Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.4 LAccepted-AOC 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L1 | Accepted-AOC Being the lowest | |
| 2 | L2₹5.8 L+₹16,953 (2.99%)Rejected-AOC | L2 | Rejected-AOC Not being the lowest | |
| 3 | L3₹6.2 L+₹50,230.50 (8.87%)Rejected-AOC | L3 | Rejected-AOC Not being the lowest | |
| 4 | L4₹6.4 L+₹75,214.50 (13.3%)Rejected-AOC | L4 | Rejected-AOC Not being the lowest |
Tender Value
₹8.5 L
EMD Value
₹17,000
Closing Date
30 Nov 2021, 6:00 pmClosed
AGE (I) AF Sonegaon, Nagpur
Bldg No. P-51, 44 wing Air Force Station, Sonegaon, Nagpur 440 005
REPAIR MAINT OF LED SECURITY STREET LIGHTS AND OTHER CONNECTED ITEMS IN TXR AND DOMESTIC AREA AT SONEGAON
2021_MES_486244_1
8408/E8
Open Tender
Civil Works
Item Rate
180 days
AGE (I) AF Sonegaon
As per NIT
7 documents required · 7 mandatory
₹500
AGE (I) AF Sonegaon
₹17,000
Yes
23 Dec 2021
3 Nov 2021
6 Dec 2021
3 Nov 2021
30 Nov 2021
17 Nov 2021
3 Nov 2021 - 17 Nov 2021
Amount
Taking down carefully unserviceable LED Street light/ flood light/Industrial light fittings 70 to 200 watt carefully from towers and upto 10 meter poles, after disconnecting the supply, sealing the cable ends for carrying out repairs/maintenance at site/workshop complete all as specified and directed.
Taking down carefully unserviceable LED building security light fittings 20 watt carefully from towers and upto 10 meter poles, after disconnecting the supply, sealing the cable ends for carrying out repairs/maintenance at site/workshop complete all as specified and directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation of poles, stays, laying of UG cable/ pipes & getting out in soft/loose soil complete all as specified and as directed.
Removing excavated material (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed.
M & L for providing dry river sand as in sand cushioning for underground cable protection including punning down sand in layers complete all as specified & directed Note: Only punned thickness of sand shall be considered for measurement purposes
Supplying and laying common burnt clay sub class ‘B’ bricks of size 230 mm x 115 mm x 75 mm, laid perpendicular to axis of cable for protection of LT cables complete all as specified and directed.
M & L road cutting of size 30 cm width x 45 cm depth for laying of cables including making good the road with necessary returning filling and bituminious portion with concrete and bituminous mixture and cemented portion with PCC in 1:2:4 , 15 cm thick from top and matching with the existing surfaces complete all as specified and directed.
Supplying and laying GI pipe Light grade (ISI marked) 50mm bore with connecting accessories, laid under road/ drain/fixed on wall etc for protection of cables including taking down complete all as specified and directed
Supplying, laying, testing and Commissioning cable XLPE insulated aluminium conductor,stranded, armoured, PVC sheathed, LT 1100 volt grade, heavy duty as per IS-7098 and providing suitable lugs and cable glands, laid in trenches/ ducts/fixed to wall/ roof/ poles including taking down existing cables complete all as specified and directed for the following sizes.
16 sqmm, 4 core
16 sqmm, 2 core
M & L for writing Pole No on PCC/steel poles with white synthetic enamelled paint on black background, size of letter shall be 50 mm or less complete all as specified and directed.
S&F LED street light fittings with surge protector & Die cast aluminium housing with IP65 protection with LED as symmetric for 70 watt inclusive of LED lamp & suitable capacity of control gear box/driver and suitable flexible wiring with 0.5 sq mm PVC insulated copper cable through and including fixing on pole with suitable MS flat iron bracket or GI pipe in angle complete all as specified and directed. Make-CG cat no LST-70-CDL-M or its equivalent make in PHILIPS, WIPRO, BAJAJ
S&F LED Flood light fittings with surge protector & Die cast aluminium housing with IP65 protection with LED as symmetric for 200 watt inclusive of LED lamp & suitable capacity of control gear box/driver and suitable flexible wiring with 0.5 sq mm PVC insulated copper cable through and including fixing on pole with suitable MS flat iron bracket or GI pipe in angle complete all as specified and directed. Make-CG cat no LFLN-200-CDL/60-M or its equivalent make in PHILIPS, WIPRO, BAJAJ
S&F LED Industrial movable rectangular LED highbay with excellent heat sink for thermal management alongwith surge protector & Die cast aluminium housing with IP66 protection with LED as symmetric for 80 watt inclusive of LED lamp & suitable capacity of control gear box/driver and suitable flexible wiring with 0.5 sq mm PVC insulated copper cable through and including fixing on pole/channel in hanger with suitable MS flat iron bracket or GI pipe in angle complete all as specified and directed. Make-CG cat no LHB-80-CDL/60-M or its equivalent make in PHILIPS, WIPRO
S&F LED Industrial movable rectangular LED highbay with excellent heat sink alongwith surge protector & Die cast aluminium housing with IP66 protection with LED as symmetric for 150 watt inclusive of LED lamp & suitable capacity of control gear box/driver and suitable flexible wiring with 0.5 sq mm PVC insulated copper cable through and including fixing on pole with suitable MS flat iron bracket or GI pipe in angle complete all as specified and directed. Make-CG cat no LHB11-150CDL/60-M or its equivalent make in PHILIPS, WIPRO
S & F 20 Watt LED Building security light with a nominal system. The luminaire shall have rated system lifetime of 50,000 burning hours at L70. The luminaire should have cool white colour , temperature (CCT>5000K) and a CRI>70. The luminaire shall meet IP66 rating with THD<20% & pf>0.9. The luminaire housing should be made of pressure die cast aluminimum. The total power consumption should not exceed 25W (including driver) pre wired fitted on and including two Nos PVC block of suitable size and connection up to tube light fitting with connecting up with copper 3 core flexible cord of minimum size 0.5 Sqmm size and testing complete including LED lamp, complete all as specified and as directed. Make : CG CAT No.LST-20-CDL-M or its equivalent make in PHILIPS, WIPRO, BAJAJ
S&F in repairs Isolator TPN 415 volts 63 Amp AC with necessary connection in existing panel/DB BOX complete all as specified and directed.
S&F in repairs Isolator DP 240 volts 40 Amp AC with necessary connection in existing pannel/DB BOX complete all as specified and directed.
S&F in repairs MCCBs four pole 415 volts. 16 KA ,100 Amp AC in existing panel board with modification /fabrication of existing panel board as directed by E-in-Charge complete all as specified and directed.
S & F Thermo plastic cable looping boxes, factory made, IP 65 sheet of size 200 x 160 x 98mm seperate detached gland plate and including MCB TPN 20 Amps and bakelite connector 4 way 20 Amp with din rail, weather vermin proof, front door opening with hinge and locking arrangement fixed to pole complete all as specified and directed.
S & F PVC insulated multistranded copper cable of size 1.5Sqmm for junction box to street light fitting complete all as specified and directed. Note : 2 run of cable shall be measures as one unit.
S & F Stove enamelled black rigid steel conduit 20mm, welded exclusive of junction box, but inclusive of all fitting such as tees, bends, elbow, reducer, bell mouth tube ends and all fixing accesssories such as couplers, lock nuts, pipe hook etc complete all as specified and directed.
M & L for clamps fabricated out of flat iron 40mm x 5mm / 50mm x 5mm drilled, welded, bent to shape, made in two halves suitable for steel tubular/ PCC poles including nuts, bolts, washers and painting one primer coat of red oxide zinc chrome primer and two final coats of aluminium paint complete all as specified and directed.
shanti enterprises
chronicle enterprises
Alert Multipurpose Services
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .