Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC RZ 212F D BLOCK RAJ NAGAR PART II PALAM COLONY NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | L1 | Accepted-AOC being lowest | |
| 2 | L2₹15.4 L+₹2,508 (0.16%)Rejected-Finance | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹17.7 L+₹2.4 L (15.7%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹17.9 L+₹2.5 L (16.6%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L4 | Rejected-Finance Being not lowest | |
| 5 | L5₹18.3 L+₹3.0 L (19.3%)Rejected-Finance | L5 | Rejected-Finance Being not lowest |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
27 Oct 2020, 6:00 pmClosed
MR ARJUN PATRO
GE U ELECTRIC SUPPLY DELHI CANTT-10
Repair Replacement of defected MCCB ACB LT Panel cable termination pole painting feeder piller LT earthing pole box of Signal enclave Sanjay Vihar APS Coloney SFC CGDA USI AWWA 1 CBPO 5 Signal Gp Asmare Line Varuna Naval Mess in the area of AGE U Ele
2020_MES_365704_1
GE ELECT/D-77/2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE U ELECTRIC SUPPLY DELHI CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE U ELECTRIC SUPPLY
₹60,000
Yes
21 Dec 2020
30 Sept 2020
29 Oct 2020
1 Oct 2020
27 Oct 2020
15 Oct 2020
Amount
M&L for painting on steel tubular pole of any Type any height( single swan neck/Straight pole) for street light fittings including GI pipe/brakets fixed on poles, by applying aluminium two coats of synthetic enamel paint aluminium colour, after cleaning the surface properly with sand paper, making strip with sythetic enamel paint with yellow/black/ white colour (road signal paint of the required breadth as directed at site up to 1.5 mtr height from ground level, writing numbers and letters of requred size as directed at site above 1.5 mtr height from ground level all as directed by Engineer-in-charge.
S&F in replacement ,PVC insulated sheathed stranded copper conductor single core cable 2.5 Sqmm size from KIOSK BOX to street light fittings. Note:- Two run of cable will be measured as one unit length.
Supply and fixing KIOSK box weather proof made out of PVC make : Sintax or equivalent in universal made out of one piece mounted SMC base and door, pole mounted hinged door size 333 mm x 23mmx120 mm outside and 300 mm x 200mmx105 mm inside dimensions with top hung shutter comprising of aluminium bus bar 4 strips 3 phase and neutral 63 Amps and one 6 Amps MCB SP for control the light fitting including two numbers F1 clamps 30x4 mm with necessary MS nut,bolt and washer including embossing/painting convention skull and bones in red signal colour on front face of KISOK box.
Dismantling the existing corroded/damaged LT pannel/feeder pillar boxes of any size by disconnecting all the incoming / out going cables, sealing the cable ends, disconnecting incoming / out going MCCB's from bus bar chamber and removing all the items
Labour and T&P only for Taking out LT cable loop of any size by execavation and taking out all material as required for connecting of cable to new LT panel including relaying the remain cables in same trench after making connection and testing complete all as specified and directed.
Supply, installation, testing and commissioning LT panel board 415 volts, AC 3 phase, 50 Hz, factory made outdoor type, made up of 3.15mm and cubical component 1.6 mm CRCA sheet, MS angle iron 50x50x6 mm base, cable entry from bottom conforming to degree of protection IP-65 . Gasketing ensuring IP protection, with powder coating and locking arrangements, LT panel mounted on PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) to cover the entire area of panel board, 15 cm deep in ground and 5 cm above ground minimum, with cable alloys. The LT panel shall be seprate chamber for bus bar, switch gear and cable entry/end connectio duly prewired with proper spacing to accommodate to all accessories, cable connection with suitable size of lugs/thimbles comprising of the followings :- (a) Aluminium bus bar 3 phase and neutral 600 Amps ,415 volts, fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 01 Set. (b) MCCB, 04 Pole, 400 Amps, with breaking capacity 35 KA at 415 volts microproccer release, adjustable type - 01 No, (In comming) (c) MCCB, 03 Pole, 100 Amps, with breaking capacity 25 KA at 415 volts Adjustable type - 06 No, (Out going) (d) Indication lamps R,Y,B LED type with 3 Nos of 5 A MCB SP – 1 set. (e) Digital Amp and volt meter AC. NOTE : (i) All MCCBs should have Ice 100% Ics . (ii) Location : APS colony (iii) Location cantnot be changed without permission of GE, approval of GE is mandetory for any changing in Location
Supply, installation, testing and commissioning LT panel board 415 volts, AC 3 phase, 50 Hz, factory made outdoor type, made up of 3.15mm and cubical component 1.6 mm CRCA sheet, MS angle iron 50x50x6 mm base, cable entry from bottom conforming to degree of protection IP-65 . Gasketing ensuring IP protection, with powder coating and locking arrangements, LT panel mounted on PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) to cover the entire area of panel board, 15 cm deep in ground and 5 cm above ground minimum, with five cable alloys ( up to 500 mm incoming/outgoing). The LT panel shall be seprate chamber for bus bar, prewired with proper spacing to accommodate to all accessories, cable connection with suitable size of lugs/thimbles comprising of the followings :- (a) Aluminium bus bar 3 phase and neutral 400 Amps ,415 volts, fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 01 Set. (b) MCCB, 04 Pole, 250 Amps, with breaking capacity 35 KA at 415 volts Adjustable type - 01 No, (In comming) (c) MCCB, 03 Pole, 100 Amps, with breaking capacity 25 KA at 415 volts Adjustable type - 04 No, (Out going) (d) Indication lamps R,Y,B LED type with 3 Nos of 5A MCB SP – 1 set. (e) Digital Amp and volt meter AC. Note: (i) Location : Sanjay Vihar, 1 CBPO and Asmera line (ii) Location cantnot be changed without permission of GE, approval of GE is mandetory for any changing in Location
M&L for painting on old surfaces LT panel of size 2 to 4 Sqm by spray paint after cleaning strains and grease/oil spots with sand paper & thinner and painting the cleaned surface with synthetic enamel paint (light gray) shade No-631 to achieve good finish by applying two coats of paints by spray painting machine crefully after disconnection of power supply and covering the meters, indicators and switches to prevent from fall of paint drop on them and including writing number, letter etc with white paint on newly painted surfaces
All as per item No 9 above but of size 5 to 10 Sqm.
Disconnecting the existing unserveceable/burntACB/ MCCB from the cable taking out from panel board & supply & fix new Air circuit breaker 4pole 415 volt manual draout type with microprocessor release , overload protection microprocesser release of capacity 800 Amp 50 KA breaking capacity Adjustable type suitable for 415 volts,50HZ 3 Phase supply fixed in existing panel including modification of existing frame and panel board door for proper installation of ACB andconnecting with existing cable including thimble,nut bolt and washers etc complete.
Disconnecting the existing unserveceable/burnt MCCB from the cable taking out from panel board & supply & fix new MCCB,3pole 400 Amp 35 KA breaking capacity Adjustable type suitable for 415 volts,50HZ 3 Phase supply thermal magnetic release, fixed in existing panel including modification of existing frame and panel board door for proper installation of MCCB andconnecting with existing cable including thimble,nut bolt and washers etc complete.
All as per item No 11 above but MCCB of rating 250 Amp 25 KA breaking capacity 3 pole
All as per item No 11 above but MCCB of rating 200 Amp 25 KA breaking capacity 3 pole
All as per item No 11 above but MCCB of rating 125 Amp 25 KA breaking capacity 3 pole
All as per item No 11 above but MCCB of rating 100 Amp 25 KA breaking capacity 3 pole
S &F fire retardant/extinguishing electric insulated synthetic mat Insulatica - 2000 of 2.5 mm thick + 10% confirming to BIS : DOC No ET-02(5440) dated 30 Apr 2004, meeting requirement of IS-3043,IS-5216 (Part -I,II &II), IS-8437 and IEC-479 pub-I,tested for breakdiwn strength, tensile/Elongation ageing properties,insulation resistance , effect of acid, alkaline, diesel and transformer oil leakage current test, fire test etc, having minimum width of 1000mm + 20mm including all allied materials such as PU-Resin, chemical bound (Haedener) special PVC adhesive liquid primer etc of required quantity to complete the job as per site requirement of all voltages not exceeding 11 KV system without HT trolley movement.
Supply jointing and testing straight through, heat shrinkable jointkit suitable for PVC/ XLPE insulated armoured heavy duty aluminium conductor 1100 volt grade of size 4 core,10 Sqmm and including taking from faulty portion in any situation/position complete all as directed.
All as per srl item No 18 here -in-before but size of 3.5 core, 25 to 50 Sqmm.
All as per srl item No 18 here -in-before but size of 3.5 core, 70 to 120 Sqmm.
All as per srl item No 18 here -in-before but size of 3.5 core, 185 to 300 Sqmm.
Disconnecting of all electric connection from the existing unserviceable/burnt ACB 800/1000 A four pole 415 Amps and dismantling/taking out ACB from LT panel board for repair at site including servicing and re assembling the ACBs after repair reconnecting of all connection including replacement of following parts of ACB for working as satisfication level complete all as specified and directed.
Supply and fix in replacement pole connector 800/1000 Amps 415 volts
Supply and fix in replacement Jaw contact 800/1000Amps 415 volts
Supply and fix in replacement Fixed contact 800/1000 Amps 415 volts
Supply and fix in replacement Hard ware Kit 800/1000 Amps 415 volts
Supply and fix in replacement moving contact 800/1000Amps 415 volts
Supply and fix in replacement Trip coil 220 volts
Taking down carefully copper/aluminium point wiring (light, fan , socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendent, regulators light fittingsocket, removing materials to store for keeping in safe custody or for re use for taking credit (Credit for above items should be made as per conditions seperatly) and making good disturbed surfaces or wall floor etc.
Taking down MCB DB with MCB any type and capacity as directed by EIC
Taking down sub main wiring any type and any capacity all as directed by EIC
M&L for point wiring complete with 1.5 sqmm single core multi stranded FRLS Copper conductor PVC insulated and unsheathed 650/1100 volt grade drawn through and including PVC Casing & Caping fixed on wall incl terminal Box suitable for mounting of modular type switches, socket , regulator etc incl 1.5 sqmm PVC insulated FRLS copper multi stranded copper conductor used as earth wire and making good disturbed surface of wall /floor etc .
All as pe item no. 32 above but for One light point controlled by one switch 5 amp one way
All as pe item no. 32 above but for One fan point controlled by one switch 6 amp one way
All as pe item no. 32 above but for 6 amps socket on independent board
All as pe item no. 32 above but for 6 amp socket on same board
All as pe item no. 32 above but for 16 Amps socket point on independent board with 2.5 sqmm PVC insulated FRLS copper conductor with 1.5 sqmm PVC insulated FRLS copper conductor as earth wire.
S&F and connecting switch modular type 6 Amp flush type single pole one way with ISI marked.
M&L for modular type socket outlets 6 Amps 3 pin 230 V AC 2 module.
M&L for modular type socket outlets 2 in 1, 6/16 amps 230 V AC 2 modul.
M&L for MCB DB SPN 8 way IP-54 double door fixed on wall IP 54 protection with MCB SPN ‘C’ Curve type 40 amps 01 No and MCB SP ‘C’ Curve type 6 to 32 amps 06 Nos including necessary connection lugging with copper lugs pin/Ring type making good disturbed surfaces to match with existing surface / wall .
M&L for MCB DB SPN 4 way IP-54 double door fixed on wall ,IP 54 protection with MCB SPN ‘C’ Curve type 40 amps 01 No and MCB SP ‘C’ Curve type 6 to 32 amps 02 Nos including necessary connection lugging with copper lugs pin/Ring type making good disturbed surfaces to match with existing surface / wall .
Supply and fixing fan step regulator 120w 2 module Make:- Legrand/Hitechi/ABB
S&F Round type surface mounting LED luminaries integral high power LED, done shape opal diffuser provides good quality glare free light 12 watt AC 230 volts 50 Hz including connecting up with twin core twisted flexible copper conductor cable complete. Make : Philips/Wippro/Havells.
M&L for sub main wiring with two single core PVC insulated multi stranded copper conductor cable of size 4 sqmm 650/1100 volt grade (ISI marked ) drawn through in and including PVC heavy duty 25 mm bore conduit concealed in OR fixed on wall & conduit accessories thickness should not be less than 1.8 mm fixing in wall with clamps with 2.5 sqmm single core multi stranded copper conductor as earth continuity to common earth duly as earth wire . Note : Two run of wire and one run of wire & conduit will be measured and paid as one length
Demolition of PCC from path any position and M&L for PCC in foundation filling and mass concrete type C2 (1:4:8) using 40 mm grded stone aggregate for foundation of pole complete all as specified
M& L for PCC type B1 (1:2:4) using 20 mm graded aggregate for pedestal of poles including use and waste of formwork complete all as specified
M & L Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25m depth below ground level) with top edge of the plate not less than 1.5m below ground level connected to galvanisediron strip 25mm x 3 mm by mean of bolt, nuts, check nuts and washer of galvanised iron steel as as shown in electrical plate No 5 of SSR Part - I, connected to earthing test point and testing on complete all as specified and directed Note :- Rate also include necessary excavation and earth work in any type of soil, PCC pit 1:3:6 type C2, RCC cover, funnel with watering pipe20 mm GI light grade wire mess GI Protection pipe 40mm dia meduiam grade test point, connecting lead/strip from test point to main switch or eqipment to be connected including charcoal dust and salt.
M&L for repair and rewinding of three phase high mast tower motor 440 volts AC 1 HP 1425 RPM including dismantling from high mask, transportation to wksp for repair, rewinding of motor with existing size of super enamle copper wire, replacing of gear, bearing,bush greasing warneshing etc, replacement of wire rope dog clamp for running of wire rope at satisfactory level and re-installation complete all as specified and directed.
Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Eng-in-charge
Rajindera Enterprises
M/s Adhikari construction co.
Vijay Electricals
Microsys Controls India
IK ONKAR ENGINEER AND CONTRACTOR
Buddham Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .