Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.8 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST AND REASONABLE | |
| 2 | L2₹50.6 L+₹4.2 L (9.10%)Rejected-Finance 107 1F TOLLYGUNGE ROAD KOLKATA 700026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | L2 | Rejected-Finance BEING NOT LOWEST AND REASONABLE | |
| 3 | L3₹52.0 L+₹5.7 L (12.2%)Rejected-Finance AMLA TOLA DISTT KATIHAR BIHAR 854105 | KATIHAR | BIHAR | 854105 | L3 | Rejected-Finance BEING NOT LOWEST AND REASONABLE | |
| 4 | Rejected-Technical | - | Rejected-Technical As mention in Technical Evaluation report |
Tender Value
Refer Docs
EMD Value
₹1.1 L
Closing Date
17 Mar 2021, 6:00 pmClosed
CWE KOLKATA
Headquarters commander Works Engineers Military Engineer Services No 1, National Library Avenue Alipore, Kolkata 700 027
SPECIAL REPAIR TO BLDG NO O-12 UNDER GE (FW) KOLKATA
2021_MES_411363_3
8104/E45(E-8)/20-21
Open Tender
Civil Works
Item Rate
180 days
FW KOLKATA
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
Yes
GE FW KOLKATA
₹1.1 L
Yes
15 Apr 2021
25 Feb 2021
19 Mar 2021
25 Feb 2021
17 Mar 2021
5 Mar 2021
25 Feb 2021 - 3 Mar 2021
Amount
NOTES :(i)The bidders/contractors are advised to read tender document & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates. (ii) It is highlighted that the cretin condition of General Condition Of Contracts (IAFW-2249) has been modified as direction of MOD i.e inclusion of performance security, deletion of risk & cost provisions and increase in defects liability period all as specified in tender document. The tenderers should keep in mind while quoting their offer
Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, pillars etc and disposal of debris and rubbish to a distance n.exc 100m as directed by the Engr-in-Charge.
Demolition of cement concrete( reinforced) of any description and in any position not otherwise specifically provided for complete all as specified & directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified & directed.
Demolition of stone slabs and tiles of any description or thickness in floors/vertical surfaces, etc laid, bedded and pointed in any mortar, etc complete all as specifed and directed by Engineer-in-charge.
Material and labour for dark shade /double charged Vetrified Ceramic tiles 10mm thick (square/rectangular) polished, area of each tiles exceeding 0.70 sqm but not exceeding 1.30 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
All as per item no 06 here in before but light shade/double charged Vetrified Ceramic tiles complete all as specified & directed.
All as per item no 06 here in before but area of each tiles exc 0.36 sqm but not exceeding 0.42 sqm, in floors etc,complete all as specified & directed.
All as per item no 06 here in before but as in skirting,dado etc with 10 mm thick backing coat in CM (1:4) complete all as specified & directed.
Material and labour for ceramic non skid coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors etc., laid over and including 15 mm thick screed bed in cement mortar 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match the tile surface all as specified and directed.
Supply and fixing glazed ceramic colour tiles (450x300 x 7mm thick ) on dado & skirting , set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick cement plaster with rough finished in cement mortar 1:3 to received tile complete all as specified and directed.
Supply and fixing glazed ceramic coloured tiles (300x 200x7mm thick) in vertical surface set and jointed in neat cement slurry and pointed in white or colour cement to match including 10 mm thick cement plaster with rough finished in cement mortar 1:3 to received tile complete all as specified and directed.
Material and labour for granite stone slab (of any type) 18 to 20 mm thick, machine cut ,bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including 15 mm thick screed bed in cement mortor 1:6 & cutting, polishing and making moulds on edges as in steps, jambs, pillars, window cills, cooking platforms, urinal partition,counter top and like complete all as specified and directed.
Material and labour for machine cut kota stone slab flooring 20-25 mm thick over 15mm thick screed bed in CM (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and as directed by the Engr-in-Charge
Material and labour for white Marble work (Makrana White) 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like laid over 15mm thick screed bed in CM (1:4) ,jointing and pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble complete all as specified and directed.
Material and labour for Granite (of any type,shedes,design pattern) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing over 20 mm thick screed bed in cement mortor 1:6 complete all as specified and directed.
Dismantling boarding of any description fixed in any position with nails complete all as specified and as directed.
Dismantling timber scantlings 40 Sq.cm and over in section, in any position complete all as specified and directed.
Material and labour for 1st class hard wood as in scantlings, wrought, in framed work (for bar counters post,counter edges of bar counters) complete all as specified and directed
Material and labour for second class hardwood, scantlings, clean sawn, in framed work complete all as specified and directed.
Supply and fixing 25mm thick boarding (1st class hard wood) planed one side with butt joints for bar counter top fixed with screws on curved surfaces complete all as specified & directed.
Supply and fixing 15mm thick boarding (1st class hard wood) planed one side with butt joints, joints are chamfered on both sides and the boarding is matched, fixed with screws on curved surfaces for bar counter front vertical face complete all as specified & directed.
Supply and fixing 15mm thick boarding (1st class hard wood) planed one side with butt joints, joints are chamfered on both sides and the boarding is matched, fixed with screws on the top of bar counter complete all as specified & directed.
Chamferes,splays,grooves,rebates,rounded angles,rounded nosings,tongued and grooved edges (each tongue and each groove measured), mouldings of edges etc exc 75mm but not exc 200mm girth in hard wood complete all as specified & directed.
Material and labour for 15mm thick boarding of 1st class hard wood planed one side with butt joints,joints are chamfered both sides and the boarding is matched, fixed with screws as in bar counter inner tiers complete all as specified & directed.
Dismantling steel work including gates, rafter, purlin, roof truss etc complete all as specified & as directed.
Material & labour for MS rolled sections as in in roof truss (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) and fixed with angle cleats, Fe-410-W(Gde-E 250) Quality ' A Complete all as specified and as directed. Note:- The drawing of truss shall be approved by the GE prior to incorporation in the work.
Dismantling corrugated AC sheeting in roof covering including ridges complete all as specified & as directed.
Supply and fixing of pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick and pitch length 75 mm c/c of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Supply and fixing of pre-painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in ridges, tips, valley, gutters, length & girth as fixed with nail or screws complete all as specified and as directed.
Dismentling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified & directed.
Supplying & fixing GI snap grid ceiling of grid size 605mm x 605mm , made of GI main Tee of section 36mm x 25mm x 1.40mm, cross Tee of section 23.50mm x 23.50mm x 1.40mm thick and angle of section 25mm x 25mm x 1.40mm thick including hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long for providing board complete all as specified and directed by the Engr-in-Charge.
Supply and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface over metal frame work and reinforced with G.I. wire mesh complete all as specified and directed
All as per item no 33 here in before but on curved surfaces
Taking down chowkats or frames with shutter (without taking off shutters from the frame but exc 1.50 qm and n exc 4.0 Sqm each complete all as specified and as directed by Engineer-in-Charge.
Taking down chowkats or frames n.exc 1.50 sqm each with shutters (without taking off shutters from the frames) complete all as specified & directed.
Material and labour for 2nd class hard wood plain solid,staight chowkats and frames,wrought, framed rebated on the solid rounded or chamfered,put together with glue pinned at joints complete all as specified & directed.
Material and labour for 18/19 mm thick, Block boards, grade 2 quality, interior grade, decorative type with decorative face veneer on one face, fixed with screw to timber frame work as in cup board,drawer etc complete all as specified and directed.
Suopply and fixing decorative laminate 0.90 mm thick ,type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per anufacturer's instructions complete all as specified & directed.
Supply and fixing continuous (piano) hinges of brass, bright finish ,width of flap 30mm when opened complete all as directed by the Engineer-in-Charge.
Supply and fixing 75 mm long brass handles cast type ,polished bright complete all as directed by the Engineer-in-Charge.
Supply and fixing 75 mm long rim latch of brass body with two levers, polished bright; with brass knob or lever handle complete all as specified and directed.
Supply and fixing 4 levers brass body, lock ,drawer graded 1 size 50 mm, complete all as directed by the Engineer-in-Charge.
Supply and fixing cupboard magnets heavey duty complete all as specified & directed.
Supply and fixing 125mm long brass barrel tower bolts of extruded section, with barrel of extruted section complete all as specified & directed.
Use and waste of formwork to side and soffits of floor or roof beams , beam haunching , girders , bressum-mers , lintels , cantilevers , shelves including supports , overhangs etc. also splays between floors and beams etc. ,rough finished flat surface of concrete complete all as specified and directed .
Use and waste of form work to soffits of suspended slab such as roof slab, floor slab, landing and similar work not exceeding 200mm thick surface horizontal or sloping, fair finished surface of concrete complete all as specified and directed.
Use and waste of formwork to chullah hoods, cha- jjas, troughs and similar items in- cluding edges for fair finishe of surface complete all as specified & directed.
Use and waste of formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter complete all as specified & directed.
Supply and fixing Mild steel TMT bars 10 mm dia and over cut to length and bent to shape as reqd, including cranking , bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed ) not less than 0.90 mm dia complete all as specified and directed .
All as per item No 50 here-in-before but 6mm to 8 mm dia as in stirrups, spacers, binders, complete all as specified and as directed.
Material and labour for reinforced cement concrete 1:1.5:3(nominal mix) type A1 (using 20 mm graded stone aggregate) as in beams, cantilevers, lintels over 1.5m span complete all as specified and directed. (Note : Reinforcement will be measured & paid seperately)
Material and labour for reinforced cement concrete 1:1.5:3(nominal mix) type A1 (using 20 mm graded stone aggregate) as in slab supported on walls,beams and columns in roofs,landings, balconies,canopies,deck slabs and in shelves and like complete all as specified & directed.
Material and labour for reinforced cement concrete 1:1.5:3(nominal mix) type A1 (using 20 mm graded stone aggregate) as in Chajjas complete all as specified & directed.
Material and labour for reinforced cement concrete 1:1.5:3(nominal mix) type A1 (using 20 mm graded stone aggregate) as in Fins, fascias, louvres, parapets, and railings exc. 60cm in height, newels, balustrade, and the like complete all as specified & directed.
Material and labour for Brick work with fly ash modular bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
Supply and fixing solid PVC wall lining 5mm thick plain/degined coloured PVC sheet inclusive of solvent cement and fixed at site on PVC frame complete all as specified & directed.
Material and labour for 5 mm thick PVC sheet fillet of width 35 mm at interval of 250 mm c/c fixed with 65 mm nicked cadmium scres @ 200 mm c/c for wall paneling inclusive of fixing on to wall to make PVC frame complete all as specified and directed.
Supply and fixing heavy duty double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel complete all as specified and directed.
Supply and fixing glass door consisting 10 mm thick toughened glass exc 1.75 sqm n.exc 2.50 sqm and mounted on heavy duty floor spring including all necessary fixing arrangments such as two pair of premium quality stainless steel 450 mm D haped handel(with making holes in the glass before toughnening), Heavy dutys tainless steel door lock preumium quality,( MAKE of door fittings: Heffle, hetich,Dorma, archies, door king, gurnish ) complete all as specified & directed.
Supply and fixing powder coated aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete all as specified and directed. Note : (a) Thickness of aluminium section shall not be less than 1.5 mm. (b) Anodizing shall be 15 micron conforming to IS-1868-1996 (c) Minimum thickness of powder coating 50 micron
Supply and fixing 5.5 mm thick sheet glass, ordinary quality and glazing with EPDM rubber in squares exc 0.5 sq. m in each pane complete all as specified & directed.
Supply and fixing in repair looking mirror 5.5mm thick glass including all sides rounded and bevelled to true surface fixed to wall with 5 mm th. Plywood and CP nut& bolt contersunk type complete all as specified & directed.
Material and labour for 2nd class hard wood designed and decorated fillets in section as required wrought fixed with screw, sectional area exc 13 and not exc 25 Scm complete all as specified & directed.
Supply and fixing 75mm thick 40 density flexipuff foam cushion,foam encased in white long cloth and covered with superior quality of leatherising cloth fixed with suitable material in bar counter as directed by Engr-in-Charge.
Supply and fixing granite composite (Silgranite) sink ( made up of 80% casting granite dust with 20% epoxy resin & hardner) 900 mm with drainage board in washing point with chromium plated brass sink faucet complete all as specified & directed.
Material and labour for two or more coats of French polishing including a coat of wood filler on new works on surfaces of any description, width or girth including cleaning and preparing the surface complete all as specified and directed.
All as per item no 67 here in before but one or more coats on old wodden surface complete all as specified & directed.
.Chipping of unsound /weak concrete materials including cover plaster from RCC structural member i.e. slabs , beams, columns ,lintel,chajja, fin , facia etc. 50 mm average thickness including tapering all edges, making square shoulders of cavities air or sand blasting etc and cleaning of exposed concrete surface of lightly picking materials by air blasting or sand blasting including foreign materials , loose concrete/aggregate etc and disposal of all debris out side of MOD land and complete all as specified and as directed by Engr-in-Charge.(Any storey/ height of building/ structure)
Chipping of unsound /weak concrete materials from RCC structural member i.e. slabs , beams, columns ,lintel,chajja, fin , facia etc. 60 mm average thickness including tapering all edges, making square shoulders of cavities air or sand blasting etc and cleaning of exposed concrete surface of lightly picking materials by air blasting or sand blasting including foreign materials , loose concrete/aggregate etc and disposal of all debris out side of MOD land and complete all as specified and as directed by Engr-in-Charge.(Any storey/ height of building/ structure)
Deduct / Add for below / over 5mm or part thereof thickness for item No 69&70(Any storey/ height of building/ structure) complete all as specified & directed.
Removing of concrete all around reinforcement bar upto 12 mm dia from behind the reinforcing bars average 25mm (but not less than 15mm air gap)by manual methods (using wire brushing ,chiselling etc) and applying chloride free rust removing chemical on rusting steel reinforcement bar and removing all rust from steel reinforcement bar by emery paper and cleaning the area throughly by water and allow it to dry and totally rust free of reinforcement bar all as complete as per manufacturer's instruction as specified and as directed .(Any storey/ height of building/ structure) Make( Rust removing chemical ):- Reebaklens RR of FOSROC or quivalents solutions SIKA/STP as approved by GE.
Material,labour and prepared existing reinforcement surface by brush and application two component epoxy zincrich primer on existing reinforcement surface of minimum specific gravity 1.75, adhesive bond strength with steel is 1.50N/mm2 and maximum coverage area 5.00 Sqm per litre complete all as specified and directed.(Any storey/ height of building/ structure) Make- Nitozinc primer of FOSROC or equivalents chemical given in approved make list of PS.
Material and labour for introducing new reinforcement bars upto 12 mm dia for structural connection in RCC beams, columns, lintel and slabs including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and upto 200mm including power drilling,fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges etc all as specified and directed (Any storey/ height of building/ structure).
Material , labour and placing in position free flow shrinkage cementitious micro concrete of compressive strength, flexural strength shall not be less than 50 MPa at 28 days , 5MPa at 28 days respectively for strengthening of beams, columns & other structural elements of average thickness 50mm and including surface preparation & suitabletype formwork etc. as per manufacturers instruction complete all as specified and as directed.. Make(micro concrete):-Renderoc RG of FOSROC or equivalents solutions SIKA/STP as approved by GE.
Material , labour and placing in position free flow shrinkage cementitious micro concrete of compressive strength, flexural strength shall not be less than 50 MPa at 28 days , 5MPa at 28 days respectively for strengthening of beams, columns & other structural elements of average thickness 60mm and including surface preparation & suitable type formwork etc. as per manufacturers instruction complete all as specified and as directed. . Make(micro concrete):- Renderoc RG of FOSROC or equivalents solutions SIKA/STP as approved by GE.
Deduct / Add for below / over 5mm or part thereof thickness for item No 75 to 76 complete all as specified & directed.
Supply and application cementitious grouting admixture with the cement slurry at a dosage 225 ml per bag of cement and injecting with high pressure by a pressure grouting pump through non return PVC nozzles prefix with rapid setting cementitious plugging mortar to fill all possible pores and gaps left within the old concrete mass. When the flow of grout stops or shows refusal or grout flows out from the adjacent nozzle, pumping to be stopped and the nozzle to be tied up and allowed to set for 24 hours. The PVC nozzles to be sealed off with quick-setting cementitious plugging mortar. Grouting operation to be carried out through next nozzle till the entire area is covered. The grouting holes to be finished by removing the protruded portion of nozzles and finishing flush with the surface, complete as per manufacturer's instruction as specified and as directed . (Any storey/ height of building/ structure) Make(Grouting admixture):- Cebex 100 of FOSROC or equivalents solutions SIKA/STP as approved by GE.
Material , labour and applying of high efficiency polymeric resin base film forming curing agent/compound over concrete surface and maximum coverage area 5.00 Sqm per litre as per manufacturers instruction complete all as specified and as directed. (Any storey/ height of building/ structure) Make:- Concure LP90 of FOSROC or equivalents solutions SIKA/STP/ Maruti / Choksey chemicals.
Providing and errecting double steel scaffolding system (cup lock type) on the exterior side of shaft portion (only) of building of any height including additional rows of scaffolding in stepped manner as per requirement of site, made with minimum 40mm dia M.S. Tube, placed 1.5 metre centre to centre(maximum), horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. Tube challis, M.S. Clamps and staircase system in the scaffolding for working platform etc. And maintaining it in a serviceable condition for execution of work and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of GE. Note:- (1) The elevational area of shaft portion of building ( length /breath of shaft X height of shaft) cover with scaffolding shall only be measured for payment purpose. (2) The payment shall be made once time only for execution of all items of each face of shaft portion of building. (3) After completion of work all scaffolding materials shall be removed from building /structure by the contractor and the same shall be the property of the contractor and accordingly rate shall be quoted.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water complete all as specified and directed
Material and labour for 15 mm thick rendering in cement mortar (1:6) to brick or concrete wall surfaces, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for 20 mm thick rendering in cement mortar on fair faces of brick work or concrete surfaces of wall in two layers, first layer 10mm thick in cement mortar (1:4) and top layers 10mm thick in cement mortar (1:4) using water proofing compound and finishing the surface even and smooth without using extra cement complete all as specified and as directed. Note : WPC shall be measurement and paid seperately)
Material and labour for 5mm thick rendering in CM 1:3 on fair faces of concrete surfaces as in ceilings, chajja etc including finishing the surfac even and smooth (without using extra cement) complete all as specified and directed .
Supply only liquid water proofing compound complete all as specified and directed. Make : Dr. Fixit LW 100, Sika, Fosroc
Material and labour for preparing newly plastered surfaces of internal walls, etc and applying two coats of acrylic washable distemper over a coat of alkali resistant primer including making good any undulations on the surfaces complete all as specified and as directed
All as per item no 86 here in before but on ceiling complete all as specified and directed.
Material and labour for preparing new plastered surfaces of walls by washing, rubbing down stopping of painted surfaces and applying two coats of water based acrylic weather proof exterior emulsion paint over a coat of primer, complete all as specified and as directed.
Material and labour for applying one coat of acrylic washable distemper to old decorated surfaces of walls including preparation of surfaces (by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss, efflorescent, salts, trading oil and greasy spots ) complete all as specified and as directed.
All as per item no 89 here in before but on ceiling complete all as specified and directed.
Material and labour for complete removal of existing treatment, washing, rubbing down old decorated surfaces of walls and applying two coats of water based acrylic weather proof exterior emulsion paint over a coat of primer, complete all as specified and as directed.
Dismantling of cast iron drain pipes, jointed in cement mortar of 100 mm internal dia complete all as specified and as directed by the Engr-in-Charge.
Supply and fixing 100mm dia Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed on walls complete all as specified & directed.
Supply and fixing cast iron bend 100mm bore (dia), any radius, diminishing Pieces or Tapers (Large Bore measured) and fitted with oval access doors including jointing with cement mortar 1:1, complete all as specified and as directed.
Supply and fixing cast iron branch piece 100mm bore (dia) single (equal or unequal), ordinary or inverted (spigot or socket type) with parallel branches fitted with oval access door including jointing with cement mortar 1:1, complete all as specified and directed.
Disconnecting existing tanks (exc 250 & n exc 500 ltrs capacity),setting aside for repairs,cleaning,etc and hoisting if required reconnecting and re-fixing in position.(Cleaning repairing,etc measured separately) complete all as specified & directed.
All as per item No.96 but exc 500 but n exc 1000 ltrs capacity.
All as per item No.96 but exc 1000 but n exc 2000 ltrs capacity.
Taking up or down steel Water Tubing 15mm bore including Connections and Fittings, Stacking properly at Site(s) for removing at site complete all as specified and as directed.
All as per item No.99 but 20mm dia bore complete all as specified and as directed.
All as per item No.99 but 25mm dia bore complete all as specified and as directed.
Supply and laying 15mm bore galvanised steel tubes, medium grade with all fitting and fixed to walls, ceiling, floors complete all as specified and as directed.
All as per item No.102 but 20mm bore pipe complete all as specified and as directed.
All as per item No.102 but 25mm bore pipe complete all as specified and as directed.
Taking out complete existing roof treatment from roof surface & roughening of old concrete floor/ wall surfaces including cleaning the roof surfaces by brushing sweeping etc and removing rubbish material complete all as specified and as directed.
Material and labour for 30mm thick plain cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in as base roof surfaces including finishing the surface even and smooth without using extra cement complete all as specified and directed.
Material and labour for water proofing treatment on existing cleaned RCC roof with the following specification and manufacturings instruction complete all as specified and as directed:- (a) Preparing and clening of fully dry surfaces as per IS3067-1966 (b) Applying bitumen primer conforming to IS:3384-1968 over the cleaned concrete/ plaster surface @ 0.5 Ltr per sqm (c) Applying a layer of APP based polymeric membrance 3.0mm thick (minimum) weight 3.0Kg per sqm (reinforced) with polyster Non woven fabric weighing not less than 160gms per sqm by torch application. The over laps shall be minimum 100mm on the transverse direction and 75 mm on longitudinal direction. (d) Applying one coat of aluminium paint @0.10 ltr per sqm over APP based polymeric membrane.
Taking down carefully existing aluminium/copper point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc excluding light fittings for taking credit removing from site and making good the disturbed surfaces of walls, Floors, ceilings etc to match with existing all as specified and directed.
Material and labour for concealed point wiring with FRLS PVC insulated unsheathed multistranded copper conductor cables of 1.5 sqmm size alongwith one earth continuity conductor with FRLS PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm size through and including PVC conduit terminated in modular switch boards for fixing of switches, sockets, fan regulators etc for the following [Note: - Modular switch boards shall be measured and paid separately]: - (a) One light point or one fan point or bell point controlled by one switch
(b) One 3 pin socket outlet, 5 Amp independent
(c) One 3 pin socket outlet, 5 Amp on the same board with other switches
All as per item No.109 above but wiring with FRLS PVC insulated unsheathed multistranded copper conductor cables of size 2.5 sqmm and cables of size 2.5 sqmm as continuous earth wire for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board complete all as specified and directed. [Note: - Modular switch boards shall be measured and paid separately]
Supply and fixing modular switch 1 way 6A, 1 Module 250 volts complete all as specified and as directed.
Supply and fixing modular switch 1 way 16A, 1 Module 250 volts complete all as specified and as directed.
Supply and fixing modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed.
Supply and fixing modular Socket, 6A/16A - 2/3 pin combined 2 module complete all as specified and directed.
Supply and fixing modular Fan step regulator, 120W - 2 module complete all as specified and directed
Supply and fixing modular Blank plate, 1 module
Supply and fixing modular White cover plate with frame, 3 module complete all as specified and directed
Supply and fixing modular White cover plate with frame, 8 module complete all as specified and directed
Supply and fixing modular White cover plate with frame, 12 module complete all as specified and directed
Supply and fixing modular Metal flush box 3 module complete all as specified and directed
Supply and fixing modular Metal flush box 8 module complete all as specified and directed
Supply and fixing modular Metal flush box 12 module complete all as specified and directed
Supply and fixing LED tube light fitting 20W, minimum colour temperature 6000K, surface mounted with suitable driver complete with all accessories internaly pre-wired and including connecting up with twin core twisted flexible copper conductor cable complete all as specified and directed.
Supply and fixing in repair LED down light fitting 10W as, minimum colour temperature 3000K, with suitable driver complete with all accessories internaly pre-wired and including connecting up with twin core twisted flexible copper conductor cable complete all as specified and directed. Make:- Philips type: DN092B LED10S-6500 PSU WH or equivalent make of Havells / Bajaj.
Supply and fixing LED strip light 22W, 5 mtr long role white / warm day light colour complete with accessories complete all as specified and directed. Make:- Havells /Bajaj / Philips .
Supply and fixing LED down hanging light fitting , shiny copper finish with white inside with E-27 LED 9Wx1 lamp complete with all accessories internaly pre-wired and including connecting up with twin core twisted flexible copper conductor cable complete all as specified and directed. Make:- Jaquar cat no JFO-COP-SLPEA069AE27 or equivalent make of Havells / Bajaj / Philips.
Supply and fixing in repair Decorative hanging light smokey glass with crystal, with E-14 LED Lamp 4Wx8 complete with all accessories internaly pre-wired and including connecting up with twin core twisted flexible copper conductor cable complete all as specified and directed. Make:- Jaquar cat no JES-CHR-CHL0008RPE14 or equivalent make of Havells / Bajaj / Philips.
Supply and fixing in repair Floor lamp with Wooden base and PVC shade, WE-27 LED 14Wx1 lamp complete with all accessories internaly pre-wired and including connecting up with twin core twisted flexible copper conductor cable complete all as specified and directed. Make:- Jaquar cat no STL-BLK-FL1093F or equivalent make of Havells / Bajaj / Philips.
Supply and fixing recess mounted spot focusing light fitting 6W with range of adjustable recessed spot lighting with multiple beam options, color temperature 4000pSU including suitable driver connected with insulated unsheathed flexible copper wire of suitable size (length not exceeding 0.5m) from ceiling rose complete all as specified and directed Make: Philips cat No DN311B LED6S-4000 PSU MB WH or equivalent model of Havells / Bajaj.
All as per item no 131 but Supply and fixing in repair complete all as specified and directed.
Supply and fixing BLDC ceiling fan ,3 star rating ,1200 mm sweep complete AC single phase 230 Volt 50 HZ connecting with flexible cable 3 core copper conductor of size 23/0.0076 of suitable length from ceiling rose to ceiling fan including all hanging arrangement complete all as specified and as directed.
Supply and fixing 40 mm bore GI tubing medium grade for hanging of ceiling fan complete all as specified and directed
Supply and fixing 15 mm bore GI tubing medium grade and making hole for extension of fan hook in high roof ceiling complete all as specified and directed.
Supply and fixing mild steel bands, straps, fan hooks, clamps, hold fasts, wall ties, flat iron fillets and similar work including necessary drilling bolting or riveting etc conforming to Fe – 290 Gde E – 165 complete all as specified and as directed.
Supply and fixing Ceiling rose three terminals polycarbonate , isolated body complete all as specified and directed.
Taking down unserviceable main switches, DBs, bus bars chambers including all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified and directed.
Supply and fixing sheet metal enclosure for MCB DB double door single pole & Neutral 8 way with common bus bar complete all as specified and directed.
Supply and fixing MCB 'C' series single pole (SP) 6 to 32 Amps, breaking capacity 10KA. ,240 volt complete all as specified and directed.
Supply and fixing MCB 'C' curve single pole neutral (SPN), 32 Amps with breaking capacity 10kA,240 volt complete all as specified and directed.
Supply and fixing MCB 'C' curve four pole , 63 Amps with breaking capacity 10kA, 240 volt complete all as specified and directed.
Material and labour for Sub main wiring with 2 run of 6 sqmm (Nominal area) single core cable FRLS PVC insulated, multistranded, unsheathed, copper conductor cables 1100 Volts grade drawn through PVC conduits/casing-caping of suitable size, fixed to wall/ceiling etc including one run of 6 sqmm (nominal area) single core, FRLS PVC insulated, multistranded, unsheathed, copper conductor as earth wire and duly connected to common earth point including PVC conduits/casing-caping of suitable size including taking down old sub main wiring complete all as specified and as directed by Engineer-in-charge. Note : PVC Conduits/Casing-caping, two run cables and one run of earth wire will be measured as one length.
All as per item no -143 here in before but sub main wiring with 4 run of FRLS PVC insulated and unsheathed multistranded copper conductor of nominal cross sectional area 4.00 sqmm alongwith two run of FRLS PVC insulated & unsheathed copper conductor of nominal cross sectional area 4.00 sqmm as earth continuity conductor drawn through & including PVC conduit of suitable size complete all as specified and directed. Note : PVC Conduits/Casing-caping, four run cables and two run of earth wire will be measured as one length.
All as per item no -143 here in before but sub main wiring with 2 run of FRLS PVC insulated and unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed copper conductor of nominal cross sectional area 4 sqmm as earth continuity conductor drawn through & including PVC conduit of suitable size complete all as specified and directed. Note : PVC Conduits/Casing-caping, two run cables and one run of earth wire will be measured as one length.
Supply and fixing Triple pole and earth enclosure with a three pin and earth plug and socket complete with one triple pole MCB complete all as specified and directed.
Supply and fixing in repair LED bollard light with IP65 protection rated inverted tripod type with soft 360 degree light distribution complete all as specified and directed. Make:- Crompton cat No LBLSN-10-CDL or equivalent model of Bajaj / Philips.
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
S.M.CONSTRUCTIONS
Prahalad Rai
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .