Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-Finance | ₹1.3 Cr | L1 | Accepted-Finance valid to be received. |
| 2 | L2₹1.3 Cr+₹5.5 L (4.40%)Accepted-Finance | ₹1.3 Cr+₹5.5 L (4.40%) | L2 | Accepted-Finance valid to be received. |
| 3 | Rejected-Technical | - | - | Rejected-Technical Hard copy not submitted as per tender terms and condition. |
Tender Value
₹96.0 L
EMD Value
₹1.9 L
Closing Date
15 May 2025, 2:00 pmClosed
The Exe. Engg., PWD, WD-I, Daman.
O/o the Ex. Eng., P.W.D., 2nd floor Multi office complex, near Veg. Market, Moti Daman.
Miscellaneous and Balance Electrical work of Aquarium, Museum and Kiosk Building, Garden Area at Devka Garden, Nani Daman. (E-11743)
2025_DAMAN_4214_1
Tender Notice No.14/2025-26
Open Tender
Civil Works - Others
Works
60 days
Daman Disrict.
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
The Exe. Engg., PWD, WD-I, Daman.
₹1.9 L
1 Jul 2025
29 Apr 2025
15 May 2025
29 Apr 2025
15 May 2025
29 Apr 2025
Items
MISCELLANEOUS WORK Material & labour filling gap in Track Gap with cement Mortar 1:1(1-Cement: 1- fine sand)
Providing and fixing factory made precast RCC treepit cover guard, having concrete of strength not less than M-25, of any size with reinforced as per direction of Engineer-in-chargefor (all leads & lifts) complete
ELECTRICAL Providing & erecting 240 V MCB double pole switch for motor & inductive load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity 6 to 32 Amp.
Providing & erecting 240 V MCB double pole switch for motor & inductive load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity 40 Amp. -
Providing & erecting 415 V MCB Tripple pole switch for motor & inductive load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity 6 to 32 Amp.
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity (a) 6 to 32 Amp. -
[b] 32A / 40A, 2 pole Single Phase
Half / One Module Blanking Plate of Standerd Size.
Internal Wiring WITH MODULAR TYPE SWITCHES Wiring of points to be done in open/concealed manner in 25 mm dia medium gauge Rigid PVC FRLS pipe. Wiring shall be done with FRLS type copper flexible wire of 650V/1100V. Separate pipe should be taken for circuit mains. Nos of ciruit of the same phases may be taken in same conduit (maximum 2 ckts).The circuit shall be laid in 25/40 mm dia medium gauge rigid PVC FRLS pipe. The point rate shall include all the necessary piping and wiring from sub panel / Distribution board to switch board & switch board to the batten holder / angle holder / connector / ceiling rose all inclusive except sub panel / Dist board. The wiring shall be done as per relevant prevailing standard. The looping of the wiring should be done in the switch boxes or light and fan point outlet boxes to avoid the junction boxes. The junction boxes and switch boxes for the ceiling light point, fan point etc shall be minimum 60/75 deep. All the necessary jarry in brick plastered walls should be done with machine cutter only , also jarry should be filled with cement, sand and wire mesh as required, the material cost for rough finish shall be included in point rate. Whenever pipes are required to be laid in flooring shall be of heavy guage.Wiring should be done as per distribtion details. Each circuit should have dedicated phase, neutral & earth wire. Wire sizes to be used as under For Light Points /fan point/ wall fan / 6A 3 Pin Plug - DB to SB - 2.5sqmm for Phase & Neutral & 1.5 sqmm for Earth - SB to Point - 1.5 sqmm for Phase & Neutral & Earth For 6A Plug point. - 1.5 sqmm for Phase, Neutral & Earth For 6/10/16A general purpose plug point - 2.5 sqmm for Phase, Neutral & 1.5 sqmm Earth For 16A plug point for A/C and Geyser - 4 Sqmm for Phase, Neutral & 2.5 sqmm Earth For 20/32A plug point - 6 sqmm for Phases, Neutral & 4 sqmm Earth For Light Points /fan point/ wall fan / 6A 3 Pin Plug - DB to SB - 2.5sqmm for Phase & Neutral & 1.5 sqmm for Earth - SB to Point - 1.5 sqmm for Phase & Neutral & Earth For 6A Plug point. - 1.5 sqmm for Phase, Neutral & Earth For 6/10/16A general purpose plug point - 2.5 sqmm for Phase, Neutral & 1.5 sqmm Earth For 16A plug point for A/C and Geyser - 4 Sqmm for Phase, Neutral & 2.5 sqmm Earth For 20/32A plug point - 6 sqmm for Phases, Neutral & 4 sqmm Earth No zarry will be allowed in expose brick work. The conduit shall be provided when the walls are under construction. The pipes in slab shall be laid before the slab is casted. One light point controlled by one single way 6 A switch.
Providing and erecting metallic vitrified danger notice board for MEDIUM VOLTAGE installation to be erected as per IS.
Cable Trench Marking trench in soft soil of suitable width of 90 cms. Deep for laying cable or locating the fault all over the run and back filling the same and making the surface as normal ground.
Cables Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables a) 4 core 6 Sq. mm
b) 4 core 10 Sq. mm
Cable Termination Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete without going tails, insulating tape etc for following size of cables. Also with Solderless crimping type Aluminium / copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. a) 4 core 6 Sq. mm
b) 4 core 10 Sq. mm
c) 4 core 16 Sq. mm
d) 4 core 25 Sq. mm
g) 3 core 4 Sq. mm
i) 3 core 10 Sq. mm
One light point controlled by two, two way 6 A switch
6/16A x 250 Volt switched socket outlet point for outside with 4 sq.mm wire for phase and neutral & 2.5 sq.mm earth wire.(outdoor type)
Supplying and Providing mains with 3 nos. of 1.5 sq mm Cu. FRLS insulated flexible wire with ISI approval for 650 V/ 1100 V and be drawn in 25 mm diameter rigid PVC conduit of medium gauge having ISI approval with all necessary accessories.
j) 4.00 Sq.mm 3 core round PVC sheathed
Supplying & erecting single phase approved make industrial exhaust fan suitable for medium duty ring mounted low noise operation suitable for medium duty having following dia size and maximum speed in RPM [A] 305 mm dia 900 RPM
Providing & laying approved make Double walled corrugated pipes (DWC) of polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same material at required depth for laying of cable. below ground / road surface for enclosing cable and back filling the same to make ground as per original. (A)50 mm dia
External Lighting Supply & installation of light pole with complete with base plate and as per required fixture mounting with foundation as per requirement complete in all respect as per drawing. Junction box shall be in concealed manner (inside the pole) with 1 no 6A SP mcb. 6 way 16A Connector strip suitable to terminate armoured cables. Adequate size cutout with opeanable hinged door should be provided on pole with necessary gasket to ensure water tight arrangement for pulling cables and installation of mcb, connectors etc, complete in all respect as per requirement and instruction of engineer in charge. Scope also includes necessary foundation, earthing, cable entry pipes, 3 core round flexible wire from junction box to light fixture etc,(B) Approx 4.0 Mtr long, light pole Type - B with basic rate of Rs. 26,000/- for street lighting
Any kind of External light fixture Type - C with Basic rate of Rs 10,000/- (up to Rs. 15,000/-)
Providing and fixing POST TOP LIGHT, Type -1 (L1), Make : REYTEK Model : Asymmetrical, Wattage : 9W LED, Temperature : 3000 K, IP Rating : IP - 65, Fixture Colour : Black
Section feeder Pillar-1 (for Metering)( Outdoor Type) Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning double compartmentalized Double door type section feeder pillar with IP 54 protection & should be powder coated fabricated from 14 Gauge CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Architect/ Consultant. All civil work including RCC platform for section pillar should be in scope of Electrical contractor complete in all respect as per detail drawing and directed by engineer incharge. As per SLD, Separate Compartment for each outgoing feeder for each LT Meter, LT Meter should be install by Supply company. (Scope : LT meter shall be supply by local supply company & only vacant compart shall be provided for each LT meter rest of all items inclusing wiring should be consider in scope)
Section feeder Pillar-2 (for Metering)( Outdoor Type) Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning double compartmentalized Double door type section feeder pillar with IP 54 protection & should be powder coated fabricated from 14 Gauge CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Architect/ Consultant. All civil work including RCC platform for section pillar should be in scope of Electrical contractor complete in all respect as per detail drawing and directed by engineer incharge. As per SLD, Separate Compartment for each outgoing feeder for each LT Meter, LT Meter should be install by Supply company. (Scope : LT meter shall be supply by local supply company & only vacant compart shall be provided for each LT meter rest of all items inclusing wiring should be consider in scope)
Section feeder Pillar (For External lighting) ( Outdoor Type) Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning double compartmentalized Double door type section feeder pillar with IP 54 protection & should be powder coated fabricated from 14 Gauge CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Architect/ Consultant. All civil work including RCC platform for section pillar should be in scope of Electrical contractor complete in all respect as per detail drawing and directed by engineer incharge. As per SLD
Light Fixtures Supplying, erecting, connecting, testing and commissioning of Following type Light Fixture with all necessary Hardware, Internal Wiring with Lamp, Ballast etc. all required accessories Complete in all respect. Cost includes wiring from outlet point to light fixtures and also wiring from first light fixtures to second light fixtures wherever provided on back to back (touching each other) arrangements. Any kind of light fixture Type - A with LED fixture with basic rate of Rs 1500/- ( up to 2250)
Providing and fixing WALL WASHER LIGHT, Type - 7B (L7B), Make : K-LITE Model : Asymmetrical, Wattage : 01W LED, Temperature : 3000 K, IP Rating : IP - 67, Fixture Colour : Powder Coated Graphite Gray
Providing and fixing WALL WASHER LIGHT, Type - 7A (L7A), Make : K-LITE Model : Asymmetrical, Wattage : 05W LED, Temperature : 3000 K, IP Rating : IP - 67, Fixture Colour : Powder Coated Graphite Gray
Providing and fixing CEILING LIGHT, Type - 10 (L10),Make : K-LITE Model :Cylin Mini 3647, Wattage : 12W LED, Temperature : 3000K/4000K, IK Rating : 06-10, Fixture Colour : Black
Providing and fixing TRE UPLIGHT, Type - 6 (L6), Make : K-LITE Model : Asymmetrical, Wattage : 05W LED, Temperature : 3000 K, IP Rating : IP - 67, Fixture Colour : Powder Coated Graphite Gray
Providing and fixing SHRUB UPLIGHT, Type - 5 (L5), Make : K-LITE Model : Asymmetrical, Wattage : 12W LED, Temperature : 3000 K, IP Rating : IP - 67, Fixture Colour : Powder Coated Graphite Gray
Providing and fixing STEP LIGHT, Make : K-LITE Model : klr-2747 Sudo mini asy fram, Wattage : 06W LED, Temperature : 3000 K, IP Rating : IP - 65, with IP-67 Connector, Fixture Colour : Powder Coated Graphite Gray
Providing and fixing BOLLARD LIGHT, Make : K-LITE Model : klr-2747 Sudo mini asy fram, Wattage : 16W LED, Temperature : 3000 K, IP Rating : IP - 65, with IP-67 Connector, Fixture Colour : Powder Coated Graphite Gray
Providing and fixing WALL MOUNT LIGHT, Make : K-LITE Model : klr-2747 Sudo mini asy fram, Wattage : 12W LED, Temperature : 3000 K, IP Rating : IP - 65, with IP-67 Connector, Fixture Colour : Powder Coated Graphite Gray
Supplying and erecting approved make bracket fan of 230 volts , A.C. 50 cyl/s., 400/450 mm sweep complete erected on wall or with lead cores and connections complete. [SOR (Electrical) : 5-4-2/106]
6/16A x 250 Volt switched socket outlet point for outside with 4 sq.mm wire for phase and neutral & 2.5 sq.mm earth wire.(outdoor type)
Exhaust fan outlet point with 6A 5 pin socket controlled by one 5 single way switch located at different location.
Supplying and Providing mains with 4 nos. of 6 sq mm Cu. FRLS insulated flexible wire with ISI approval for 650 V/ 1100 V and 2 nos 2.5 sqmm Cu. FRLS insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 40 mm diameter rigid PVC conduit of medium gauge having ISI approval with all necessary accessories.
Supplying and Providing mains with 3 nos. of 2.5 sq mm Cu. FRLS insulated flexible wire with ISI approval for 650 V/ 1100 V and be drawn in 25 mm diameter rigid PVC conduit of medium gauge having ISI approval with all necessary accessories.
Supplying and erecting Flexible PVC insulated multistrand multicore 1.1 kv grade ISI marked copper wires of following size to be erected as directed. (h) 2.50 Sq.mm 3 core round PVC sheathed
Providing and erecting required size HOT deep Galvanised strip for earthing of H.T. OCB / ACB / Transformer LT panel board, Motors etc. using copper clamp.
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed. 25mm
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) suitable for(iv)12 way
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) suitable for(B) three phase incoming and single phase horizontal type outgoing Per phase isolation type (PPI)(ii)6 way
Point wiring for on board Looped Plug with 6A Modular type switch & 5 pin socket erected on PVC / Metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate modules erected on / in wall / ceiling with following type accessoriesCat. III
providing and erecting Approved make RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for operation on single phase 240 V,50Hz. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. rating erected as directed(ii) 40Amps. DP Cat-III
providing and erecting Approved make RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for operation on single phase 240 V,50Hz. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. rating erected as directed(ii) 40Amps. FP Cat-III
Supplying & erecting earth pit of minimum bore dia.150mm size approved make Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free hot dipped G.I.Pipes having Outer pipe dia of 50mm having 80-200 Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron galvanising, connection terminal dia of 12mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications with chamber and heavy duty cover. (A)(approved make OEM has to submit test certificate including value of earth resistance of installation duly stamped and signed by agency and officer Incharge has to ensure the value of earthing resistane mentioned in test Certificate) & having back filling compound of (B) Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm / meter testing as per IEC 62561-2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar content:- <2%(C) Back fill Compound :- Earthing compound should be capable to retain moisture for long time Necessary test report must be submitted by Agency. (b)For Electrical installation up to 11 KV in normal soil. Length of Pipe : 2.00 mtrs Back filling Compound :1 no. Bag of 25 Kg.
Providing and erecting Pipe type earthing with 40 mm dia 1.00 mtr long 'B' grade G.I. pipe with necessary coupling buch buried in specially prepared earth pit & G.I. earth wire of 8 SWG erected & connected as directed
Existing light pole Reparing & Re- installation, testing with base plate and as per required fixture mounting with foundation as per requirement complete in all respect as per drawing. Junction box shall be in concealed manner (inside the pole) with 1 no 6A SP mcb. 6 way 16A Connector strip suitable to terminate armoured cables. Adequate size cutout with opeanable hinged door should be provided on pole with necessary gasket to ensure water tight arrangement for pulling cables and installation of mcb, connectors etc, complete in all respect as per requirement and instruction of engineer in charge. Scope also includes necessary foundation, earthing, cable entry pipes, 3 core round flexible wire from junction box to light fixture etc,(B) Approx 4.0 Mtr long, light pole
Providing and fixing Existing light pole service window a in all respect as per requirement and instruction of engineer in charge.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .