| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.1 LAccepted-Finance | L1 | Accepted-Finance ELIGIBLE | |
| 2 | L2₹13.5 L+₹1.4 L (11.9%)Accepted-Finance | L2 | Accepted-Finance ELIGIBLE | |
| 3 | L3₹14.6 L+₹2.5 L (20.8%)Accepted-Finance | L3 | Accepted-Finance ELIGIBLE | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Others-Lacking on experience | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Others-Experience is not according to the SBD of the tender |
Tender Value
₹16.2 L
EMD Value
₹32,500
Closing Date
3 Jul 2023, 4:00 pmClosed
Executive Engineer, ED Doda
Office of the Executive Engineer, ED Doda
CREATION OF 100 KVA SUB STATIONS ALONG WITH HT LT NETWORK WITH SITC FOR STAGE 0 AND STAGE I OF W S S PERNOTE LIFT
2023_PDD_215572_1
ED Doda/JPDCL/12 of 2023-24
Open Tender
Electrical Works
Turn-key
45 days
ED DODA
KINDLY REFER TO THE NIT AND SBD
3 documents required · 3 mandatory
₹1,000
Executive Engineer, ED Doda
₹32,500
17 Jul 2023
8 Jun 2023
4 Jul 2023
8 Jun 2023
3 Jul 2023
8 Jun 2023
SITC of 11/0.433kV, 100 KVA 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Au. wound ), and with LV Cable Box having detachable Aluminium Gland plate
SITC of Gapless Surge Arrestor, 9 kV, 10 kA, LA with polymer housing, Stn. Type
SITC of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
SITC of 11 kV Horn Gap Fuse Set 3 Phase 200A
SITC of 185 mm² (2CKt)/120mm² (2Ckt) Single Phase Cable, 1.1K V Grade, PVC Insulated Stranded Conductor FRLS type
SITC of 50mm² AB LT Cable (3x50 + 1x16+1X36 mm2) XLPE (11KV, 3C + Earth)
SITC of 30mm2 ACSR Conductor
SITC of 9 Mtr. Long Pole, (ST-410 SP33)
SITC of 8 Mtr. Long Pole, (ST-410 SP15)
SITC of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
SITC of GI Channel/Angle/Flat of sizes including clamps
STIC of Suspension/Tension Clamp with eye hook
SITC of Nuts and Bolts.
SITC of Earthing of substation--Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
SITC of Earthing Complete by G.I Pipe 40mm or GI Rod 20mm 2.5 mtr long through G.I Strips
SITC of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
SITC of LT Distribution Box for 100/63 kVA DTR with MCCB for incomer & SFU's for Outgoing Circuits
SITC of Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
SITC of Straight through Jointing Kit
SITC of Anti Climbing Device with Clamps
SITC of Wedge Connectors / PG Clamps
SITC of Danger Plates with Clamps
SITC of GI Barbed Wire for Anti Climbing
SITC of CT/PT Unit with 3-Ø, 4-Wire Trivector Meter (110/5 Amp)
SITC of Cement Bottoming 1:2:4 mix as per REC standards .45cum/ pole
SITC of Painting of Poles Red Oxide
SITC of Painting of Poles Aluminium Paint
Malik Brothers Electrical Contractor and Suppliers
M/S RATHER CONSTRUCTIONS AND TRADERS
Malik Brothers Electrical Contractor and Suppliers
Daya Krishan Raina
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .