| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 LAccepted-AOC 26 NEW AVAS VIKAS COLONY DELHI ROAD SAHARANPUR UP | L1 | Accepted-AOC Accept due to being L1 | |
| 2 | L2₹3.0 L+₹36,829 (14.0%)Accepted-AOC | L2 | Accepted-AOC Reject due to not being L1 | |
| 3 | L3₹3.3 L+₹69,909 (26.6%)Accepted-AOC 67 PATEL NAGAR NEW MANDI MUZAFFARNAGAR INDEX NO C 630 HQ CE WC | L3 | Accepted-AOC Reject due to not being L1 | |
| 4 | L4₹3.6 L+₹96,909 (36.8%)Accepted-AOC | L4 | Accepted-AOC Reject due to not being L1 | |
| 5 | L5₹4.2 L+₹1.5 L (58.8%)Accepted-AOC | L5 | Accepted-AOC Reject due to not being L1 |
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
1 Feb 2021, 6:00 pmClosed
G E ROORKEE
G E ROORKEE
REPAIR CLEANING LAYING TO SEWAGE LINE MANHOLE SEPTIC TANKS ETC IN POCKET 9 IN B R III SAHARANPUR UNDER GE ROORKEE
2020_MES_402333_2
8391/982/E8
Open Tender
Civil Works
Item Rate
180 days
SAHARANPUR
AS PER NIT
6 documents required · 6 mandatory
₹300
G E ROORKEE
₹10,000
Yes
29 May 2021
22 Jan 2021
3 Feb 2021
22 Jan 2021
1 Feb 2021
25 Jan 2021
Amount
M&L for cleaning of blocked/ chocked pipe line of 100 mm dia from floor or gully trap or from cleaning eyes, up to Ist manhole in any depth by rodding or by mechanical means and well flushing the complete line up to Ist man hole including removing of sludge/ waste to low lying areas within 200 m distance and buring the same properly to the entire satisfaction of Engineer- in- Charge, with and including taking out and re-fixing of manhole covers duly set in cement mortar 1:4 as and where required complete all as specified and directed.
M&L for cleaning of blocked/ chocked pipe line of 150 mm dia from trap ( 'P' or 'S' ) or from cleaning eyes, up to Ist manhole in any depth by rodding or by mechanical means and well flushing the complete line up to Ist man hole including removing of sludge/ waste to low lying areas within 200 m distance and buring the same properly to the entire satisfaction of Engineer- in- Charge, with and including taking out and re-fixing of manhole covers duly set in cement mortar 1:4 as and where required complete all as specified and directed.
M&L for cleaning of blocked/ chocked pipe line of 75 mm dia from trap ( 'P' or 'S' ) or from cleaning eyes, up to Ist manhole in any depth by rodding or by mechanical means and well flushing the complete line up to Ist man hole including removing of sludge/ waste to low lying areas within 200 m distance and buring the same properly to the entire satisfaction of Engineer- in- Charge, with and including taking out and re-fixing of manhole covers duly set in cement mortar 1:4 as and where required complete all as specified and directed.
M&L for cleaning of blocked WC, Gully trap,Floor trap and Nahani trap incl cleaning branch piece from trap to connecting bend or juncition complete all as directed.
Taking off existing cover of septic tank, cesspool, soakwell, soakpit or manhole and Cleaning of septic tank including connecting chamber by pumping out sludge water incl taking out mud sludges from tank to remove a distance exc 50 mtr and not exc 100 mtr, placed in the trenches not less than 01 miter deep from ground level and incl refilling the trenches with excavated earth to cover sludges placed, all as directed by Engineer in charge Note : Excavation of trenches and disposal of surplus soil as deemed to be included in the quoted rates however qty of sludge and slude water in septic tank will be measured and paid complete all as specified & as directed.
M&L for Cleaning and removing all scale and dirt, etc, from PVC/RCC tanks capacity n.exc 500 Ltr and from mouths of circulating pipes incl clening with clean water complete all as specified.
M&L for Cleaning and removing all scale and dirt, etc, from PVC/RCC tanks capacity exc 500 and n.exc 1000 Ltr and from mouths of circulating pipes incl clening with clean water complete all as specified.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m depth for cesspit, manhole etc,and getting out in soft/loose soil even in foul position complete all as specified and directed.
Returning, filling in incl spreading levelling watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as directed.
Removing excavated material ( Soil ) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point
Demolition and breaking up of existing drain pipe (SGSW/PVC/RCC etc) set in cement mortar of internal dia of pipe 150 mm complete all as directed.
Demolition and breaking up of existing drain pipe (SGSW/PVC/RCC etc) set in cement mortar of internal dia of pipe 100 mm complete all as directed.
M&L for 150 mm bore PVC (SWR) pipes single socketed, in any length , laid in trenches and jointed with cement mortar complete all as specified and as directed.
M&L for 110 mm bore PVC (SWR) pipes single socketed, in any length , laid in trenches and jointed with cement mortar complete all as specified and as directed.
M&L PCC 1:3:6 type C-2 (using 40 mm graded aggregate) as in concrete bed to 150 mm bore drain pipe incl packing under haunching against the sides of pipes after pipe laid and tested complete all as specified and as directed.
M&L PCC 1:3:6 type C-2 (using 40 mm graded aggregate) as in concrete bed to 100 mm bore drain pipe incl packing under haunching against the sides of pipes after pipe laid and tested complete all as specified and as directed.
Demolition of brick work in built in cement mortar complete all as specified.
M & L for brick work with sub class ‘B’ bricks straight curved on plan exceeding 6 meter mean radious with old size bricks built in CM 1:4, complete all as specified & as directed.
All as per item 18 here-in-above but except bricks complete all as directed. Note :- Serviceable bricks obtained from demolition against item no 17 here-in-before shall be reused.
Taking down cement plaster any description on brick or stone walls, /RCC walls surfaces etc. including raking out joints, hacking for key, scrubbing down wih water, etc complete all as specified & as directed.
M&L 15 mm thick rendering including WPC in cement mortar 1:4 in side and wall of manhole of brick work/concrete surfaces finished even and smooth with out using extra cement complete all as specified & as directed. (Note:- Water proofing compound will be measured and paid for sapratly )
Supply only liquid water proofing compound complete all as specified & as directed.
Demolition of unrenforced cement concrete in ground floors and pavings n.exc 15 cm thickness below or above ground level complete all as specified & as directed.
M&L for PCC 1:3:6 type C-1 (20 mm graded aggregate) as in copping, benching of manhole / drain slightly rounded or chamfered angles and throating, as directed incl finish the surfaces smooth without using extra cement complete all as specified.
M & L Preparation of new surfaces of walls and apply three coat of white wash complete all as specified & as directed.
S&F in repair 110mm PVC (SWR) bends any radius complete all as specified & as directed.
S&F in repair 110 mm PVC (SWR) branch piece, double (double Y) equal or unequal with access door complete all as specified & as directed.
S&F in repair 110 mm PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified & as directed.
S&F in repair 75mm PVC (SWR) multi floor trap with grating including jointing with solvent cement including dismentling of old one and making the surface good complete all as specified.
S&F in repair 110 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls as rain water pipe and similar work including taking down old existing pipe complete all as specified & as directed.
S&F in repair 75 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls as vent pipe and similar work including taking down old existing pipecomplete all as specified & as directed.
Demolition of reinforced cement concrete as in cover slabs of manhole or septic tank, soak pit complete all as specified & as directed.
M&L for RCC 1:2:4, type B1 (using 20mm graded aggregate) Precast cement concrete as in cover slab for man hole and similar article with plain face. Set in cement mortar 1:4 complete all as specified & as directed.
M&L mild steel round bars 10 mm dia as in stiffner for straightning chain link fencing complete all as specified and directed.
RAM PRAKASH AND ASSOCIATES
VERDHMAN ASSOCIATES
JAIN BUILDERS
TANUJ SAINI CONTRACTOR
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .