Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 CrAdmitted-Finance | ₹3.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹3.3 Cr+₹2.8 L (0.87%)Admitted-Finance | ₹3.3 Cr+₹2.8 L (0.87%) | L2 | Admitted-Finance |
| 3 | L3₹3.4 Cr+₹16.8 L (5.18%)Admitted-Finance | ₹3.4 Cr+₹16.8 L (5.18%) | L3 | Admitted-Finance |
| 4 | L4₹3.7 Cr+₹46.5 L (14.4%)Admitted-Finance ROMA BANJARA TANDA CHS BUILDING NO 1 ROOM NO 506 MANKHURD W MUMBAI 400 043 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400043 | ₹3.7 Cr+₹46.5 L (14.4%) | L4 | Admitted-Finance |
| 5 | L5₹3.8 Cr+₹59.7 L (18.4%)Admitted-Finance | ₹3.8 Cr+₹59.7 L (18.4%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | PIYUSH ENTERPRISES L6 | RAJSHREE CONSTRUCTION CONSORTIUM L3 | arcoma L7 | B G CONSTRUCTIONS L1 | SUNIL CONSTRUCTION L4 | kamal enterprises L5 | Pawan Construction Company L8 | ask enterprises L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Excavation in all kinds of soil, wet or dry (such as yellow murrum, hard murrum/gravel or mixture of any kind, etc.), in loose and slushy condition, including soft rock, to the required level by mechanical equipment (JCB / Poclain) for foundation trenches, rafts of walls, plinths, including carting away and disposing off surplus excavated material (at locations approved by EIC) as directed by EIC including removal of vegetation, shrubs and debris, spreading, levelling, watering and compacting in layer not exceeding 150mm in depth in each layer and stacking of excavated material for back filling within the premises; if required, dewatering by bailing/pumping out water to keep the site dry at all times, making temporary stepping / sloping, shoring with planking, strutting, sectioning, trimming, dressing of sides, levelling or grading, cleaning, removing and excavating loose pockets and consolidating them by backfilling as directed by the EIC. Further Rate shall include manual excavation and final dressing to arrive at required level. | |||||||||||
| 2.00Further include backfilling on completion of works with approved excavated soil in layers not exceeding 150mm thick each layer spreading, levelling, watering and rolling each layer with 8 tonne vibratory roller and at inaccessible places with vibratory compactor / suitable hand roller to achieve 95% proctor density at optimum moisture content etc all complete to entire satisfaction of EIC. Further providing and erecting necessary Barricading for excavated area to avoid any calamity and maintaining the same up to the Contract period including submitting drawings / details of barricading for prior approval of EIC. | |||||||||||
| 3.00 | Up to 1.50m depth from designated Existing Ground level. | 420 | Cum | 250 ₹1,05,000 | 315 ₹1,32,300 | 600 ₹2,52,000 | 190 ₹79,800 Lowest | 700 ₹2,94,000 | 300 ₹1,26,000 | 300 ₹1,26,000 | 250 ₹1,05,000 |
| 4.00 | 1.50m to 3.00m from designated Existing Ground level. | 365 | Cum | 380 ₹1,38,700 | 461 ₹1,68,265 | 900 ₹3,28,500 | 200 ₹73,000 | 700 ₹2,55,500 | 82 ₹29,930 Lowest | 325 ₹1,18,625 | 250 ₹91,250 |
| 5.00Excavation in hard rock / boulders (more than ½ Cum in size) by chiselling to required level for foundation, trenches, rafts, plinths, levelling area etc. upto required depth including disposing off excavated material at a location within site as per direction of the Engineer incharge by stacking or spreading compacting as per direction of Engineer incharge; if required dewatering by bailing / pumping out of water to keep site dry at all times until completion of backfilling; shoring, strutting, stepping, dressing, grading, cleaning, removing and excavating loose pockets and consolidating them by backfilling as directed by the Engineer incharge etc. all complete as detailed in specification and conforming to safety rules of authority from time to time. | |||||||||||
| 6.00 | 1.50 m to 3.00m from designated Existing Ground level. | 175 | Cum | 1,450 ₹2,53,750 | 1,259 ₹2,20,325 | 1,200 ₹2,10,000 | 550 ₹96,250 | 1,200 ₹2,10,000 | 1,000 ₹1,75,000 | 1,400 ₹2,45,000 | 425 ₹74,375 Lowest |
| 7.00Filling and banking in plinths, area levelling etc. in layers each not exceeding 200mm in depth, breaking clods, watering, compacting each layer with vibratory compactor and at inaccessible places with wooden/steel rammers to achieve 95% proctor density at optimum moisture content; dressing up embankments; if required, bailing/pumping out of water to keep site dry while back filling; costs includes conveyance of all materials, labour, machinery etc. complete as per direction of the Engineer incharge to his entire satisfaction. | |||||||||||
| 8.00 | With selected earth available at site OR IN ACTREC CAMPUS | 488 | Cum | 165 ₹80,520 | 168 ₹81,984 | 450 ₹2,19,600 | 150 ₹73,200 Lowest | 250 ₹1,22,000 | 800 ₹3,90,400 | 250 ₹1,22,000 | 200 ₹97,600 |
| 9.00 | Providing and laying Granular sub-base soling as directed using approved quality rubble stones including dewatering, hand packing of smaller size stones, filling balance voids with stone dust and to achieve 98% proctor density of compaction of the soling layer with mechanical vibratory compactor etc. complete including dewatering if required, complete to satisfaction of Engineer incharge. Material brought from outside. | 216 | Cum | 1,390 ₹3,00,240 | 2,391 ₹5,16,456 | 1,050 ₹2,26,800 | 350 ₹75,600 | 3,000 ₹6,48,000 | 2,205 ₹4,76,280 | 2,600 ₹5,61,600 | 300 ₹64,800 Lowest |
| 10.00 | Providing, diluting and injecting chemical emulsion for pre-constructional anti-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete. Work to be carried out as per IS : 6313 (Part II) and to the satisfaction of the Engineer incharge. (Plinth area of the building at ground floor only shall be measured for payment) | 400 | Sqm | 140 ₹56,000 | 151 ₹60,400 | 220 ₹88,000 | 100 ₹40,000 Lowest | 500 ₹2,00,000 | 167 ₹66,800 | 150 ₹60,000 | 150 ₹60,000 |
Tender Value
₹3.5 Cr
EMD Value
₹6.9 L
Closing Date
15 Dec 2023, 3:00 pmClosed
DIRECTOR TMC
Office of Engineering services, Second Floor,Khanolkar Shodhika , ACTREC Kharghar Node, Navi Mumbai - 410210
CONSTRUCTION OF IMMUNODEFICIENT ANIMAL RESEARCH FACILITY AT ACTREC, KHARGHAR, NAVI MUMBAI
2023_TMC_783191_1
ET-130/ ANIMAL RESEARCH FACILITY/ 2023
Open Tender
Civil Works
Item Rate
240 days
ACTREC-Kharghar
As Per Tender Document
2 documents required · 2 mandatory
₹0
₹6.9 L
Yes
ACTREC, KHARGHAR
3 May 2024
30 Nov 2023
18 Dec 2023
30 Nov 2023
15 Dec 2023
30 Nov 2023
30 Nov 2023 - 6 Dec 2023
7 Dec 2023
Amount
Excavation in all kinds of soil, wet or dry (such as yellow murrum, hard murrum/gravel or mixture of any kind, etc.), in loose and slushy condition, including soft rock, to the required level by mechanical equipment (JCB / Poclain) for foundation trenches, rafts of walls, plinths, including carting away and disposing off surplus excavated material (at locations approved by EIC) as directed by EIC including removal of vegetation, shrubs and debris, spreading, levelling, watering and compacting in layer not exceeding 150mm in depth in each layer and stacking of excavated material for back filling within the premises; if required, dewatering by bailing/pumping out water to keep the site dry at all times, making temporary stepping / sloping, shoring with planking, strutting, sectioning, trimming, dressing of sides, levelling or grading, cleaning, removing and excavating loose pockets and consolidating them by backfilling as directed by the EIC. Further Rate shall include manual excavation and final dressing to arrive at required level.
Further include backfilling on completion of works with approved excavated soil in layers not exceeding 150mm thick each layer spreading, levelling, watering and rolling each layer with 8 tonne vibratory roller and at inaccessible places with vibratory compactor / suitable hand roller to achieve 95% proctor density at optimum moisture content etc all complete to entire satisfaction of EIC. Further providing and erecting necessary Barricading for excavated area to avoid any calamity and maintaining the same up to the Contract period including submitting drawings / details of barricading for prior approval of EIC.
Up to 1.50m depth from designated Existing Ground level.
1.50m to 3.00m from designated Existing Ground level.
Excavation in hard rock / boulders (more than ½ Cum in size) by chiselling to required level for foundation, trenches, rafts, plinths, levelling area etc. upto required depth including disposing off excavated material at a location within site as per direction of the Engineer incharge by stacking or spreading compacting as per direction of Engineer incharge; if required dewatering by bailing / pumping out of water to keep site dry at all times until completion of backfilling; shoring, strutting, stepping, dressing, grading, cleaning, removing and excavating loose pockets and consolidating them by backfilling as directed by the Engineer incharge etc. all complete as detailed in specification and conforming to safety rules of authority from time to time.
1.50 m to 3.00m from designated Existing Ground level.
Filling and banking in plinths, area levelling etc. in layers each not exceeding 200mm in depth, breaking clods, watering, compacting each layer with vibratory compactor and at inaccessible places with wooden/steel rammers to achieve 95% proctor density at optimum moisture content; dressing up embankments; if required, bailing/pumping out of water to keep site dry while back filling; costs includes conveyance of all materials, labour, machinery etc. complete as per direction of the Engineer incharge to his entire satisfaction.
Providing and laying Granular sub-base soling as directed using approved quality rubble stones including dewatering, hand packing of smaller size stones, filling balance voids with stone dust and to achieve 98% proctor density of compaction of the soling layer with mechanical vibratory compactor etc. complete including dewatering if required, complete to satisfaction of Engineer incharge. Material brought from outside.
Providing, diluting and injecting chemical emulsion for pre-constructional anti-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete. Work to be carried out as per IS : 6313 (Part II) and to the satisfaction of the Engineer incharge. (Plinth area of the building at ground floor only shall be measured for payment)
Providing and laying ready mixed M15 grade plain cement concrete (PCC) of required thickness for foundation, rafts, plinth beams, levelling course and all locations, etc. (minimum cementitious content shall be as specified in the IS Code and as approved); including compacting, curing, required shuttering and its removal, dewatering where required and vibrating, cleaning, preparing surfaces, junctions, etc.; complete at all depths and leads as per the drawing and to entire satisfaction of the site incharge / Engineer.
Providing, machine mixing and laying designed Ready mix M25 grade reinforced cement concrete (RCC) for column, slab, beam, walls, staircases etc. as listed below (and at any other elements not listed), using 20mm nominal size well-graded approved quality aggregate and M sand as per approved design mix as per IS code and with minimum cement content as per IS or as specified by Structural consultant, whichever is more; maximum water cement ratio 0.42 including using approved admixtures, vibrating / compacting, curing, scaffolding, cleaning, preparing surfaces, junctions, hacking closely surfaces to be plastered etc. complete but excluding the cost of Formwork and reinforcement to the entire satisfaction on of the Engineer incharge at all depths, heights, lifts and leads.
Providing, machine mixing and laying designed mix / Ready mix M30 grade reinforced cement concrete (RCC) for column, slab, beam, walls, staircases etc. as listed below (and at any other elements not listed), using 20mm nominal size well-graded approved quality aggregate and M sand as per approved design mix as per IS code and with minimum cement content as per IS or as specified by Structural consultant, whichever is more; maximum water cement ratio 0.42 including using approved admixtures, vibrating / compacting, curing, scaffolding, cleaning, preparing surfaces, junctions, hacking closely surfaces to be plastered etc. complete but excluding the cost of Formwork and reinforcement to the entire satisfaction of the Engineer incharge at all depths, heights, lifts and leads.
Footings / Raft Tie / Plinth Beams /Columns / Shear Wall / Lift Walls/RC Beams at all levels Lintel beams / Chajja FIRST FLOOR LEVEL /RC Slabs at all levels Staircase including steps FIRST FLOOR /equipment pedestal
Providing, fabricating, erecting and fixing in position water proof plywood centering and shuttering true to line and level, including required height's steel propping and staging, at all heights/levels, applying shuttering removal chemical emulsion/oil as approved, required bracing, if specified chamfering exposed edges, corners of beams, columns, walls etc., making leak proof joints etc. complete, at all leads and lift. Also include safely removing and dismantling the aforesaid assembly after specified or as approved period from the day of casting of concreting to the satisfaction of the Engineer incharge. The item shall also include the required staging and supporting arrangements. Soffit of slabs shall be fair face finished with no undulation of more than 2mm permitted. Any defect noticed shall be corrected by grinding or as approved by Engineer incharge, at Contractor's cost. The staging and formwork design shall be submitted to the Engineer incharge and got approval from Structural Consultant before proceeding to erect the same. Upto a Height of 6.5m
Note :- The form work and support for the contraction strips of (1m wide) as observed in structural drawings shall be mandatorily kept for the duration of 40 days in each floor. The rate shall be inclusive of the same and no extra shall be paid towards this.
Footings / Raft Tie / Plinth Beams
Columns / Shear Wall / Lift Walls
RC Beams at all levels Lintel beams / Chajja
RC Slabs at all levels Staircase including steps
equipment pedestal
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to two story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S.clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineering-charge .The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding.
Propping and supporting the structural members and its adjoining areas with steel props ( Adjustable or as Required), bracing, steel/timber runners etc to relive the structural member of the required load coming over it as per the pattern given by the contractor or approved by Engineer-in-Charge complete.
Steel Prop of up to 5 MT Capacity and up to 3.2 m height
Providing, transporting to site, storing, de-coiling (if required), straightening, cutting, bending, spirally hooping, binding and placing, in position reinforcement bars, to correct shape and size as per detailed drawings, specifications, preparing and getting approved bar-bending schedules for all reinforced concrete work such as walls, columns / stub columns, beams, slabs, staircase etc.; with correct size of heavy duty PVC / concrete (of same grade of concrete) cover blocks and galvanized binding wire of 18 gauge, couplers in place of laps permitted, required dewatering, provide required labour and machines / equipment / tools / tackles for handling, shifting, bending, binding, etc. The measurement shall be as per IS 1200. The rate shall include cost of concrete cover blocks, binding wire, all chairs, spacers and pins etc. all complete to the satisfaction of the Engineer incharge at all depths, height, lift & leads.
TMT HYSD bars - Fe-500 grade confirming to IS 1786.
Providing fixing M.S. (Class "C") sleeves of following sizes to correct line & level as per drawings within beams, slabs, walls, columns etc. Sleeves shall be duly sealed at ends with thermocol or any other material to make sure that no concrete enters & chocks the same during concreting. Also make clear that they are maintain to correct line & level during concreting, providing reinforcement around the sleeves as detail in the drawing.
Up to 50mm dia, Up to 150mm to 400mm length
Up to 80mm dia, Up to 150mm to 400mm length
Up to 100mm dia, Up to 150mm to 400mm length
Up to 150mm dia, Up to 250mm to 400mm length
Providing, fabricating and installing hot-dipped galvanized inserts in concrete in the form of mild steel angles, flats, plates, angle frames, sleeves as per details given by services consultants, etc. with anchors in the form of rods or flats including welding anchors, lifting hooks, rungs, templates etc., complete to correct line, level as shown in the drawings.
Providing, fabricating and installing foundation bolts for steel columns, equipment base frames, base plates - with M.S. threaded rods, anchor plate at the bottom and pipe sleeve to act as pocket, as per drawing. The installation of the group of bolts in a foundation shall be carried out using template specially fabricated as per the exact dimensions of the bolt layout.
Providing and fixing Puddle flanges of required sizes in RCC structures at locations and levels as shown on the drawing, fabricated MS hot dip galvanized finish pipes assembly with 150 mm wall thickness upto 65 mm nominal bore pipes and 6 mm wall thickness for 80mm or above diameter pipes welded to 5mm thick square plate of size 3 times the diameter of the pipe. Puddle flanges upto 50mm n.b shall have screwed ends whereas pipes of larger diameters shall be provided with flanges of approved sizes on both ends. Overall length of the puddle flange pipe shall be such that it will project 150mm/200mm on either side of the wall. The average length of the puddle flange shall be maximum 900 mm in length.
Providing, fixing, jointing and testing heavy duty, UPVC pipes, - 6 kg/cm2 pressure, of approved makes, open, low density, to wall, ceiling and floor, approved quality, complete, for plinth WALL drain pipes and discharge pipes from drain channel , sumps including jointing with rubbering / solvent / solution and airtight joints, with necessary specials, couplers, elbow, equal tees, tail piece, adapter (both male and female), reducer (single stage, double stage and triple stage), end cap, fabricated bend, etc., and lubricant or jointing material, including testing, cutting, making good the wall, ceiling and floor etc. complete of the following nominal bore (NB) size with Dual Check Backflow Preventers for piping from 15 mm to 75 mm dia:
Providing & fixing,32 mm dia heavy duty, PVC conduit pipes, of approved makes, to wall column and floor, approved quality, including all necessary fitting complete etc ,for compound wall column post to lay the electrical cable for light fixer power supply .
Drilling or Core cutting horizontal, vertical or inclined holes in reinforced cement concrete and / or hard rock of following sizes for a max depth of 300 mm depth / length at all levels and locations as per directions of the Engineer incharge.
Upto 25mm dia
Above 25mm to 50mm dia
Above 50mm to 75mm dia
Above 75mm to 100mm dia
Preparing shop drawings, obtaining Structural Consultant's approval, supplying, fabricating in accordance with IS:800, delivering at site, hoisting and fixing in position at all locations and levels, including all temporary staging and supporting work and making all steel framing work in accordance with the design, drawings prepared by the Consultants. The rate of steel work shall include cutting, grinding, machining, assembly, welding, jointing of single / built up new sections with anchors, angles, etc., cost of mechanical fasteners, nuts, bolts and washers, pre-heating, etc. Fabrication will involve connections using plates, channels and angles, gusset plate, foundation bolts, base plate, cleats, fasteners, stiffeners etc. as per drawing, steel conforming to IS : 226 and IS : 2062. Further rate shall also include one coat of zinc rich primer and two or more coats of synthetic enamel paint of approved make after properly cleaning the steel surface with wire brush and mild acid solution followed by washing with water and drying the surface completely, to be applied to individual fabricated parts of the structure prior to their erection & assembly in their final place. All complete as to entire satisfaction of the Engineer incharge.
ROOF DECKING :- Sheet approved manufacture: Supply and installing Roof sheet Trupan 60 mm thick of PUR 40 Kg/Me density both sides 0.50 mm PPGL RMP AZ 150 300 MPAwith RAL 9002, Sheet profile Trapezoidal and Micro-ribbed Trapezoidal profile pitch = 250 mm, Thickness= 35 mm , Core Thickness = 60 mm, Density = 40± 2 kg/m3, Compressive Strength ≥210 kpa, Adhesion Strength ≥100 kpa, Dimension Stability Overall Max. 2 %, Closed Cell Content 92-95%, Water absorption Max .2 % , Fire class B3-PUR , Self-Extinguishable , Polyisocyanurate foam HCFC, CFC, HFC free , Sound Reduction Index (dB) 25 , Cover Width Roof panel with 1000 mm , Maximum Panel Length 7.225 m with External interCoatings Weather Sheet 0.5mm TCT, AZ150, 550mpa, RMP/SMP coated PPGL . Internal Weather Sheet of approved manufacture All installation is to be carried out by approved trained roofing installer. The installation team shall be fully trained and approved by the manufacturer. The roof system manufacturer/supplier must have a registered office in India
Aluminium gutter of 2mm thickness with aluminium gutter expansion joints @ 12m.inluding all necessary hardware all complete etc as per direction of Engineer-in-charge.
Fabricating, supplying and fixing in position, M.S gratings / covers in hot dipped galvanizing 60 microns made up of 50 x 50 x 6mm thick MS angle and 40 x 5 MS flat at 15mm c/c etc as per specifications and drawings, including painting it with 3 coats of approved enamel paint, etc. complete, as directed.
Providing and fixing Kerb Stones of M25 grade form finished, well cured, free of any defect as per approved shape (batered / rounded at top), work include required excavation, consolidation, 75mm thick PCC 1:4:8 for bedding, required shuttering, jointing with cement mortar 1:6 and pointing with 1:2 cement mortar, curing the assembly, backfilling the surround to original with proper compaction, cleaning etc. Further including approved enamel painting in two coats or as approved of all complete to the entire satisfaction of the Engineer incharge. Size : 150mm wide
Providing and laying 400 micron thick polyvinyl chloride sheet in proper level where ever required as per instruction of Engineer incharge. (Ground floor below Trimix)
Providing and constructing AAC Light weight Block Masonry with 75mm/100mm/150mm/200mm/300mm thick at all levels in by using approved block laying polymer modified adhesive mortar or jointing compound recommended by the block manufacturer , including 75mm thick Patli / Stiffeners of M-15 Grade at approx. every 1000mm -1200mm with 2 nos 8mm steel bars all to be considered in the cost and no separate measurement will be done for steel and patli, also including scaffolding, racking out joints, curing with curing compound etc. in line, level and plumb, All complete as per specification for all height of floor or as directed etc. ( Rate includes the cost of stiffeners and steel ). (No holes for scaffolding will be permitted into the blockwork) ( Patli to be done for all the thickness of the blocks ) Work at all levels
Providing and constructing 200mm thick AAC block masonry (BILT or equivalent as approved), blocks conforming to IS 2185 (Part-III) masonry using approved ready-mix mortar (approved make) as per manufacture’s instruction complete with required raking out joints, curing, doing independent double legged scaffolding etc. as per specification at all heights, depths and leads to the satisfaction of the Engineer incharge.
Providing and constructing AAC concrete block masonry (approved make), blocks conforming to IS 2185 (Part-III) masonry using approved ready-mix mortar (approved make) as per manufacturer’s instruction, including providing RCC patli beam of 100mm at every 1.00m c/c with 2 nos. 8 mm dia Tor bars and 6 mm dia links at 300 c/c in cement concrete of mix M20, required formwork complete with raking out joints, curing, doing independent double legged scaffolding as per specifications etc. at heights, depths and leads as directed by Engineer incharge to his entire satisfaction. (Patli beam is part of the item)
a) 150mm thick wall
b) 100mm thick wall
Providing and applying 12mm thick plaster in cement mortar mix ratio CM 1:4 (1 cement : 4 sand) mixed with polypropylene fibers as per instruction of the approved manufacturer, to internal surfaces of concrete and masonry work; including raking out joints, hacking concrete surfaces and applying approved chemical bonding agent and applying a scratch coat over concrete surfaces by bonding / adhesive chemical coat as directed by approved manufacturer to create a key, cleaning / grooving deep junctions of concrete & masonry, grouting then back by mortar mixed with non shrinking compound along with packing of clean, fresh square cut aggregate; also providing and fixing 20 gauge GI chicken mesh @ 150 mm wide to junctions of concrete and masonry, preparing jambs, sills, grooves, pattas, wattas, rounding of corners, any circular works, ramps etc. all complete as per architectural drawings, specifications and finished smooth with wooden rundha etc. or as specified by the Engineer incharge at all leads, depth and lifts, doing independent double-legged scaffolding, cleaning of surfaces, curing, etc. complete as per specification and to the approval of the Engineer incharge.
Providing, preparing and plastering readymade proprietary Gypsum plaster to internal walls and ceilings average 13mm thick using Gyproc (universal) Elite plaster, wall surfaces of concrete, masonry work, including plaster mesh reinforcement of approved make and quality wherever required at junctions of masonry and concrete, doing jambs, sills, all types of groove as shown in the drawing, wattas, rounding of corners etc. all complete as per architectural drawing, specification and directed by Engineer incharge, at all lift, lead and depth, doing independent double legged scaffolding, making gypsum plaster mix as per approved manufacturer’s instruction, applying high grade polymer based bonding agent (Gyproc Bond IT) mixed with approved quality sand on RCC surfaces etc. complete as per manufacturer's specifications and approved by Engineer incharge. Plastering shall be to correct line, levels and plumb including curing, cleaning etc. complete to entire satisfaction of Engineer incharge.
Do as per Item No. 4.1 but to walls / ceilings of ducts and inside the boxing masonry including adding approved waterproofing compound 2% by weight of cement or as directed by the Engineer incharge to his entire satisfaction. (Ducts)
Providing and applying minimum 25mm thick double coat cement sand plaster; first coat to be 15mm thick cement sand mortar of mix ratio CM 1:4 (1 cement : 4 sand) including adding 2% by weight of cement approved waterproofing compound and polypropylene fibers as per recommendations of approved manufacturer, second coat to be 10mm thick in cement sand mortar of mix ratio CM 1:3 (1 cement : 3 sand) including adding polypropylene fibers as per recommendations of approved manufacturer, finished sand face or as required to receive specified architectural external finish to correct line, plumb and level to external faces of walls, soffits/ceiling if any, including hacking concrete surfaces then applying chemical adhesive coating and a scratch/dash coat as a positive bond, curing the same, racking out junctions of masonry and concrete, then pointing and grouting using non-shrinking compound, joints grouted by pressing square crushed stone, further providing 150mm wide 20 gauge GI chicken mesh at junctions of concrete and masonry work, doing independent double legged scaffolding etc. Item also include plastering to preparing and finishing window sills, RCC cornices, making wattas, drip-moulds, pattas, grooves etc., doing curing, cleaning etc. all complete to the approval of the Engineer incharge.
Forming groove of uniform size from 12 X12 mm upto 20 X15 mm in plastered surface as per approved pattern, using wooden battens nailed to the under layer, including removal of wooden batons, repair of the edges of plaster panel and finishing the groove etc. complete as per specification, drawing and the instructions of engineer in charge. ( FOR BUILDING EXTERNAL ELEVATION )
Supplying, laying and fixing of std. chicken wire mesh IRCS-6(6 x 6 x 6/6) in positions at junctions of concrete & masonry works etc. all complete as per specification, drawing and instructions of engineer in charge. ( FOR RCC AND WALL EXTERNAL JUNCTION AREAS )
Chemical waterproofing to Toilet & Sunk area. Designing, providing and laying proprietary chemical water proofing system consisting of polymer modified acrylic base composite coating (of one part or two part component) as approved by the Engineer incharge and as recommended by the approved manufacturer of waterproofing coating, sandwiched fibre mesh and protective screed. The work shall include cleaning of surface, grouting porous surfaces including making ‘V’ grooves at junctions, cracks etc. Further including horizontal surface protected with 20mm screeding in 1:4 mortar (1 cement : 4 M sand) and vertical surface (wall) plastered with cement, sand mortar in ratio 1:4 (1 cement : 4 M sand), finished in ready to receive Architectural finish, in correct line, level and plumb, curing, grouting, testing, etc. all complete to entire satisfaction of the Engineer incharge, contractor to provide guarantee for 10 years on appropriate value stamp paper in approved proforma.
i) Location : Toilets
ii) Location : Drain
Providing and filling with cement mortar mixed in ratio 1:3:6 (1 cement : 3 M sand : 6 brick bats) including mixing of water proofing compound 4 % by weight of cement. Further surfaces shall be screeded with (1:1.5:3) cement concrete mix with 4% by weight of cement approved waterproofing compound about 20-30mm thick and finished smooth or ready to receive finish material as specified. Care shall be taken prior to filling all pipes passing through sunk portion are pressure tested by maintaining pressure for 24 hours and junctions of pipes passing through walls, slabs are well grouted and sealed. This shall be tested by ponding water for 100mm thickness and maintaining for 72 hours.
LIFT PIT WATERPROOFING: Designing, providing, installing Membrane waterproofing system below RCC foundation / raft and on outside of RCC Lift pit / Retaining walls. System should follow progressive lifts of RCC lift pit wall and should create 100% water tight and chemical barrier around the structure. All complete to approval of Engineer incharge and system shall be guaranteed for 10 years on approved stamp paper. System recommended and specified are as under:
Horizontal surfaces : Clean the PCC concrete surface with brush. Remove sharp protrusion on the blinding layer by chipping and local repairs. If PCC top surface is wet/moist, the same shall be made dry by Hot air blow at site. Providing and loosely laying 1.8 mm thick non-reinforced HDPE membrane of approved manufacturer. The HDPE membranes shall be laid adjacent to each other with an overlap of at least 100mm. The two adjacent membrane sheets shall then be self-adhered with selvedge tapes / double sided tapes to each other as per approved manufacturer's specifications.
Vertical surfaces :The surface of retaining shall be cleaned, make free from dust, remove any sharp protrusion before applying treatment. Bituminous Primer as recommended by approved waterproofing membrane manufacturer, shall be applied on surface of retaining wall. The primer shall be allowed to become sticky until it is tacky then applied with 1.6mm thick SBS membrane with HDPE liner membrane of approved make. Adjacent sheet shall be adhered in similar manner with overlap of at least 100mm. The overlap joint shall be sealed as per manufacturer's specification. Membrane is covered upto 300 mm height above G.L and stuck the membrane into a groove cut into the concrete surface and seals the groove with a suitable bitumastic or liquid sealant. - Providing and laying dimpled protection board of 8mm thick over the membrane with lap of 100mm before backfilling.
Providing and laying water proofing including 0.23 mts. radius vata with waterdrip level to get proper slope in all position with thickness of 125 mm as directed with 5 years written guarantee, by laying 40 mm thick cement mortar 1:4 (1 cement : 4 fine sand ) after thoroughly cleaning the base slab and removing all the loose materials with wire brush, applying cement & waterproofing slurry evenly spread on slab and mixing water proofing materials in cement mortar in proportion as recommended by manufacture, laying brick bats after thoroughly soaked in water on layer of cement mortar, applying cement slurry on brick between @ 0.08 bag/smt. with mixing water proofing materials in proportion as recommended by the manufactures & finishing top with china mosaic tiles chips with 12 mm thick C.M. 1:3 base and laying by keeping gaps which should be filled with white cement and colour pigment including rounding or junction extending upto 15 cm along the wall, including curing etc. complete. Note : The measurement of this item shall be taken as that of the horizontal surface (length x width ) that is from inside of the parapet walls, thus, not considering the surface measurement of the rounded vatas. Terrace area
Providing and laying approved make quality, colour, design and shade fully homogeneous Vitrified tile (conforming IS 15622) flooring in pattern as detailed in drawing or as directed by the Engineer incharge. Tile to be bedded in cement sand mortar mix ratio 1:6 (1 cement : 6 sand) thickness as per detail drawing including cleaning and preparing the surface for bedding, spreading neat cement slurry by using minimum cement about 2 kg/sqm prior to bedding and spreading cement paste using minimum cement about 4.5 kg/sqm over bedding, joints to be cleaned and grouted with matching colour approved quality polymer based readymade compatible grout, curing, cleaning, protecting approved protection sheet till handing over etc. to required line, level, etc. all complete at all heights and leads to the entire satisfaction of the Engineer incharge. 600mm x 600mm size vitrified tile flooring.
Providing and laying approved make quality, colour, design and shade fully homogeneous Vitrified tile (conforming IS 15622) flooring in pattern as detailed in drawing or as directed by the Engineer incharge. Tiles fixed over well cured, prepared, cleaned concrete surface by using approved compatible tile adhesive (Bal or Laticrete or equivalent approved) to correct line, level and plumb, joints to be cleaned and grouted with matching colour approved quality polymer based readymade compatible grout, curing, cleaning, protecting approved protection sheet till handing over etc. to required line, level, etc. all complete at all heights and leads to the entire satisfaction of the Engineer incharge. but for 600mm x 600mm size industrial tile flooring. (Location : Store & Store room, pump room, Electrical AHU room)
Providing and laying polished Kota stone 18 mm to 20mm thk in flooring. Under bed shall average 30mm thk of 1 cement : 4 sand mortar by volume and brought to proper level. The kota stone slabs/tiles laid over under bed, pressed and tapped down with wooden mallet to the proper level, lifted and pressed again with thick cement slurry spread over the surface with fine joint finished including pigments, curing, grinding, granite polishing etc. all complete. (Over all laboratory room and passage area )
Providing and fixing 100mm high Tile (same tiles as that of flooring) skirting to walls/columns as shown in drawing or as directed by the Engineer incharge. Tiles fixed over plastered masonry / RCC surfaces by using approved compatible tile adhesive (Bal or Laticrete or equivalent approved) of required thickness to correct line, level and plumb. Joints are well cleaned and grouted with matching colour approved quality polymer based readymade grout and cured, cleaned and including finishing junction of plaster etc. all complete at all heights, lifts and leads to the entire satisfaction of the Engineer incharge.
i) 550mm x 450mm size kota skirting. (Location : staircase & rooms )
ii) Heavy duty anti skid vitrified tile skirting. (Location : Car wash equipment area)
Providing and fixing of approved make quality, colour, design and shade fully homogeneous Vitrified tile (confirming to IS 15622) dado to walls/columns, as shown in drawing or as directed by the Engineer incharge. Tile fixed with approved compatible adhesive (Bal or Laticrete or equivalent approved) over plaster to correct line, level and plumb. Joints are well cleaned and grouted with matching colour polymer based approved quality polymer based readymade grout and cured, cleaned, junctions with plaster finished smooth, etc. all complete at all heights and leads to the satisfaction of the Engineer incharge.
i) 600mm x 600mm size Vitrified tile dado. (Location : Gents, ladies Toilets, Janitors room, )
ii) 600mm x 600mm size Vitrified tile dado. (Location : Lift wall, Pantry)
Providing & Fixing polished GRANITE STONE in stair case riser & steps with half round moulding with groove on every steps as per drg. including cement mortar 1:3 & in cement slurry, including necessary filing joints in cement pigmented to approved shade. Also includes necessary edge polishing, champhering, moulding etc complete as per the direction of architect ( STAIRCASE 1 & 2 )
TREAD SIZE (1550mm *300mm )
RISER SIZE (1550 mm*165 mm )
TREAD SIZE (1800mm *300mm )
RISER SIZE (1800 mm*165 mm )
100mm high approved Granite stone skirting. (Location : Staircase)
Providing and fixing approved Granite stone jambs and soffit (in two steps) of shape and size of approved quality and colour with required moulding, chamfering / rounding edges, polishing etc. complete as per detailed drawing. Stone fixed with approved quality compatible adhesive ( approved make) back of stone to correct line, level and plumb. Joints well cleaned, grouted with matching colour approved quality polymer based ready-made grout and cured, polishing etc. Further to include required double legged independent scaffolding etc. all complete at all heights and lead to satisfaction of the Engineer incharge.
a) L shaped 100mm at front and 275mm inside lift jamb; Location: Lift opening
b) 230mm wide; Location: window sills (in 2 steps)
c) 100mm wide; Location: Toilet ledge wall sill
Providing and laying of 18mm thick machine cut, machine polished approved Black Granite stone Band / Threshold in pattern and size as detailed in drawing or as directed by the Engineer incharge. Stone to be bedded in cement sand mortar mix ratio 1:6 (1 cement : 6 sand) thickness as per detail drawing including cleaning and preparing the surface for bedding, spreading neat cement slurry by using minimum cement about 2 kg/sqm prior to bedding and spreading cement paste using minimum cement about 4.5 kg/sqm over bedding, joints to be cleaned and grouted with matching colour approved quality polymer based readymade compatible grout, curing, cleaning, protecting approved make protection sheet till handing over etc. to required line, level, etc. all complete at all heights and leads to the entire satisfaction of the Engineer incharge. i) 300mm wide (Location : Lift lobby)
Providing & applying 1.2 mm thk PU based flooring which includes FLORPRIME quality WB Primer Coat, POLYDECK BC PU based base coat, Aggregate 30 broadcast & POLYDECK SF solvent free PU coating in desired colour shade.. (Location : over all lab area )
P/A Line Marking Paint : Providing & Applying Line marking paint 100mm wide using Flowcrete PU material.
Providing & laying 60 mm thick Precast standard interlocking heavy duty, M 35 grade paving blocks set by hand over the sand bed about 50mm thick, including levelling the original ground, compacting with compactor before & after laying the blocks by spreading fine sand by hand operated compactor, cleaning the surface all complete. (Location : Footpath SURROUNDING ROAD AREA AND PARKING AREA )
A) Providing & laying 75 mm to 100mm wide POLYDECK LM High build Epoxy based line marking over the flooring ( Ground - 1st floor)
B) Providing & laying 150 mm wide POLYDECK LM High build Epoxy based line marking & top coat with FLORTHANE UV - UV stable polyurethane based coating over the flooring (Terrace floor)
Providing and fixing of 18mm thick machine cut, machine polished approved Granite stone of approved quality wash basin counter top about 600mm wide fixed and bedded over 30mm thick kaddapa stone and about 100mm wide mirror polished Granite fascia all as detailed in drawing. Stones for fascia fixed with epoxy adhesive; exposed faces / edges, rounded / chamfered, mirror polished etc. complete to the approval of the Engineer incharge. All junctions shall be sealed with silicon sealant. Further to include required MS framing, drilling, cutting of holes, SS pins, anchors, clamps, finishing junctions with plaster etc. complete to the entire satisfaction of the Engineer incharge. (Location : Toilets & sink area )
Providing and fixing of 20mm thick machine cut, machine polished approved Granite stone of approved quality service counter top about 800mm wide fixed in wall as detailed in drawing, exposed faces / edges, rounded / chamfered, mirror polished etc. complete to the approval of the Engineer incharge. All junctions shall be sealed with silicon sealant. Further to include required MS framing, drilling, cutting of holes, SS pins, anchors, clamps, finishing junctions with plaster etc. complete to the entire satisfaction of the Engineer incharge. (Location : Security room)
Providing and fixing Urinal partitions made out of 18mm thick approved granite stone urinal partitions machine cut and machine polished (both sides) in one piece and edges polished and semi rounded 500mm x 1050mm size (exposed size) stone fixed in wall securely and grouted and finished in cement sand mortar 1:3 (1 cement : 3 sand) fixed to correct line and level including chasing in wall, curing, cleaning, exposed edge of stone rounded / chamfered and polished etc. all complete as shown in the drawing and to the satisfaction of the Engineer incharge. (Location: Gents Toilet, Drivers toilet)
Providing, machine mixing and laying of 100mm thick vacuum dewatered (Tremix) concrete finished (with broom finish) of grade M20 of trap metal for plain cement concrete as per detail drawings including dewatering, steel form work, compaction, panels as specified and as per recommendation of manufacturer of equipment, power floating and broom finishing or finishing smooth as specified, cutting concrete for groove as expansion joint about 1/3rd depth of concrete and 12mm wide, filling grooves with approved bitumen based sealant, cleaning, curing surface etc. all complete to the entire satisfaction of the Engineer incharge. Further including applying of non-skid epoxy hardener as approved as per direction of approved manufacturer. (Location : Ground Floor)
Providing, supplying and fixing 2 hours fire rated door with pressed metal frame 100mm x 57mm size out of hot dip galvanized mild steel sheet of 1.5mm thickness including required angle threshold of hot dip galvanized mild steel angle of section 35 x 35mm, or base ties of 1.25mm pressed hot dip galvanized mild steel welded or rigidly fixed together by mechanical means, Frames shall be fixed with 3 nos. G.I. holdfast 200 x 30 x 3 mm with split end on either side and well grouted with cement concrete mix 1:2:4; adjustable lugs with split end tail to each jamb, including stainless steel ball bearing butt hinges (4" x 3" x 3mm) of approved make strengthened with SS pins, lock strike-plate, shock absorbers as specified and 46 mm thick single leaf shutter made out of minimum 1.25 mm thick galvanised sheet insulated with mineral wool for required fire rating and tested as per latest IS specification IS 3614 Part-II. Further include priming with Zinc-Phosphate Stoving Primer and finishing with Polyurethane Aliphatic grade paint in approved shade and colour complete, at all levels and locations, as per drawing to the entire satisfaction of the Engineer incharge.
D4- Single leaf Door Size : 1200mm x 2175mm (Location : ups /electrical room) Ironmongery:- a) SS Ball Bearing Butt hinges size 102mm x 76mm x 3mm - 3 No. b) SS Pull handle H type 600mm long, 32mm dia - 1 Pair c) SS Mortice lock- 1 No. d) SS Rubber Door Stopper - 1 No. e) SS exposed door closer- 1 No. f) 300mm x 300mm & 12mm thick vision panel- 1 Nos
FRD-1- Double leaf Door Size : 1500mm x 2450mm (Location :, hvac and passage area rooms). Ironmongery: a) SS Ball Bearing Butt hinges size 102mm x 76mm x 3mm - 6 Nos. b) SS Pull handle 600mm long, 32mm dia - 2 Pair c) SS dead lock with master key d) 300 x 300mm & 12mm thk. fire rated clear glass vision panel @ 1400mm Ht. FFL- 2 No. e) SS Exposed Door closer- 2 Nos.
FRD- Single leaf Door Size : 1200mm x 2175mm (Location : Staircase entry door, IBMS). Ironmongery: a) SS Ball Bearing Butt hinges size 102mm x 76mm x 3mm - 3 Nos. b) SS Pull handle H- type 600mm long, 32mm dia - 1 Pair. c) SS dead lock with master key- 1 Nos d) 300 x 300mm & 12mm thk. 2 hrs fire rated clear glass vision panel @ 1400mm Ht. FFL- 1 No. e) SS Exposed Door closer- 1 Nos. f) Panic Bar- 1 Nos.
as per above Item No. 7.3 but for 25mm thick shaft door with pressed metal frame 50mm x 75mm size out of hot dip 16 Gauge galvanized mild steel sheet of 1.2mm thickness as per detail drawing. SD- Double leaf Door Size : 900mm x 1800mm (Location : FF shaft) a) SS Ball Bearing Butt hinges size 102mm x 76mm x 3mm - 6 Nos. b) SS dead lock with master key c) SS pull handle- 2 Pairs d) 1000mm x 300mm & 4mm thick vision panel- 2 Nos.
As per above Item no. 7.5 but for 30mm thick Aluminium louvered door with aluminium having PEF grade powder coating (Jotun / Akzonobel of equivalent) of 60 micron in colour and shade as detailed in drawing or directed by the Engineer incharge. SD1- Single leaf Door Size : 450mm x 1800mm (Location : Electrical shaft) a) Ball Bearing Butt hinges size 102mm x 76mm x 3mm - 3 Nos. b) Dead lock with master key. c) Pull handle H- type 600mm long, 32mm dia - 1 Pair
Providing, fabricating and fixing M.S. Railing 1200mm high out of 50mm dia & 5mm thick pipe section hand rail out of 'C' Class pipe, 50 x 50 x 5mm section in vertical spaced @ 1200mm C/C including M.S support & 25mm thick inclined spaced @250mm c/c, coated with iron oxide paint and finished with poly urethane paint with approved colour and make as per drawing out of square bars / class ‘C’ pipes / tees / angles / flats etc. including providing and fixing GI hold fast as necessary to the of RCC members / brick work, electric welding the joints and grinding smooth the welded joints to give one piece appearance including taking site measurements and preparing shop drawing, getting approval of shop drawing prior to fabrication all complete to entire satisfaction of the Engineer incharge. (Location : Staircase)
Providing, fabricating and fixing MS grill for service slabs (Shaft covering), made of 150 x 50 x 5 mm as primary member & 50mm x 50mm x 5mm as secondary member MS box section, MS net on top as per approved sample including cement concrete 1:2:4 block of required size, welding, priming with zinc rich primer etc. complete as directed. (Location : All floor Shafts)
ALUMINIUM COMPOSITE PANEL CLADDING (ACP)Designing, providing, fabricating and installing cladding of 4mm thick (0.5mm + 3mm + 0.5mm) aluminium composite panels with FR core of approved make, for sizes and panels (based on concept architectural elevation drawings) including required fixtures and fittings of stainless steel (SS 316 grade), anchor fasteners, jointing and sealing with M/s. Dow Corning silicon sealant, required fire stops, water drains and gutters and finishing junctions with concrete, stone, timber, aluminium, glass etc. all complete. Further include required preparation of shop drawings with structural calculations and getting approval from the Architect and structural consultants, providing samples, mock-ups, taking actual site measurements and modifying and coordinating with site and fabrication yard, all conforming to international standards etc. complete to the approval of Engineer incharge. Further the system installed and tested shall be guaranteed for 10 years in approved proforma on stamp paper of appropriate value. (Location at Roof decking area periphery)
Providing and fixing 12.5mm thick plain or coffered Gypsum False Ceiling manufactured by M/s. Saint-Gobain or equivalent approved on G.I. frame work, in G.I. vertical supports at every 450mm c/c and horizontal runners at every 900mm c/c in brass screws to proper line and level. Cost to be inclusive of making holes and required framing for fixing electrical fixtures, A.C. grills etc. G.I. metal frame to be of 22 gauge folded strip of 50mm width to be used. All complete as per Engineer in charge's instructions and specifications. The grid of frame work to be supported at every 1500mm x 1500mm interval by 4mm GI suspension rod/wire with adjustable Butterfly Clips of 4mm dia securely affixed to structural ceiling using 10mm dia hook type anchor fastener. All vertical G.I. framework to be anchored to the slab by means of anchor fasteners including all lighting troughs, coffers, 150mm high cornices and all other related works.
CALCIUM SILICATE HILUX MOISTURE RESISTANT CEILING - fabricate and install suspended ceiling which includes Gypsteel perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along the perimeter of ceiling, screw fixed to brick wall/partition with the help of nylon sleeves and screws, at 610mm centres. Then suspending Gypsteel intermediate channels of size 45mm (0.9mm thick with two flanges of 15mm each) from the soffit at 1220mm centres with Gypsteel ceiling angle of width 25mmx10mmx0.55mm thick fixed to soffit with GI cleat and steel expansion fasteners( Saint Gobain Gyproc). Then Gypsteelof 0.55mm thickness having knurled web of 51.5mm and two flanges of 26mm each with lips of 10.5mm are then fixed to the Gypsteel intermediate channel with the help of connecting clip and in direction perpendicular to the Gypsteel intermediate channel at 457.5mm centres. Single layer of 12mm tapered edge calcium silicate is then screw fixed to ceiling section with 25mm drywall screws at 230mm centres. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. prices inclusive of all cut outs required for services or any other related works. Prices inclusive of the cost of doing the verticals wherever ceiling is exposed
Providing & fixing openable type trap doors in false ceiling in 19mm thick commercial ply with necessary wooden framework in CP teak including hinges, locking arrangements etc. Complete finished with 1.0 mm thk approved laminate or gypsum boarding as per instructions .
Providing & applying 1st quality Plaster of Paris (POP) Punning 12-15 mm thick over plaster surface to bring the surface in neat plumb, line & level and make it smooth, including making groove at junctions of dissimilar materials.
Providing and applying Oil paint (Enamel paint) of approved make and colour conforming to IS in two coats (surface and finish acceptable to the Engineer incharge must be achieved by the contractor and any additional coats if required shall be at the cost of the contractor); including preparing surfaces, filling up with gypsum or approved crack filler, binder; cleaning and making the surface dust-free, applying a sealer or primer coat of paint as recommended by approved paint manufacturer, applying two coats of paint (of approved make and shade), required scaffolding, cleaning and protecting till the handing over of site to the employer all complete to entire satisfaction of the Engineer incharge.
Providing and applying Plastic Acrylic emulsion paint of approved make and colour conforming to IS in two coats (surface and finish acceptable to the Engineer incharge must be achieved by the contractor and any additional coats if required shall be at the cost of the contractor); including preparing surfaces, filling up with gypsum or approved crack filler, binder; cleaning and making the surface dust-free, applying a sealer or primer coat of paint as recommended by approved paint manufacturer, applying two coats of paint (of approved make and shade), required scaffolding, cleaning and protecting till the handing over of site to the employer all complete to entire satisfaction of the Engineer incharge.
Providing and applying two or more coats of approved White wash (surface and finish acceptable to the Engineer incharge must be achieved by the Contractor and any additional coats if required shall be at the cost of the Contractor) including preparing surfaces, required scaffolding etc. all complete at all leads and lifts to entire satisfaction of the Engineer incharge.
Providing and applying Texture paint of approved make and colour conforming to IS in two coats (surface and finish acceptable to the Engineer incharge must be achieved by the contractor and any additional coats if required shall be at the cost of the contractor); including preparing surfaces, filling up with gypsum or approved crack filler, binder; cleaning and making the surface dust-free, applying a sealer or primer coat of paint as recommended by approved paint manufacturer, applying two coats of paint (of approved make and shade), required scaffolding, cleaning and protecting till the handing over of site to the employer all complete to entire satisfaction of the Engineer incharge.
Providing and applying minimum 6 mm thick silk finish plaster of paris over plastered surface as detailed above including making level beads, cutting, finishing and scrapping smooth to perfect line and level; including touching, finishing adjoining cornices, drips, corners, pattas, sills etc.; checked with 3 m aluminium edge and no undulation shall be permitted etc. all complete as directed and approved by the Engineer incharge at all locations marked in drawings.
Providing & Applying approved colour paint approved paints in two coats, over two coats of white cement over one coat of primer as per manufacturers specification and technical manual including required cleaning of the surfaces, curing, required scaffolding / staging / temporary hoisting etc. complete to the approval of the EIC. .
Providing Damp Proof Course 40 mm thick 1:1.5:3 concrete (10 mm and down graded aggregate) with 2% of approved admixture of water proofing compound all complete. Two layers of hot bitumen coating 85/25 grade as per IS:702 @ 2Kg./sqm & 1.6kg/sqm shall be applied one before & one after the DPC. All complete as per standard technical specification.
Providing & applying 3 coats of Synthetic Enamel Paint, in spray paint application to specified areas, with necessary base preparation making surface clean, in perfect line & level filling all gaps, cracks etc, using approved shade, to ceiling, walls, columns, wooden, steel surface etc.( EXPOSED MS ELEMENTS)
Providing and applying to surfaces melamine polish in 3-4 coats, including base preparation, filling, jointing sanding, staining etc, in perfect intensity and level.
Providing & applying Painting of walls with first base acrylic primer coat & two finishing coasts of approved exterior grade stone finish textured paint, double spray coat or eq. of approve shade & colour complete over wire brushed and cleaned as per manufacturers specs .Finishing walls with textured exterior paint of required shade New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/ 10 sqm etc complete . as per instruction given by Architect/
Providing and fixing Luxalon® SL-4 84R Plain Panel Sun Louvres manufactured by M/s. Hunter Douglas India Pvt. Ltd. of approved colour consisting of panel 84 mm wide x 16mm deep x 0.6mm thick with round edges panel length upto 6mtrs coil coated on a continuous paint line double baked and roll formed from enamelled corrosion Resistance Aluminium Alloy AA3005 (Al.Mg.) for higher strength and good Roll forming characteristics. Panel shall be clipped to baked enamelled Aluminium SL-4 panel stringer of 33mm wide and 86mm deep x 0.95 mm thick in a standard length of 5mtrs made of double baked enamelled Aluminium Alloy AA5050 (Al.Mg.) black with cut-outs to hold the panel in a module of 86mm centre to centre at a distance of 1mtr. The carrier shall be fixed to a suitable structure by means of rigid fixing details. LUXALON® Aluminium Panel Sun Louvres SL-4 84R Plain Paint Finish: Aluminium panels shall be chromatised for maximum bond between metal and paint, enamelled twice under high temperature one side with full primer and Luxacote finish, the other side (inner side) with a primer coat and Skin Coat on a Continuos Paint Line. Mode of Measurements: Measurements shall be Length and Breadth of the facia without any deductions for any openings.
TWO TRACK TWO SHUTTER SLIDING WINDOW: Providing,Supply, Fabrication & Installation of 27 mm approved make Domal series 2 track 2 shutter sliding window with 18mm thk DGU (5mm thk clear toughened glass + 8mm air gap + 5mm thk clear toughened glass) glass. Using double roller adjustable brearings, Wool pile, EPDM gsket & Lock. Aluminium sections shall be powder coated with 60 to 80 micron as per approved shade by architect / client. SIZE 1500 mm x 1400 mm approximate.
FIX WINDOW Providing,Supply, Fabrication & Installation of fix window, 52mm Z series with 18mm thk DGU (5mm thk clear toughened glass + 8mm air gap + 5mm thk clear toughened glass) glass. Using EPDM gasket & SS screws. Aluminium sections shall be powder coated with 60 to 80 micron as per approved shade by architect / client. SIZE 3650 mm x 2450 mm
ADJESTEBLE LOUVERS WINDOW: Providing, Supply, Fabrication & Installation of adjustable Louvers window with 4mm thk Frosted glass. Aluminium rectangular tube of 25x38 shall be fix to RCC / Wall with SS 304 Grade screw #8x50 with PVC sleeves. 4mm thk frosted glass will fix with aluminium adjustable louvers with clip. all Aluminium sections shall be powder coated with 60 to 80 micron as per approved shade by architect / client. SIZE 600 mm x 900 mm
Providing & Fixing of structural glazing by 6 mm clear tempered glass fix on Aluminium pipes and angles, anchor fasteners, 8 x 6 double sided spacer tape, structural silicon, weatherproof silicon and hardware material
Providing and fixing thermal insulation tray for the spandrel area .The spandrel area shall consist of Glass wool of density 48 Kg/m3 with a GI Back up tray internally duly painted and external surface to be finished with Black tissue for Conventional curtain wall & Structural Glazing at all levels and heights.
SUN CONTROL FILM: providing and applying approved sun control film of 3M or Garware on existing glass window with approved shade and colour. etc complete as per architects instructions and details.
LIFT work Providing and Installation proposed lift MRL Passenger Elevator 10 Pax considering the lift shaft 1.71 Mtr width and 1.95 Mtr depth . Total No of stops 4 (Ground floor + 3 floors ) car size 1200 (W) x 1400 (D) x 2300 (H) Speed 1 MPS Telescopic (Side Opening) door opening size 800 x 2100 mm, pit Depth 1.8mtr, Head room 4500 mm Finish Considered SS Hairline including all Necessary fitting fixture as per manufacture technical deco brochure and commercial terms and conditions (Excluding the liasioning work)
FIRE ALARM SYSTEM
Design, Supply, Installation, Testing & Commissioning of Fire Alarm System c/w Mimic Panel, panel wiring, Programming Software, Testing & Commissioning to integrate with lift & PA system. Detail quantity, drawings & components require to installation on site to be work out by Vendor. Testing & Commissioning of Fire alarm system hookup with existing system.
Supply, installation, testing and commissioning of Microprocessor based 2-loop & expandable upto 5 loop, Networkable Addressable Integrated Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 event plus 1000 alarm log history events, programmable keypad. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop. Each loop shall support minimum 125 detectors & 125 modules after reduction of 20% spare capcity. The panel shall work in degrade mode in case of CPU failure, Products not having this feature must offer Redundant CPU. Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition. The fire alarm panel shall be networkable on fiber optics network without any media convertor & shall data transmission rate minimum 80 mbps on fiber network & minimum 200 kbps on Copper wire network. The network capacity shall be minimum 99 network nodes. The fire alarm panel shall have ability to "ADD" & "EDIT" system database like detectors & modules without use of any special tool/PC/dongle etc. to avoid dependency on specific system integrator/OEM. The unit shall be complete with mounting all required mounting accessories. Designed to meet UL864, 10th Edition Approvals: UL Listed & FM Approved Note: The fire alarm panel shall be servicable by any system integrator without depndency on OEM.
Supply, installation, testing and commissioning of Repeater Panel with control keys. Panel shall have minimum 600 characters LCD display.
Supply, installation, testing & commissioning of addressable Multi-criteria Photo-Thermal Detector with sensitivity range of 0.5 to 4.0% obs/ft.The shall include the thermal sensor. The detector shall have twin bi-colour LED for 360 deg viewing. The unit shall be complete with mounting all required mounting accessories. Designed to meet UL268, 7th Edition Approvals: UL Listed & FM Approved
Supply, installation, testing & commissioning of addressable Multi-criteria Photo-Thermal Detector with sensitivity range of 0.5 to 4.0% obs/ft.The shall include the thermal sensor. The detector shall have twin bi-colour LED for 360 deg viewing. The unit shall be complete with mounting all required mounting accessories. (with suitable mountings for above false ceiling appliaction) Designed to meet UL268, 7th Edition Approvals: UL Listed & FM Approved
Supply, installation, testing & commissioning of Sounder cum Strobe rated at 75 dBA @ 3m for Audible annunciation and 110 cd flashintg at 1 Hz for visual indication. The unit shall be complete with mounting all required mounting accessories. Approvals: UL Listed
Supply, installation, testing & commissioning of addressable Control Module for Sounders / Strobes / Sounder cum Strobes/Directional Sounder. The control module shall provide supervised NAC output rated at 24V DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance. The unit shall be complete with mounting all required mounting accessories. Approvals: UL Listed & FM Approved
Supply, installation, testing & commissioning of addressable Dual Action Manual Pull Station (Push In-Pull Down type). The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. The unit shall be complete with mounting all required mounting accessories. Approvals: UL Listed & FM Approved
Supply, Installation, Testing and Commissioning of Remote Response indicator complete as required.
Supply, installation, testing & commissioning of Sounder cum Strobe rated at 75 dBA @ 3m for Audible annunciation and 110 cd flashintg at 1 Hz for visual indication. The unit shall be complete with mounting all required mounting accessories.
Cable work: Supply and laying of cables including fixing accessories, tray, trunking, conduits, saddles, clamps, ties, tags, termination of cables etc. Cable length and quantity are to be finally worked out by contractor at site based on actual measurements.Laying shall be inclusive of supply of wires, providing tray, trunking, galvanized steel tubes (conduit) / trunking, pull wires, tees / bends / elbows, junction / pull out boxes, etc., clamps / saddles for conduit clamping with all accessories & hardwares as required. 2C x1.5 mm2 twisted FRLS armoured multistrand cable
PA SYSTEM
Design, Supply, Installation, Testing & Commissioning of PA & Evacuation System. Detail quantity, drawings & components require to installation on site to be work out by Vendor and Testing & Commissioning support for PA system
Supply of main 6 zone PA & Evacuation Controller with inbuild 120W/240W Amplifier with all required accessories like audio input/output module, control output module, power supply unit c/w frame, volume control zone etc. Voice Alarm controller with USB, MP3, AM/FM player for playing audio and overwriting incase of Fire Alarm. meeting the intents of technical specifications
6W public area ceiling speakers complete with back box and with all the acccessories
Cabling work: Supply and laying of cables including fixing accessories, tray, trunking, conduits, saddles, clamps, ties, tags, termination of cables etc. Cable length and quantity are to be finally worked out by contractor at site based on actual measurements.Laying shall be inclusive of supply of wires, providing tray, trunking, galvanized steel tubes (conduit) / trunking, pull wires, tees / bends / elbows, junction Box / pull out boxes, etc., clamps / saddles for conduit clamping with all accessories & hardwares as required.
2C 1.5 sqmm FR Mylan Shielded copper , multistrand, twisted pairs, PVC armoured wires having fire retarded low smoke insulation.
Shielded Cat6 Cable for call station with RJ45 connectors.
6 zone call station with microphone
Music Source DVD Player/MP3 Player/ USB
PLUMBING SYSTEM
Providing and fixing white vitreous china flat back type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively.
E.W.C.:Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, level white P.V.C. flushing cistern with capacity as mentioned below, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. It should include 'P' or 'S' trap as per approved make with left or right vent in position including fixing it on chair brakcet or wall bracket. With necessary C.P. brass screws & plugs etc. Floor mounted EWC Universal with 5 to 7 Ltrs Cistern - white colour
Hand Spray wth PVC connection approved equivalent make (1M long) as per the instruction of engineer incharge.
2 Way Bib-Cock with connection for Health Faucet of approved make and as per the instruction of Engineer incharge.
Under Counter Sink including waste Coupling. WASH BASIN: Providing and fixing white vitreous china counter wash basin including making all connections but excluding the cost of fittings white colour angle back wash basin of size 630 X 450 mm
FANCY PILLAR TAP: Providing & fixing approved make heavy quality C.P. brass screw down pillar tap long nose not less than 810gm. with jam nut easy clean variety of 15 mm n.b. etc. complete all as directed by the Engineer-In-Charge
Providing and fixing Bottle trap with Wall Connection Pipes & Wall Flange weighing Not less than 263 gms. Extra if required. All as per the instruction of Engineer incharge.
Providing and fixing Fancy Angle Stop Cock including all fittings required to fix it as per the instruction of Engineer incharge.
Providing & fixing 100mm dia C.I heavy duty nahani trap as per the instruction of engineer incharge.
Providing and fixing Grab handle / Grab Bar of minimum 300mm length of approved make and design as per the instruction of Engineer incharge
TOWEL ROD: Providing & fixing approved C.P. brass towel rods of size 600mm x 20mm heavy duty with a pair of C.P. brass brackets wall flanges etc. fixed to wall with C.P. screwed on the raw plugs etc. complete as and when required and as directed by the Engineer-In-Charge.
Providing and fixing beveled edge mirror of superior glass (of approved quality) and of required shape and size with designer frame of approved make and complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Rectangular shape Rectangular shape 453x357 mm
Pressmatic Taps approved Make :Urinal Valve Auto Closing System with Built-in Control Cock with Wall Flange. Providing and fixing including removal of existing if any as per the instruction of EIC
S.S pipe clean out plugs with S.S. cap of following sizes for maintenance and cleaning purpose etc. complete as per directions of engineer-in-charge. (Optional in case require at site).75 mm dia.
HDPE clean out plugs with brass cap of following sizes for maintenance and cleaning purpose etc. complete as per directions of engineer-in-charge. (Optional in case require at site)
75 mm dia.
110 mm dia.
150 mm dia.
Providing, laying, jointing, fixing, testing, commissioning HDPE Pipes & Fittings conforming to IS:14333 with GI specials as required, cutting the pipes to the required lengths, threading, jointing the pipes using suitable Adhesive for HDPE (PE-100, PN-6, 110mm Dia 6 wall thickness)- ( For all internal and vertical drain lines)
40 mm dia.
50 mm dia.
75 mm dia.
100 mm dia.
Forged brass Ball valve/butterfly valve (PN 10) with body of brass and ball & stem of Stainless Steel with material and labour etc all complete as per drawings, specifications and to the level of satisfraction of Site- Incharger
20 mm dia
25 mm dia
CPVC Pipes conforming to ASTM D-2846, SDR-11 grade and CPVC solvent weld fittings like elbows, tees, couplers, brass threaded adapters, insert ring etc. suitable for (domestic hot water) applications rated, concealed piping within wall / floor including jointing with fittings using solvent cement ,brass threaded end fittings for making connection to fixtures. The work shall also include chasing the walls with machine wherever required for concealed piping and making good the same after laying of pipes & necessary pressure testing Chasing finishing shall be done with 1:1 cement mixed mortar, restore the same original condition for internal and shaft piping, including necessary hot deep galvanized supports vertical / horizontal, as per direction of Site in charge direction. The rate shall include supply of S. S. screws and nut bolts etc. chasing in walls done by machine (CPVC PIPING )
20 mm Dia
25 mm Dia
65mm Dia
ELECTRICAL WORK
SECTION-I : PANELS & DB'S ELECTRICAL PANELS & DISTRIBUTION BOARDS: FABRICATED IN 14/16 SWG CRCA SHEET STEEL, POWDER COATED TO DESIRED SHADE. FULLY COMPARTMENTALIZED, SELF SUPPORTING TYPE.COMPLETE WITH BASE FRAME, KNOCK OUTS FOR CABLE GLANDS ETC.,ALL SWITCHGEARS, METERING, PROTECTION, INDICATIONS, TYPES Etc., :NOTE :Prospective Bidders to visit Site, Review existing Panels & DB's etc.Existing Panels andd DB's to be Refurbished appropriately as per this BOQ/ BOM :ALL SWITCHGEARS ABOVE 160A, SHALL HAVE MICRO-PROCESSOR BASED RELEASES UNLESS SPECIFICALLY DEFINED.MBR : MICRO-PROCESSOR BASED RELEASES FOR ( SC-OC-EF ).ALL SWITCHGEARS UPTO 160A, SHALL HAVE THERMAL MAGNETIC RELEASES UNLESS SPECIFICALLY DEFINED.TMR : THERMAL MAGNETIC RELEASES FOR ( SC-OC-EF )..
SUPPLY, INSTALLATION, TESTING & COMMISSIONING :Unloading, Shifting, Installation, Testing and Commissioning of following distribution boards. MCB distribution boards shall be totally enclosed with double door, vertical, surface/recessed mounting type, outer door shall be hinged type with push intype spring / magnetic lock, inner door shall be fixed up with screws with cut outs for MCB operation, copper bus bar of at adequate space for termination of incoming and outgoing cables,removable undrilled top & bottom gland plates, suitable for wall, column mounting type. he incoming MCCB shall be provided in separate compartment & shall have front drive mechanism and door interlock.The DB shall be fabricated out of 1.6 mm thick CRCA sheet steel . DB shall be completely wired up, up to incoming and outgoing terminals by PVC insulated flexible copper wire of adequaterating. All MCB in Power DB shall be suitable for Motive power (Curve C). Wherever standard DB's of DB manufacturers available, same shall be used. DB's shall be pre-wired and pre-assembled. Rate should be inclusive of the PPI kit, adaptor box for proper terminations of cables.
MPDB1/DG: On Incomer : LM- Digital Type CT's etc. with RS485 Comm. Ports. Phase Indication Lamps, ON-OFF-TRIP Indications on Incomer.INCOMER :250A- FP,MCCB,36kA With SC-OC-EF , thermal magnetic release250 A- TPN AL Bus Bars. ( AL Electrolytic : 1.0sq.mm = 0.8 Amps.).O/G :All MCCB Outgoings to have : LM- Digital Type, w/ CT's etc. 100A ,TPN, MCCB,25kA,TMR………. 1 No. 40A ,TPN, MCB,10kA………. 1No. 25A ,TPN, MCB,10kA,………. 2 No
MPDB2/ RAW: On Incomer : LM- Digital Type CT's etc. with RS485 Comm. Ports. Phase Indication Lamps, ON-OFF-TRIP Indications on Incomer.INCOMER :250A- FP,MCCB,36kAWith SC-OC-EF , thermal magnetic release250A- TPN AL Bus Bars. ( AL Electrolytic : 1.0sq.mm = 0.8 Amps.).O/G :All MCCB Outgoings to have : LM- Digital Type, w/ CT's etc. 200A ,TPN, MCCB,25kA,TMR………. 1 No32A ,TPN, MCB,10kA,……….1 No16A ,TPN, MCB,10kA,………. 1 No
RPDB 1/Process Equipment + 3 Phase Socket3Ph., 10/12 Way TPN-DB. PPI/Phase Segregated. ( LEGRAND/ HAGER/ SCHNEIDER Make.)I/C : 40A ,TPN, MCB,10kA. O/Gs : 40A-DP-RCCB., 100mA. .. 1 Nos. ( R-Y-B).Phased O/Gs : C Curve type. 16A- SP-MCB's.. 01 Nos.16A- TPN-MCB's.. 07 Nos.SPARE:- 2 Nos.
RPDB 2/Minor UT: 3Ph., 6 Way TPN-DB. Phase Segregated. ( LEGRAND/ HAGER/ SCHNEIDER Make.) I/C : 25A- TPN , MCB. O/Gs : 20A-DP-RCCB., 100mA. .. 3 Nos. ( R-Y-B).Phased O/Gs : C Curve type16A- SP-MCB's.. 10 Nos.Spare:- 2 Nos.
RPDB/3-HVACOn Incomer : LM- Digital Type CT's etc.Phase Indication Lamps, ON-OFF-TRIP Indications on Incomer.INCOMER :200A- TPN , MCCB,MPB. 25kA. (SC-OC-EF)200A- TPN AL Bus Bars.( AL Electrolytic : 1.0sq.mm = 0.8 Amps.).O/G :All Outgoings to have : ON-OFF-TRIP IND 125A ,TPN, MCCB,25kA,TMR………. 2 No. 40A- TPN-MCB…..02 Nos. 16A- TPN-MCB…..02 Nos. 25A- DP-MCB…..02 Nos.10A- DP-MCB…..02 Nos. SPARE :-63A TPN MCB…. 1 Nos.
LDB: 3 Ph., 8 Way TPN-DB. Phase Segregated. ( LEGRAND/ HAGER/ SCHNEIDER Make.)I/C : 16A- TPN , MCB,10KAO/Gs : 16A-DP-RCCB., 30mA. .. 3 Nos. ( R-Y-B).Phased O/Gs : C Curve type6A- SP-MCB's.. 09 Nos.SPARE:- 2 Nos.
UPS INPUT POWER :100A- TPN, MCCB,TMR 25kA.,.In M. S. Enclosure. ….1Nos
UPS O/P PANEL INCOMER :100A- TPN, MCCB,TMR 25kA(SC-OC-EF)100A- TPN AL Bus Bars.( AL Electrolytic : 1.0sq.mm = 0.8 Amps.).O/G :All Outgoings to have :63A MCB,TPN,10kA…..1 No.25A MCB,DP,10kA…..1 No.
UPSDB/1-SPL-GF3Ph., 8/10 Way TPN-DB. Phase Segregated. ( LEGRAND/ HAGER/ SCHNEIDER Make.)I/C : 63A- TPN , MCB,10KAO/Gs : 63A-DP-RCCB., 100mA. .. 3 Nos. ( R-Y-B).Phased O/Gs : C Curve type16A- SP-MCB's.. 17 Nos.25A- SP-MCB's.. 1 Nos.
ELDB3Ph., 4 Way TPN-DB. ( LEGRAND/ HAGER/ SCHNEIDER Make.)I/C : 25A- TPN , MCB,10KAO/Gs : 16A-DP-RCCB., 30mA. .. 3 Nos. ( R-Y-B).O/Gs : 6/10A- SP-MCB's.. 06 Nos.
Replacement of Switchgear in Existing Power Panel :1.The Switchgare shall be supplied and installed in existing switchboard/panel. Therefore, before quoting, the Vendor shall visit site, collect all required information’s and make themselves familiar with the work actually involved and actual site conditions. 2.Vendor shall quote for removal of old switchgare, testing & commissioning.250A- FP ,MCCB (INCOMER-1)With SC-OC-EF , thermal magnetic releaseComplete Job with adequate Connectivity to Common Bus.250A- FP ,MCCB (INCOMER-2)With SC-OC-EF , thermal magnetic releaseComplete Job with adequate Connectivity to Common Bus.
Providing Cables : XLPE-SWA-PVC : SUPPLY,INSTALLATION, TESTING & COMMISSIONING : Supply,Unloading, Laying, Testing and Commissioning of 1.1KV Grade XLPE/PVC FRLS insulated stranded copper conductor steel of armoured/unarmoured power cables as per the specs. Laying of Cables in horizontal/vertical formation on cable trays, supported along RCC/steel structures, pipe racks and cable supports provided, include unloading, shifting up to site at various location/levels, unpacking & inspection. The scope includes clamping of cables by readymade G.I. spacers, saddles, cable ties or clamps fabricated out of MS strip 3 mm thick along vertical runs and wherever specified, cutting of the cable as per actual measurement/cable schedule, Treasing and Clamping of Cable on cable tray, supply of all clamping materials and hardware etc., providing cable tags made out of aluminium strip and 75x20 mm in size with cable number and size punched on it. Cable tags shall be tied to cables at every 20 meter interval and at both the ends. Supports provided for clamping of cables up to individual motors and push-buttons shall be paid extra as per item rate for MS fabrication work.
Unused cables & Empty cable drums shall be returned to stores. In case of laying unlisted cables, rate of cable whose outer dia is closest to the cable sizes quoted shall be applicable. The same shall hold good for cable termination also. The rates quoted shall be for laying in trays, cable trenches (indoor and outdoor), pipes, along/on the wall/metallic partition etc.Contractor shall take exact measurement as per site feasibility & submit the required quantity to client. Any balance material left shall be taken back by the contractor free of cost, without any cost implication & no extra amount shall be paid for it. SUPPLY, XLPE Insulated etc. - COPPER /ALUMINIUM CONDUCTOR CABLES : 2XWY/2XFY : Sizes :
3.5c x 185 sq.mm. Aluminium-Conductor Armoured XLPE FRLS Cable.
3.5c x 120 sq.mm. Aluminium-Conductor Armoured XLPE FRLS Cable.
3.5c x 70 sq.mm. Aluminium-Conductor Armoured XLPE FRLS Cable.
3.5c x 50 sq.mm. Aluminium-Conductor Armoured XLPE FRLS Cable.
3.5c x 35 sq.mm. Aluminium-Conductor Armoured XLPE FRLS Cable.
3.5c x 25 sq.mm. Aluminium-Conductor Armoured XLPE FRLS Cable.
4c x 25.0 sq.mm. Copper-Conductor Armoured XLPE FRLS Cable.
4c x 16.0 sq.mm. Copper-Conductor Armoured XLPE FRLS Cable.
4c x 10.0 sq.mm. Copper-Conductor Armoured XLPE FRLS Cable.
4c x 6.0 sq.mm. Copper-Conductor Armoured XLPE FRLS Cable.
4c x 4.0 sq.mm. Copper-Conductor Armoured XLPE FRLS Cable.
4c x 2.5 sq.mm. Copper-Conductor Armoured XLPE FRLS Cable.
3c x 6.0 sq.mm. Copper-Conductor Armoured XLPE FRLS Cable.
3c x 2.5.0 sq.mm. Copper-Conductor Armoured XLPE FRLS Cable.
SUPPLY, INSTALLATION, TESTING & COMMISSIONING : Providing Cable End Terminations : S,I, T & C : LT Termination : 1) Termination of XLPE/PVC insulated armoured cables (up to 11 kV grade) and connection of leads including the supply of cables glands and lugs & including cutting, stripping of cable insulation, drilling of gland plate, fixing of cable gland, crimping the lug on to the conductor, supply, fixing & marking with number ferrules etc. All necessary GI consumables & hardware, including all labour and materials complete as per approved drawings, directions of Engineer-In-Charge. The scope includes all standard tests, as specified. Scope will also include provision of additional supports, if required, with steel for proper dressing & support of cables as per approved drawings, specification and directions of Engineer-In-Charge.
2) Supply, installation of the terminations with double compression type Brass-Nickel cable gland, lugs & PVC Shrouds. The gland shall be provided with earth tag , ensures earth continuity between gland and equipment, etc. complete as required. XLPE Insulated etc. - COPPER /ALUMINIUM CONDUCTOR CABLES : 2XWY/2XFY : Sizes :
3.5c x 240 sq.mm. Aluminium-Conductor Armoured XLPE FRLS Cable.
3.5c x 185 sq.mm. Aluminium-Conductor Armoured XLPE FRLS Cable.
3.5c x 150 sq.mm. Aluminium-Conductor Armoured XLPE FRLS Cable.
3.5c x 120 sq.mm. Aluminium-Conductor Armoured XLPE FRLS Cable.
3.5c x 95 sq.mm. Aluminium-Conductor Armoured XLPE FRLS Cable.
3.5c x 70 sq.mm. Aluminium-Conductor Armoured XLPE FRLS Cable.
3.5c x 50 sq.mm. Aluminium-Conductor Armoured XLPE FRLS Cable.
4c x 16.0 sq.mm. Copper-Conductor Armoured XLPE FRLS Cable.
4c x 10.0 sq.mm. Copper-Conductor Armoured XLPE FRLS Cable.
4c x 6.0 sq.mm. Copper-Conductor Armoured XLPE FRLS Cable.
4c x 4.0 sq.mm. Copper-Conductor Armoured XLPE FRLS Cable.
3c x 6.0 sq.mm. Copper-Conductor Armoured XLPE FRLS Cable.
3c x 2.5 sq.mm. Copper-Conductor Armoured XLPE FRLS Cable.
Providing FLEXIBLE Cables : FR./FRLS. Gr. : S, I, T & C : PVC Insulated, Unarmoured & Multistranded, Industrial Copper Conductor Cables : Sizes :
4R..1C x 35.0 sq.mm. Cu. PVC. Fr. HD. (For UPS: I/P & O/P -Connectivities & dedicated neutral).
1c x 70 sq.mm. Cu. PVC. Fr. HD.
1c x 35 sq.mm.
Providing Cable End Terminations : TO : FLEX. CABLES : S, I, T & C : PVC Insulated, Unarmoured & Multistranded, Industrial Copper Conductor Cables : Sizes :
4R..1C x 35.0 sq.mm. Cu. PVC. Fr. HD. (For UPS: I/P & O/P -Connectivities & dedicated neutral).
1c x 70.0 sq.mm. Cu. PVC. Fr. HD.
1c x 35.0 sq.mm.
METALLIC /PVC Conduits. : S, I, T & C : Supply, Installation of MS/GI/PVC/ pipe and accessories along the wall/ column/ true/ fall ceiling/ floor, roof structure as per site requirement including cutting bending, threading, removing of burs, coupling chipping & excavation as per specification, general engineering practice/standard, and std. Drawing and the direction of Engineer-In-Charge, to complete the work in all respect and to make ready the system to hand over for operation / utilization. The method of laying of Pipe will be surface / concealed as per site requirement and as specified in drg. For under ground laying, pipe shall be laid at a depth of 900 mm below ground level or under paved areas/under floor as required. The scope of the work is including of fixing necessary spacing bars / saddle, clamps as specified, tying of the pipe with reinforced rods, chipping along the wall fixing chicken mesh and making good of the same as specified in drg / required at site. The detailed layout preparation for aesthetic look will be with contractor scope.
All the work to be done in approved manner by providing necessary highly skilled and other labour along with experienced supervisor staff, best quality of tools & tackles. Metallic Conduits :
Flexible PVC Conduits : S, I, T & C :
RIGID PVC / HDPE Conduits Upto 50 mm PVC above 50 mm HDPE: S, I, T & C :
SWITCH BOXES & SWITCH SOCKET :TABLE TOP/ WALL MOUNTING : ETC. : S, I, T & C : Supply, Installation, Testing and Commissioning of domestic(modular sockets) & industrial metal clad switch socket with "C" curve control MCB combination and "C" curve MCB enclosure for Non clean area, enclosed in (IP20) enclosure made out of 1.2 mm thick sheet steel enclosure, pre-treated and painted with two coats of primer and two coats of epoxy paint.(For Industrial sockets) The erection rates shall include fixing of enclosures on wall/concealed in the wall, supply of all fixing accessories/hardware, MCB and socket shall be wired up to outgoing terminals and termination including lugs, ferrules etc., complete as required.(Vendor to provide sample for each type of fitting at the time of GA Approval)
6/16A-Switch Socket outlets .
Non-FLP : SSO : 1 Switch -6/16A-Socket
Non-FLP : SSO : 2 Switch 6/16A-Socket
Industrial Metal Clad Plug Socket with top with MCB:
Non-FLP-25A, single Phase, 3 pin, Industrial type socket with TOP, 20A DP MCB enclosed in 1.2mm thick, CRCA sheet steel box with powder coated front/cover plate.(Concealed Type)
Non-FLP-25A, Three phase, 5 pin Industrial type socket with TOP, 32A FP MCB enclosed in 1.2mm thick, CRCA sheet steel box with powder coated front/cover plate.(Concealed Type)
Non-FLP-32A, Three phase, 5 pin Industrial type socket with TOP, 25/32A FP MCB enclosed in 1.2mm thick, CRCA sheet steel box with powder coated front/cover plate.(Concealed Type)
G. I. RACEWAY-CABLE TRAYS , ETC . : S, I, T & C : Supply, Installation in horizontal & vertical formation of prefabricated perforated / ladder type HOT dipped galvanized (not less than 65 microns) sheet steel cable trays different widths and delivered in standard lengths along with Coupler plates and requisite number of hardware, at different levels along pipe rack, ready made cable trenches, cable cellar, etc., in tier formation as per specifications, drawings, standard engineering practice and as per the direction of Engineer-In-Charge. The Contractor's scope is inclusive of lifting & placing of trays on supports at different levels, aligning, joining of trays with couplers, clamping / fastening of supports to the RCC/METALIC structure & clamping / fastening of cable tray to the support of the vertical portions and wherever required as per specs/ drawings.
All the necessary bends (horizontal / vertical), tees, cross, elbows, reducers, etc., as shown in the drawing and as per the site. Hardware is inclusive of this item. Hardware items (for fixing & aligning of cable tray) are all requisite material like Z-channel, threaded rod, nut, bolt, anchor fastener, screw etc. MS Structural supports are captured elsewhere in the BOQ. The supports should be as follows - For cable tray width from 50mm to 200mm - Z-channel of 50x50x4mm size with 2nos of 8mm rod at every 1.5mtr. For cable tray width from 300mm to 450mm - Z-channel of 50x50x6mm size with 2nos of 10mm rod at every 1.5mtr. For cable tray width from 600mm to 750mm - L angle of 50x50x5mm for both vertical & horizontal supports at every 2 mtr.
Condition / requirement are to be fabricated out of standard length of trays issued and as per standard and good engineering practice. Gas cutting of cable trays at site is not permitted. If any welding is to be done on cable trays applying of two coats of zinc rich primer and one coat of Silver paint at the modified / repaired area/ portions and erection of the same. Without limiting to the above, the work is to be completed in all respects end to end of each route as per the specs, drawings and the direction of the Engineer-In-Charge. Work for External cable tray like supporting pipe rack is under Mechanical / civil contractor scope. IS standard to be comprised - - IS 1079 / 2062 for sheet - IS 2629 / 4759 for Hot dipped galvanization
G. I Raceway with Cover . 75 x 50 x 1.7 mm. Power
G. I Raceway with Cover . 75 x 50 x 1.7 mm. ELV
For Equipment Power Cabling :
100mm wide cable tray perforated type
200mm wide cable tray perforated type
300 mm wide cable tray perforated type
500 mm wide cable tray perforated type
Cable Tray cover
300 mm wide cable tray perforated type
500 mm wide cable tray perforated type
Structural Supports for Cable tray
Supply, Installation & Fabrication of ISI mark GI structural steel in form of angles, channels, flats, Fabricated "C-Z-L" etc. for supporting various items of equipment such 'as various cable trays, push button stations,'junction boxes, light fittings, DB etc. including required hardwares
GI full threded Rod & Cable tray supporting & fixing clamps. Supply, Installation GI full treded rod with Nuts at both ends. 8 mm Thick with All Hardwears
LIGHT & POWER POINT CABLING/WIRINGS : Concealed wiring in HPVC conduits with Modular type Accessories. Point wiring shall include all necessary HPVC FRLS conduits with GI pull wire, conduit fittings, conduit accessories like saddles, spacers, bends, couplings, collars etc., junction / pull / inspection boxes, wires, gland, conduit supports, bushings lamp holders, ceiling rose, flexible conduit/ inspection L bends, fan hooks wherever required & terminations using tinned copper lugs of crimping type. A point wiring shall include in addition the earth continuity conductor/wire from the DB to the earth pin/stud of the outlets/switchbox & to the outlet point.
including cutting bending, threading, removing of burs & coupling as per specification, general engineering practice / standard, and std. Drawing and the direction of Engineer-In-Charge, to complete the work in all respect and to make ready the system to hand over for operation / utilization. The method of laying of conduit will be surface / concealed as per site requirement and as specified in drg. The scope of the work is including of fixing necessary spacing bars / saddle as specified, tying of the conduit with reinforced rods, chipping along the wall fixing chicken mesh and making good of the same as specified in drg / required at site. The detailed layout preparation for aesthetic look will be in contractor's scope.
Lighting Circuits Mains using : 3 Run x 2.5 sq.mm., FRLS Gr. PVC Insulated Copper Wire. This shall cover the wiring from SLDB to First switch board and looping of switch board to switch board. Switch board point Wire-2.5SQMM (Phase, Neutral) Wire 2.5Sqmm (Earthing)
Lighting Circuits including Primary Points , using : 3 Run x 2.5 sq.mm., FRLS Gr. PVC Insulated Copper WirePrimary Light point Wire-2.5SQMM (Phase, Neutral) Wire 2.5Sqmm (Earthing) in Mtr- Switch board to first Light fixture (Average Distance=10m)cables thru provided , Mesh Cable Trays, FRLS Gr. PVC Conduits , secured to walls,Ceiling, Trays etc.
Lighting Points , Looped or Secondary Points, using : 3C x 1.5 sq.mm., FRLS Gr. PVC Insulated Copper WireSecondary Light Point-1.5SQMM (Phase, Neutral) Wire 1.5Sqmm (Earthing) First Light fixture to subsequent light fixture 1 (Average Distance=5m)cables thru provided , Mesh Cable Trays, FRLS Gr. PVC Conduits , secured to walls,Ceiling, Trays etc.
Providing & Fixing of Switches & Sockets complete with accessories for recessed mounting. Supply of Modular switch boards with necessary number of modular box, SS front and rear plate, modular switches, switch sockets & blank plates. The module box shall be concealed in such a way that so front plate flush with wall, all civil work (chasing, chipping providing chicken mesh & plastering )includes in this item. Scope includes fixing of screw cover & marking identification numbers & interconnections as per standard drawing, site requirement & direction of Engineer-In-charge.
6 Amp Switch 1 nos. with 1 Module CRCA box and rear & front (SS 304 MATT finish) plate.
6 Amp Switch 2 nos. with 2 Module CRCA box and rear & front (SS 304 MATT finish) plate.
6 Amp Switch 3 nos. with 3 Module CRCA box and rear & front (SS 304 MATT finish) plate.
6 Amp Switch 4 nos. with 4 Module CRCA box and rear & front (SS 304 MATT finish) plate.
POWER CIRCUIT WIRINGS , USING PVC INSULATED, FRLS, 1.1KV. Gr. FLEX. COPPER CONDUCTOR CABLES. All socket point wiring shall be carried out using 1.5/2.5/4sq. mm copper stranded conductor 660/1100V grade PVC insulated FRLS wire including 25mm dia HPVC FRLS conduit. Circuiting from DB to first Socket & looping of socket shall be done using 3 runsx 1.5/2.5/4 Sq.mm FRLS Copper wires & covered in Primary & secondary socket point wiring.All socket point wiring shall be carried out using 2.5/4sq. mm copper stranded conductor 660/1100V grade PVC insulated FRLS wire including 25mm dia HPVC FRLS conduit. Circuiting from DB to first Socket & looping of socket shall be done using 3 runsx 1.5/2.5/4 Sq.mm FRLS Copper wires & covered in Primary & secondary socket point wiring. Power Circuits from DB to Power Outlets / Equipments using :
3 Run x 1.5 sq.mm. WireThis shall cover the wiring from DB to First socket /Equipment and looping of socket to socket using 1.5 SQMM wirePrimary Socket point Wire-1.5SQMM (Phase, Neutral) Wire 1.5Sqmm (Earthing) - DB TO First Socket
3 Run x 2.5 sq.mm. WireThis shall cover the wiring from DB to First socket /Equipment and looping of socket to socket using 2.5 SQMM wirePrimary Socket point Wire-2.5SQMM (Phase, Neutral) Wire 2.5Sqmm (Earthing) - DB TO First Socket
3 Run x 4.0 sq.mm. WireThis shall cover the wiring from DB to First socket/Equipment and looping of socket to socket using 4 SQMM wirePrimary Socket point Wire-4 SQMM (Phase, Neutral) Wire 4Sqmm (Earthing) - DB TO First Socket
3 Run x 6.0 sq.mm. WireThis shall cover the wiring from DB to First socket/Equipment and looping of socket to socket using 4 SQMM wirePrimary Socket point Wire-6 SQMM (Phase, Neutral) Wire 6Sqmm (Earthing) - DB TO First Socket
4 Run x 2.5 sq.mm. WireThis shall cover the wiring from DB to First socket/Equipment and looping of socket to socket using 2.5 SQMM wireLIGHT FIXTURES & ACCESSORIES For Proper Installation Of The Same At Desired Locations. Suitable for Operation on 230V.AC. 50 hz. Power Supply.
SUPPLY,INSTALLATION, TESTING & COMMISSIONING : Supply, Unloading, Installation, Testing & Commissioning of standard light fittings and lighting accessories .The scope shall includes unpacking assembly of luminaries, providing of all hardware such as chain, nuts, anchor fasteners, bolts, screws, cleats, clamps, PVC insulated wires / cables from Junction box to lighting fixtures, ceiling roses ball and socket 'arrangement with J.B., suspension conduit pipe 1.5 m long 19 mm black MS conduit down rod for light fitting. The cost of fabrication supply and installation of MS supports with anchor fasteners will be the part of this item only. The scope of work also includes any modifications required to be carried out on the mounting bracket to suit mounting of light fixtures & any modification inside control gear box / fixture for proper commissioning of fixture.
NON Clean Room Fixture : 2' x 2': Recessed - 6000*/6500*K .. 60W. Recess mounted NON CLEAN ROOM LIGHT fixture with & milky Diffuser LC & grade Make Bayer etc. having fixture size approx of 600 x 600. The light fixture with bottom frame & 5 mm thk. thoughen glass. ( The color temp of LED lamp to be 6500 Kelvin. Cool Day Light ) System Efficay 120 Lm/watt.THD<10%,Surge Protection >3KV Constant Current driver,PF>0.95 LED .Light Fixture shall be made from CRCA powder coated bottom frame with minimum thickness 0.7mm or more duly epoxy powder coated.non-hygroscopic XLPE Gasket. CRI>70 with Threaded Type hanging arrangement Top Opening, luminair with accessories, suitable for : 60 W LED
NON Clean Room Fixture : 2' x 2': Recessed - 6000*/6500*K .. 40W . Recess mounted NON CLEAN ROOM LIGHT fixture with & milky Diffuser LC & grade Make Bayer etc. having fixture size approx of 600 x 600. The light fixture with bottom frame & 5 mm thk. thoughen glass. ( The color temp of LED lamp to be 6500 Kelvin. Cool Day Light ) System Efficay 120 Lm/watt.THD<10%,Surge Protection >3KV Constant Current driver,PF>0.95 LED .Light Fixture shall be made from CRCA powder coated bottom frame with minimum thickness 0.7mm or more duly epoxy powder coated.non-hygroscopic XLPE Gasket. CRI>70 with Threaded Type hanging arrangement Top Opening, luminair with accessories, suitable for : 40 W LED
Clean Room Fixture : 2' x 2': Surface Mounted- 6000*/6500*K .. 40W. Recess mounted CLEAN ROOM LIGHT fixture with & milky Diffuser LC & grade Make Bayer etc. having fixture size approx of 600 x 600. The light fixture with bottom frame & 5 mm thk. thoughen glass. ( The color temp of LED lamp to be 6500 Kelvin. Cool Day Light ) System Efficay 120 Lm/watt.THD<10%,Surge Protection >3KV Constant Current driver,PF>0.95 LED .Light Fixture shall be made from CRCA powder coated bottom frame with minimum thickness 0.7mm or more duly epoxy powder coated.non-hygroscopic XLPE Gasket. CRI>70 with Threaded Type hanging arrangement Top Opening, luminair with accessories, suitable for : 40 W LED
NON Clean Room Fixture : 1' x 1': Recessed - 6000*/6500*K .. 30W . Recess mounted NON CLEAN ROOM LIGHT fixture with & milky Diffuser LC & grade Make Bayer etc. having fixture size approx of 300 x 300. The light fixture with bottom frame & 5 mm thk. thoughen glass. ( The color temp of LED lamp to be 6500 Kelvin. Cool Day Light ) System Efficay 120 Lm/watt.THD<10%,Surge Protection >3KV Constant Current driver,PF>0.95 LED .Light Fixture shall be made from CRCA powder coated bottom frame with minimum thickness 0.7mm or more duly epoxy powder coated.non-hygroscopic XLPE Gasket. CRI>70 with Threaded Type hanging arrangement Top Opening, luminair with accessories, suitable for : 30 W LED
Recess mounted CLEAN ROOM LIGHT fixture with & milky Diffuser LC & grade Make Bayer etc. having fixture size approx of 300 x 300. The light fixture with bottom frame & 5 mm thk. thoughen glass. ( The color temp of LED lamp to be 6500 Kelvin. Cool Day Light ) System Efficay 120 Lm/watt.THD<10%,Surge Protection >3KV Constant Current driver,PF>0.95 LED .Light Fixture shall be made from CRCA powder coated bottom frame with minimum thickness 0.7mm or more duly epoxy powder coated.non-hygroscopic XLPE Gasket. CRI>70 with Threaded Type hanging arrangement Top Opening, luminair with accessories, suitable for : 30 W LED
Linear Lights -Recessed Linear Profile. IP20/6500*K ..20W (For OFFICE- MEETING ROOM). 1200 mm x 75 mm. 20W- LED Recessed mounted, Linear Lights, IP 20type light fitting with Acrylic Cover , with the accessories like ball sockets, down rod etc. ( The color temp of LED lamp to be 4000 Kelvin. for passages, Open Areas ) System Efficay 120 Lm/watt.THD<10%,Surge Protection >3KV Constant Current driverDriver, PF>0.95. Fixture shall be made from CRCA with minimum thickness 0.7mm or more duly epoxy powder coated.non-hygroscopic XLPE Gasket. CRI>70. (For OFFICE- MEETING ROOM)
60 Watts LED Street Light - 5700*/6500*K WALL MOUNTED. 60 Watts LED Street Light Fixture made from Al. housing complete with toughened die-cast glass cover, control gear & accessories wired upto terminal block. Surge protection> 5KV
2 x 18W Linear Light -Surface Mounted - 5700*/6500*K
Spot Lights -Recessed Round light. 4000K-6500*K .. (5W-9W) (For OFFICE- MEETING ROOM).
SURFACE MOUNTED (For Staircase area) LED PANEL LIGHT -600 x 600 40W - 6000*/6500*K
SURFACE MOUNTED (For Toilet area) LED PANEL LIGHT - 9'' x 9" 20W - 6000*/6500*K
40 watt LED Linear Light.-Surface Mounted (For Technical Area).
SAFETY SIGNS
General Warning
Electrical Hazard
Hot surface Hazard
Compressed Gas
Non-Flammable Gas
Entry
EARTHING SYSTEM SUITABLE TO DELIVER MAXIMUM VALUE OF 0.5 OHMS AT EACH PIT & ALMOST ZERO AT COMMON EARTH BUS. EARTH PIT : COPPER ELECTRODE :With 600mm x 600mm, 3.15 mm thick earth electrode plate including necessary materials like side fill compound etc. as required with standards brick masonary chamber with C.I hinged cover and watering arrangement. Complete as per IS:3043, 1996 Code Of Practice for Earthing. With value of 1 ohm. max.
EARTH PIT : GI ELECTRODE :With 600mm x 600mm, 6.30 mm thick earth electrode plate including necessary materials like side fill compound etc. as required with standards brick masonary chamber with C.I hinged cover and watering arrangement. Complete as per IS:3043, 1996 Code Of Practice for Earthing. With value of 1 ohm. max.
Chemical type Maint Free Earth . Using Copper Electrodes, Compounds etc.. Pipe In Pipe Technology. OD: 76mm. & ID: 42mm. Approx.Complete with Chamber, Chamber cover etc.Vendor to submit detailed Technical Offer.
Chemical type Maint Free Earth . Using Copper Electrodes, Compounds etc.. Pipe In Pipe Technology. OD: 48mm. & ID: 26mm. Approx.Complete with Chamber, Chamber cover etc.Vendor to submit detailed Technical Offer.
Earthing Sensor with Alarm ( For Solvent Dispensing). Vendor to submit detailed Technical Offer.
EARTH CONNECTIVITIES : Supply, laying of hot dipped galvanized (GI)/copper bare earth conductor bar / flexible wire /strip of following sizes along the cable trenches or cable trays or fixing to walls or structures or buried individually in paved/unpaved areas but excluding civil work finishing after layering of earthing strips etc. The installation shall include drilling of holes, connection & supply of adequate lugs, clamping, hardware material, Welded joints shall be used for G.I. strips. Welded joints after welding shall be painted with anticorrosive black bitumen paint , applying anti corrosive primer paint and two coat each of bituminous paint for buried earth strip. Excavation & backfilling of soil for burying the strip wherever applicable is paid extra as per the rate of excavation and backfilling rate. Jumper 150 mm x 50 mm shall be provided at every 10 meter interval for main earthing strip under instruction of engg. in charge and jumper rate is in inclusive.
08 SWG- Bare Copper Wire.
10 SWG- Bare Copper Wire.
12 SWG- Bare Copper Wire.
08 SWG- Bare G. I. Wire.
10 SWG- Bare G. I. Wire.
25 x 6mm. Bare Copper Flat.
25 x 3mm. Bare Copper Flat. (For UPS)
50 x 5mm. Bare Copper Flat.
25 x 5mm. Insulated Copper Flat.
25 x 3mm. G. I. Flat.
32 x 6mm. G. I. Flat.
50 x 6mm. G. I. Flat.
Assorted Hardwares like , G. I. Nuts Bolts with washers etc.
Assorted Hardwares like , M. S. Nuts Bolts with washers etc.
Porcelain / Insulated Base- Holders. Std. Accessory for Mounting above Flat Conductors.
Supply , installation, testing and commissioning of earthing pit with 600 x 600 x 12 mm thick cast iron plate, earth bus / strip test link, G.I. Water pipe including excavation of soil supply and laying of salt and charcoal back filling, making masonry chamber C.I. cover for the chamber with frame as per detail shown in the drawing and as per IS 3043
Supply , installation, testing and commissioning of Cu Coated Pipe In Pipe Technology( Chemical Earthing) . Model T/19-3 meters – Outer electrode Dia.48.4X3.2 mm Inner Dia 26.9X2.6mm, filled with crystalline conductive material (CCM) electrode coated upto 80 – 100 micron with 2 Bags of Back Fill Compound (BFC) (25 Kgs. Each).The chamber size shall be 450 x 450 mm with C.I. manhole chamber etc ( Make :Micronite / Ashlok, Equv).
Supply and installation of roof conductor Strip complete with holes, nuts, bolts, welding the strip with proper overlap clamped to roof parapet or roof G.I.sheets
25 x 3 mm G.I. Strip for Earthing.(For Down Comer).
50 x 6 mm G.I. Strip for Earthing.(For Earth Grid )
5 segment 25mm dia hollow copper spike (air termination rod)for lightning protection with copper down rod and necessary fixing hardware for the building as per IS 2309, 1969
Safety Equipment's: Supply, Installation of below mention safety equipment including all labour and materials etc., complete as per directions of Engineer-In-Charge.
Rubber mat for 415V LT Panels As per IS 15652 - 2006 Class "A" 2mm Thick
Caution boards ( 415V each)
Danger notice board for the Low Voltage Installation
First aid box with standard items
Shock treatment chart as per electricity board
Supplying & erecting Jelly filled armoured Telephone Cable 20 pair with 0.5 mm dia.
Supplying, erecting & commissioning of telephone tag block with crone module suitable for 20 pairs as required.
Supplying and fixing of RJ-11/RJ-45 modular telephone socket with G.I. switch box, modular plate including connections as required.
Supplying, installing, testing & commissioning approved type Push button telephone instrument desk top/wall mount unit as per specification in approved manner. (Panasonic model No KX-TS 580)
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed PVC conduit as required for IP Phone.
IP Telephone Instrument.
24 Port PoE Network Switch’s, Gigabit Ethernet Web Smart chassis in a 1U form factor with 24 x 10/100/1000 PoE Base-T ports, 2 fixed SFP (1G) with internal power supply (192W PoE budget).
8 Port PoE Network Switch’s, Gigabit Ethernet Web Smart chassis in a 1U form factor with 24 x 10/100/1000 PoE Base-T ports, 2 fixed SFP (1G) with internal power supply (192W PoE budget).
12U wall mounted double section rack with acrylic glass door having 2 Nos. 90 CFM fans, cable managers, 5A Sockets, fuse, ON/OFF Switch, 1 Packet mounting hardware, etc.
Supply & fixing of CAT 6 , 24 Port Patch Panel loaded.
Supply & fixing of 2 Mtr. Patch cord.
Supply & fixing of 25mm PVC conduit with accessaries.
ACCESS CONTROL WORK
Cable Work: Supply and laying of cables including fixing accessories, tray, trunking, conduits, saddles, clamps, ties, tags, termination of cables etc. Cable length and quantity are to be finally worked out by contractor at site based on actual measurements.Laying shall be inclusive of supply of wires, providing tray, trunking, galvanized steel tubes (conduit) / trunking, pull wires, tees / bends / elbows, junction / pull out boxes, etc., clamps / saddles for conduit clamping with all accessories & hardwares as required.
2C x 1.0 sqmm FR Mylan Shielded copper , multistrand, twisted pairs, PVC,non armoured wires having fire retarded low smoke insulation.
4C x 1.0 sqmm FR Mylan Shielded copper , multistrand, twisted pairs, PVC,non armoured wires having fire retarded low smoke insulation.
14 gauge, 25 mm Heavy duty PVC conduit
Cat 6 Cable
Cable Tray 150x50 mm (WXH),Cable tray- 2.0 mm thick,Type - Hot Dipped Galvanised Perforated Trays. Vendor shall supply tray joining plates, nut bolts, washers etc.
Cable Tray 50x25 mm (WXH),Cable tray- 2.0 mm thick,Type - Hot Dipped Galvanised Perforated Trays. Vendor shall supply tray joining plates, nut bolts, washers etc.
3 core 1.5 Sqmm power cable for ACS controller
FIXED DOME CAMERA Supply, Installation, Testing & Commissioning of Dome IR Color Indoor Day/Night, 6Megapixel CMOS , Pixel 1280(H)*960(V), 25/30 fps @720P, High speed, long distance realtime transmission , Day/Night and IR upto 30-40 mtrs, D-WDR, BLC, 2D-DNR , 2.8 to 12mm varifocal lens , Smart IR , Can connecto to Existing DVR and Any HD DVR, including power supply. Camera shall be suitable to install on wall / ceiling / Sheet panel.
Supply, Installation, Testing & Commissioning of IP Based NVR Watertight Bullet Camera. : • 6 Megapixel 1/3” CMOS Sensor in High Resolution, H.264/MJPEG Dual Codec & Streaming , 1920x1440@22fps /1080P (1920x1080@30fps), Digital Powerful WDR, 3D Noise Reduction, 2 Way Audio Supported.Up to 30 m IR range, 2.8 mm to 12 mm motorized vari-focal lens. • Intelligent Video Analytics, Micro SD Card Supported (SDHC up to 32GB), PoE Power Over Ethernet IEEE802.3af, CE, FCC Class A, RoHS, IP66, UL, ON/VIF Supported.
Supply, Installation, Testing & Comissioning of 48 port giga Network switch based on PoE. With Racks
16 CH DVR Supply, Installation, Testing & Commissioning of standalon 16 channel Tribrid -DVR supports HD Cameras /Analog/IP Video input, H.264 dual-stream video compression, All channel 720P real-time @ 16 frames per second (or 1080P non-realtime) recording Hard disk slot upto 4 SATA, 2 USB port, PTZ Camera Suupport, HDMI/VGA simultaneous video output 4 channel, smart search, Video Loss Alert, HDD Failure Alert, VQD Alert . To obtain 30 days live recording storage with 25% buffer
Supply, Installation, Testing & Comissioning of 10 TB SATA surveillance hard disc.for 30 Days recording .
Supply, Installation, Testing, Commissioning of 9 U rack for NVR with necessary Hardware.
CAT-6-UTP ARMOURED VIDEO CABLE Supply & laying of armoured CAT-6-UTP Video cable with required accessories like cable tie, screws, raval plugs, saddles as per site requirement.
OPTICAL FIBER CABLE Supply & laying of armoured OFC cable with required accessories like cable tie, screws, raval plugs, saddles as per site requirement.
Supply & Installation of GI perporated cable tray,HEAVY DUTY 14 gauge - 25 mm PVC Conduits along with support and accessories
Supply, Installation, Testing & Comissioning of Video Management Software Workstaion with 24" monitor (As per Application Specifiacation )
Testing & Commissioning support for CCTV system hook up with existing system.
ask enterprises
RAJSHREE CONSTRUCTION CONSORTIUM
SUNIL CONSTRUCTION
kamal enterprises
PIYUSH ENTERPRISES
arcoma
Pawan Construction Company
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.80 MB
ActrecAnimalFacilityPLANSSECTIONSELEVATIONREVISEDPROPOSAL.pdf
Additional Documents • 0.54 MB
BOQ_823261.xls
BOQ • 0.61 MB
ActrecAnimalFacilityELEVATION.pdf
Additional Documents • 0.56 MB
TD.pdf
Tender Documents • 3.55 MB
AnimalFacilityElevation2.pdf
Additional Documents • 0.54 MB
Animalfaciliyplan.pdf
Additional Documents • 0.27 MB
AnimalFacilitySection.pdf
Additional Documents • 0.62 MB
Animalfacilitydrawingrev1a.pdf
Additional Documents • 0.47 MB
AnimalFacilityFirstFloorplan.pdf
Additional Documents • 0.23 MB
AnnexureForm.xls
Additional Documents • 0.12 MB
AnimalFacilityGroundFloorplan.pdf
Additional Documents • 0.30 MB
AnimalFacilitySecondFloorplan.pdf
Additional Documents • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .