Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹26.5 L+₹35,416.40 (1.36%)Rejected-Finance | L2 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 3 | L3₹26.8 L+₹65,295.20 (2.50%)Rejected-Finance | L3 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 4 | L4₹27.0 L+₹84,799.70 (3.25%)Rejected-Finance DARJEELING DHOTREY FOREST BANSBOTAY DARJEELING P S DARJEELING DHOTREY FOREST BANSBOTAY DARJEELING P S DARJEELING DARJEELING WEST BENGAL 734201 | DARJEELING | WEST BENGAL | 734201 | L4 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 5 | L5₹27.1 L+₹98,135.80 (3.76%)Rejected-Finance | L5 | Rejected-Finance HIGHER THEN L1 BIDDER |
Tender Value
₹23.6 L
EMD Value
₹48,000
Closing Date
11 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE
HQ 136 WORKS ENGINEERS PIN - 914136 C/O 99 APO
ADDN / ALTN AND UPGRADATION OF BLDG NO T-31 AT JALAPAHAR UNDER AGE(I) DARJEELING
2023_MES_614396_1
CWE/136-WE/11 OF 2023-24
Open Tender
Civil Works
Item Rate
240 days
Darjeeling
Class E, Category a(I)
8 documents required · 8 mandatory
₹500
AGE (I) Darjeeling
₹48,000
Yes
8 Jan 2024
18 Aug 2023
12 Sept 2023
18 Aug 2023
11 Sept 2023
2 Sept 2023
18 Aug 2023 - 25 Aug 2023
Amount
Taking down cement or cement lime plaster, any description on brick or stone masonry surfaces of walls etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed.
M&L for rendering 20mm thick (two layer, 10mm and 10mm thick) in cement mortar (1:4) with water proofing compound @ 3% by weight of cement in second layer or in the manner specified by the manufacturer and in the proportions indicated on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra lime or cement), complete all as specified and directed. Note: Water proofing compound will be measured and paid separately
M&L for 15 mm thick rendering in cement mortar (1:6) on stone masonry surfaces or surfaces other than fair faces of brick work, rendering finished even and smooth (without using extra cement), complete all as specified and directed.
Supply only integral water proofing compond, all as specified and as directed.
M&L for preparation of new plastered or unplastered surface of wall and applying two coats of distemper oil emulsion (OBD), over a coat of priming coat (Chalk whiting, on plastered surfaces, prepara-tory to distempering) including 3mm thick wall care putty on wall, complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying two coats of exterior weather coat paint over a coat of alkali resistant primer, complete all as specified and directed.
M&L for hardcore using broken stone or boulders of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation, complete all as specified and directed.
M&L for 100 mm thick plain cement concrete(1:3:6), type C2 (using 40 mm graded stone aggregate) as in flooring, plinth protection, hard standing, path etc including finish the surface rough to receive screed bed, complete all as specified and directed.
M&L for coloured non-skid ceramic tiles 7 to 8 mm thick, area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles including screed bed or bedding layer of mortar 20 mm thick for laying floor finishes in cement mortar (1:6), complete all as specified and directed.
M&L for coloured non-skid ceramic tiles 7 to 8 mm thick, area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles on vertical surfaces such as skirtings, dados and risers to steps etc. including 10 mm thick rendering in cement mortar (1:4), complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets, complete all as specified and directed.
S&F of anodised aluminium snap grid frame work of size of grid 605 x 605mm, with aluminium tee section of size 23.5mm x 26.4mm x 1.4mm thick and aluminium angle section of size 36.5mm x 25mm x 1.4mm thick for false ceiling including hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long including 4mm thick non asbestos fibre cement building boards as per IS-14862, fixed or laid/ inserted to timber / GI / aluminium framework with screws, complete all as specified and directed.
M&L for brickwork with fly ash bricks(old size bricks), straight or curved on plan exc 6m mean radius, built in cement mortar(1:6), complete all as specified and directed.
M&L for brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar(1:4), complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed.
S&F of pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
S&F of pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
S&F of framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel'), complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floor and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for 75 mm thick plain cement concrete(1:3:6), type C2 (using 40 mm graded stone aggregate) as in plinth protection, hard standing, path / paving etc. including finish the surface even and smooth without using extra cement, complete all as specified and directed.
Taking down chowkhats or frames not exc. 1.5 sq. m each with shutters (without taking off shutters from the frame), complete all as specified and directed.
Taking down chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each with shutters (without taking off shutters from the frame), complete all as specified and directed.
S&F pressed steel frame of size 105 x 60mm for door with one or more rebates including necessary fixing, lugs, hinges, lock, strike plate, etc complete all as specified.
M&L for plain cement concrete (1:3:6), type C1 (using 20 mm graded crushed stone aggregate) as in bed blocks for grouting hold fasts, coping, filling in pressed steel chowkat or similar work including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
S&F of 35 mm thick (batten thickness) second class hard wood, plain, framed panelled shutters (any number of panels), with panels of 12 mm thick timber flat on both sides (feather edged), or of 12mm thick veneered particle board medium density wood particle board with commercial face veneers complete all as specified and directed. (Note :- The dimension of the various components or parts of shutters shall be as specified in clause 8.24 (a) of MES SSR 2009 Part I) and directed.
M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
S&F of 100mm size butt hinges, medium weight, cold rolled mild steel, and fixed, all as specified and directed.
S&F of 125 mm size aluminium handles, cast type, anodised, all as specified and directed.
S&F of 200mm long aluminium anodised, barrel tower bolts of extruded section and fixed, all as specified and directed.
S&F of 4.8mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane, complete all as specified and directed.
M&L for preparation of new wooden or wood based surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails, complete all as specified and directed.
S&F of anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc., complete all as specified and directed.
S&F of anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc., complete all as specified and directed.
S&F of anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/stainless steel screws @200mm center to center, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.
Excavation in post holes (or similar holes) in hard rock, each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface, complete all as specified and directed.
M&L for plain cement concrete (1:3:6), type C2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and as directed.
S&F of rolled mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified and directed.
M&L for providing precast cement concrete (1:2:4), type B1 (using 20mm graded crushed stone aggregate) in window or door cills,lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings, kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin), corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in cement mortar (1:6) complete with joints to match, all as specified and directed.
Dismantling timber scantlings 40 Sqcm and over in section, in any position (unframed work), all as specified and directed.
M&L for well seasoned second class hard wood timber scantling (clean sawn) in timber fixed work, complete all as specified and directed.
M&L for preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with two coats of creosote oil, complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and directed.
S&F of 180mm bore PVC (SWR) half round gutter drain pipe, complete all as specified and directed.
S&F of 180mm bore PVC (SWR) joint socket, complete all as specified and directed.
S&F of 180mm bore PVC (SWR) joint tee with end cap, complete all as specified and directed.
S&F of 180mm bore PVC (SWR) pipe clamp, complete all as specified and directed.
S&F of 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, complete all as specified and directed.
S&F of 110mm bore PVC (SWR) bends any radius, complete all as specified and directed.
S&F of curtain rails / harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc., complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and directed.
Taking down DB's including fixture and fittings such as MCBs any type / size, complete all as specified and directed.
Taking down carefully sub main wiring of any size/core/type including conduit/ cashing/ batten of any type and making good disturbed surfaces to match with the existing surface roof/ wall/ floor, complete all as specified and directed.
M&L for point wiring with 1.5 Sq.mm (nominal area) PVC insulated sheathed single core multi stranded copper conductor FRLSH cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC conduit not less than 20mm dia (concealed), medium grade with all necessary fittings, concealed wiring, for light / fan / bell on independent board, point controlled by one switch including 1.5 Sq mm PVC FRLSH insulated copper stranded conductor for earth continuity conductor and connected to earth dolly and to be terminated in 1.60 mm thick pressed steel terminal boxes including flush metal box 2/4/6/8/12 module with module inner and outer plates for mounting moduler switches, socket outlet, regulator etc. with 3 mm thick laminated bakelite sheet cover for housing switches, socket outlet, regulator etc., complete all as specified and directed including testing on completion. Notes:- (i) Proper colour coding of PVC insulated copper wire should be maintained as red/yellow/blue wires for phases, black wire for neutral and green wire for earth. (b) Two run of 1.5 Sq.mm for phase and neutral and one run of 1.5 Sq.mm for earth wire. (c) Concealed type in permanent bldg and surface type in temporary bldg or as directed)
M&L for point wiring with 1.5 Sq.mm (nominal area) PVC insulated sheathed single core multi stranded copper conductor FRLSH cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC conduit not less than 20mm dia (concealed), medium grade with all necessary fittings, concealed wiring, for one 3 / 5 -pin socket outlet, 5 amps on independent board from DB, point controlled by one switch including 1.5 Sq mm PVC FRLSH insulated copper stranded conductor for earth continuity conductor and connected to earth dolly and to be terminated in 1.60 mm thick pressed steel terminal boxes including flush metal box 2/4/6/8/12 module with module inner and outer plates for mounting moduler switches, socket outlet, regulator etc. with 3 mm thick laminated bakelite sheet cover for housing switches, socket outlet, regulator etc., complete all as specified and directed including testing on completion. Notes:- (i) Proper colour coding of PVC insulated copper wire should be maintained as red/yellow/blue wires for phases, black wire for neutral and green wire for earth. (b) Two run of 1.5 Sq.mm for phase and neutral and one run of 1.5 Sq.mm for earth wire. (c) Concealed type in permanent bldg and surface type in temporary bldg or as directed)
M&L for point wiring with 2.5 Sq.mm (nominal area) PVC insulated sheathed single core multi stranded copper conductor FRLSH cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC conduit not less than 20mm dia (concealed), medium grade with all necessary fittings, concealed wiring, for one 6 -pin socket outlet, 15 amps on independent board from DB, point controlled by one switch including 2.5 Sq mm PVC FRLSH insulated copper stranded conductor for earth continuity conductor and connected to earth dolly and to be terminated in 1.60 mm thick pressed steel terminal boxes including flush metal box 2/4/6/8/12 module with module inner and outer plates for mounting moduler switches, socket outlet, regulator etc. with 3 mm thick laminated bakelite sheet cover for housing switches, socket outlet, regulator etc., complete all as specified and directed including testing on completion. Notes:- (i) Proper colour coding of PVC insulated copper wire should be maintained as red/yellow/blue wires for phases, black wire for neutral and green wire for earth. (b) Two run of 2.5 Sq.mm for phase and neutral and one run of 2.5 Sq.mm for earth wire. (c) Concealed type in permanent bldg and surface type in temporary bldg or as directed)
S&F of switch piano, flush type single pole, one way, 5 Amps / 6 Amp, complete all as specified and directed.
S&F of ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body, complete all as specified and directed.
S&F of switch socket combination 2 in 1, 3 Pin / 5 Pin, 5 Amps / 6 Amps flush type, complete all as specified and directed.
S&F of switch socket combination 5 in 1, 6 Pin, 6Amps / 16Amps, flush type universal, complete all as specified and directed.
Supply and fixing of wall mounted energy efficient LED tube light fittings, 1x20 watts, with bipin holders, connector block, CCT - 6500K, system output lumen not less than 2000lm, extruded aluminium housing with high quality Polycabonate diffuser, wide voltage protection range 140V-270V including connecting up with PVC insulated 2 core sheathed 0.5 sqmm copper conductor two numbers PVC mounting blocks for fixing of fitting, complete all as specified and directed.
Supply and fixing of sleek LED bulk head fittings 10 watts, complete all as specified and directed. Make: Crompton Greaves (Cat No.- LBHP-10-CDL), Philips (Cat No.- WT202W LED6S NW PSU S2 PC), Havells (Cat No.- HEXAFT10WLED857SSYMBOPC) or equivalent model of approved make as per tender documents.
S&F of building security light fittings new generation energy saving and enviornmental friendly long life versatile pressure die-cast aluminium IP66 protection with acrylic cover of LED 30 watts luminaire including GI bracket of suitable size with clamp, complete all as specified and directed.
S&F of sub main wiring with two single core 6.0 Sqmm PVC (FRLSH) copper conductor, insulated multistranded unsheathed cable medium grade including PVC conduit concealed of required size (not less than 32mm) conforming to IS 2079-1973 with accessories for sub main connection including 6.0 Sqmm PVC (FRLSH) insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified and directed. (Note:- Three runs of 6.0 sqmm PVC FRLSH copper conductor shall be measured as one unit length).
S&F of sub main wiring with two single core 2.5 Sqmm PVC (FRLSH) copper conductor, insulated multistranded unsheathed cable medium grade including PVC conduit concealed of required size (not less than 32mm) conforming to IS 2079-1973 with accessories for sub main connection including 2.5 Sqmm PVC (FRLSH) insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified and directed. (Note:- Three runs of 2.5 sqmm PVC FRLSH copper conductor shall be measured as one unit length).
Supply and fixing of triple pole and neutral(TPN) DB with sheet metal enclosure, 4 way, double door 200 Amps, 415 volt with rated bus bar including fixing on suitable rectangular block, complete all as specified and directed.
Supply and fixing of sheet metal enclosure, double door for MCB DB's, 8 way single pole & neutral (SPN) and current carrying capacity of 200 amps rated bus bar suitable for 240 Volt, AC, 50Hz, complete all all as specified and directed.
Supply and fixing of sheet metal enclosure, double door for MCB DB's, 4 way single pole & neutral (SPN) and current carrying capacity of 200 amps rated bus bar suitable for 240 Volt, AC, 50Hz, complete all all as specified and directed.
Supply and fixing of 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole (SP) and current carrying capacity of 5 To 32 AMP in the MCB DB complete with connection testing and commissioning, complete all all as specified and directed.
Supply and fixing of 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole & neutral (SPN) and current carrying capacity of 40 to 63 AMP in the MCB DB complete with connection testing and commissioning, complete all all as specified and directed.
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) of triple pole and neutral (TPN) and current carrying capacity 40 to 100 Amps in the DB, complete with connection testing and commissioning, complete all as specified and directed.
Material and labour for earthing complete with galvanised steel earth plate electrode 60cm × 60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron or steel earth lead wire 4.0mm dia size by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES SSR Part-I, connected to earthing test point all as specified or indicated including testing on completion, including necessary excavation and earth work in any type of soil, GI pipe 20mm dia light grade for watering and GI 15mm dia light grade pipe for protection of earth wire upto DB / test point from earth plate etc., PCC chamber with PCC cover in cement concrete (1:2:4), type B1 (using 20mm graded stone aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to DB as indicated, complete all as specified and as directed. Notes: Contractor should conduct necessary test such as earth continuity, earth resistance test in presence of Engineer-in-Charge.
Taking down carefully old unserviceable rusted aluminium / GI strip, air termination rod and terminal boxes from the slant roof / wall of the building including complete fittings such as insulators, saddles etc., removing materials from site and making good distrubed surface of walls and roof of the building etc., complete all as specified and directed.
M&L for air termination, single pointed aluminium rod 12mm dia and 300mm long, complete all as specified and directed.
M&L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw, complete all as specified and directed.
M&L for aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground, complete all as specified and directed.
M&L for galvanised iron (GI) strip 32 x 6mm buried in ground, complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cm × 60cm × 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to using galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-l connected to earthing test point all as specified or indicated including funnel with GI medium grade watering pipe 20 mm bore with wire mesh, 40 mm bore GI light grade pipe for protection of earth lead conductor from earth plate to terminal block box, providing charcoal and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with concrete pit in PCC 1:3:6, type C1, 50 mm thick pre cast RCC 1:2:4 type B1 cover slab reinforced with 8 mm dia reinforced bar 15 cm C/C and earth lead handle protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50m including testing on completion, complete all as specified and directed.
Note 1:- (Applicable for all parts/items) : The bidders/contractors are advised to read tender document, all drawings & all corrigendum / amendments and general condition of contracts before entry / quoting the rates. Note 2:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount.
Darjeeling Enterprises
M/S TSHERING BHUTIA
REEMA TAMANG AND SONS
SANJAY KAUSHIK
RAI CONSTRUCTION
KWOK YING CHIU
JALAPAHAR HARDWARE
HIRA SINGH
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .