Loading
Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹6.5 L
Closing Date
20 Feb 2025, 1:30 pmClosed
PR & CC
Refer tender
2400018866-HD-06000
5100018866
Open Tender
Unknown (Unspecified Location)
₹0
₹6.5 L
20 Feb 2025
29 Jan 2025
20 Feb 2025
20 Feb 2025
29 Jan 2025 - 10 Feb 2025
| Item No | Item Title | Description | Qty | Unit |
|---|---|---|---|---|
| 1 | TK-264 Painting & Insulation | TK-264 Painting & Insulation — nk-61-TK-264 Dia-18.5Mtr & Height-20Mtr.External painting (Shells/External surface of Cone Roof/ Spiral Stairways/ Cooling and f m system & other associatedfittings etc.) & Internal Painting (Tank Bottom/Shells/Internal surfaces & supports of Cone Roof/Gauge ll, TE, LT-1&2 Pipes &other internally associated fittings etc.) and Insulation of Tank along with installation and dismantling of etallic Scaffolding.For External Painting-a) External Surfaces: Surface preparation to SSPC-SP-10, application of primer nd paint on all external surfaces of tanks (except top side of cone roof of the tank and 200mm of lower bottom of 1st shell)i.e. e ernal shell, wind girders, shell appurtenances,associated structural steel works, ladders, walkways, platforms,handrails, spiral tairway as per painting system defined below and other requirements as specified in respective Engg data sheets, stencilling tank no capacity, name of stored product, paintingEmblem as per the attached sample, including supply of metallic and non-metallic materi s, primer and paint of approvedquality, providing scaffolding, labour, equipments, consumables, etc. to complete the work in all r pect as per applicablestandard specifications, standards attached elsewhere in the tender document and instructions of Engineer- i Charge. All materials shall be supplied by Contractor.Design Temperature range 81°C to 150°C: Primer : 1 coat of F-15@ 75micron T/coat,Finish Paint : 2 coat of F-15@ 75micron DFT/coatb) For External surface of Cone Roof and 200mm of lower bottom of 1st s ll - Surface preparation and application of thermal insulating coating HP-TIC as per attached technical data sheet and application c ck list.For thermal insulating coating HP-TIC only component A (resin + filler) will be supplied by HPCL and all other materials re in the vendor's scope.Vendor has to make all arrangements for storage and mixing and application of paint as per attached HP-TI technical data sheet and application check list.Thermal Insulating Coating- application of coats to achieve the final DFT of 5mm Finish paint- one coat of Polyurethane of 50micron.For Internal Painting- Internal Surfaces: Surface preparation to SSPC P-10, application of primer and paint on internal surface of bottom plate,internal surface of cone/dome roof, internal surface of re shell forfull height, support structure, roofstructure and internal ladders etc., structural steel, internal supports and int nal accessories (except heating coil) asper painting system defined below and requirements as given in the respective engg. data s ets. Supply of metallic andnon-metallic materials, labour, primer and paint of approved quality, equipments, consumables, etc. to mplete the work inall respect, as per applicable standard specifications, standards attached elsewhere in the tender document and structionsof Engineer- in-Charge. All materials shall be supplied by Contractor.Design Temperature range upto 150°C: Finish Pa t : 1 coat of F17 @ 375DFT /coatFor Insulation--Supply of all materials, application of hot insulation as per specification -44-0002) on outside surface of tank shell (except 200 mm of lower bottom of 1st shell) nozzles, manholes, appurtenances, attachment etc., including supply of all materials and installation of allinsulation supports as per Std. 7-13-0003 and completing the work i all respect as per drawings, specifications, standardsand instructions of Engineer-in- Charge. Insulation not required on tank roof For Insulation mastic vapour barrier quality shall be Ar-cryl CP-9 of Childers or CC-9 Weather Barrier Mastic of Capricorn Coatings Colours or Equivalent.All materials shall be supplied by Contractor.Insulation type: Ih & It (Rockwool) | - | Lump Sum |
| 2 | TK-313 Painting & Insulation | TK-313 Painting & Insulation — nk-61-TK-313 Dia-22Mtr & Height-20Mtr.External painting (Shells/External surface of Cone Roof/ Spiral Stairways/ Cooling and foa system & other associatedfittings etc.) & Internal Painting (Tank Bottom/Shells/Internal surfaces & supports of Cone Roof/Gauge we , TE, LT-1&2 Pipes &other internally associated fittings etc.) and Insulation of Tank along with installation and dismantling of M allic Scaffolding.For External Painting-a) External Surfaces: Surface preparation to SSPC-SP-10, application of primer a paint on all external surfaces of tanks (except top side of cone roof of the tank and 200mm of lower bottom of 1st shell)i.e. ext nal shell, wind girders, shell appurtenances,associated structural steel works, ladders, walkways, platforms,handrails, spiral s irway as per painting system defined below and otherrequirements as specified in respective Engg data sheets, stencilling tank no. capacity, name of stored product, paintingEmblem as per the attached sample, including supply of metallic and non-metallic materia , primer and paint of approvedquality, providing scaffolding, labour, equipments, consumables, etc. to complete the work in all re ect as per applicablestandard specifications, standards attached elsewhere in the tender document and instructions of Engineer- in harge. All materials shall be supplied by Contractor.Design Temperature range 81°C to 150°C: Primer : 1 coat of F-15@ 75micron DFT oat,Finish Paint : 2 coat of F-15@ 75micron DFT/coatb) For External surface of Cone Roof and 200mm of lower bottom of 1st shel - Surface preparation and application of thermal insulating coating HP-TIC as per attached technical data sheet and application chec list.For thermal insulating coating HP-TIC only component A (resin + filler) will be supplied by HPCL and all other materials ar in the vendor's scope.Vendor has to make all arrangements for storage and mixing and application of paint as per attached HP-TIC t hnical data sheet and application check list.Thermal Insulating Coating- application of coats to achieve the final DFT of 5mm. nish paint- one coat of Polyurethane of 50micron.For Internal Painting- Internal Surfaces: Surface preparation to SSPC-SP 0, application of primer and paint on internal surface of bottom plate,internal surface of cone/dome roof, internal surface of bar shell forfull height, support structure, roofstructure and internal ladders etc., structural steel, internal supports and intern accessories (except heating coil) asper painting system defined below and requirements as given in the respective engg. data shee . Supply of metallic andnon-metallic materials, labour, primer and paint of approved quality, equipments, consumables, etc. to com ete the work inall respect, as per applicable standard specifications, standards attached elsewhere in the tender document and ins uctionsof Engineer- in- Charge. All materials shall be supplied by Contractor.Design Temperature range upto 150°C: Finish Paint 1 coat of F17 @ 375DFT /coatFor Insulation--Supply of all materials, application of hot insulation as per specification (6- -0002) on outside surface of tank shell (except 200 mm of lower bottom of 1st shell) nozzles, manholes, appurtenances, attachments e ., including supply of all materials and installation of allinsulation supports as per Std. 7-13-0003 and completing the work in a respect as per drawings, specifications, standardsand instructions of Engineer-in-Charge. Insulation not required on tank roof. F Insulation mastic vapour barrier quality shall be Ar-cryl CP-9 of Childers or CC-9 Weather Barrier Mastic of Capricorn Coatings & C ours or Equivalent.All materials shall be supplied by Contractor.Insulation type: Ih & It (Rockwool) | - | Lump Sum |
| 3 | TK-314 Painting & Insulation | TK-314 Painting & Insulation — nk-61-TK-314 Dia-22.0Mtr & Height-20Mtr.External painting (Shells/External surface of Cone Roof/ Spiral Stairways/ Cooling and f m system & other associatedfittings etc.) & Internal Painting (Tank Bottom/Shells/Internal surfaces & supports of Cone Roof/Gauge ll, TE, LT-1&2 Pipes &other internally associated fittings etc.) and Insulation of Tank along with installation and dismantling of etallic Scaffolding.For External Painting-a) External Surfaces: Surface preparation to SSPC-SP-10, application of primer a paint on all external surfaces of tanks (except top side of cone roof of the tank and 200mm of lower bottom of 1st shell)i.e. ext nal shell, wind girders, shell appurtenances,associated structural steel works, ladders, walkways, platforms,handrails, spiral s irway as per painting system defined below and otherrequirements as specified in respective Engg data sheets, stencilling tank no. capacity, name of stored product, paintingEmblem as per the attached sample, including supply of metallic and non-metallic materia , primer and paint of approvedquality, providing scaffolding, labour, equipments, consumables, etc. to complete the work in all re ect as per applicablestandard specifications, standards attached elsewhere in the tender document and instructions of Engineer- in harge. All materials shall be supplied by Contractor.Design Temperature range 81°C to 150°C: Primer : 1 coat of F-15@ 75micron DFT oat,Finish Paint : 2 coat of F-15@ 75micron DFT/coatb) For External surface of Cone Roof and 200mm of lower bottom of 1st shel - Surface preparation and application of thermal insulating coating HP-TIC as per attached technical data sheet and application chec list.For thermal insulating coating HP-TIC only component A (resin + filler) will be supplied by HPCL and all other materials ar in the vendor's scope.Vendor has to make all arrangements for storage and mixing and application of paint as per attached HP-TIC t hnical data sheet and application check list.Thermal Insulating Coating- application of coats to achieve the final DFT of 5mm. Finish paint- one coat of Polyurethane of 50micron.For Internal Painting- Internal Surfaces: Surface preparation to SSPC- -10, application of primer and paint on internal surface of bottom plate,internal surface of cone/dome roof, internal surface of b e shell forfull height, support structure, roofstructure and internal ladders etc., structural steel, internal supports and inte al accessories (except heating coil) asper painting system defined below and requirements as given in the respective engg. data sh ts. Supply of metallic andnon-metallic materials, labour, primer and paint of approved quality, equipments, consumables, etc. to c plete the work inall respect, as per applicable standard specifications, standards attached elsewhere in the tender document and i tructionsof Engineer- in-Charge. All materials shall be supplied by Contractor.Design Temperature range upto 150°C: Finish Pai : 1 coat of F17 @ 375DFT /coatFor Insulation--Supply of all materials, application of hot insulation as per specification ( 44-0002) on outside surface of tank shell (except 200 mm of lower bottom of 1st shell) nozzles, manholes, appurtenances, attachments tc., including supply of all materials and installation of allinsulation supports as per Std. 7-13-0003 and completing the work in ll respect as per drawings, specifications, standardsand instructions of Engineer-in- Charge. Insulation not required on tank roof. or Insulation mastic vapour barrier quality shall be Ar-cryl CP-9 of Childers or CC-9 Weather Barrier Mastic of Capricorn Coatings & olours or Equivalent.All materials shall be supplied by Contractor.Insulation type: Ih & It (Rockwool) | - | Lump Sum |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
2400018866-HD-06000.pdf
TENDER_DOCUMENT • 25.50 MB
Download all tender documents and submit your bid