Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹3.2 L
EMD Value
₹6,360
Closing Date
16 Oct 2026, 5:00 pm4d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
EE PWD Elec Dn Ajmer
EE PWD Elec Dn Ajmer
Electrical R and M Work in Various Blocks at Govt. JLN Hospital Ajmer
2026_CEPWD_603717_35
NIT22 2026-27 EE PWD Elec Dn Ajmer
Open Tender
Electrical Works
Percentage
365 days
Ajmer
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
Egras Challan EE PWD Elec Dn Ajmer 7820
₹6,360
Yes
11 Oct 2026
11 Oct 2026
16 Oct 2026
11 Oct 2026
16 Oct 2026
11 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1E01 Electrical Wiring in PVC Conduit | |||||
| 2Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal/Surface mounted UPVC molded modular box, 6 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. | |||||
| 2.1 | On board | 15 | P. point | 310 | ₹4,650 |
| 3Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanism , energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. | |||||
| 3.1 | Single pole MCB (With B / C curve tripping characteristics) | - | - | - | - |
| 3.2 | 6 A to 32 A rating | 18 | Each | 169 | ₹3,042 |
| 4Double pole MCB (With B / C curve tripping characteristics) | |||||
| 4.1 | 40 A rating | 7 | Each | 899 | ₹6,293 |
| 5Four pole MCB (With B / C curve tripping characteristics) | |||||
| 5.1 | 50/63 A rating | 1 | Each | 1,737 | ₹1,737 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.92 MB
Tendernotice_2.pdf
PDF • 23.83 MB
Tendernotice_3.pdf
PDF • 4.91 MB
Tendernotice_4.pdf
PDF • 1.76 MB
BOQ_1070760.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .