV side HT cable or HT aluminium conductor, LV side, LT cable dismantling the same for repair & renewal of unserviceable parts and reassembling complete, spray painting with two coats of synthetic enamelled grey paint after preparation of old surface writing MES NO with white paint of suitable size letter and transporting back from workshop Jodhpur to site, installation on plate form/pole, testing & commissioning to entire satisfaction of Engineer-In-Charge. NOTE FOR SER ITEM NO.2 TO 4 :- Spare parts ie, transformer oil, copper winding wire for rewinding will be measured and paid separately under supply only.
Supply and Fixing in repair Synthetic rubberised gaskets for top cover of transformer for the following :-
11/0.433 KV 25 KVA to 160 KVA capacity complete.
11/0.433 KV 200 KVA to 250 KVA capacity complete.
Supply and Fixing in repair Synthetic rubberised gaskets for HT bushing of transformer for the following :-
11/0.433 KV 25 KVA to 160 KVA capacity complete.
11/0.433 KV 200 KVA to 250 KVA capacity complete.
Supply and Fixing in repair Synthetic rubberised gaskets for LT bushing of transformer for the following :-
11/0.433 KV 25 KVA to 160 KVA capacity complete.
11/0.433 KV 200 KVA to 250 KVA capacity complete.
M&L for taking out unserviceable core and limb and HT/LV winding of transformer and taking out burnt copper winding wire cleaning carefully an rewinding the same with new superior quality 99.99% pure copper enamelled wire as per existing gauge including insulating material for transformer 25 KVA to 250 KVA complete all as specified & directed by Engineer-in - Charge.
Supply and Fixing in repair of transformer oil of dielectric strength 50 KV minimum for voltage stablizer, transformer, CTs 33 KV and PTs 33 KV outdoor type factory sealed with test certificate complete all as specified & directed by Engineer-in - Charge.Make: Savita, Servo, Power Oil.
Dehydration of transformer oil (mounted on poles/platform etc) with the help of filtering and drying plant by mechanical machines of suitable capacity to achieve dielectric strength of 50 KV complete all as specified and directed by Engineer-in-Charge.(Note : For any capacity of Transformer)
M&L in repair of unserviceable HT brass stem of transformer 63 KVA to 250 KVA complete all as specified & directed by Engineer-in - Charge.
M&L in repair of unserviceable LT brass Stem with nuts, washers of transformer 11/0.433 KV of capacity 25 KVA to 160 KVA complete all as specified & directed by Engineer-in - Charge.
M&L in repair of unserviceable LT brass Stem with nuts, washers of transformer 11/0.433 KV of capacity 160 KVA to 250 KVA complete all as specified & directed by Engineer-in - Charge.
M&L in repair of unserviceable breather assembly with new silica gel of transformer 11/0.433 KV of capacity 63 KVA to 160 KVA complete all as specified & directed by Engineer-in - Charge.
M&Lin reapir of unserviceable breather assembly with silica gel of transformer 11/0.433 KV of capacity 160 KVA to 250 KVA complete all as specified & directed by Engineer-in - Charge.
Supply & Fixing in repair of winding temprature indication gauge anlog type complete suitable for transformer 11 KV, 11/0.433 KV complete all as specified & directed by Engineer-in - Charge. (Make:- PRECIMEASURE CONTROLS Model No. 1031).
Supply & renewal of porcelain transformer bushing 1.1 KV suitable for transformer upto 250 KVA complete all as specified & directed by Engineer-in - Charge. (Make: Jayshree, Jaipuria Brothers)
Supply & renewal on load tap changer suitable for 11 KV transformer of capacity upto 250 KVA complete all as specified & directed by Engineer-in - Charge.
S & F in repair dimmer suitable for voltage stablizer 75 KVA (3x25) complete all as specified and directed by Engineer-in-charge. (Make:- Digitec).
S & F in repair servo motor 3 Kg / Sqcm suitable for voltage stablizer 75 KVA (3x25) complete all as specified and directed by Engineer-in-charge. (Make :- Apple, Stepsyn).
S&F main transformer suitable for voltage stablizer 75 KVA (3x25) voltage stabilizer complete all as specified and directed by Engineer-in-charge.
S & F in repair PCB suitable for voltage stablizer 75 KVA (3x25) complete all as specified and directed by Engineer-in-charge. (Make:- Digitec).
Supply, Jointing and testing indoor type cable termination heat shrinkable joint kit 11 KV Unearthed grade suitable for size 50 Sqmm to 95 Sqmm 3 core 11 KV under ground XLPE cable complete all as directed by Engineer-in-Charge.
Supply, Jointing and testing outdoor type cable termination heat shrinkable joint kit 11 KV Unearthed grade suitable for size 50 Sqmm to 95 Sqmm 3 core 11 KV under ground XLPE cable complete all as directed by Engineer-in-Charge.
Supply jointing and testing straight through heat shrinkable joint kit 11 KV Unearthed grade suitable for size 50 Sqmm to 95 Sqmm 3 core 11 KV under ground XLPE cable complete all as directed by Engineer-in-Charge.
S&F GI pipe light grade of dia 80 mm laying in road and along with poles for cable protection complete including taking down old pipe all as directed by Engineer-in-charge
Supply, installation, testing and commissioning of lightening arrestors (station type) out door type discharge current 10 KA assembly suitable for 12 KV including all clamps, nuts, bolts and washers and connection to earth with 32x6mm GI strip and including taking down existing lightening arrestors complete all as specified & directed by Engineer-in-charge.
Material and labour for switch air break gang operated triple pole mechanically operated, mounted on HT insulators (12 insulators vertical type operated) and MS galvanized steel frame with operating mechanism worked from ground level including operating rod for current rating up to 200 Amps 11000 volts complete with locking arrangement MS clamps, bolts and nuts and washers etc also including drop out expulsion type of fuses with fuse barrels of required capacity to suit load at site including two coats of aluminum paint over a coat of red oxide primer on MS work and including taking down old switch air break gang operated complete all as specified. (stack for fixing with poles shall be measure and paid separately)
Material and labour for switch air break gang operated triple pole mechanically operated, mounted on HT insulators (09 insulators horizental type operated) and MS galvanized steel frame with operating mechanism worked from ground level including operating rod for current rating up to 200 Amps 11000 volts complete with locking arrangement MS clamps, bolts and nuts and washers etc also including drop out expulsion type of fuses with fuse barrels of required capacity to suit load at site including two coats of aluminum paint over a coat of red oxide primer on MS work and including taking down old switch air break gang operated complete all as specified. (stack for fixing with poles shall be measure and paid separately)
S&F in repair, pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified & directed by Engineer-in-charge.
S&F in repair, disc type insulator, porcelain, vitreous, 145mm high and 255mm dia ball and socket type, white, brown or green, single disc assembly for 33000 volts grade complete all as specified & directed by Engineer-in-charge.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 Sqmm.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc not exceeding 10 sqm on plan and getting out in Soft/disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming excavated Soft/Disintegrated rock in layers all as specified & directed at site.
Removing excavated Soft/Disintegrated rock to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed by Engineer-in-Charge.
M&L for sand cushioning to underground PVC/XLPE cable with tibba sand and punning to provide required cover complete all as directed by Engineer-in-charge. (Note :- For the purpose of payment only punned thickness will be measured).
Supplying and laying Jodhpur stone quarry faced stone slab cover 25 to 30 cm in width, 50 to 60 cm long and 40 to 50 mm thick, laid dry and abutting each other with gap between adjacent slab not exceeding 10 mm over under ground cables for protection complete all as specified & directed by Engineer-in-charge.
Dismantling, taking down and removing the old existing unsv non-functional/broken hinges of any description and in any postiion of existing feeder piller boxes/panel boards/feeder pillar boxes etc and supplying and fixing new cold rolled 100mm long medium weight mild steel but hines in position with necessary spot welding etc including making necessary adjustment for free and smooth movement of panel and locking arrangments complete all as specified and directed by Engineer-in-Charge.
Taking down or removing of rusted body part/panel door existing LT Panel feeder pillar box of any size and shap, supply, fixing and febrication in existing, shap and size with and including 2 mm thick CRCA sheet and all jointing material such as nuts, bolts or washer and welding etc.
NOTE : (i) The panel board repaired shall be made totally enclosed, weather proof/wemin proof for installing incoming/outgoing MCCB/Switch fuses/cable etc complete all as directed.
(ii) The rates quoted by the contractor are deemed to be with and including necessary cutting, welding, levelling and jointing etc. as directed to match & accommodate with the existing feeder pillar box/panel board.
(iii) The replaced porting shall be painted with two coat of synthetic enamled paint over a coat of red oxide primer.
(iv) The rates quoted by the contractor deemed to be with and including dismantling/taking out/removing carefully, any damaed part/portion of the feeder pillar box/panel board as directed.
Preparation of the old decorated existing external and internal steel surfaces fo feeder pillar boxes/panels/boards of any description and in any position including removal of disintegrated & deteriorated paint either by hand scrpping or by blow stopping as required and applying tow coats of synthetic enameled paint (grey in colour) with using spray machine on old prepared surfaces complete all as specified and directed by Engineer-in-Charge.
Shifting of transformer of any capacity from Jaisalmer to new locations (Ascon Nodes & Dabla) and back to Jaisalmer with all required T&P/Hydera including connections, testing etc complete all as directed by Engr-in-Charge.
M/s Yash Electrical and Maintenance
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .